User Manual for zenitel models including: TMIS-1 Turbine Mini IP Intercom, TMIS-1, Turbine Mini IP Intercom, Mini IP Intercom, IP Intercom

Download

TMIS-1 | Zenitel

TMIS-x Turbine Mini IP Intercom


File Info : application/pdf, 2 Pages, 594.93KB

PDF preview unavailable. Download the PDF instead.

A100K11589 TMIS-X Turbine Mini Mounting Manual
TMIS-x Turbine Mini IP Intercom
Mounting Manual

1 Turbine Mini Intercom
This document describes the mounting procedures and connections of the TMIS-X Turbine Mini intercoms.

Item Number 1008116010 1008116040 1008140020 1008140030

Type TMIS-1 TMIS-4 TA-2 TA-3

Item Name Turbine Mini IP Intercom Turbine Mini IP Intercom, 2 Buttons Turbine Flush Mount 2-Gang Double-Depth Back Box Turbine Flush Mount 2-Gang Back Box

39 mm

33.5 mm

117 mm

48 mm 1.89?

TMIS-1

TMIS-4

2 Flush Mount 2-Gang Back Boxes - TA-2 & TA-3

1.81? 46 mm

0.98? 25 mm

117 mm

1.81? 46 mm

0.98? 25 mm

48 mm 1.89?

96 mm / 3.78?

96 mm / 3.78?

64 mm / 2.52?

96 mm / 3.78?

96 mm / 3.78?

89 mm / 3.50?

SIDE
TA-2

SIDE
TA-3

L It is recommended to utilize back boxes with weep holes at the bottom.

3 Flush Mounting Procedure
Turbine Mini

Flush Mount 2-Gang Back Box

#6-32 UNC Screws

#6-32 UNC Screws
1. Mount the 2-gang back box into the wall 2. Fasten the Turbine Mini intercom to the back box with four #6-32 UNC countersunk-head screws

4 Connections
The TMIS-X Turbine Mini IP intercom has a RJ-45 PoE/LAN port, and 6-pin & 10-pin external connectors.

1 24 VDC for external secondary power 2 if PoE is not used. Pin 1 is positive. 3 - COM relay 4 - NO relay 5 - NC relay
1 - 5.3V (LED driver) 2 - GND 3 - Input/Output 1 4 - Input/Output 2 5 - Input/Output 3 6 - Input/Output 4 7 - Input/Output 5 8 - Input/Output 6 9 - 600 ohm balanced line out + 10 - 600 ohm balanced line out -

RJ-45 PoE port

Ethernet / Power
Secondary Power Relays
Input/Output

10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
24 VDC (16 ­ 48 V) secondary power is provided from an external adapter.
There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W.
6 I/Os are available. Each I/O can be configured as either input, output, or LED driver.

Audio Line Out A balanced 600 ohm audio line out

L Use cables crimped with ferrules for terminal block connectors

Ethernet Connection

· When the Turbine Mini intercom is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned.
· To make the intercom speak its IP address, press the call button on the station.

DOC NO. A100K11589

Date: 19 Oct 2021

www.zenitel.com

cs@zenitel.com

Zenitel and its subsidiaries assume no responsibility for any errors that may appear in this publication, or for damages arising from the information therein. Zenitel and Vingtor-Stentofon products are developed and marketed by Zenitel. The company's Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001. Zenitel reserves the right to modify designs and alter specifications without notice. ZENITEL PROPRIETARY. This document and its supplementing elements contain Zenitel or third-party information which is proprietary and confidential. Any disclosure, copying, distribution or use is prohibited, if not otherwise explicitly agreed in writing with Zenitel. Any authorized reproduction, in part or in whole, must include this legend: Zenitel ­ All rights reserved.



References