Instructions for BEA models including: LZR-MICROSCAN T Door Control Wiring Matrix, LZR-MICROSCAN T, Door Control Wiring Matrix, Control Wiring Matrix, Wiring Matrix, Matrix
Products and Accessories Archives | BEA Sensors
File Info : application/pdf, 3 Pages, 377.73KB
DocumentDocumentAPPLICATION NOTE DOOR CONTROL WIRING MATRIX LZR-MICROSCAN T BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/gates, and factory-trained for the type of door/gate system. Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards. Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer's recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code). Verify that all appropriate industry signage, warning labels, and placards are in place. 78.6023.02 LZR-MICROSCAN WIRING MATRIX 20240214 Page 1 of 4 Pwr Harness (20.5095) R Bk G Besam ETIK 4 Besam MP/CUP Besam PowerSwing/EXB Besam SM 900/CU2 Assa Abloy SW 100/200, Ditec HA9 5 CONDOR DCU DC700 Access Auto. ES500 Quad Systems ES500 Detex BS1000S/UDC100 Dor-O-Matic Dorma 400/700 Dorma ED 100/250 6 Gyrotech/Nabco Magnum Gyrotech/Nabco Opus Gyrotech/Nabco U19 Gyrotech 300/400 7 Horton 4160-3 8 Horton 4190 Horton 5190 9 Hunter HA, Ditec HA8 Keane-Monroe K LCN Digital / Senior Swing Record 6000/8000 10 Stanley "L" 11 Stanley MP Stanley MC 521 12 Stanley MC 521 Pro and IQ 12 Tucker Tormax 130iMotion Tormax TDA Tormax TTX II Page 2 of 4 POWER 1 30.5558 30.5558 30.5558 30.5558 24V+ GND 30.5558 30.5558 30.5558 30.5558 30.5558 1 3 30.5558 30.5558 30.5558 30.5558 30.5558 30.5558 30.5558 30.5558 30.5558 30.5558 4 6 30.5558 30.5558 30.5558 TB4-5 TB4-6 30.5558 30.5558 30.5558 30.5558 ACT (N.O.) 13 3 TB3-21 1 CU-ESD 2 ACTIVATE 17 CN2 #2 2 YELLOW TRIGGER 42 6 BLACK 3 61/62 BLACK BLACK 2 CN20 2 = interior 3 = exterior ACT GREEN P6 YELLOW 2 ORANGE 2 TB4-4 TB4-4 J4-10 INPUT C #2 2 5 Door Control Harness (20.5222) G Y Y W R R ACT (N.C.) ACT (COM) STALL (N.O.) STALL (N.C.) 12 4 TB3-20 3 5 TB1-7 15/17 TB4-29 CU-ESD 1 EXU-SA 3 COM 16 DMS O W R STALL (COM) 16/18 4 TB4-26 3 EXU-SA1 COMMON N O HOME see note 2 System Harness (20.5304) Gy P O Gy Bl HOME see note 2 PUSH PLATE MONITORING 3 DPS Not supported. DPS Not supported. DPS Not supported. DPS EXU-SA 7 EXU-SA 8 Not supported. Refer to BEA product User's Guide and OEM manual. DPS Not supported. CN2 #3 CN6 GREEN CN6 BLACK DPS Not supported. 1 GRAY GND 5 PURPLE SWING 1 GRAY GND 3 15 3 5 RED 3 VIOLET 5 RED 2 5 2 RED 7 RED WHITE 3 WHITE 6B WHITE DAUGHTER BOARD 10 RED 7 RED DAUGHTER BOARD 3 CN7 COM CN16 ORANGE (10) CN16 YELLOW (9) RTN WHITE P6 GRAY SAFE 2 YELLOW P2 GREEN RTN WHITE P2 WHITE 1 10 11 YELLOW 8 BLUE 7 YELLOW 8 TB4-3 TB3-4 TB3-3 TB4-3 J4-8 jumped to 12 & 13 INPUT C #1 8 4 TB3-4 SAFETY A #2 7 J4-14 TB3-3 J4-8 jumped to 12 & 13 SAFETY A #1 8 14 78.6023.02 LZR-MICROSCAN WIRING MATRIX 20240214 DPS DPS DPS 97 98 DPS DPS DPS DPS DPS DPS DPS DPS DPS DPS DPS DPS DPS see note 3 see note 3 J5 - 4 and 5 DPS DPS DPS Connect any dry-contact, knowing act deevice to the 2 gray wires. Be certain to turn on Knowing Act at the hub. Not supported. Not supported. Not supported. Refer to BEA product User's Guide and OEM manual. Not supported. Refer to BEA product User's Guide and OEM manual. Not supported. Not supported. Not supported. Not supported. Not supported. Not supported. Not supported. Not supported. Refer to BEA product User's Guide and OEM manual. Not supported. Not supported. Refer to BEA product User's Guide and OEM manual. Refer to BEA product User's Guide and OEM manual. Not supported. Refer to BEA product User's Guide and OEM manual. Not supported. Not supported. Page 3 of 4 Note 1 Note 2 Note 3 If only VAC power is available, a 12V transformer paired with a rectifier must be used. Do not use a 24V transformer and rectifier as this will cause damage to the product. Auxiliary Switch: If installing onto a pair or double-egress, ensure to series both home switches. Switches must close when door is closed. Monitoring consists of two purple and two blue wires. If monitoring is not used, cap off unused purple and blue wires. Wire as follows: Door Type System Harness Control Monitoring Single 1 blue + 1 purple 1 blue + 1 purple 1st leg 2nd leg Pair / Dual Egress 1 blue + 1 purple 1 blue + 1 purple 1st leg 2nd leg Pair / Dual Egress (independent controls) 2 blues 2 purples 1st control 2nd control Effective November 11, 2017: Monitoring is required for ANSI 156.10 compliance. Note 4 Jump 17+18, if not used. (BESAM ETIK) Note 5 Set EXU-SA jumper to "Door open/closed" indication. (BESAM SW 100/200, Ditec HA9) Jump 1+2 on EXU-SA board. Blanking Potentiometer must be set fully counterclockwise. Auxiliary switch may be used for home switch. Note 6 Jump 11+3 on ontrol. (DORMA ED 100/250) Use ON/OFF/H.O. jumper. Control switches must be used. Make certain Home Switch Control Function "Sr" is set to 1. Note 7 Set control to "swing-safe." (GYROTECH 300/400) Note 8 Must have daughter board. (HORTON 4160-3) Note 9 If using the MICROSCAN On/Off/Hold switch, BEA recommends using CN20 terminal 2. (HORTON 5190) The CN1 harness will sync two operators so you do not have to use both door control "a" and "b" harnesses. Note 10 Jump 11+12 and 14+15. (RECORD 6000/8000) Note 11 The older Stanley, all metal (silver), "L" shape control does not have stall. A control (STANLEY "L") with stall must be used. Note 12 Jump TB2 2+3 (if not using factory On/Off/Hold Switch). (STANLEY MC521 / MC521 PRO and IQ) Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 General Tech Questions: techservices-us@BEAsensors.com | www.BEAsensors.com Page 4 of 4 78.6023.02 LZR-MICROSCAN WIRING MATRIX 20240214