Introduction

Congratulations on your purchase of the A&D thermometer, one of the most advanced thermometers currently available. Designed for ease of use and accuracy, this device facilitates your health monitoring program. It is recommended to read this manual carefully before using the device for the first time.

Preliminary Notes

  • This device complies with European Directive 93/42 EEC for medical devices, indicated by the CE mark (CE 1639: Notified Body Identification Number).
  • Operating Environment: This device is designed for indoor use.
  • This device (infrared ear/forehead thermometer) measures infrared heat generated by the eardrum/temple area and surrounding tissues to accurately reflect the patient's body temperature.

Precautions

  • Precision components were used in the construction of this device. Keep it away from extreme temperatures, humidity, direct sunlight, water, shocks, or dust.
  • There are no age or gender limitations for the use of this infrared thermometer.
  • Do not allow children to use this device unsupervised, and do not leave it within reach of small children.
  • Intended User: At least 11 years of age (with 5 years of intensive reading experience), with no upper age limit.
  • This thermometer is designed for daily use. Its use does not replace a medical examination. Always compare the measurement results with your normal body temperature. Consult a doctor if you have concerns about your health.
  • Wireless communication devices, such as home network devices, mobile phones, cordless phones and their bases, and walkie-talkies, can interfere with this thermometer. Maintain a minimum distance of 3.3 meters (approx. 10.8 feet) from these devices.
  • Using the device near televisions, microwave ovens, X-rays, or other devices with strong magnetic fields may alter measurements.
  • This device contains small parts that could pose a choking hazard if accidentally swallowed by small children.
  • Not AP/APG (not suitable for use in the presence of flammable anesthetics or oxygen).

Symbols

  • ? Read instructions for use
  • ? Type BF Device
  • IP22 Classification of water and particle ingress
  • CE 1639 CE Directive label for medical device
  • EC REP EU Representative
  • [Stand-by]
  • [Battery Recycling] ♻️
  • [Paper Recycling] ♻️
  • ⚠️ Attention
  • WEEE Label
  • Manufacturer

Identification of Parts

Diagram showing the thermometer and its display icons:

  • Display Icons: Last Memory Icon (?), Surface Icon (?️), Forehead Icon (?), Battery Icon (?), Memory Icon (?), Unit of Measure Icon (°C/°F), Silent Icon (?), Ear Icon (?), Question Mark Icon (?).
  • Display Readings: Last Reading (e.g., 188.8).
  • Physical Parts: Cap ([Cap]), Stand-by (ON/MEM Button), SCAN Button, Display, A&D Medical Logo, Insulating Film ([Insulating Film]), Battery Cover ([Battery Cover]).
  • Serial Number Label: SN Byymmxxx (B: fixation, yy: year, mm: month, xxxx: production number).

Note: Before first use, remove the insulating film.

Functions

Ear Temperature

This thermometer is designed for daily use. Its use does not replace a medical examination. Always compare measurement results with your normal body temperature.

Forehead Temperature

This thermometer is designed for daily use. Its use does not replace a medical examination. Always compare measurement results with your normal body temperature. Consult a doctor if you have concerns about your health.

Ambient Temperature

The correct ambient temperature is crucial for the health of a newborn or patient. The thermometer helps to recognize the ambient temperature.

Surface Mode

Surface mode displays the current surface temperature, which differs from body temperature. It can help verify if an object's temperature is suitable for a newborn or patient (e.g., milk to be given to a newborn).

Fever Indication

If the thermometer detects a body temperature above 37.5°C (99.5°F), a long beep will sound, followed by three short beeps, to alert the user of a potential fever.

Last Reading

When a new temperature reading is taken in ear or forehead mode, the last reading will be displayed in the upper right corner of the screen, accompanied by the last reading icon.

Memory Location

Up to 25 ear measurements can be stored in memory. Once the device is on, press the "ON/MEM" button to view stored temperatures, indicated by the memory icon.

Switching °C / °F

In "Off" mode, press and hold the “SCAN” button, then press the “ON/MEM” button for 3 seconds. The temperature unit icon will change from “°C” to “°F”. Use the same process to switch from °F to °C.

Silent Mode

By default, the audible signal is active. You can activate/deactivate the audible signal in silent mode. With the device on, press and hold the “ON/MEM” button for 3 seconds. The silent icon (?) will flash on the display. Release the “ON/MEM” button to activate silent mode. No beep will be heard from this point on. Use the same process to deactivate silent mode.

NOTE: If the silent icon appears and you continue to press the “ON/MEM” button for 5 seconds, the device will turn off WITHOUT setting silent mode.

Automatic Power-Off

If not used for more than 1 minute, the device will automatically turn off (stand-by). The device also turns off automatically after use.

Battery Installation/Replacement

  1. Open the battery cover: Ensure the thermometer is in "forehead mode". Insert a coin into the rotating cover on the back of the device and turn it clockwise. The battery is located under the cover.
  2. Hold the device and remove the battery with a small screwdriver.
  3. Insert the new battery under the metal hook on the left side and press the right side of the battery until it clicks.
  4. Replace the battery cover.

Diagram showing battery compartment and insertion:

  • Illustration shows a coin slot on the battery cover.
  • Diagrams show the CR2032 battery with '+' and '-' terminals.
  • ⚠️ ATTENTION
  • Keep the battery away from children. (This device uses a CR2032 lithium battery.)
  • Keep the positive (+) side facing up and the negative (-) side facing down.
  • Dispose of used batteries according to local regulations.

Measurement

  1. Always ensure the probe is clean and undamaged.
  2. Power On: Press the “ON/MEM” button.
  3. Mode Selection:
    • Ear Mode: ? Press the “ON/MEM” button. The thermometer defaults to ear mode. It is ready for use after the ear icon is displayed and two beeps are heard. In this mode, you can measure body temperature via the ear.
    • Forehead Mode: ? Once the device is on, press and hold the “ON/MEM” button and press the “SCAN” button once to switch to forehead mode. The forehead icon will be displayed, and two beeps will sound. In this mode, you can measure body temperature via the forehead.
    • Surface Mode: ?️ Once the device is on, press and hold the “ON/MEM” button and press the “SCAN” button once to switch to surface mode. The surface icon will be displayed. In this mode, you can measure the surface temperature of an object.
  4. Temperature Measurement:

    Ear Temperature Measurement. Pay attention:

    1. Gently pull the ear backward to straighten the ear canal and comfortably position the probe inside the ear canal, aiming towards the eardrum for an accurate reading.
    2. Press and hold the “SCAN” button until a beep is heard. Remove the ear probe and read the temperature measurement on the LCD display.

    Diagram illustrating ear measurement: Shows pulling the ear back (Tirare) and scanning (Scansionare).

    Forehead Temperature Measurement. Pay attention:

    1. The temporal artery, a large artery leading to the skull, is connected to the heart via the carotid artery. This thermometer is designed to measure the skin surface temperature around the temporal artery.
    2. Position the thermometer on the temple (see image). You can choose either the left or right temple.
    3. Press the “SCAN” button and gently scan the temple area. During scanning, the device emits a scanning sound, indicating measurement is in progress. Measurement is complete when the forehead icon stops flashing after a short beep. Measurement may take 5-8 seconds up to 30 seconds, depending on how long it takes the device to detect the correct forehead temperature.

    Diagram showing the forehead measurement area.

    Surface Temperature Measurement:

    1. When the “SCAN” button is pressed, the real-time temperature is immediately obtained. If you hold down the “SCAN” button, the measurement will be continuously updated.
    2. This mode can be used to measure the temperature of water, milk, clothing, skin, or other objects.

    NOTE: This mode displays actual, unadjusted surface temperatures, which differ from body temperature.

  5. After Measurement:
    • (1) Power Off: If not used for more than 1 minute, the device will automatically turn off (stand-by). The device also turns off automatically.
    • (2) Cleaning: Clean the probe after each use to obtain accurate readings and prevent indirect contamination. (For more details, see the "Care and Maintenance" section.)
    • (3) Display: The device always indicates the ambient temperature in stand-by mode, and it is not possible to turn off all display visualizations on the LCD.

NOTE: This thermometer is designed for daily use. Its use does not replace a medical examination. Always compare measurement results with your normal body temperature. Consult a doctor if you have concerns about your health.

If the thermometer is held too long, the probe may read a higher ambient temperature, consequently resulting in a lower body temperature measurement than usual.

Troubleshooting

ErrorProblemRecommended Action
Er 5 - 9System not functioning adequately.Remove the battery, wait 1 minute, and reinsert it. If this message reappears, contact your retailer for assistance.
Er 1Measurement before device stabilization.Wait until the icon stops flashing before taking a measurement.
ALHAmbient temperature is > 40°C (104°F)Leave the thermometer stationary for at least 15 minutes in a room with an ambient temperature between 10°C and 40°C (50°F and 104°F).
ALLAmbient temperature is < 10°C (50°F)Leave the thermometer stationary for at least 15 minutes in a room with an ambient temperature between 10°C and 40°C (50°F and 104°F).
HEar/Forehead Mode: Temperature obtained is above +42.2°C (108°F)
Surface Mode: Temperature obtained is above +80°C (176°F)
Select a target within specifications. If the malfunction persists, contact your nearest retailer.
LoEar/Forehead Mode: Temperature obtained is below +34°C (93.2°F)
Surface Mode: Temperature obtained is below -22°C (-7.6°F)
Select a target within specifications. If the malfunction persists, contact your nearest retailer.
Display shows 188.8 with °C/°F and other iconsCannot turn on the device and set it to a ready-to-use state.Replace the battery with a new one.

⚠️ ATTENTION

Do not open this device. If a problem occurs that is not covered in these instructions, contact the retailer or customer support.

Care and Maintenance

  • After measurement, use a cotton swab soaked in alcohol (70% concentration) to clean the lens (inside the probe).
  • Allow the probe to dry completely for several minutes. Then, replace the cap.
  • Store this device at temperatures between -20°C and +50°C (-4°F and 122°F) and in an environment with a maximum humidity (RH) of 85%.
  • Keep this device dry and away from any liquids and direct sunlight.
  • Do not immerse the probe in any liquid.

NOTE

  • The probe is the most delicate part of the thermometer. Handle it with care when cleaning the lens to avoid damage.
  • Check the device for damage in case of a fall. If you are unsure how to check it, take the complete device to your nearest retailer for possible recalibration.
  • If the thermometer is held too long, the probe may read a higher ambient temperature, consequently resulting in a lower body temperature measurement than usual.

Technical Data

SpecificationsDetails
Dimensions125 mm × 37 mm × 22 mm
WeightApprox. 41 g, excluding battery.
Temperature Measurement RangeEar/Forehead Mode: 34 to 42.2°C (93.2 to 108°F)
Surface Mode: -22 to +80°C (-7.6 to 176°F)
Operating Temperature Range10 to 40°C (50 to 104°F), 15 to 85% RH
Storage Temperature RangeStore the device at an ambient temperature between -20 and +50°C (-4 to 122°F) with a maximum humidity (RH) of 85%.
Transport: <70°C, RH≤95%, Atmospheric Pressure: 800 to 1013hPa.
AccuracyEar/Forehead Mode: ±0.2°C (0.4°F) for temperatures between 35 and 42°C (95 to 107.6°F) (Ambient Temp: 15 to 35°C), ±0.3°C (0.5°F) for other ranges.
Surface Mode: ±0.3°C (0.5°F) for temperatures between 22 and 42°C (71.6 to 108°F), for others ±4% or 2°C (4°F), whichever is greater.
Memory25 memory settings and last measurement.
BatteryCR2032 × 1
  • Battery life: approx. 3000 continuous readings. Expected lifespan: 4 years.
  • This thermometer converts forehead/ear temperatures to an "oral equivalent" value.
  • This device complies with ASTM E1965-98, EN ISO80601-2-56, IEC/EN60601-1-2 (Electromagnetic Compatibility (EMC)), and IEC/EN60601-1 (Safety), ISO10993, RoHS.

NOTE: Specifications are subject to change for improvement without prior notice.

Contact Information

A&D Company, Limited
3-23-14, Higashi-Ikebukuro, Toshima-ku Tokyo 170-0013 JAPAN
http://www.aandd.jp

A&D INSTRUMENTS LIMITED
Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire OX14 1DY United Kingdom
Telephone: [44] (1235) 550420 Fax: [44] (1235) 550485

A&D Australasia Pty Ltd.
32 Dew Street, Thebarton, South Australia 5031 AUSTRALIA
Telephone: [61] (8) 8301-8100 Fax: [61] (8) 8352-7409

A&D Instruments India Private Limited
509 Udyog Vihar Phase V Gurgaon-122 016, Haryana, India
Tel: 91(124)471-5555 Fax: 91(124)471-5599

Radiant Innovation Inc.
Http://www.radiantek.com.tw
1F, No.3, Industrial E. 9th Rd., Science-Based Industrial Park, HsinChu 300, Taiwan

EC REP Medical Technology Promedt Consulting GmbH
Altenhofstrasse 80, D-66386 St. Ingbert, Germany

CE 1639

Models: UT-801, Multi-function Infrared Thermometer

File Info : application/pdf, 15 Pages, 761.98KB

PDF preview unavailable. Download the PDF instead.

ut801 it pdf as iTextSharp™ 5.5.9 ©2000-2016 iText Group NV (AGPL-version)

Related Documents

Preview A&D Medical UT-801 Multi-function Infrared Thermometer User Manual
Comprehensive instruction manual for the A&D Medical UT-801 multi-function infrared thermometer, covering features, operation, safety precautions, troubleshooting, and technical specifications for accurate temperature measurement.
Preview A&D Medical UT-801 Multi-function Infrared Thermometer Instruction Manual
Instruction manual for the A&D Medical UT-801 multi-function infrared thermometer, covering features, operation, precautions, and technical specifications.
Preview A&D Medical UB-510 Wrist Digital Blood Pressure Monitor User Manual
Comprehensive user manual for the A&D Medical UB-510 Wrist Digital Blood Pressure Monitor. Learn about setup, operation, measurement, troubleshooting, and technical specifications.
Preview A&D UB-525 Wrist Digital Blood Pressure Monitor Instruction Manual
User manual for the A&D UB-525 Wrist Digital Blood Pressure Monitor, providing instructions on setup, usage, measurements, troubleshooting, and technical specifications for accurate home health monitoring.
Preview A&D TM-2657P Automatic Blood Pressure Monitor Instruction Manual
This instruction manual provides detailed guidance on the A&D TM-2657P Automatic Blood Pressure Monitor. Learn about its features, safe operation, measurement procedures, maintenance, and technical specifications for accurate health monitoring.
Preview A&D Ambulatory Blood Pressure Monitoring System TM-2440 & TM-2441 Quick Start Guide
A quick start guide for the A&D Medical Ambulatory Blood Pressure Monitoring System, models TM-2440 and TM-2441. This guide covers software installation, battery insertion, monitor connection, programming, patient preparation, data download, and report generation.
Preview A&D TM-2440 Ambulatory Blood Pressure Monitor Instruction Manual
Comprehensive instruction manual for the A&D TM-2440 Ambulatory Blood Pressure Monitor, detailing its features, operation, maintenance, and safety precautions for accurate blood pressure monitoring.
Preview A&D UA-1030T Talking Blood Pressure Monitor - Features, Specs, and Support
Learn about the A&D UA-1030T Talking Blood Pressure Monitor, featuring TriCheck technology, SmoothFit cuff, verbal instructions in English, French, and Spanish, and detailed technical specifications for accurate home health monitoring.