User Guide for Additel models including: 762, 762 Automated Hydraulic Pressure Calibrator, Automated Hydraulic Pressure Calibrator, Hydraulic Pressure Calibrator, Pressure Calibrator
Additel 762 Automated Hydraulic Pressure Calibrator - https://mme-ae.com
Pressure Calibration Equipment Additel 762 Automated Hydraulic Pressure Calibrator Automated pressure generation and control to 10,000 psi (700 Bar) Accuracy to 0.01%FS Dual-range manual or auto select Control stability 0.005%FS Portable - designed for use in the field and in the lab Control by optional external pressure modules Supports two external pressure modules Wi-Fi, LAN, Bluetooth, USB and Ethernet communication Full HART field communicator HART and PROFIBUS communication Data logging and task management Patented electric pump technology OVERVIEW The Additel 762 Automated Pressure Calibrator is unlike any other pressure calibrator on the market. This revolutionary product is a complete turnkey solution for automation of pressure calibration work up to 10,000 PSI. Designed for use in both the field and the laboratory, the portability and accuracy of this state-of-the-art product will quickly become the favorite go-to calibrator for lab personnel and field technicians alike. With fully automated support for calibration of pressure transmitters, switches, dial and digital gauges and sensors, including HART/PROFIBUS devices in conjunction with a fully integrated task feature, data collection and Wi-Fi connectivity, we had our customer's needs in mind when designing our most capable pressure calibrator to date. 01 Phone: 714-998-6899 Email: sales@additel.com Rev # 20230130 Corporate Headquarters 2900 Saturn St #B Brea, CA 92821, USA Salt Lake City Office 1364 West State Rd. Suite 101 Pleasant Grove, UT 84062, USA Pressure Calibration Equipment Dual-Range Accuracy to 0.01% FS The ADT762 includes the unique ability to automatically switch between different internal calibrations depending on the current control pressure of the ADT762. Additel provides calibrations unique to each ADT762 for ranges of 0-3,000 PSI (200 Bar) and 0-10,000 PSI (700 Bar). As the calibrator is pressurized, it will automatically select the control and measurement specification based on the specific pressure range. Pressure calibration range selection can be set to "auto" mode so the calibration range is automatically selected by the ADT762 based on the set point pressure, or the calibration range can be manually selected. Built-in Auto-Purge Application Purging hydraulic calibration systems can be challenging and time consuming. The ADT762 has been designed with an integrated auto-purge system that saves time, money and frustration by completely automating the removal of air from the system. With the push of a button, the ADT762 quickly manages the system purging. This helps to free up time for technicians to attend to other needs. Documented Task Feature The powerful documented calibration task application allows users to quickly create and execute tasks without the need for a PC or tablet. The ADT762 automatically analyzes errors, generates test reports, while storing results locally. The Additel 762 can support up to 1000 documented tasks which can be stored and recalled at any time to help save time and money. Dual-Mode HART Communication HART pressure transmitters can be directly maintained and calibrated without any other equipment or tools. The ADT762 provides an automatic HART calibration mode as well as a manual mode. This dual-mode HART communication function not only provides an efficient and convenient interoperability mode for DUT, but also supports access to a fully HART capable calibrator. 02 Phone: 714-998-6899 Email: sales@additel.com Rev # 20230130 Corporate Headquarters 2900 Saturn St #B Brea, CA 92821, USA Salt Lake City Office 1364 West State Rd. Suite 101 Pleasant Grove, UT 84062, USA Pressure Calibration Equipment Pressure Specifications Specification Pressure Range Range Selection Model ADT762 Automated Hydraulic Pressure Calibrator 15~10,000 psi (1-700 Bar) Manual 3K psi, Manual 10K psi or Auto-range Accuracy 0~10,000 psi, 0.01%FS 0~3,000 psi, 0.01%FS 0~10,000 psi, 0.02%FS 0~3,000 psi, 0.02%FS Resolution 7 digits 6 digits Maximum External Load Capacity Reservoir Control Stability [1] Stability Duration Max: 80 ml@700 Bar, 50 ml recommend Max: 350 ml, built-in filter 0.005%FS from 100 to 10,000 psi 5 min Pressure Module Built-in one module with dual range External Control Pressure Module See the following "External Control Pressure Module Specification and Compatibility" table External Measurement Pressure Module [1] Control Stability is based on the range selection or external module All ADT161 pressure modules Electrical Specifications Model Specification mA Measure V Measure V Measure (Auto-ranging) Loop Power Source mA Source Range -25 to 25 mA -50 to 50 mA -300 to 300 mV -5 to 5 V -12 to 12 V -30 to 30 V 24 V 0 to 2.5 mA or 2.5 to 25 mA Resolution 0.1 A 0.1 A 1 V 20 V 100 V 100 V N/A 0-2.5 mA: 0.05A 0-25 mA:0.5A Accuracy ± (0.008%RD + 1.0 A) ± (0.008%RD + 2.0 A) ± (0.008%RD + 6 V) ± (0.008%RD + 100 V) ± (0.008%RD + 320 V) ± (0.008%RD + 600 V) ±1 V 0-2.5 mA: 0.008%RD + 0.2 A 0-25 mA: 0.008%RD + 1.0 A Note Impedance <10 Impedance <1 G Impedance >1 M 50 mA (Max Loading) 20 mA @ 1 K Power Source 16 to 30 V 1 V ±1 V 70 mA (Max Loading) V Source 0 to 16 V Pressure Switch Mechanical Switch, Live Mechanical Switch, NPN Switch, PNP Switch Temperature Compensation 0.25 mV 0.008%RD + 500 V N/A N/A 18 °C to 28°C Response time<10 ms. If the switch is live, voltage range will be (3-30) V Temperature Coefficient Outside of 18 °C to 28 °C: <± 0.0005%RD + 0.00005%FS/°C Misuse Protection Pressure Switch Test HART / PROFIBUS PA Up to 30 V on any two sockets Supported 03 Phone: 714-998-6899 Email: sales@additel.com Rev # 20230130 Corporate Headquarters 2900 Saturn St #B Brea, CA 92821, USA Salt Lake City Office 1364 West State Rd. Suite 101 Pleasant Grove, UT 84062, USA Pressure Calibration Equipment External Control Pressure Module Specification and Compatibility Specification Model Pressure Range (psi) (bar) 1,000 70 1,500 100 2,000 140 ADT161-01-GPXX for 0.01%FS 3,000 200 5,000 350 10,000 700 1,000 70 1,500 100 2,000 140 ADT161-02-GPXX for 0.02%FS 3,000 200 5,000 350 10,000 700 Accuracy 0.01% FS 0.01% FS 0.01% FS 0.01% FS 0.01% FS 0.01% FS 0.02% FS 0.02% FS 0.02% FS 0.02% FS 0.02% FS 0.02% FS Pressure Type Media Gauge G,L Gauge G,L Gauge G,L Gauge G,L Gauge G,L Gauge G,L Gauge G,L Gauge G,L Gauge G,L Gauge G,L Gauge G,L Gauge G,L General Specifications Specification User Interface Display Enclosure IP Rating Power Battery Weight Media Size Communications HART Communication Data Storage Data Logging Task Documentation Automation Functions User Interface Localization Pump Life Environmental Specifications Certification Compliance Software Compatibility Warranty Description Color touch screen and keypad operation 7" TFT touch screen 800 x 480 color IP31 Dedicated lithium battery or power adapter Rechargeable Li-Ion battery, typically 12 hours of operation, less than 5 hours recharge. 28 lbs (12.8 kg) without media Sebacate oil 11.81 x 8.66 x 7.56 in (300 x 220 x 192 mm) USB, LAN, Bluetooth, Wi-Fi and Ethernet Read, configure and calibrate HART devices - DD files updated periodically 8 GB Up to 1,000,000 readings (data and time stamped) Up to 1,000 tasks can be stored with data Switch test, auto step, leak test English, German, French, Italian, Spanish, Portuguese, Chinese, Japanese, and Russian > 1,000,000 cycles Operating temperature: 32 °F to 122 °F( 0 °C to 50 °C) Storage temperature: -20 °C to 60 °C ( -4 °F to 120 °F) Humidity: <90%, non-condensing ISO 17025 accredited certificate of calibration with NIST-traceable data CE ACal, Additel Land and Additel Link for access via mobile application 1 year 04 Phone: 714-998-6899 Email: sales@additel.com Rev # 20230130 Corporate Headquarters 2900 Saturn St #B Brea, CA 92821, USA Salt Lake City Office 1364 West State Rd. Suite 101 Pleasant Grove, UT 84062, USA Pressure Calibration Equipment ORDERING INFORMATION Model Number ADT762 01 GP10K N Accuracy: 01 = 0.01% of full span 02 = 0.02% of full span Pressure port type: N - 1/4 NPT female N2 - 1/2 NPT female B - 1/4 BSP female B2 - 1/2 BSP female M - M20X1.5 female Accessories (included) Model number 9022 Test Leads USB Cable 9725 Rechargeable Li-ion battery 9818 110V/220V external Power adapter Funnel ADT100-762Hose High pressure hose Small accessory case (For cables and adaptors) Transportation cap 9907-762 Carrying case Sebacate oil (500ml) O rings for liquid storage tank 3.5*1.2-NBR70 O rings for right angle connector 5*1.5-NBR70 9060 Pressure module connection cable ADT100-762-X ISO17025 accredited calibration certificate Quantity 2 sets (4 pcs) 1 pc 1 pc 1 pc 1 pc 1 pc 1 pc 1 pc 1 pc 1 bottle 5 pcs 5 pcs 1 pc 1 pc 1 pc Picture Optional Accessories Model number Description ADT107-X-KIT Includes dual ports manifold, and zero return communication cable ADT161 Pressure modules see pg. 4 ADT100-762-X ADT762 right angle connector 9201 Sebacate oil (1-Liter) Picture 05 Phone: 714-998-6899 Email: sales@additel.com Rev # 20230130 Corporate Headquarters 2900 Saturn St #B Brea, CA 92821, USA Salt Lake City Office 1364 West State Rd. Suite 101 Pleasant Grove, UT 84062, USAAdobe PDF Library 16.0.7 Adobe InDesign 17.4 (Windows)