User Guide for Multi-Tech models including: TA2410 Talk Anytime Click to Talk, TA2410, Talk Anytime Click to Talk, Click to Talk, Talk

MULTI-TECH SYSTEMS TALKANYTIME CLICK-TO-TALK TA3010 (01) PDF MANUAL - Manual-Hub.com

PDF preview unavailable. Download the PDF instead.

MULTI-TECH SYSTEMS TALKANYTIME CLICK-TO-TALK TA3010 (01)
TalkAnytime R
Click-to-Talk Media Server
Cabling Guide
Digital Models: TA2410 & TA3010
https://manual-hub.com/

TalkAnytime® Cabling Guide
Cabling Guide
® TalkAnytime Click-to-Talk Media Servers Digital Models (T1 and E1): TA2410 and TA3010 82100220L Rev. A
Copyright This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved.
Copyright © 2006 Multi-Tech Systems, Inc.
Multi-Tech Systems, Inc. makes no representations or warranty with respect to the contents hereof and specifically disclaims any implied warranty of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes. Check Multi-Tech's web site for current versions of our product documentation.

Revision A

Date 11/29/06

Description Initial release.

Trademarks Multi-Tech, TalkAnytime, and the Multi-Tech logo are registered trademarks of Multi-Tech Systems, Inc. MultiVOIP is a trademark of Multi-Tech Systems, Inc. All other brand and product names mentioned in this publication are trademarks or registered trademarks of their respective companies.

Patents This Product is covered by one or more of the following U.S. Patent Numbers: 6151333, 5757801, 5682386, 5.301.274; 5.309.562; 5.355.365; 5.355.653; 5.452.289; 5.453.986. Other Patents Pending.

GENERAL CONTACT
Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, Minnesota 55112, USA (763) 785-3500 (800) 328-9717 Fax: 763-785-9874 www.multitech.com

Country France
India
Europe, Asia, Africa U.S., Canada, All Others

TECHNICAL SUPPORT

By E-mail

By Phone

support@ multitech.fr

(+33) 1-64 61 09 81

support@ multitechindia. com

(+91) 1242340780

support@ multitech.co.uk

(+44) 118 959 7774

support@ multitech.com

(800) 9722439; (763) 717-5863

2

Multi-Tech Systems, Inc.

https://manual-hub.com/

TalkAnytime® Cabling Guide
Introduction
This guide shows you how to make the cable connections to set up your ®
digital TalkAnytime unit. See the TalkAnytime User Guide included on the TalkAnytime CD for more information. The "Quick Start Instructions" chapter shows how to get the TalkAnytime unit up and running with a basic configuration.
Safety Warnings
Lithium Battery Caution
A lithium battery on the voice/fax channel board provides backup power for the timekeeping capability. The battery has an estimated life expectancy of ten years.
When the battery starts to weaken, the date and time may be incorrect. If the battery fails, the board must be sent back to Multi-Tech Systems for battery replacement.
Warning: There is danger of explosion if the battery is incorrectly replaced.
Ethernet Ports Caution
Caution: The Ethernet ports and command ports are not designed to be connected to a Public Telecommunication network.
Safety Warnings Telecom · Use this product only with UL- and CUL-listed computers (US). · Never install phone wiring during a lightning storm. · Never install a phone jack in a wet location unless the jack is specifically
designed for wet locations.
· Never touch uninsulated phone wires or terminals unless the phone line has
been disconnected at the network interface.
· Use caution when installing or modifying phone lines. · Avoid using a phone during an electrical storm; there is a risk of electrical
shock from lightning.
· Do not use a phone in the vicinity of a gas leak. · To reduce the risk of fire, use only 26 AWG or larger telephone line cord. · This product must be disconnected from power source and telephone
network interface when servicing.
Safety Recommendations for Rack Instructions · Ensure proper installation of the TalkAnytime unit in a closed or multi-unit
enclosure by following the recommended installation as defined by the enclosure manufacturer. Do not place the TalkAnytime unit directly on top of other equipment or place other equipment directly on top of the TalkAnytime unit.

Multi-Tech Systems, Inc.

3

https://manual-hub.com/

TalkAnytime® Cabling Guide
Safety Recommendations for Rack Instructions (cont'd)
· If installing the TalkAnytime unit in a closed or multi-unit enclosure, ensure
adequate airflow within the rack so that the maximum recommended ambient temperature is not exceeded.
· Ensure that the TalkAnytime unit is properly connected to earth ground via a
grounded power cord. If a power strip is used, ensure that the power strip provides adequate grounding of the attached apparatus.
· Ensure that the mains supply circuit is capable of handling the load of the
TalkAnytime unit. See the power label on the equipment for load requirements.
· Maximum ambient temperature for the TalkAnytime unit is 60 degrees
Celsius (140° F) at 20-90%s non-condensing relative humidity.
· This equipment should only be installed by properly qualified service personnel. · Only connect like circuits. In other words, connect SELV (Secondary Extra
Low Voltage) circuits to SELV circuits and TN (Telecommunications Network) circuits to TN circuits.
· To reduce the risk of shock, all access doors should be closed during
normal operation of the equipment.

4

Multi-Tech Systems, Inc.

https://manual-hub.com/

TalkAnytime® Cabling Guide

TA-2410/3010 Package Contents

·

® One TalkAnytime TA2410 or TA3010 unit

· One power cord

· One command cable (RJ45-to-DB9 connectors)

· Two rack-mount brackets and four mounting screws

· One printed Cabling Guide

· One TalkAnytime CD containing software and user documentation.

TalkAnytime R
Cabling Guide

TalkAnytime R

Multi-Tech Systems, Inc.

5

https://manual-hub.com/

TalkAnytime® Cabling Guide
Quick Hookup for TA2410 & TA3010

6

Multi-Tech Systems, Inc.

https://manual-hub.com/

TalkAnytime® Cabling Guide
Earth Ground Connection & Power-Up

TalkAnytime Unit

Product Ground Screw

Ground Wire:
Size 18AWG or thicker

Grounding connectors must be secured permanently to
product ground screw and earth ground screw.

Earth Ground Screw: Connected to
Permanent Earth Ground of Building's
Electrical System
GND

Ground Connection. Ensure that the unit is securely and permanently connected to an earth ground (GND) with a ground wire of 18 gauge (18 AWG) or thicker. The ground wire needs to be installed between the grounding screw on the TalkAnytime chassis and a permanent earth ground. Whether the unit is used in a rack or on a desktop, you must verify that the earth ground connection is permanent and reliable. In order for the ground connection to be considered permanent, the grounding wire must connect to the earth ground of the building's electrical wiring system and the ground connection must use a screw terminal or other reliable means of fastening. The ground connection must not be as easily disconnected as, for example, a power cord.
Power-Up. The TalkAnytime unit's fan is on whenever the power cord is connected to a power source. Turn on power to the TalkAnytime circuitry by placing the ON/OFF switch on the back panel to the ON position. Wait for the Boot LED to go off before proceeding. This may take a few minutes.

TalkAnytime Configuration
When the cabling connections above have been made, go to the "Quick Start Instructions" chapter of the User Guide (on your TalkAnytime CD) for detailed instructions about configuration.

Multi-Tech Systems, Inc.

7

https://manual-hub.com/

82100220L
https://manual-hub.com/