SGP40 ­ Quick Testing Guide

Version 1.2 Stäfa, July 2023

© Copyright Sensirion AG, Switzerland

Confidential

1

Setup

The goal of this quick testing guide is to enable any customer to verify that their Sensirion SGP40 sensors are performing according to specifications. Using only common household items we can create an accurate dilution series of a volatile organic compound (VOC) that will be sufficient to reach this goal.

Required items  2 large bottles (1 l or more)  2 bowls  4 small containers (50­200 ml)  Tap water  Approximately 200 g of table salt (for keeping the relative humidity constant)  1 teaspoon of ethanol(1) (ca. 40% vol. or more)  Either Sensirion SGP40 sensors or SEK-SVM40 EvalKit and Control Center Software (running on any
conventional computer), also see sensirion.com/my-sgp-ek

required time: 2 hours
(1) Any hard liquor or rubbing alcohol will do; you can also try some other concentrated VOC source such as nail polish remover, paint thinner or the like

© Copyright Sensirion AG, Switzerland

Confidential

2

Step one: salt solution
We first want to prepare a reference solutions for diluting: a saturated salt solution.
 Mix 200 g of table salt with 1 l of tap water (room temperature) in one of the bottles  Shake bottle well and let it settle. A lot of the salt won't be dissolved and deposit at the bottom. This is your
salt solution(2) stock.

(2) We use a saturated salt solution because its headspace is non-condensing (ca. 70% relative humidity) and thus more realistic for mimicking indoor climate

© Copyright Sensirion AG, Switzerland

Confidential

3

Step two: high VOC concentration solution
Next, we prepare a high concentration VOC solution as the starting point of the dilution series.
1. In a bowl, mix 250 ml (1 cup) of the salt solution with 1 teaspoon of ethanol 2. Dilute it 10:1 in the second bowl: mix two tablespoons of the solution from step 1 with 250 ml of the salt
solution 3. Dilute it 10:1 once more: in the second bottle, mix two tablespoons of the solution from step 2. with 250 ml
of the salt solution (now we have diluted it roughly 100:1) This is your high concentration solution stock.
You should close the lid of the high concentration solution so that the ethanol does not evaporate and the concentration remains constant.

© Copyright Sensirion AG, Switzerland

Confidential

4

Step three: concentration series
In a next step, we prepare 4 different concentration solutions by diluting our high concentration solution several times. Arrange the 4 small empty containers in front of you.

© Copyright Sensirion AG, Switzerland

Confidential

5

Step three: concentration series
Fill the first container exactly halfway(3) with high concentration solution, the rest halfway with salt solution. Note: Always cover containers when your are not exposing them to sensors so that the VOCs do not evaporate.

1

0

0

0

(3) The absolute amounts are not critical and depend on the size of your containers; just make sure «halfway» is every time precisely the same, and «full» is twice «halfway»

© Copyright Sensirion AG, Switzerland

Confidential

6

Step three: concentration series
Fill the second container with high concentration solution from the stock bottle. Container 2 is now full with half concentration solution.

1

1/2

0

0

© Copyright Sensirion AG, Switzerland

Confidential

7

Step three: concentration series
Fill the third container with half concentration solution from container 2. Then close container 2. Container 3 is now full with quarter concentration.

1

1/2

1/4

0

© Copyright Sensirion AG, Switzerland

Confidential

8

Step three: concentration series
Fill the fourth container with quarter concentration solution from container 3. Then close container 3. Container 4 is now full with 1/8 of the high concentration. We call it the "baseline concentration".

1

1/2

1/4

1/8

© Copyright Sensirion AG, Switzerland

Confidential

9

Step three: concentration series
Discard half of the baseline concentration. We now have four different VOC concentration solutions.

1

1/2

1/4

1/8

© Copyright Sensirion AG, Switzerland

Confidential

10

Step four: training and verification
First we want to train the sensors for the VOC concentration range used in our experiment. Start the measurement using Sensirion Control Center.  expose(4) the sensors to the baseline concentration (the container with the lowest
concentration) for 60 min  expose the sensors to the high concentration for 15 min  expose the sensors to the baseline concentration again for 30 min
Your sensors are now trained and are ready for the following verification steps.  expose the sensors to the quarter concentration for 5 min  expose the sensors to the half concentration for 5 min  expose the sensors to the high concentration for 5 min  expose the sensors to the baseline concentration again

(4) Expose the sensor for instance as shown in the pictures on the right; you should measure under a lid of sorts so that there is no convection; try to avoid using any glue in order not to add another VOC source

© Copyright Sensirion AG, Switzerland

Confidential

11

Step five: evaluation
You can now easily assess two key performance indicators of your SGP40 sensors: sensitivity and device-to-device variation (in case you have measured several sensors simultaneously).
1. Sensitivity: read out the difference in raw ADC tick values whenever the concentration is doubled (so going from half to high, or quarter to half concentration). If your sensors behave according to specifications this difference should be in the range of -710... - 1030 ticks.
2. Device-to-device variation: in the VOC index output, the different sensors should never be further apart than 15% (or 15 index points if below 100 index points)

© Copyright Sensirion AG, Switzerland

Confidential

12

Step five: evaluation example
The result should look something like this:
1. Sensitivity: we can read off the differences from quarter to half concentration as 24'239-25'345 = -1016, and the difference from half to high concentration as 23'590-24'329 = -739 so well within specifications.

SRAW_Px1

27500 27000 26500 26000 25500 25000 24500 24000 23500 23000

quick test: sensitivity

25345 24329 23590

X_DATA 183 368 553 738 923 1108 1293 1478 1663 1848 2033 2218 2403 2588 2774 2959 3144 3329 3514 3699 3884 4069 4254 4439 4624 4809 4994 5179 5364 5549 5734 5919 6104 6290 6475 6660 6845

duration (s)

© Copyright Sensirion AG, Switzerland

Confidential

13

Step five: evaluation example
The result should look something like this:
2. Device-to-device variation: the difference of the two sensors is barely discernible and well within specifications.

© Copyright Sensirion AG, Switzerland

Confidential

14