User Manual for APstorage models including: ELS Series PCS SeaFamily, ELS Series, PCS SeaFamily, SeaFamily

沐子

Library – APsystems Global | The global leader in multi-platform MLPE technology

APstorage Sea Family ELS Series PCS Installation & User Manual


File Info : application/pdf, 52 Pages, 4.59MB

PDF preview unavailable. Download the PDF instead.

4304405111 APstorage-ELS-Series-PCS-User-Manual(NA) REV3.4 2023-03-30
APstorage Sea Family ELS Series PCS
Installation & User Manual
For North America
Rev3.4 2023-03-30 © All Rights Reserved

Table of Contents
1. Important Safety Instructions ........................................................................................................... 2
1.1 Safety Instructions .....................................................................................................................................................2 1.2 Radio Interference Statement .................................................................................................................................. 3 1.3 Communication Disclaimer ....................................................................................................................................... 3 1.4 Symbols replace words on the equipment, on a display, or in manuals ................................................................. 3
2. APstorage PCS Introduction .............................................................................................................. 4
2.1 Dimensions ................................................................................................................................................................ 4 2.2 Basic System Architecture .........................................................................................................................................5 2.3 Back-up Load Configuration ......................................................................................................................................6 2.4 LED ............................................................................................................................................................................. 7 2.5 PCS Connection Port ................................................................................................................................................. 8
3. Installation ....................................................................................................................................... 9
3.1 Packing List ................................................................................................................................................................ 9 3.1.1 PCS Packing List .............................................................................................................................................. 9 3.1.2 Transformer (T-A) Packing List .....................................................................................................................10
3.2 Select Mounting Location ....................................................................................................................................... 11 3.3 PCS Installation Steps .............................................................................................................................................. 12 3.4 Transformer Installation Steps ................................................................................................................................12 3.5 PCS Wiring ............................................................................................................................................................... 13
3.5.1 DC Wiring ......................................................................................................................................................14 3.5.3 Transformer Wiring ......................................................................................................................................15 3.5.4 Communication Wiring ................................................................................................................................ 17 3.5.5 CT Wiring ...................................................................................................................................................... 18 3.6 Install the Lower Cover ........................................................................................................................................... 19 3.7 PV System to APstorage Pairing ..............................................................................................................................19 3.8 Wiring Diagram ....................................................................................................................................................... 20 3.9 Parallel Wiring Diagram .......................................................................................................................................... 21 3.10 PCS Parallel Wiring Steps ...................................................................................................................................... 22 3.11 Start-up sequence ................................................................................................................................................. 23 3.11.1 Power ON ................................................................................................................................................... 23 3.11.2 Check the system ....................................................................................................................................... 23 3.11.3 Power Off ................................................................................................................................................... 23
4. APstorage User Interface ................................................................................................................ 24
4.1 Configure APstorage with EMA Manager ...............................................................................................................24 4.2 Home Page .............................................................................................................................................................. 26 4.3 Module .................................................................................................................................................................... 28 4.4 Data ......................................................................................................................................................................... 29 4.5 Workbench .............................................................................................................................................................. 32 4.6 Settings .................................................................................................................................................................... 49
5. Technical Data ................................................................................................................................ 50 6. Contact Information ....................................................................................................................... 51
APstorage Installation / User Manual

1. Important Safety Instructions

This manual contains important instructions to be followed during installation and maintenance of the APstorage PCS. To reduce the risk of electrical shock and ensure the safe installation and operation of the APstorage PCS, the following symbols appear throughout this document to indicate dangerous conditions and important safety instructions.
DANGER: This indicates a hazardous situation, which if not avoided, will result in death or serious injury.

WARNING: This indicates a situation where failure to follow instructions may be a safety hazard or
cause equipment malfunction. Use extreme caution and follow instructions carefully.
NOTE: This indicates information that is very important for optimal system operation.
Follow instructions closely.

1.1 Safety Instructions
IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. This guide contains important instructions that you must follow during installation and maintenance of the PCS. Failing to follow any of these instructions may void the warranty. Follow all of the instructions in this manual. These instructions are key to the installation and maintenance of the APstorage PCS. These instructions are not meant to be a complete explanation of how to design and install APstorage PCSs. All installations must comply with national and local electrical codes and standards.

DANGER:

- Only qualified professionals should install and/or replace the APstorage PCS. - Perform all electrical installations in accordance with local codes. - To reduce risk of burns, do not touch the body of the PCS.

WARNING: - Do NOT attempt to repair the APstorage PCS. If it shows abnormal performance,
Contact APsystems Customer Support to obtain adequate support. Damaging or
opening the APstorage PCS will void the warranty.

NOTE:

- Before installing or using the APstorage PCS, please read all instructions and Cautionary markings in the technical documents and on the APstorage PCS.

2

APstorage Installation / User Manual

1. Important Safety Instructions
1.2 Radio Interference Statement
This equipment could radiate radio frequency energy which might cause interference to radio communications if you do not follow the instructions when installing and using the equipment. But there is no guarantee that interference will not occur in a particular installation. If this equipment causes interference to radio or television reception, the following measures might resolve the issues:
A) Relocate the receiving antenna and keep it well away from the equipment. B) Consult the dealer or an experienced radio / TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance may void the user's authority to operate the equipment.
1.3 Communication Disclaimer
The EMA system provides a friendly interface to monitor the working status of the whole energy storage system. At the same time, it can also help to locate problems during system maintenance. If communication has been lost for more than 24 hours, please contact the technical support of APsystems.
1.4 Symbols replace words on the equipment, on a display, or in manuals
Trademark.
Caution, risk of electric shock.

Caution, hot surface.

NOTICE, danger! This device directly connected with electricity generators and public grid.

Qualified personnel

Person adequately advised or supervised by an electrically skilled person to enable him or her to perceive risks and to avoid hazards which electricity can create. For the purpose of the safety information of this manual, a "qualified person" is someone who is familiar with requirements for safety, electrical system and EMC and is authorized to energize, ground, and tag equipment, systems, and circuits in accordance with established safety procedures. The inverter and storage system may only be commissioned and operated by qualified personnel.

3

APstorage Installation / User Manual

2. APstorage PCS Introduction
ELS series PCS is APtorage's Sea family product and the PCS is a battery Power Conversion System.
APsystems PCS, together with a compatible battery ( not offered by APsystems), becomes a complete and independent AC coupling storage solution for residential PV installations. It can be used with any new or already installed PV systems without changing equipment in place.

One PCS can be connected up to 20kWh compatible battery (see battery compatibility list). When multiple battery packs are connected, they need to be connected in parallel .(see connection diagram in the Battery User Manual)
APstorage will help home-owners to optimize their utility bill, offering full flexibility to manage their Electrical consumption. Several modes are available. (Backup power supply mode, Self-consumption mode and Advanced mode)
2.1 Dimensions

4

APstorage Installation / User Manual

2. APstorage PCS Introduction
2.2 Basic System Architecture
A typical APstorage system includes three main elements:
 APstorage PCS, which is a smart battery Power Conversion System.
The PCS includes an integrated ECU (Energy Communication Unit) to ensure monitoring of the overall system
once up and running.  a compatible Battery pack (see battery compatibility list)
 Auto-Transformer -T-A
Option 1 : PV system working off-grid

Off grid function only compatible with APsystems DS3 microinverters (fully compatible), as well as QS1 and YC600 microinverters (firmware update required).
Option 2 : PV system not working off-grid

Option 3 : mix of option 1 and 2 following the conditions above

NOTE: In a Storage System with APstorage PCS, the battery is one of the key components. Therefore, it
is necessary to keep the installation environment well ventilated, please refer to Battery user manual.

5

APstorage Installation / User Manual

2. APstorage PCS Introduction
2.3 Back-up Load Configuration

L1 or L2 Max continuous current carrying capacity  21A

Backup Port

Case1. If there is no 240V load, 120V load1 or load2 total Max power 2.5kVA.
Case2. If there is 240V load and power is P1, P1 5kVA, 120V load1 or load2 total Max power (5-P1)/2 kVA
NOTE: The 120V and 240V load configuration of auto-transformer should meet the below requirements.
It is stipulated that the 120V load received by L1N and L2N do not exceed 2.5kW respectively. If there is 240V load, 240V load power needs to be subtracted and distributed equally. For example, 240V load power is P1  then (5kw-P1) / 2 is the remaining 120V power of the assembleable L1N and L2N. The imbalance load cannot exceed the new power distribution.
L1N: voltage between L1 and Neutral line L2N: voltage between L2 and Neutral line

6

APstorage Installation / User Manual

2. APstorage PCS Introduction
2.4 LED
There are eight LED indicators on the PCS unit, indicating the working state of the PCS.

LED SYSTEM
GRID BACK UP ENERGY BATTERY
WI-FI
COM
FAULT

Condition Light on constantly Light flashing Light off Light on constantly Light flashing Light off Light on constantly Light off Light on constantly Light flashing 1 Light flashing 2 Light off Light on constantly Light flashing 1 Light flashing 2 Light off Light on constantly Light flashing 1 Light off Light on constantly
Light flashing 1
Light flashing 2
Light off Light on constantly Light flashing Light off

Description The system is operating The system is starting up The system shutdown The grid exists and is connected The grid exists but is not connected The grid does not exist The backup system is operating
The backup is off Buy energy from grid
Zero output Supplying energy to grid The grid is not connected or system is not operating The battery is charging The battery is discharging The battery SOC is low The battery is disconnected The WiFi is connected to the router The WiFi is not connected to the router The WiFi function is closed The battery and the internet communication are normal
The battery communication is normal, but the internet communication is abnormal
The battery communication is abnormal, but the internet communication is normal
The battery and the internet communication are abnormal Fault has occurred
Back up output overload No fault

NOTE: Light flashing 1: Every 5 seconds light on for 1 second.
Light flashing 2: Every 2 seconds light on for 1 second.

7

APstorage Installation / User Manual

2. APstorage PCS Introduction
2.5 PCS Connection Port

Cable inlet:
 DC cable: Connect the positive and negative terminals of the battery.  AC cable: AC grid port is connected to power grid and AC backup port is off grid output.  Transformer cable: Connect to the Auto-transformer.  Internet cable: Connect the Internet port into the router.  CT cable: Connect the PV CT or Grid CT cable to the PCS. (Both cable ports are available)
Zigbee:
Use for Zigbee communication.
Wifi:
Use for Wifi communication.
2.6 Transformer (T-A) Connection Port

(Bottom view of PCS)

PCS Port:
Connect to the PCS.

PCS Port

8

APstorage Installation / User Manual

3. Installation
3.1 Packing List
3.1.1 PCS Packing List
KITS

PICTURES

PCS
Wall-mounted Bracket Expansion screw (M8*70) Fixing screw (M6×14)
CTCurrent transformer

×1 ×1
×3 ×1 ×4 (grid CT and PV CT)

Installation / User Manual
×1
NOTE: The expansion screws are applicable only to cement concrete walls. For other types of walls,
install expansion screws based on the wall type.
NOTE: The customer will need to purchase a combiner box for parallel connection of the batteries.
Combiner box requirements: rated current of each connector100A.

9

APstorage Installation / User Manual

3. Installation
3.1.2 Transformer (T-A) Packing List Transformer (T-A) is delivered with below accessories.
KITS

PICTURES

Transformer (T-A) ×1
Wall-mounted Bracket ×1
Expansion screw (M8*70) ×4
Datasheet ×1
NOTE: The expansion screws are applicable only to cement concrete walls. For other types of walls,
install expansion screws based on the wall type.

10

APstorage Installation / User Manual

3. Installation
3.2 Select Mounting Location
1. PCS should be installed on a solid surface, where is suitable for PCS's dimensions and weight. 2. Do not install PCS in a confined space with no ventilation. 3. If the PCS is installed outside, it should be protected under shelter from direct sunlight or bad weather conditions
(like snow, rain, lightning, etc). Fully shielded installation locations are preferred.

4. Install the APstorage vertically on the wall. 5. Make sure that the PCS is mounted "face-up": Product logo is visible after installation. 6. Leave enough space around APstorage. The specific requirements are as follows:

300mm(11.8")

300mm

300mm

300mm

300mm

500mm(19.7")

500mm

WARNING: APstorage PCS cannot be installed near flammable, explosive or strong electro-magnetic
equipment.

11

APstorage Installation / User Manual

3. Installation
3.3 PCS Installation Steps
 Mark the holes position on the wall and drill holes according to wall type and expansion screws type. The configured expansion screw is drilled with a diameter of 12mm(0.5") and a depth of 50-55mm(1.9-2.2").
 Put the expansion screws into the holes on the wall. Use a wrench to tighten the hex nuts, so that the expansion screws sleeve are fully expanded. Then remove the hex nuts. Hang the wall mounting bracket into the expansion screws, and use the hex nuts to fix it firmly. Make sure that the wall mounting bracket is horizontal after installation.
 Lift the PCS to hang it into the wall mounting bracket, and fix the PCS on wall mounting bracket with the M6×14mm screw.

M6×14 screw

3.4 Transformer Installation Steps
 Mark the holes position on the wall and drill holes according to wall type and expansion screws type. Fix the wall mounting bracket horizontally on the wall. For drilling and installation of expansion screws, refer to PCS.
 Clip the Transformer to the 4 buckles of the wall mounting bracket.





12

APstorage Installation / User Manual

3. Installation
3.5 PCS Wiring
When wiring, you need to remove the lower cover first, just unscrew the 9 locking screws.

Battery Connector AC Connection to Grid

RJ45 Internet

AC Connection to Transformer

CT Connection

AC Connection to Backup

Communication Connection

13

APstorage Installation / User Manual

3. Installation
When wiring, you need to crimp appropriate terminals on the cable (as shown for dimensions). The cables and terminals need to be prepared by yourself or purchased from APsystems.
The terminals for DC cable The terminals for AC cable
ELS-5K Recommend minimum cableDC cable 3AWG / AC cable option 1 or 3 : 8AWG, option 2 : 11AWG (see chap 2.2)
The terminals for DC cable The terminals for AC cable
ELS-3K Recommend minimum cableDC cable 6AWG / AC cable option 1 or 3 : 10AWG, option 2 : 11AWG (see chap 2.2)
PCS has been installed with cable glands before delivery. If connection is required through pipe (prepare pipe yourself), remove cable glands on the BOX first.

3.5.1 DC Wiring
Connect the DC cable to the PCS through the cable gland. As shown, connect wire + & - to Battery connector. Torque value40lb.in
3.5.2 AC Wiring
3.5.2.1 Connect the grid AC cables to the PCS through the cable gland. As shown, connect wire L1 and wire L2 to grid breaker, connect wire N to the Terminal block, and connect wire PE to the earth terminal block. Torque value10.53lb.in

14

APstorage Installation / User Manual

3. Installation

Battery

L1 L2 N PE

Wire+: Red/Orange; Wire-: Black

GRID

L1-Black; L2-Red; N-White; PE-Green

3.5.2.2 Connect the backup AC cables to the PCS through the cable gland. As shown, connect wire L1 , wire L2 and N to

the terminal block , and connect wire PE to the earth terminal Block.

Torque value10.53lb.in

3.5.3 Transformer Wiring

3.5.3.1 Connect the backup AC cables to the PCS through the cable gland. As shown, connect wire L1 , wire L2 and N to

the terminal block , and connect wire PE to the earth terminal Block.

Torque value10.53lb.in

L1 L2 N PE BACKUP
L1-Black; L2-Red; N-White; PE-Green

L1 L2 N PE APstorage Transformer
L1-Black; L2-Red; N-White; PE-Green

NOTE: Make sure to connect the two live wire to L1 and L2, connect the neutral wire to N, otherwise the
precision of the CT will be affected.

When Transformer wiring, you need to crimp appropriate terminals on the cable (as shown for dimensions). The terminals need to be prepared by yourself or purchased from APsystems.

option 1 or 3 : mini 8AWG, option 2 : mini 11AWG (see chap 2.2)

Transformer T-A(5KVA)

Transformer T-A(10KVA)

15

APstorage Installation / User Manual

3. Installation
When wiring, you need to remove the cover first, just unscrew the 10 locking screws.
Connect the transformer cable.
T-A(5KVA)

T-A(10KVA)

L1-Black; N-White; L2-Red

Torque value18lb.in

L1-Black; N-White; L2-Red
16

Torque value18lb.in
APstorage Installation / User Manual

3. Installation
3.5.4 Communication Wiring
3.5.4.1 Internet Communication Using the Internet cable, connect the Internet port into the router. The PCS also can be connected to the router via Wi-Fi, please refer to the chapter 4.5.3.1.

Internet Communication
3.5.4.2 Battery Communication Connect the Battery's RJ45 port to PCS's RJ45 port.

Battery Communication

3. Installation

17

APstorage Installation / User Manual

3. Installation
3.5.5 CT Wiring
Connect the PV CT cable to the PV CT port of the PCS. Connect the GRID CT cable to the GRID CT port of the PCS.

GRID CT1 GRID CT2
PV CT1 PV CT2
The direction of CTs: The arrows on the GRID CT should point from grid to distribution box and the arrows on the PV
CT from distribution box to PV.

-

Arrow pointing PCS

GRID CT

Arrow pointing PV PV CT

Distribution box

Grid
18

PV

Distribution box

APstorage Installation / User Manual

3. Installation

NOTE: After having completed the wiring, the nuts of the cable gland must be tightened.
3.6 Install the Lower Cover
As shown, screw the 9 screws back.

3.7 PV System to APstorage Pairing
1. Identify the largest maximum single load power rating (kW) that you want to backup, and select the absolute minimum number of PCS units required to meet the 2017 NEC 690.10->710.15(A) requirements. A maximum of 2 ELS 5K units can be connected in parallel.
2. Based on the estimated backup loads for the user defined time period, calculate the required energy storage (kWh) capacity and the minimum number of battery required.
3. Refer the Table 1 to calculate the maximum PV system power (PV system 1) to connect to the backup side, if the total PV system power is larger than Max PV system power, connect the excess power (PV system 2) to the grid side.

Table 1: Maximum PV system power for storage system for backup operation

ELS-5K units 1 1 2 2 2

Battery units 1 >=2 2 3 >=4

Max PV system power (kWac) 3.12 6.25 6.25 9.37 12.5

ELS-3K units 1 1 2 2

Battery units 1
>=2 2 3

Max PV system power (kWac) 3.12 4.6 6.25 9.2

19

APstorage Installation / User Manual

3. Installation
3.8 Wiring Diagram

PV system option 2 (see chap 2.2)
ELS-5K  Backup Sub Breaker: 32A AC Breaker  Main Breaker : 63A AC Breaker  Battery Breaker: 125A DC Breaker  PV Breaker: 32A AC Breaker ELS-3K  Backup Sub Breaker: 25A AC Breaker  Main Breaker : 50A AC Breaker  Battery Breaker: 100A DC Breaker  PV Breaker: 25A AC Breaker
20

PV system option 1 (see chap 2.2)
APstorage Installation / User Manual

3. Installation
3.9 Parallel Wiring Diagram
Please refer to chapter 4.5.6 to set the PCS to work in parallel.

21

APstorage Installation / User Manual

3. Installation
3.10 PCS Parallel Wiring Steps
Step 1. Connect the battery DC cable and the battery communication cable (do not connect the communication cable between PCS and PCS).

Step 2. Use the APP to set one as the master and one as the slave. (Please refer to chapter 4.5.6 to set the PCS to work in parallel)
Step 3. Reconnect the communication cable between PCS and PCS.

Master

Slave

Step 4. Use the APP to connect to the host, enter the PCS management interface, and automatically search for 2 PCS IDs, which are the master and the slave.
Step 5. Connect all the wires according to the above parallel diagram and use them.

NOTE: Please refer the manual of battery to set the batteries work in parallel.

22

APstorage Installation / User Manual

3. Installation
3.11 Start-up sequence
3.11.1 Power ON
Once the unit has been properly installed and the batteries are connected well, turn on the batteries, then turn on the Battery Breaker, Grid Breaker, Backup Breaker and Main breaker to power the system.
3.11.2 Check the system
Please refer to chapter 4.5.1 to check the system.
3.11.3 Power Off
Turn off the Battery Breaker, Grid Breaker, Backup Breaker and Main breaker to power the system,then turn off the batteries.
WARNING: Installation must be performed with care.
Before making the final DC connection or closing DC breaker/disconnect, be sure positive(+) must be connect to positive(+) and negative(-) must be connected to negative(-). Reverse polarity connection on battery will damage the inverter.

23

APstorage Installation / User Manual

4. APstorage User Interface
Professional and certified Installer can commission, monitor and maintain the APstorage solution and performance via the EMA Manager APP. Please search for the APP in APP Store or Google Play, or use mobile browser to scan the QR codes to download the APP. (EMA App is for end-users, EMA Manager is for installers). You can also click on the link below to download the APP: http://q-r.to/1OrC
4.1 Configure APstorage with EMA Manager
The APstorage PCS has been designed with local connection and management functionality. You can access this local functionality through EMA Manager. Click "Local access" to enter this function.

Enter Local access
You will be noticed if your smartphone or tablet is not initially connected to the hotspot of the APstorage PCS or the router to which the APstorage PCS is connected.
- Step1: Open Wi-Fi setting in your smartphone, connect to the hotspot of the APstorage PCS, the format of the hotspot is ECU-WIFI_XXXX, XXXX being the last four digits of the built-in ECU. Also you can connect to the router which the APstorage PCS is connected to.

24

APstorage Installation / User Manual

4. APstorage User Interface

the hotspot of the APstorage PCS

The hotspot of the router

- Step 2: Open EMA Manager. - Step 3: Click "Local access" You can use this APP to connect the APstorage PCS to the router via Lan or Wlan. (Please refer to chapter 4.5.3)

25

APstorage Installation / User Manual

4. APstorage User Interface
4.2 Home Page
4.2.1 Once connected to the integrated ECU hot-spot, you can enter the homepage. If there is also an APsystems PV system with an ECU (ECU-R or ECU-C) you can switch ECUs in the LAN by clicking the drop-down box. It can be switched only when the mobile phone and ECU are connected to the same router.

26

APstorage Installation / User Manual

4. APstorage User Interface
4.2.2 You can view the system ID, charge and discharge status, real-time power, SOC, today's charged energy, total charged energy since installed, and CO reduction.

27

APstorage Installation / User Manual

4. APstorage User Interface
4.3 Module
This page displays the real-time power of the photovoltaic inverter. Click on the Module, the detailed information of the microinverter will be displayed, including the microinverter ID, PV module power, grid voltage, frequency and temperature. You need to install APsystems microinverters with the PV modules to view these data.

28

APstorage Installation / User Manual

4. APstorage User Interface
4.4 Data
4.4.1 Data overview This page is used to display the system overview. Select a date to view the system's power summary information and power distribution information and its graph. Click on the "Energy" or "Power" buttons to view the energy and power chart of the system for the day. Select Daily, Monthly or Yearly to display the current month, current year, and historical data.

29

APstorage Installation / User Manual

4. APstorage User Interface
4.4.2 Storage data The daily energy storage power curve is displayed on this page. Select a date to view the historical power and electricity curve of energy storage. Select Daily, Monthly or Yearly to display the current month, current year, and historical data curve.

30

APstorage Installation / User Manual

4. APstorage User Interface
4.4.3 ECU data The daily photovoltaic power curve is displayed on this page. Select the date to view the PV system data. Select Daily, Monthly or Yearly to display the current month, current year, and historical power curve. You need to install PV system with APsystems microinverters to view these data.

31

APstorage Installation / User Manual

4. APstorage User Interface
4.5 Workbench
The workbench displays the latest communication time, and currently supported function catalog. Click the corresponding button to enter the function page.

32

APstorage Installation / User Manual

4. APstorage User Interface
4.5.1 Automatic System Check Enter the Automatic System Check interface, you can check the APstorage information. If there is an alarm, you can click to view the detailed information.

33

APstorage Installation / User Manual

4. APstorage User Interface
4.5.2 System Mode The system mode of the APstorage PCS includes backup power supply mode, residual power Self-Consumption mode and advanced mode. If you need to set the system working mode, please select the corresponding working mode and set the parameters, and then click "OK".
Backup power supply mode:
Emergency power supply (EPS) mode, the system charge when grid connected and discharge when off grid.
Self-Consumption mode:
APstorage charges when solar power is produced more than home requires, and the power is used for household appliances when your home requires more power than your solar system can provide.
Advanced mode:
Discharge during peak time, charge during off-peak time.

Click for details

34

APstorage Installation / User Manual

4. APstorage User Interface
4.5.2.1 Time-Based Control Click "Time-Based Control", you can view the list of peak times and off-peak times currently set. You can edit the time ranges by clicking on it. Click on the "Add" button to select the peak time or off-peak time to be added.
Click to add
Click to edit

35

APstorage Installation / User Manual

4. APstorage User Interface
4.5.3 Network Setting Click the button to enter the WLAN Settings or LAN Settings page.

36

APstorage Installation / User Manual

4. APstorage User Interface
4.5.3.1 WLAN Settings This interface will display the WLAN connection status of the ECU. Scroll down the screen and the available SSID will be displayed. Click SSID, and enter the password. After entering the password, the ECU will restart. Please reconnect the ECU.

37

APstorage Installation / User Manual

4. APstorage User Interface
4.5.3.2 LAN Settings The LAN setting of ECU is divided into automatically obtaining IP address and using fixed IP address. Obtaining an IP address automatically (recommended) means that the router will automatically assign the IP to the ECU. When using a fixed IP, please enter the IP address, subnet mask, default gateway, preferred DNS server and alternate DNS server.

38

APstorage Installation / User Manual

4. APstorage User Interface
4.5.4 Hotspot Settings Enter the hotspot setting interface, you can change the hotspot password of the ECU. After setting the password, please reconnect to the hotspot of the ECU.

39

APstorage Installation / User Manual

4. APstorage User Interface
4.5.5 Data Settings After entering this page, the time will be displayed on the right. Click on the date, time, and time zone to modify.

40

APstorage Installation / User Manual

4. APstorage User Interface
4.5.6 PCS This page displays a list of PCSs in the system. If the PCS supports the master-slave setting, you can click on "Parallel" to enter the Parallel page.
NOTE: Unconfigured PCS, must be set as "Master" or "Slave" to use parallel function.

41

APstorage Installation / User Manual

4. APstorage User Interface
4.5.6.1 PCS Parallel Select "master" or "slave" and click "save" to complete the setting. After setting, you can see whether PCS is master or slave.
NOTE: After the setting is completed, the system will restart, please reconnect the system.

42

APstorage Installation / User Manual

4. APstorage User Interface
4.5.7 Zero Export When the APstorage PCS is associated to an APsystems PV system, if needed, the Zero Export function can limit the PV output power to the grid, and the user can set the maximum allowable reverse current power when the Zero Export function is turned on.
NOTE: The minimum reverse current power power is set to 0.1KW.

43

APstorage Installation / User Manual

4. APstorage User Interface
4.5.8 Device Information The device information page displays the device ID, device type, PCS number, battery capacity, device version number, wired and wireless network MAC, currently connected router SSID, IP address.

44

APstorage Installation / User Manual

4. APstorage User Interface
4.5.9 Pair APstorage with the PV system Enter this page, you can view the current association status. If you have installed APsystems microinverters with an ECU, you can pair the APstorage with the PV system. Enter the PV ECU's ID, then click Save, the APstorage will associate with PV system automatically. It is necessary if you want to turn on zero export function.

45

APstorage Installation / User Manual

4. APstorage User Interface
4.5.10 Battery saver Enter this page, you can enable the "battery saver" function. After enabling the "battery saver" function, if APstorage doesn't charge or discharge for an hour, it will go to sleep.

46

APstorage Installation / User Manual

4. APstorage User Interface
4.5.11 Wakeup Settings When system enters into sleeping mode, you can wake it up by clicking on "Wake Up Immediately".

47

APstorage Installation / User Manual

4. APstorage User Interface
4.5.11.1 Timed Wake Up On this page, you can set the wake-up time period and interval.

48

APstorage Installation / User Manual

4. APstorage User Interface
4.6 Settings
Select "Language" to set the APP language, and "About" to view the APP introduction.

49

APstorage Installation / User Manual

5. Technical Data
Model Region General Specification
Dimensions W/H/D Weight Maximum Efficiency Temperature Range Ingress Protection Relative Humidity Ventilation Communication Ports Parallel Function Grid Regulation
Grid Regulation Safety and EMC Compliance
Battery Input/Output Data
DC Battery Input Voltage Battery Capacity Charging Strategy for Li-Ion Battery Max Continuous Charge Current Max Continuous Discharge Current
AC Output Data (On-grid)
Max. Continuous Output Power Max. Continuous Output Current Max. Continuous Current From Utility Grid Max. Output Fault Current (AC) and Duration Nominal Output Voltage Nominal Output Voltage Range Nominal Output Frequency/Range Output Power Factor THD Grid Connection
AC Output Data (Backup)
Max. Output Apparent Power@240V Peak Output Apparent Power@240V Max. Output Current Nominal Output Voltage L1-L2/L-N Nominal Output Frequency
(1) Voltage/frequency range can be adjusted if required by local utility

ELS-5K-NA NA

847×502×197mm 37kg 96.5%
-25°C-65°C (-13°F-149°F) Type 4X 10%-90%
Natural convection Ethernet/ Wireless/RS485/CAN
Yes UL 1741 UL1741; CSA C22.2 No. 107.1-16; CA Rule21(UL1741SA); ANSI/CAN/UL-9540(For energy storage system) FCC part15; ICES-003

40.0-60.0VDC

50~800Ah

Self-adaption to BMS

100A

77A

100A

77A

5000VA

3680A

20.8A

15.3A

40.6A

30.6A

60.66Apk, 10.5ms; 9.32Arms @3cycles; 7.23Arms @5cycles

240V

211-264V(1)

60Hz/59.3-60.5Hz(1)

>0.99(Adjustable from 0.8 leading to 0.8 lagging)

3%

Single-phase

5000VA

3680VA

7500VA(10s)

5520VA(10s)

20.8A

15.3A

240Vac/120Vac (with external transformer)

60Hz

© All Rights Reserved Specifications subject to change without notice please ensure you are using the most recent update found at web : usa.APsystems.com

50

APstorage Installation / User Manual

6. Contact Information .

APsystems America 8701 N. Mopac Expy, Ste 160, Austin, TX 78759 Mail: info.usa@APsystems.com Web: usa.APsystems.com
51

APstorage Installation / User Manual



References

WPS 文字