User Manual for LECTRON models including: V-BOX PRO 48A, V-BOX PRO 48A EV Charging Station, EV Charging Station, Charging Station, Station
V-Box Pro 48A – Qmerit
V-Box Pro 48A – Raiven on Behalf of APG Construction
File Info : application/pdf, 13 Pages, 928.87KB
DocumentDocumentV-BOX PRO 48A EV Charging Station USER MANUAL CONTENTS What's Included ............................................................................................................................................................ 3 Safety Instructions ....................................................................................................................................................... 4 LED Status Indicators ................................................................................................................................................ 5 Before Installation ........................................................................................................................................................ 7 Installation Guide ......................................................................................................................................................... 8 Hardwiring the V-BOX Pro .................................................................................................................................... 10 Charging Your Vehicle .............................................................................................................................................. 11 Disconnecting Your Vehicle .................................................................................................................................. 11 Specifications .................................................................................................................................................................. 12 Get More Support ........................................................................................................................................................ 13 Charging handle Tesla | NACS Tesla charger mount COMPATABILITY NEMA 14-50 (240 V) Tesla | NACS Connector 3 SAFETY INSTRUCTIONS · It is highly recommended that the installation of electrical outlets for use with the V-BOX Pro Charging Station be conducted by a licensed and qualified electrician. The installation should adhere to the National Electric Code (NEC) and relevant local codes, with local codes taking precedence in case of conflicts. · Proper grounding is essential. The grounding conductor and plug provided with the V-BOX Pro should be connected to a correctly installed and grounded outlet, reducing the risk of electric shock. · Avoid dropping or causing damage to the charging station and charging handle. · Do not attempt any repairs on the V-BOX Pro. For assistance, please contact customer support at contact@ev-lectron.com. · Follow these precautions when using the V-BOX Pro Charging Station: - Do not use the station with an extension cord or AC adapter. - Ensure the plug is fully inserted into the wall outlet to prevent exposed prong surfaces. - Supervise children when the station is in use. - Only connect to a circuit with a maximum of 60 amps branch circuit overcurrent protection to minimize the risk of fire. WARNING: a) Read all instructions before using this product. b) Do not insert fingers into the electric vehicle connector. c) Do not use this product if the flexible power cord or EV cable is frayed, has broken insulation, or shows any other signs of damage. d) Do not use this product if the enclosure or the EV connector is broken, cracked, open, or shows any other indication of damage. 4 LED STATUS INDICATORS Status indications are displayed on the V-shaped LED of the V-BOX Pro Charging Station. The Power Button LED on the right-hand side of the unit indicates if the charging station is switched on. FUNCTION & STATUS INDICATION (V-SHAPED LED) FUNCTION STATUS LED COLOR (Red) (Blue) (Green) No connection to EV Connected to EV, communication in progress Charging in progress Charging complete Error/Warning POWER BUTTON (RIGHT SIDE OF STATION) BUTTON POSITION OFF ON LED COLOR (Red) (Blue) (Green) V-BOX PRO DIAGRAM V-shaped LED Power button 5 ERROR INDICATION (V-SHAPED LED) FAULT STATUS Control pilot fault Input UVP (Under Voltage Protection) Input OVP (Over Voltage Protection) OTP (Over Temperature Protection) OCP (Over Current Protection) Ground fault Relay fault RCD (Residual Current Device) Abnormal RCD self-test fault RED LED 1 flash followed by 2 seconds off, repeating 2 flashes followed by 2 seconds off, repeating 3 flashes followed by 2 seconds off, repeating 4 flashes followed by 2 seconds off, repeating 5 flashes followed by 2 seconds off, repeating 6 flashes followed by 2 seconds off, repeating 7 flashes followed by 2 seconds off, repeating Blinking Solid 6 BEFORE INSTALLATION To adjust the charging current (Amps) on the V-BOX PRO: 1 1. Remove the cover on the back of the V-BOX PRO. 2. Locate the dial and turn it to your desired charging current setting. Please note that the default current setting is 40A. Increasing the charging current to 48A will require hardwiring. Charging current dial 2 Charging current dial on rear of V-BOX Pro Dial Position Current (A) 0 16 A 1 32 A 2 40 A 3 48 A 7 INSTALLATION GUIDE 1. Use the drilling reference paper to mark the wall for the mounting plate's location. 3. Insert wall anchors, align the mounting plate, and attach it firmly. 2. Drill holes at the marked positions using the correct drill and bit size. 8 5. Align V-BOX Pro slots with mounting plate tabs, adjust Amp setting, and attach. 7. Connect the power cable to a NEMA 14-50 outlet. Please note, the unit must be hardwired for 48A; do not use the plug. 6. Reinsert V-BOX Pro screws, conceal with screw caps. 9 HARDWIRING THE V-BOX PRO Prior to any hardwire installation, deactivate the circuit breaker associated with the relevant electrical circuit. The hardwiring process should be conducted by an electrician with the necessary qualifications. NOTE: Grounding Instructions This product must be connected to a grounded, metal, permanent wiring system. Alternatively, an equipment grounding conductor should be run with the circuit conductors and connected to the equipment grounding terminal or lead on the product. 10 CHARGING YOUR VEHICLE Important: Prior to charging, ensure your vehicle is parked and turned off. 1. Attach the charging handle to your vehicle's charging port. DISCONNECTING YOUR VEHICLE 1. Solid green LEDs indicate charging is complete. To disconnect, press the button on top of the charging handle. 2. Power on the V-BOX Pro by pressing the button located on the right side of the unit. 3. Successful charging is indicated by `rolling green' LEDs on the V-BOX Pro. Verify the status on your vehicle's dashboard. 11 SPECIFICATIONS Maximum current: Current settings: Input / output: Frequency: Cable length: Plug: EV connector: Dimensions: Weight: Operating temperature: Material: Storage temperature: APPROVED · IP65 TESTED & 48 A 16 A, 32 A, 40 A(default setting: NEMA plug), 48 A(Hardwired) 208 - 240 V AC 50 / 60 Hz 16 ft NEMA 14-50 North American Charging Standard (NACS) | Tesla 17.x 13.77 x 10.43 in 20.5 lb -22 °F to 122 °F (-30 °C to 50 °C) PC and alloy -40 °F to 176 ° (-40 °C to 80 °C) IP65 TESTED & APPROVED · IP65 TESTED & APPROVED · APPROVED · IP65 TESTED & 12 GET MORE SUPPORT Need assistance? Scan the QR code below or email us at contact@ev-lectron.com www.ev-lectron.com Made in China