Model: 02020CA
Congratulations on your new AcuRite product. Please read this manual in its entirety and retain it for future reference.
Remove the protective film applied to the LCD screen before use. Locate the tab and peel it off.
Register online to receive 1 year of warranty protection at www.AcuRite.com.
IMPORTANT: Product must be registered to receive warranty service.
Under no circumstances shall the Lightning Detector, Chaney Instrument Co., or the Primex Family of Companies be held responsible for any damages resulting from the use of or inability to use this product. This includes indirect, incidental, special, exemplary, or consequential damages. This disclaimer applies to damages or injury caused by performance failure, error, omission, inaccuracy, interruption, deletion, defect, delay, software virus, communication failure, theft, destruction, or unauthorized access, alteration, or use of the product, whether for breach of contract, tortuous behavior, negligence, or any other cause of action, to the fullest extent permissible by law. This does not affect statutory rights. The contents of this product, including all lightning and weather data, are provided "as is" without warranty of any kind, express or implied. Chaney Instrument Co. & the Primex Family of Companies do not warrant that this product or its data will be free of errors, interruptions, viruses, or other harmful components. They also do not warrant the accuracy or reliability of any lightning strike alerts or weather data. Chaney Instrument Co. & the Primex Family of Companies reserve the right to alter the product or withdraw it from the market at their sole discretion.
AcuRite recommends high-quality alkaline batteries for best performance. Heavy-duty or rechargeable batteries are not recommended.
Press the "miles/km" button located inside the battery compartment area to select between miles or kilometers.
Press the "english/français" button located inside the battery compartment area to select between English and French.
WARNING: Please dispose of old or defective batteries in an environmentally safe way and in accordance with your local laws and regulations.
Battery Safety: Clean battery contacts and device contacts before installation. Remove batteries from equipment not used for extended periods. Follow polarity diagrams. Promptly remove dead batteries. Dispose of used batteries properly. Use only recommended battery types. Do not incinerate, dispose of in fire, mix old/new batteries or types, use rechargeable batteries, recharge non-rechargeable batteries, or short-circuit terminals.
Press the power button [⏻] to turn the detector ON. The display will show "PLEASE WAIT" during automatic calibration. Once complete, "LISTENING.." will display. Press and hold the power button [⏻] for 3 seconds to turn the detector OFF.
Outdoor mode is the default. Indoor Mode optimizes performance by reducing sensitivity to interference. To select indoor mode, press and hold the [LIGHT] and [POWER] buttons for 2 seconds until a beep is heard. The display will show "INDOOR". The detector returns to outdoor mode when powered off.
The device detects cloud-to-cloud, cloud-to-ground, and intra-cloud lightning. When detected, the device emits two beeps ? and the red LED flashes ?. The display shows "STRIKES DETECTED!", a running count, and the estimated distance to the storm front. Alerts repeat every 5 seconds until 30 minutes of inactivity. The count resets when the device is powered off.
The detector uses advanced technology to distinguish lightning from interference. In rare cases, interference may cause a "false detect." If this occurs, verify there is no lightning in the area, then relocate the detector. If false detections persist, identify and relocate the source of interference or relocate the detector.
Audio alerts ? are enabled by default. They can be temporarily silenced for up to 60 minutes. To silence, press and hold the [LIGHT] button for 5 seconds; the display will show "MUTED". Visual alerts (LED and display messages) remain active. If a strike occurs while muted, the display will show "STRIKES DETECTED! MUTED" along with visual indicators. Audio alerts will re-enable automatically after 60 minutes or when the [LIGHT] button is held for 5 seconds again (displaying "SOUND ON").
The detector has enhanced interference rejection to prevent false lightning detection. If interference prevents detection, the detector sounds a single beep and displays "UNABLE TO DETECT...PLEASE RELOCATE." Use the detector at least 3 feet (0.9 m) away from potential interference sources, including:
WARNING: Take shelter IMMEDIATELY when lightning is present, regardless of whether it has been detected. Do not rely solely on this Lightning Detector for warnings about potentially deadly lightning strikes or severe weather conditions.
Text on Display | Alerts | Message |
---|---|---|
STRIKES DETECTED! | 2 beeps & light flashes | Lightning has been detected within 25 miles. |
INDOOR | None | Confirms the detector is set to operate indoors. |
LISTENING.. | None | Detector is ready for use. |
LO BATTERY. | ? icon & 1 beep/minute | Replace batteries. |
NA | None | Lightning detected beyond 25 miles. |
PLEASE WAIT | None | Detector is calibrating itself. |
UNABLE TO DETECT...PLEASE RELOCATE | 1 beep | Interference detected; use the detector in a different location. |
MUTED | None | Audio alerts temporarily silenced. Press and hold the [LIGHT] button for 5 seconds to re-enable audio alerts. |
If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call (877) 221-1252 for assistance.
The detector is weather resistant but not intended for direct exposure to rainfall. Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.
Parameter | Value |
---|---|
OPERATING TEMPERATURE | 32°F to 140°F; 0°C to 60°C |
LIGHTNING DETECTION RANGE* | 1 - 25 miles / 1.6 - 40km |
LIGHTNING COUNTER | Counts up to 199 strikes (power off to reset counter) |
AUDIBLE TONE | 85 decibels |
POWER | 2 x AAA alkaline batteries (not included) |
BATTERY LIFE EXPECTANCY | 8-10 months (based on an average of 3 lightning strikes detected per day) |
*To select between miles or kilometers, press the "miles/km" button located inside the battery compartment area.
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions: 1) This device may NOT cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference received, including interference that may cause undesired operation of the device.
AcuRite customer support is committed to providing best-in-class service. For assistance, please have the model number of this product available and contact us:
AcuRite upholds its commitment to quality technology. Chaney Instrument Co. warrants that its products will be of good material and workmanship, and free of defects when properly installed and operated for one year from the date of purchase.
Product registration at www.AcuRite.com is recommended for the fastest warranty service, but does not eliminate the need to retain your original proof of purchase.
Warranty Terms: Remedy is limited to repair or replacement of defective items. Products proven defective within one year under normal use and service will be repaired or replaced by Chaney at its sole option. Purchaser pays transportation costs for returned goods. Chaney disclaims responsibility for these costs.
Exclusions: This warranty does not cover normal wear and tear, damage (including acts of nature), tampering, abuse, improper installation, shipping damage, or repairs/alterations by unauthorized representatives.
Disclaimer: This warranty is expressly in lieu of all other warranties, express or implied, including implied warranties of merchantability and fitness for a particular purpose. Chaney expressly disclaims liability for special, consequential, or incidental damages. Some states may not allow these limitations. Chaney disclaims liability for personal injury relating to its products to the extent permitted by law. By accepting Chaney's products, the purchaser assumes all liability for consequences arising from their use or misuse.
No person or entity is authorized to assume other liability for Chaney or modify/waive these terms without written consent signed by a duly authorized agent.
This warranty gives you specific legal rights, and you may have other rights that vary by state.
For in-warranty claims: Chaney Instrument Co., 965 Wells St., Lake Geneva, WI 53147
AcuRite offers a wide range of precision instruments:
It's more than accurate, it's ACU RITE. AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to Plan your day with confidence™.
Visit www.AcuRite.com
Printed in China. Model: 02020CA INST 101415
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.
Models: 02020CA, Lightning DetectorFile Info : application/pdf, 10 Pages, 1.07MB
DocumentDocument![]() |
AcuRite Lightning Detector Model 02020 Instruction Manual Instruction manual for the AcuRite Lightning Detector Model 02020, covering setup, operation, features, troubleshooting, and warranty information. |
![]() |
AcuRite 01036 Professional Weather Center Instruction Manual Detailed instructions for the AcuRite 01036 Professional Weather Center. Covers setup, features, operation, troubleshooting, care, and specifications for accurate home weather monitoring. |
![]() |
AcuRite 00787 Wireless Weather Station: Setup, Operation, and Specifications Comprehensive instruction manual for the AcuRite 00787 Wireless Weather Station. Learn how to set up the wireless thermometer, synchronize the atomic clock, use the weather forecaster, and understand its features and specifications. |
![]() |
AcuRite 06034 Rain Gauge: Instruction Manual and Setup Guide Comprehensive guide for the AcuRite 06034 Rain Gauge, covering setup, installation, calibration, troubleshooting, and care. Learn how to accurately measure rainfall with your AcuRite device. |
![]() |
AcuRite Iris™ (5-in-1) Weather Station with Lightning Detection - Instruction Manual Comprehensive instruction manual for the AcuRite Iris™ (5-in-1) Weather Station, covering setup, operation, features, troubleshooting, and specifications for models 01022, 02080, and 06046. Learn how to install, configure, and maintain your weather station for accurate local weather forecasting and lightning detection. |
![]() |
AcuRite 01121 Weather Station Instruction Manual Comprehensive instruction manual for the AcuRite 01121 Weather Station, covering setup, operation, features, troubleshooting, and specifications. Learn how to get the most accurate readings and use all the functions of your weather station. |
![]() |
AcuRite Iris 5-in-1 Weather Station: Setup, Wi-Fi, and User Guide Get started with your AcuRite Iris 5-in-1 Weather Station. This guide covers Wi-Fi setup, sensor installation, calibration, and troubleshooting for accurate home weather monitoring. |
![]() |
AcuRite 5-in-1 Weather Sensor (Model 06004RM/VN1TXC) - Instruction Manual and Setup Guide Comprehensive instruction manual for the AcuRite 5-in-1 Weather Sensor (Model 06004RM/VN1TXC). Learn about features, setup, installation, placement, calibration, specifications, and customer support from Chaney Instrument Co. |