USER MANUAL

MODEL NUMBER: F1.5L, F1.5LBK and related units

1.5 Liter Pump-Up Foam Unit

English (Original Instructions)

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

⚠️ WARNING

Read this manual completely and understand the machine before operating or servicing it.

  • [Read Instructions] Read all instructions before installing or operating unit.
  • [Wear PPE] Always wear appropriate personal protective equipment (PPE) when operating or servicing unit.
  • [Chemical Safety] Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Safety Data Sheet (SDS).
  • [No Modification] If this unit is modified or serviced with parts not listed in this manual, the unit may not operate correctly.
  • [No Pointing] Never point the discharge wand at yourself, another person, or any object you do not want covered in chemical.
  • [No Unattended] Never leave unit unattended while pressurized.
  • [Depressurize Before Service] Always depressurize unit before attempting to remove the pump assembly.
  • [Store Depressurized] Always depressurize unit after use (as described in the After Use Instructions). Always store unit depressurized.
  • [Use Built-in Pump Only] Do not pressurize unit by any means other than the built-in pump assembly.
  • [Pressure Relief Valve Integrity] Do not modify or remove pressure relief valve. Do not use unit if pressure relief valve is not operational.
  • [Flush Between Chemicals] Always flush the unit with fresh water when switching from an alkaline to an acid or an acid to an alkaline.
  • [Carry by Handle] Always carry unit by the carrying handle. Never lift or carry the unit by the pump handle or the wand.
  • [No Hydrocarbons] Never use unit with hydrocarbons or flammable products.
  • [Temperature Limit] Do not exceed a fluid temperature of 100°F (37°C).

REQUIREMENTS

Requirement Details
Liquid temperature range 40-100°F (4.4-37°C)
Chemical compatibility Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or SDS for your product or contact customer service.

SPECIFICATIONS

Specification Detail
Power type Manual
Chemical pickup type Draws from pre-mixed solution
Number of products unit can draw from One product
Operating Capacity 0.3 gallon (1.1 liter)
Discharge wand/tip type Polypropylene trigger handle with 110 degree fan tip
Output distance 1-2 ft (0.3-0.6 m)
Pump seals Viton

PROTECT THE ENVIRONMENT

Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations. Always remember to recycle.

*Specifications and parts are subject to change without notice.

Operation Instructions

  1. Ensure all air pressure is released from unit by activating the pressure release valve (located on the side of the pump assembly (PA-F1.5L)).
  2. Securely hold the unit and unscrew the pump assembly (PA-F1.5L) from the tank in a counter-clockwise motion.
  3. Follow all instructions from chemical manufacturer. Fill tank 3/4 of the way with pre-mixed solution. (Note: Do not overfill tank with solution.)
  4. Securely hold the tank and screw the pump assembly (PA-F1.5L) back on in a clockwise motion.
  5. Pressurize the tank by pumping approximately 20 to 25 times, or until it becomes difficult to pump. (Note: The pressure relief valve will leak if the air pressure is too high. Do not overfill tank with air.)
  6. To start foaming, point the wand assembly at the area you wish to foam and press down on the On/Off control to discharge foam. Release On/Off control to stop foaming.
  7. For drain applications, position drain attachment over the drain or insert plug into drain. To start foaming, point the wand assembly at the area you wish to foam and press down on the On/Off control to discharge foam. Release On/Off control to stop foaming.

After Use Instructions

  1. Release air pressure from unit after each use by activating the pressure release valve (located on the side of the pump assembly (PA-F1.5L)).
  2. It is recommended to always empty out remaining solution and run fresh water through the unit to rinse all parts thoroughly after each use and before storage.

Maintenance Instructions

Warning: Always depressurize unit before performing maintenance.

To keep your unit operating properly, periodically perform the following maintenance procedures:

Component Diagrams

Pump Assembly

Diagram shows the pump assembly (Item Number: PA-F1.5L) with controls labeled 'On/off' and 'Pressure relief valve'.

Wand Assembly

Diagram shows the wand assembly (Item Number: WA-F1.5L) with components labeled: PW-1.5L (Poly Wand), WD-F1.5L (Wadding Disk), STB-F1.5L (Spray Tip), WA-1.5L-OR (O-Ring), WA-1.5L-RN (Retaining Nut). An exploded view shows these parts disassembled, including PST-F1.5L (Suction Tube).

Tanks

Diagram shows two cylindrical tanks: TANK1.5L (white tank) and TANK1.5LBK (black tank). Both feature a 'Liquid level viewing stripe' with volume markings.

Units with Drain Attachments

Diagram for unit with drain attachment (Item Number: WA-F1.5L-DP.75): Shows a wand assembly connected to a hose barb (DHB3814), tubing (H14C), and a drain cup (RDC12). Components include WA-1.5L-RN, WA-1.5L-OR, WD-F1.5L, PW-1.5L.

Diagram for unit with drain attachment (Item Number: WA-F1.5L-DP3.75): Shows a wand assembly connected to a hose barb (DHB3814), tubing (H14C), hose barb (HB1414), hose mender (HM1414), and a drain cup (RDC12). Components include WA-1.5L-RN, WA-1.5L-OR, WD-F1.5L, PW-1.5L.

Parts List

Item Number Description
DHB3814 3/8 FLAT SEAT 1/4 HOSE BARB
H14C 1/4in ID CLEAR POLYVINYL TUBING - Available per ft. (3/8 in OD)
HB1414 1/4in MPT X 1/4in HOSE BARB
HM1414 HOSE MENDER - 1/4 inch BARB X 1/4 inch BARB
PA-F1.5L PUMP ASSEMBLY FOR 1.5L FOAM UNIT
PW-1.5L POLY WAND FOR 1.5L PUMP UP
RDC12 RUBBER DRAIN CUP FOR 1/2 INCH BARB
RMS2 RUBBER MOLDED STOPPER-SIZE #2-EPDM
STB-F1.5L BUTTON SPRAY TIP FOR 1.5L PUMP UP
TANK1.5L 1.5L TANK-WHITE
TANK1.5LBK 1.5L TANK-BLACK
WA-1.5L-OR O-RING FOR 1.5L WAND ASSEMBLY
WA-1.5L-RN RETAINING NUT FOR 1.5L WAND ASSEMBLY
WD-F1.5L WADDING DISK FOR 1.5L PUMP UP (1 PIECE)
PST-F1.5L SUCTION TUBE
Models: F1.5L Gallon Foam Unit, F1.5L, Gallon Foam Unit, Foam Unit

PDF preview unavailable. Download the PDF instead.

F1.5l usermanual GPL Ghostscript 9.55.0 Adobe InDesign CS6 (Windows)

Related Documents

Preview 1.3 Gallon Pump-Up Foam Unit User Manual
Comprehensive user manual for the 1.3 Gallon Pump-Up Foam Unit, covering models F5.0L and F5.0L-PSG. Includes detailed safety warnings, product specifications, operating instructions, maintenance procedures, servicing information, and available attachments for optimal use and care.