Lamborghini CaloreClima Burners Range
Gas & Light Oil Burners
Reliability and Control in Every Stage of the Combustion Process.
The Lamborghini CaloreClima range of gas and oil burners is designed to deliver efficiency, reliability, and low emissions for all thermal applications. Selected gas models feature Low NOx technology, which further reduces environmental impact and ensures exceptionally clean combustion while meeting the strictest standards. Available in single-stage, two-stage, and progressive versions, with power ratings from 14.5 kW up to 2372 kW, these burners meet the requirements of residential, commercial, and industrial installations. With NOx classes ranging from level 2 to level 5, Lamborghini CaloreClima burners offer the perfect combination of cutting-edge technology, sustainability, and high performance.
Gas Burners
JOB Series (One Stage)
Features: One stage gas burner from 17 kW up to 350 kW. All models are certified in class 5 (≤56 mg/kWh) according to the ErP Directive. Can be operated with natural gas or LPG using a dedicated kit. Available with two different combustion head lengths and one or more gas trains for optimized combination. Two combustion head lengths and a high-pressure fan ensure a wide working range. Supplied with: Fixing flange and screws, Insulation flange gasket, 7-pin connector (up to mod. 25), Instructions manual.
Compliance: 2014/35/UE Low Voltage Directive, 2014/30/UE EMC Directive, (EU) 2016/426 Gas Appliance Regulation, 2006/42/EC Machine Directive, 2011/65/UE RoHS2 Directive + 2015/863/UE, EN 676:2020, EN 50156-1:2024, EN IEC 55014-1:2021, EN IEC 55014-2:2021, EN 60335-1:2024-04, EN 60335-2-102:2016, EN IEC 61000-6-2:2019, EN IEC 61000-6-3:2019.
Burner Model | Head | NOx Class* | Operation | Burner Output (kW) Min | Burner Output (kW) Max | Power Supply (Phase/V/Hz) | Motor (W) |
---|---|---|---|---|---|---|---|
JOB 4 - E | TC | 5 | One stage | 17 | 46 | 1/230/50-60 | 75 |
JOB 4 L - E | TL | 5 | One stage | 17 | 46 | 1/230/50-60 | 75 |
JOB 7 - E | TC | 5 | One stage | 30 | 70 | 1/230/50-60 | 75 |
JOB 7 L - E | TL | 5 | One stage | 30 | 70 | 1/230/50-60 | 75 |
JOB 10 - E | TC | 5 | One stage | 45 | 110 | 1/230/50-60 | 75 |
JOB 10 L - E | TL | 5 | One stage | 45 | 110 | 1/230/50-60 | 75 |
JOB 12 - E | TC | 5 | One stage | 60 | 120 | 1/230/50-60 | 75 |
JOB 12 L - E | TL | 5 | One stage | 60 | 120 | 1/230/50-60 | 75 |
JOB 17 - E | TC | 5 | One stage | 85 | 170 | 1/230/50 | 200 |
JOB 17 L - E | TL | 5 | One stage | 85 | 170 | 1/230/50 | 200 |
JOB 25 - E | TC | 5 | One stage | 85 | 240 | 1/230/50 | 200 |
JOB 25 L - E | TL | 5 | One stage | 85 | 240 | 1/230/50 | 200 |
JOB 35 - E | TC | 5 | One stage | 200 | 350 | 1/230/50 | 300 |
JOB 35 L - E | TL | 5 | One stage | 200 | 350 | 1/230/50 | 300 |
* Class 5 - NOx ≤ 56 mg/kWh (in compliance with EN 676 European standard). TC - Short head / TL - Long head.
Working Diagrams: Graphs illustrating the relationship between burner output (kW) and back pressure in the combustion chamber (mbar) for different JOB series models.
JOB/2 Series (Two Stage)
Features: Two stage gas burner from 30 kW up to 700 kW. Models are certified in class 5 (≤ 56 mg/kWh) or class 3 (< 80 mg/kWh for mod. 70/2) according to ErP Directive. Can be operated with natural gas or LPG. Available with two combustion head lengths and one or more gas trains. Air gate control via hydraulic jack. Two combustion head lengths and high-pressure fan ensure wide working range. Supplied with: Fixing flange and screws, Insulation flange gasket, 7-pin connector (up to mod. 25/2 E), Instructions manual.
Compliance: Similar to JOB series.
Burner Model | Head | NOx Class* | Operation | Burner Output (kW) Min | Burner Output (kW) Max | Power Supply (Phase/V/Hz) | Motor (W) |
---|---|---|---|---|---|---|---|
JOB 10/2 - E | TC | 5 | Two stage | 22 | 110 | 1/230/50-60 | 75 |
JOB 10/2 L - E | TL | 5 | Two stage | 22 | 110 | 1/230/50-60 | 75 |
JOB 17/2 - E | TC | 5 | Two stage | 60 | 170 | 1/230/50 | 200 |
JOB 17/2 L - E | TL | 5 | Two stage | 60 | 170 | 1/230/50 | 200 |
JOB 25/2 - E | TC | 5 | Two stage | 60 | 240 | 1/230/50 | 200 |
JOB 25/2 L - E | TL | 5 | Two stage | 60 | 240 | 1/230/50 | 200 |
JOB 40/2 - E | TC | 5 | Two stage | 100 | 400 | 3/230-400/50 | 370 |
JOB 40/2 L - E | TL | 5 | Two stage | 100 | 400 | 3/230-400/50 | 370 |
JOB 50/2 - E | TC | 5 | Two stage | 120 | 500 | 3/230-400/50 | 550 |
JOB 50/2 L - E | TL | 5 | Two stage | 120 | 500 | 3/230-400/50 | 550 |
JOB 70/2 | TC | 3 | Two stage | 200 | 700 | 3/230-400/50 | 1100 |
JOB 70/2 L | TL | 3 | Two stage | 200 | 700 | 3/230-400/50 | 1100 |
* Class 5 - NOx ≤ 56 mg/kWh (in compliance with EN 676 European standard). Class 3 - NOx ≤ 80 mg/kWh (in compliance with EN 676 European standard). TC - Short head / TL - Long head.
Working Diagrams: Graphs illustrating the relationship between burner output (kW) and back pressure in the combustion chamber (mbar) for different JOB/2 series models.
JOB/PR Series (Progressive)
Features: Progressive gas burner from 120 kW up to 2200 kW. Air/gas ratio controlled by a mechanical cam during transition. Can be modulated using the RWF series electronic controller (accessory). Models are certified in class 3 (< 80 mg/kWh) or class 5 (≤ 56 mg/kWh for mod. 50) according to ErP Directive. Can be operated with natural gas or LPG. Available with two combustion head lengths and gas trains. Supplied with: Fixing flange and screws, Insulation flange gasket, Instructions manual.
Compliance: Similar to JOB series.
Burner Model | Head | NOx Class* | Operation | Burner Output (kW) Min | Burner Output (kW) Max | Power Supply (Phase/V/Hz) | Motor (W) |
---|---|---|---|---|---|---|---|
JOB 50/PR - E | TC | 5 | Progressive | 120 | 500 | 3/230-400/50 | 550 |
JOB 50/PR L - E | TL | 5 | Progressive | 120 | 500 | 3/230-400/50 | 550 |
JOB 70/PR | TC | 3 | Progressive | 200 | 700 | 3/230-400/50 | 1100 |
JOB 70/PR L | TL | 3 | Progressive | 200 | 700 | 3/230-400/50 | 1100 |
JOB 100/PR | TC | 3 | Progressive | 280 | 875 | 3/230-400/50 | 1100 |
JOB 100/PR L | TL | 3 | Progressive | 280 | 875 | 3/230-400/50 | 1100 |
JOB 120/PR | TC | 3 | Progressive | 290 | 1100 | 3/230-400/50 | 2200 |
JOB 120/PR L | TL | 3 | Progressive | 290 | 1100 | 3/230-400/50 | 2200 |
JOB 150/PR | TC | 3 | Progressive | 350 | 1600 | 3/230-400/50 | 2200 |
JOB 150/PR L | TL | 3 | Progressive | 350 | 1600 | 3/230-400/50 | 2200 |
JOB 200/PR | TC | 3 | Progressive | 320 | 2200 | 3/230-400/50 | 3000 |
JOB 200/PR L | TL | 3 | Progressive | 320 | 2200 | 3/230-400/50 | 3000 |
* Class 5 - NOx ≤ 56 mg/kWh. Class 3 - NOx ≤ 80 mg/kWh. TC - Short head / TL - Long head.
Working Diagrams: Graphs illustrating the relationship between burner output (kW) and back pressure in the combustion chamber (mbar) for different JOB/PR series models.
Gas Burner Accessories
KIT MODUL RWF 50
Power modulation regulator to transform JOB series burners from Progressive to Modulating operation.
Code | Description | Burners |
---|---|---|
094590X0 | Kit modul RWF 50 | JOB 50/PR - E; JOB 50/PR L - E |
094613X0 | Kit modul RWF 50 | JOB 70/PR - E; JOB 70/PR L - E; JOB 100/PR - E; JOB 100/PR L - E; JOB 120/PR - E; JOB 120/PR L - E; JOB 150/PR - E; JOB 150/PR L - E; JOB 200/PR - E; JOB 200/PR L - E |
094592X0 | Temperature probe - Range: 0 - 130° C | Kit Modul RWF 50 and JOB series progressive type |
094593X0 | Pressure probe - Range: 0 - 4 bar | Kit Modul RWF 50 and JOB series progressive type |
094594X0 | Pressure probe - Range: 0 - 10 bar | Kit Modul RWF 50 and JOB series progressive type |
094595X0 | Pressure probe - Range: 0 - 16 bar | Kit Modul RWF 50 and JOB series progressive type |
KIT VPS504 NG / LPG
Natural gas / LPG valve proving system.
Code | Description | Burners |
---|---|---|
094601X0 | KIT VPS504 NG | JOB Series |
094602X0 | KIT VPS504 LPG | JOB Series |
094603X0 | VPS adapter | kit VPS504 and JOB 10/2 - E; JOB 17/2 - E; JOB 25/2 - E |
Antivibration Joint
Code | Description | Burners |
---|---|---|
094596X0 | Antivibration joint - Size 1 1/4" | JOB Series |
094597X0 | Antivibration joint - Size 1 1/2" | JOB Series |
094598X0 | Antivibration joint - Size 2" | JOB Series |
094599X0 | Antivibration joint - Size DN65 | JOB Series |
094600X0 | Antivibration joint - Size DN80 | JOB Series |
Gas Filter
Code | Description | Burners |
---|---|---|
094581X0 | Gas filter - Size 2" | JOB Series |
094582X0 | Gas filter - Size DN80 | JOB Series |
094583X0 | Gas filter - Size DN65 | JOB Series |
Boiler and Gas Burner Matching
Table showing compatibility between Boiler models (MEGAPREX, PREX H) and Gas Burner models, including output and back pressure.
Boiler Model | Code | Output - kW | Back pressure - mbar | Gas burner Model | Code | Operating |
---|---|---|---|---|---|---|
MEGAPREX N 92 N | 0QIJ3AXD | 99.5 | 0.5 | JOB 10 L - E | 0UEMBBXD | One stage |
JOB 10/2 L - E | 0UEBBBXD | Two stage | ||||
MEGAPREX N 107 N | 0QIJ4AXD | 116 | 0.7 | JOB 12 L - E | 0UEMCBXD | One stage |
JOB 17/2 L - E | 0UEBEBXD | Two stage | ||||
MEGAPREX N 152 N | 0QIJ6AXD | 165 | 1.2 | JOB 25 L - E | 0UEMFBXD | One stage |
JOB 25/2 L - E | 0UEBFBXD | Two stage | ||||
MEGAPREX N 190 N | 0QIJ7AXD | 206 | 1.2 | JOB 25 L - E | 0UEMFBXD | One stage |
JOB 25/2 L - E | 0UEBFBXD | Two stage | ||||
MEGAPREX N 240 N | 0QIJ8AXD | 261 | 2.3 | JOB 35 L - E | 0UEMGBXD | One stage |
JOB 40/2 L - E | 0UEBHBXD | Two stage | ||||
MEGAPREX N 300 N | 0QIJ9AXD | 326 | 3.3 | JOB 40/2 L - E | 0UEBHBXD | Two stage |
JOB 50/PR L - E | 0UEPIBXD | Progressive | ||||
MEGAPREX N 350 N | 0QIJAAXD | 378 | 3.5 | JOB 50/2 L - E | 0UEBIBXD | Two stage |
JOB 50/PR L - E | 0UEPIBXD | Progressive | ||||
JOB 50/2 L - E | 0UEBIBXD | Two stage | ||||
MEGAPREX N 401N (WN) | 0QIJBAXD | 434 | 4.4 | JOB 50/PR L - E | 0UEPIBXD | Progressive |
MEGAPREX N 525N (WN) | 0QIJEAXD | 567 | 4.3 | JOB 70/2 L | 0UEBKBXD | Two stage |
JOB 70/PR L | 0UEPKBXD | Progressive | ||||
MEGAPREX N 600N (WN) | 0QIJFAXD | 648 | 4.8 | JOB 100/PR L | 0UEPLBXD | Progressive |
MEGAPREX N 720N (WN) | 0QIJHBXD | 777 | 4.5 | JOB 100/PR L | 0UEPLBXD | Progressive |
MEGAPREX N 820N (WN) | 0QIJIBXD | 881 | 5.6 | JOB 120/PR L | 0UEPNBXD | Progressive |
MEGAPREX N 940N (WN) | 0QIJJBXD | 1011 | 5.4 | JOB 150/PR L | 0UEPPBXD | Progressive |
MEGAPREX N 1060N (WN) | 0QIJKBXD | 1075 | 6 | JOB 150/PR L | 0UEPPBXD | Progressive |
PREX H 3 COND 65 | 0RGZ3AXD | 61.3 | 0.4 | JOB 7 L - E | 0UEM9BXD | One stage |
JOB 10/2 L - E | 0UEBBBXD | Two stage | ||||
PREX H 3 COND 100 | 0RGZ4AXD | 94.3 | 0.65 | JOB 10 L - E | 0UEMBBXD | One stage |
JOB 10/2 L - E | 0UEBBBXD | Two stage | ||||
PREX H 3 COND 150 | 0RGZ5AXD | 141.5 | 1.7 | JOB 17 - E | 0UEMEAXD | One stage |
JOB 17/2 - E | 0UEBEAXD | Two stage | ||||
PREX H 3 COND 230 | 0RGZ8AXD | 217 | 1.7 | JOB 25 - E | 0UEMFAXD | One stage |
JOB 25/2 - E | 0UEBFAXD | Two stage | ||||
PREX H 3 COND 370 | 0RGZBAXD | 349.1 | 2 | JOB 40/2 - E | 0UEBHAXD | Two stage |
JOB 50/PR - E | 0UEPIAXD | Progressive | ||||
PREX H 3 COND 500 | 0RGZDAXD | 471.7 | 3.5 | JOB 70/2 | 0UEBKAXD | Two stage |
JOB 70/PR | 0UEPKAXD | Progressive | ||||
JOB 70/2 | 0UEBKAXD | Two stage | ||||
PREX H 3 COND 650 | 0RGZGAXD | 613.2 | 4.2 | JOB 70/PR | 0UEPKAXD | Progressive |
PREX H 3 COND 820 | 0RGE01XD | 767 | 6 | JOB 100/PR L | 0UEPLBXD | Progressive |
PREX H 3 COND 1000 | 0RGF02XD | 935 | 6.4 | JOB 120/PR | 0UEPNAXD | Progressive |
Overall Dimensions
Detailed dimension tables and diagrams for JOB, JOB/2, and JOB/PR series burners and their gas trains.
Gas Train Descriptions: Explanation of Multibloc Dungs and VGD Siemens gas trains, listing components like safety gas valve, working gas valve, gas pressure switch, gas regulator, gas filter, tightness control (VPS), and connection pipe.
Light Oil Burners
NOVA PRO (One Stage Low NOx)
Features: Output range from 14.5 kW up to 64 kW. NOx class 4 (<120 mg/kWh) compliant with EN 267. R models include a pre-heater for cold starts. Designed for easy adjustment and maintenance. Supplied with: Fixing flange and screws, Insulation flange gasket, 7-pin connector, Oil nozzle, 2 flexible pipes, Oil filter, Instructions manual.
Compliance: 2006/42/EC Machinery Directive, 2014/30/UE EMC Directive, 2014/35/UE Low Voltage Directive, 813/2013/UE Ecodesign Erp Regulation, EN267 European standard, 2006/42/EC Efficiency, 2011/65/EU RoHS2 Directive.
Burner Model | Head | NOx Class* | Operation | Flow Rate (Kg/h) Min | Flow Rate (Kg/h) Max | Output Power (kW) Min | Output Power (kW) Max | Electrical Supply (Phase/V/Hz) | Motor Absorption (W) | Total Absorption (W) | Nozzle Supplied |
---|---|---|---|---|---|---|---|---|---|---|---|
NOVA 4 PRO | TC | 4 (ERP) | One stage | 1.22 | 3.79 | 14.5 | 45 | 1/230/50 | 75 | 350 | Danfoss 0.75 60°S |
NOVA 4 R PRO (1) | TC | 4 (ERP) | One stage | 1.22 | 3.79 | 14.5 | 45 | 1/230/50 | 75 | 360 | Danfoss 0.75 60°S |
NOVA 8 PRO | TC | 4 (ERP) | One stage | 2.11 | 5.4 | 25 | 64 | 1/230/50 | 90 | 400 | Danfoss 1.00 60°S |
NOVA 8 R PRO (1) | TC | 4 (ERP) | One stage | 2.11 | 5.4 | 25 | 64 | 1/230/50 | 90 | 410 | Danfoss 1.00 60°S |
(1) R version with preheater. (2) NOx class 4 <120 mg/kW/h in according with EN 267. (3) TC - Short flame tube.
Working Diagrams: Graphs illustrating the relationship between burner output (kW) and back pressure in the combustion chamber (mbar) for NOVA PRO models.
NOVA/2 PRO (Two Stage Low NOx)
Features: Two stage low NOx burner, output range 32 kW to 450 kW. NOx class 4 (<120 mg/kWh) compliant with EN 267. Available with two combustion head lengths. Hydraulic jack for air gate control. Designed for easy adjustment and maintenance. Supplied with: Fixing flange and screws, Insulation flange gasket, 7-pin connector, 4-pin connector, Oil nozzle, 2 flexible pipes, Oil filter, Instructions manual.
Compliance: Similar to NOVA PRO series.
Burner Model | Head | NOx Class* | Operation | Flow Rate (Kg/h) Min | Flow Rate (Kg/h) Max | Output Power (kW) Min | Output Power (kW) Max | Electrical Supply (Phase/V/Hz) | Motor Absorption (W) | Total Absorption (W) | Nozzle Supplied |
---|---|---|---|---|---|---|---|---|---|---|---|
NOVA 12/2 PRO | TC | 4 (ERP) | Two stage | 2.7 | 9.7 | 32 | 115 | 1/230/50 | 130 | 450 | Danfoss 1.50 60°S |
NOVA 12/2 L PRO | TL | 4 (ERP) | Two stage | 2.7 | 9.7 | 32 | 115 | 1/230/50 | 130 | 450 | Danfoss 1.50 60°S |
NOVA 15/2 PRO | TC | 4 (ERP) | Two stage | 5.54 | 14.33 | 65.7 | 172.1 | 1/230/50 | 160 | 500 | Danfoss 2.50 60°S |
NOVA 15/2 L PRO | TL | 4 (ERP) | Two stage | 5.54 | 14.33 | 65.7 | 172.1 | 1/230/50 | 160 | 500 | Danfoss 2.50 60°S |
NOVA 25/2 PRO | TC | 4 (ERP) | Two stage | 8.43 | 22.01 | 100 | 261 | 1/230/50 | 200 | 600 | Danfoss 5.00 60°S |
NOVA 25/2 L PRO | TL | 4 (ERP) | Two stage | 8.43 | 22.01 | 100 | 261 | 1/230/50 | 200 | 600 | Danfoss 5.00 60°S |
NOVA 35/2 PRO | TC | 4 (ERP) | Two stage | 11.79 | 32.43 | 140 | 385 | 1/230/50 | 550 | 700 | Danfoss 5.50 60°B |
NOVA 35/2 L PRO | TL | 4 (ERP) | Two stage | 11.79 | 32.43 | 140 | 385 | 1/230/50 | 550 | 700 | Danfoss 5.50 60°B |
NOVA 50/2 PRO | TC | 4 (ERP) | Two stage | 15.18 | 37.94 | 180 | 450 | 1/230/50 | 550 | 800 | Danfoss 6.00 60°B |
NOVA 50/2 L PRO | TL | 4 (ERP) | Two stage | 15.18 | 37.94 | 180 | 450 | 1/230/50 | 550 | 800 | Danfoss 6.00 60°B |
Working Diagrams: Graphs illustrating the relationship between burner output (kW) and back pressure in the combustion chamber (mbar) for NOVA/2 PRO models.
NOVA (One Stage Burner)
Features: One stage burner, output range 15.4 kW up to 350 kW. NOx Class 2 (<185 mg/kWh) compliant with EN 267. R models include a pre-heater. Designed for easy adjustment and maintenance. Models from 12 onwards available with two combustion head lengths for compatibility. Supplied with: Fixing flange and screws, Insulation flange gasket, 7-pin connector, Oil nozzle, 2 flexible pipes, Oil filter, Instructions manual.
Compliance: 2006/42/EC Machinery Directive, 2014/30/UE EMC Directive, 2014/35/UE Low Voltage Directive, EN267 European standard, 2006/42/EC Efficiency, 2011/65/EU RoHS2 Directive.
Burner Model | Head | NOx Class* | Operation | Flow Rate (Kg/h) Min | Flow Rate (Kg/h) Max | Output Power (kW) Min | Output Power (kW) Max | Electrical Supply (Phase/V/Hz) | Motor Absorption (W) | Total Absorption (W) | Nozzle Supplied |
---|---|---|---|---|---|---|---|---|---|---|---|
NOVA 1 | TC | 2 | One stage | 1.3 | 3.5 | 15.4 | 41 | 1/230/50 | 75 | 300 | Danfoss 0.65 80°S |
NOVA 1 R (1) | TC | 2 | One stage | 1.21 | 3.5 | 14.4 | 41 | 1/230/50 | 75 | 310 | Danfoss 0.65 80°S |
NOVA 4 | TC | 2 | One stage | 1.7 | 5 | 20 | 59 | 1/230/50 | 75 | 300 | Danfoss 0.75 60°S |
NOVA 4 R (1) | TC | 2 | One stage | 1.7 | 5 | 20 | 59 | 1/230/50 | 75 | 310 | Danfoss 0.75 60°S |
NOVA 8 | TC | 2 | One stage | 4 | 8.9 | 47 | 105 | 1/230/50 | 90 | 350 | Danfoss 1.50 60°S |
NOVA 8 L | TL | 2 | One stage | 4 | 8.9 | 47 | 105 | 1/230/50 | 90 | 350 | Danfoss 1.50 60°S |
NOVA 8 R (1) | TC | 2 | One stage | 4 | 7.9 | 47 | 105 | 1/230/50 | 90 | 360 | Danfoss 1.50 60°S |
NOVA 8 R L (1) | TL | 2 | One stage | 4 | 8.9 | 47 | 105 | 1/230/50 | 90 | 360 | Danfoss 1.50 60°S |
NOVA 12 | TC | 2 | One stage | 5.1 | 11 | 60 | 130 | 1/230/50 | 90 | 350 | Danfoss 2.50 60°S |
NOVA 12 L | TL | 2 | One stage | 5.1 | 11 | 60 | 130 | 1/230/50 | 90 | 350 | Danfoss 2.50 60°S |
NOVA 15 | TC | 2 | One stage | 6.2 | 16 | 73 | 190 | 1/230/50 | 130 | 400 | Danfoss 3.00 60°S |
NOVA 15 L | TL | 2 | One stage | 6.2 | 16 | 73 | 190 | 1/230/50 | 130 | 400 | Danfoss 3.00 60°S |
NOVA 20 | TC | 2 | One stage | 7.3 | 21.1 | 86.4 | 250 | 1/230/50 | 150 | 400 | Danfoss 3.50 60°S |
NOVA 20 L | TL | 2 | One stage | 7.3 | 21 | 86.4 | 250 | 1/230/50 | 150 | 400 | Danfoss 3.50 60°S |
NOVA 25 | TC | 2 | One stage | 12.63 | 25.27 | 150 | 300 | 1/230/50 | 200 | 450 | Danfoss 5.00 60°S |
NOVA 25 L | TL | 2 | One stage | 12.63 | 25.27 | 150 | 300 | 1/230/50 | 200 | 450 | Danfoss 5.00 60°S |
NOVA 30 | TC | 2 | One stage | 12.63 | 29.48 | 150 | 350 | 1/230/50 | 200 | 500 | Danfoss 6.00 60°S |
NOVA 30 L | TL | 2 | One stage | 12.63 | 29.48 | 150 | 350 | 1/230/50 | 200 | 500 | Danfoss 6.00 60°S |
(1) R version with preheater - (2) NOx class 2 <185 mg/kW/h in according with EN 267 - (3) TC/TL - Short flame tube / Long flame tube.
Working Diagrams: Graphs illustrating the relationship between burner output (kW) and back pressure in the combustion chamber (mbar) for NOVA series models.
NOVA/2 (Two Stage)
Features: Two stage burner, output range 60 kW up to 546 kW. NOx Class 2 (<185 mg/kWh) compliant with EN 267. Designed for easy adjustment and maintenance. Available with two combustion head lengths for compatibility. Supplied with: Fixing flange and screws, Insulation flange gasket, 7-pin connector, 4-pin connector, Oil nozzle, 2 flexible pipes, Oil filter, Instructions manual.
Compliance: 2006/42/EC Machinery Directive, 2014/30/UE EMC Directive, 2014/35/UE Low Voltage Directive, EN267 European standard, 2006/42/EC Efficiency, 2011/65/EU RoHS2 Directive.
Burner Model | Head | NOx Class* | Operation | Flow Rate (Kg/h) Min | Flow Rate (Kg/h) Max | Output Power (kW) Min | Output Power (kW) Max | Electrical Supply (Phase/V/Hz) | Motor Absorption (W) | Total Absorption (W) | Nozzle Supplied |
---|---|---|---|---|---|---|---|---|---|---|---|
NOVA 12/2 | TC | 2 | Two stage | 5.05 | 10.96 | 60 | 130 | 1/230/50 | 90 | 350 | Danfoss 1.50 60°S |
NOVA 12/2 L | TL | 2 | Two stage | 5.05 | 10.96 | 60 | 130 | 1/230/50 | 90 | 350 | Danfoss 1.50 60°S |
NOVA 15/2 | TC | 2 | Two stage | 6.2 | 16 | 73 | 190 | 1/230/50 | 130 | 400 | Danfoss 3.00 60°S |
NOVA 15/2 L | TL | 2 | Two stage | 6.2 | 16 | 73 | 190 | 1/230/50 | 130 | 400 | Danfoss 3.00 60°S |
NOVA 20/2 | TC | 2 | Two stage | 7.3 | 21.06 | 86.4 | 250 | 1/230/50 | 150 | 400 | Danfoss 3.50 60°S |
NOVA 20/2 L | TL | 2 | Two stage | 7.3 | 21.06 | 86.4 | 250 | 1/230/50 | 150 | 400 | Danfoss 3.50 60°S |
NOVA 25/2 | TC | 2 | Two stage | 12.63 | 25.27 | 150 | 300 | 1/230/50 | 200 | 450 | Danfoss 5.00 60°S |
NOVA 25/2 L | TL | 2 | Two stage | 12.63 | 25.27 | 150 | 300 | 1/230/50 | 200 | 450 | Danfoss 5.00 60°S |
NOVA 30/2 | TC | 2 | Two stage | 12.63 | 29.48 | 150 | 350 | 1/230/50 | 200 | 500 | Danfoss 6.00 60°S |
NOVA 30/2 L | TL | 2 | Two stage | 12.63 | 29.48 | 150 | 350 | 1/230/50 | 200 | 500 | Danfoss 6.00 60°S |
NOVA 45/2 | TC | 2 | Two stage | 17 | 46 | 202 | 546 | 1/230/50 | 550 | 800 | Danfoss 4.50 60°S |
NOVA 45/2 L | TL | 2 | Two stage | 17 | 46 | 202 | 546 | 1/230/50 | 550 | 800 | Danfoss 5.50 60°S |
Working Diagrams: Graphs illustrating the relationship between burner output (kW) and back pressure in the combustion chamber (mbar) for NOVA/2 series models.
NOVA/2 TEC (Two Stage Oil Burner)
Features: Two stage oil burner, output range 237 kW up to 2372 kW. NOx Class 2 (<185 mg/kWh) compliant with EN 267. Designed for easy adjustment and maintenance. Available with two combustion head lengths. Supplied with: Fixing flange and screws, Insulation flange gasket, Oil nozzle, 2 flexible pipes, Oil filter, Instructions manual.
Compliance: 2006/42/EC Machinery Directive, 2014/30/UE EMC Directive, 2014/35/UE Low Voltage Directive, EN267 European standard.
Burner Model | Head | NOx Class* | Operation | Flow Rate (Kg/h) Min | Flow Rate (Kg/h) Max | Output Power (kW) Min | Output Power (kW) Max | Electrical Supply (Phase/V/Hz) | Motor Absorption (W) | Nozzle Supplied |
---|---|---|---|---|---|---|---|---|---|---|
NOVA 60/2 TEC | TC | 2 | Two stage | 20 | 60 | 237 | 710 | 3/230-400/50 | 1.1 | 7 GPH 60°-5 GPH 60° PLP |
NOVA 60/2 L TEC | TL | 2 | Two stage | 20 | 60 | 237 | 710 | 3/230-400/50 | 1.1 | 7 GPH 60°-5 GPH 60° PLP |
NOVA 80/2 TEC | TC | 2 | Two stage | 26 | 80 | 308 | 949 | 3/230-400/50 | 1.1 | 7 GPH 60°-8 GPH 60° PLP |
NOVA 80/2 L TEC | TL | 2 | Two stage | 26 | 80 | 308 | 949 | 3/230-400/50 | 1.1 | 7 GPH 60°-8 GPH 60° PLP |
NOVA 120/2 TEC | TC | 2 | Two stage | 40 | 120 | 474 | 1423 | 3/230-400/50 | 2.2 | 8.50 GPH 60°-12 GPH 60° PLP |
NOVA 120/2 L TEC | TL | 2 | Two stage | 40 | 120 | 474 | 1423 | 3/230-400/50 | 2.2 | 8.50 GPH 60°-12 GPH 60° PLP |
NOVA 150/2 TEC | TC | 2 | Two stage | 50 | 150 | 592 | 1780 | 3/230-400/50 | 3 | 17.50 GPH 60°-12 GPH 60° PLP |
NOVA 150/2 L TEC | TL | 2 | Two stage | 50 | 150 | 592 | 1780 | 3/230-400/50 | 3 | 17.50 GPH 60°-12 GPH 60° PLP |
NOVA 200/2 TEC | TC | 2 | Two stage | 60 | 200 | 710 | 2372 | 3/230-400/50 | 4 | 21.50 GPH 60°-15.5 GPH 60° PLP |
NOVA 200/2 L TEC | TL | 2 | Two stage | 60 | 200 | 710 | 2372 | 3/230-400/50 | 4 | 21.50 GPH 60°-15.5 GPH 60° PLP |
Working Diagrams: Graphs illustrating the relationship between burner output (kW) and back pressure in the combustion chamber (mbar) for NOVA/2 TEC models.
NOVA/PR TEC (Progressive or Modulating Oil Burner)
Features: Progressive or modulating oil burner, output range 178 kW up to 2372 kW. NOx Class 2 (<185 mg/kWh) compliant with EN 267. Air ratio regulated by a mechanical cam. Can be modulated using RWF series electronic controller (accessory). Designed for easy adjustment and maintenance. Supplied with: Fixing flange and screws, Insulation flange gasket, 2 flexible pipes, Oil nozzles, Oil filter, Instructions manual.
Compliance: 2006/42/EC Machinery Directive, 2014/30/UE EMC Directive, 2014/35/UE Low Voltage Directive, EN267 European standard.
Burner Model | Head | NOx Class* | Operation | Flow Rate (Kg/h) Min | Flow Rate (Kg/h) Max | Output Power (kW) Min | Output Power (kW) Max | Electrical Supply (Phase/V/Hz) | Motor Absorption (W) | Nozzle Supplied |
---|---|---|---|---|---|---|---|---|---|---|
NOVA 45/PR L TEC | TL | 2 | Progressive | 15 | 45 | 178 | 532 | 3/230-400/50 | 0.55 | Monarch 6.50 GPH 60° BPS |
NOVA 60/PR L TEC | TL | 2 | Progressive | 20 | 60 | 237 | 710 | 3/230-400/50 | 1.1 | Monarch 10.5 GPH 60° BPS |
NOVA 80/PR L TEC | TL | 2 | Progressive | 26 | 80 | 308 | 949 | 3/230-400/50 | 1.1 | Monarch 12.00 GPH 60° BPS |
NOVA 120/PR L TEC | TL | 2 | Progressive | 40 | 120 | 474 | 1423 | 3/230-400/50 | 2.2 | Monarch 17.50 GPH 60° BPS |
NOVA 150/PR L TEC | TL | 2 | Progressive | 50 | 150 | 592 | 1780 | 3/230-400/50 | 3 | Fluidics W2 KG-H 130-50 |
NOVA 200/PR L TEC | TL | 2 | Progressive | 60 | 200 | 710 | 2372 | 3/230-400/50 | 4 | Fluidics W2 KG-H 160-50 |
Working Diagrams: Graphs illustrating the relationship between burner output (kW) and back pressure in the combustion chamber (mbar) for NOVA/PR TEC models.
Disclaimer
The illustrations and data provided are indicative. Lamborghini CaloreClima reserves the right to make any changes deemed to be most appropriate for the improvement of the product or of the service offered without being obliged to give prior notice. The images in this catalogue are under copyright owned by Lamborghini CaloreClima.
Website: www.lamborghinicalor.com
Email: info@lamborghinicalor.com