Instruction Manual for USCutter models including: GS-207M Heat Press, GS-207M, Heat Press, Press

Russell

Operation Manual

Manual

Refurbished Lopo Galaxy 4X Water Bottle Press GS-207M


File Info : application/pdf, 19 Pages, 1.92MB

PDF preview unavailable. Download the PDF instead.

Lopo-GS-207M-Manual
Operation Manual
(GS-207M)
Safety Instructions
When using your heat press, basic precautions should always be followed,
including the following:
1. Read all instructions. 2. Use heat press only for its intended use. 3. To reduce the risk of electric shock, do not immerse the heat press in water or other liquids. 4. Never pull cord to disconnect from outlet, instead grasp plug and pull to disconnect. 5. Do not allow cord to touch hot surfaces, allow heat press to cool completely before storing. 6. Do not operate heat press with a damaged cord or if the equipment has been dropped or
damaged.To reduce the risk of electric shock, do not disassemble or attempt to repair the heat press. Take it to a qualified service person for examination and repair. Incorrect assembly or repair could increase the risk of fire, electric shock, or injury to persons when the equipment is used. 7. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 8. Close supervision is necessary for any heat press being used by or near children. Do not leave equipment unattended while connected. 9. Burns can occur when touching hot metal parts. 10. To reduce the likelihood of circuit overload, do not operate other high voltage equipment on the same circuit. 11. If an extension cord is necessary, then a 20 amperage rated cord should be used. Cords rated for less amperage may overheat. Care should be taken to arrange the cord so that it cannot be pulled or tripped over.
1

Table Of Contents
Safety Instructions.............................11 Technical Parameters........................ 3 Machine View................................... 4 Control Panel Guide........................... 5 Operating Instructions........................ 5 - 1 1
 Connecting the System.........................................................5  Turning the System On..........................................................6  Adjusting the Temperature......................................................6-7  Adjusting the Time................................................................7  Printing and Pressing............................................................8-9  How to Change Heater.........................................................9  Sub Menu Setting.................................................................10-11
Exploded Views And Parts List..............12-10 Electrical Schematic............................20
2

Technical Parameters

Model:

GS-207M

Heater Size: Power(120volt) Power(240volt) Temperature Range

W195mm*H170mm for 400ml/500ml/600ml aluminum sports water bottle. 4*300W/4*120W 16.1 Amps(max) 4*300W/4*120W 8.1Amps(max) Max.220/430

Time Range Machine Size

0~999S 65.2×33.9×28.5cm

Packing Size Packing Weight

73×43×40cm 24kg

Maximum

Paper

Printing Size:

Suggest Temp&Time Setting: Certificate

400ml sports bottle: 175*99mm(L*W) 500ml sports bottle: 175*114mm(L*W) 600ml sports bottle: 175*134mm(L*W) 150C/190C 40-50secs 302F/374F 40-50secs CE,FCC

Warranty:

One year for whole machine except heaters

3

Machine View
4

Control Panel Guide
Operation Instructions 1.Connecting the System
 CONNECT THE POWER CORD Connect the power cord into a properly grounded electrical outlet with a sufficient amperage rating.
 VOLTAGE 120 Volt ­ GS-207M requires a full 20 amp grounded circuit for 120 volt operation. 240 Volt ­ GS-207M requires a full 10 amp grounded circuit for 240 volt operation.
 EXTENSION CORDS If used, should be as short as possible and not less than 12 gauge.Heavy duty cords are recommended.
 CIRCUITS that have less than 15 amps or that have other high demand equipment or appliances(especially more than one heat seal machine) plugged in, should not be used.
5

NOTE: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a similarly qualified person in order to avoid hazard.
2.Turn On the System
 Switch on the system. (fig.2.1)
2.1
3.Adjusting the Temperature
3.1 Press the Mode Select button located in the center of the Control Panel (fig.3.1).Press (+) and (-) button to select different heater. (fig.3.2).
3.1
3.2 For heater 1/2 and 3/4, press "set" button to choose "start temp" or "finish temp", press (+) and (-)button to set temperature. For heater 5 and 6,press "set" button to choose "start temp", press (+) and (-)button to set temperature.The temperature can be set from 0° C (0° F) to 220° C (428° F). (fig.3.2) 3.2
3.3 press set button again to finish setting,move the cursor to "next", ready to enter time setting page. (fig.3.3)
3.3
6

Remark: 1. heater 1/2 represent no.1 and no.2 heater, can only be set temperature at once time
together, because left air cylinder close the heater 1/2 together. Heater 1/2 can set "start temp" and "finish temp". 2. heater 3/4 represent no.3 and no.4 heater, can only be set temperature at once time together, because right air cylinder close the heater 3/4 together. Heater 3/4 can set "start temp" and "finish temp". 3. Heater 5 does not work for GS-207M. 4. Heater 6 does not work for GS-207M
4.Adjusting Time
4.1 In the time setting page, Press (+) and (-) button to select different heater..(fig.4.1)
4.1 4.2 Press "set" button to activate time
value setting. Press (-) button to lower the value ,or press the (+) button to raise the time value .The time setting range can be set from 0~999. Move the cursor to "back",press "set' button to get back to the main interface. (fig.4.2)
4.2
7

5.Printing And Pressing

5.1 Once heater reaches start

5.2 Adjust suitable pressure by turning

temperature,put bottles inside of mug heater pressure knob.

5.1
5.3 Then close handle to start transfer printing process.

5.2
5.3 Once printing process is over, buzzer will alarm and open the handle then take out bottles out of machine.

5.3

5.4

Remark: 1. Station 1/2 must work with two mugs inside together, working only with 1 mug inside
will damage the machine. 2. Station 3/4 must work with two mugs inside together, working only with 1 mug inside
will damage the machine. 3. Each heater's temperature is separately controlled by different triac, can be calibrated
separately. But we do not suggest customer make calibration unless there is a need.
8

6.How to Change Heater
Plug off the 4 phase plug
Take off the heater. Then do the opposite operation can change a new heater onto the machine
7.Sub Menu Introduction
In the time setting page, there is sub menu button, move the cursor to the button, press "set" button to enter into sub menu 7.1 Language setting.we offer 4
language for customer needs. English/Spanish/Russia/Portuguese. (fig.7.1). Once finish setting,go to next page.
7.1
9

7.2 Temperature calibration setting. Customer can make calibration on each heater once the heater's temperature is not correct.(fig.7.2).Once finish setting,go to next page.
7.2 7.3 Fahrenheit and Celsius setting.
(fig.7.3).Once finish setting,go to next page.
7.3 7.4 Auto-sleep setting. Customer can
set auto-sleep time. Once time is reached,machine will auto close without any operation (fig.7.4).Once finish setting,go to next page.
7.4
10

7.5 Brightness setting.Customer can reduce or increase brightness of the screen. (fig.7.5).Once finish setting,go to next page.
7.5 7.6 Counter Collection.Here customer
can see how many mugs have been printer by each heater. This setting can not be changed.. (fig.7.6).Once finish setting,go back to the main interface.
7.6
11

Exploded Views
GS-207M contains 4 main parts 1. Machine base assemble 2. Control box assemble 3. Heating elements assemble 4. Pressure system assemble
12

1. Machine Base Assemble:

Parts list
No. P/N

1

J.03.05.0600

2

J.03.06.0104

3

J.03.04.0011

4

J.03.04.0077

5

J.03.06.0077

6

J.03.04.0079

J.02.04.0138 7
J.02.04.0139

8

J.03.04.0078

9

J.03.06.0117

10

J.03.03.0037

Name

Qty

Machine Base

1

Round head bolt M3x6

2

Switch Power Supply DC12V 1

socket

1

Countersunk screw M3x8 2

On/off switch

1

Circuit breaker 18A

1

Circuit breaker 10A

1

Terminal Block

1

Ball headed bolt M4*10 2

Rubber foot

4

13

2. Control Box Assemble

Parts List

No. P/N

Name

Qty

1 J.03.05.0602 Top Cover

1

4 phase aviation plug(Male)

2 J.02.04.0164

4

with wires welded

3 J.03.06.0165 Ball headed bolt M5-12

6

4 J.03.04.0166 Circuit board GSK-07

1

5 J.03.06.0117 Ball headed bolt M4*10

4

6 J.03.01.0025 Sticker

1

7 J.03.05.0403 Circuit board cover

1

8 J.03.06.0104 Round head bolt M3x6

4

14

3.Heating Element Assemble
15

3.1.Heater Cover Assemble

Parts List

No. P/N

Name

Qty

1 J.03.06.0102 Round head bolt M6x16

4

2 J.03.04.0184 Buzzer

4

3 J.03.05.0601 Heater cover

1

4 J.03.06.0032 Handle Screw

8

5 J.03.05.0456 Supporting pillar

2

6 J.03.05.0417 Heater fix board

4

7 J.03.05.0421 Bottom base

4

8 J.03.05.0414 Door type cover-1

4

9 J.03.05.0415 Door type cofer-2

4

16

3.2. Heater Shaft Assemble

Parts List

No. P/N

Name

Qty

1 J.03.06.0117 Ball headed bolt M4*10 6

2 J.03.05.0426 Arc supporting plate

2

3 J.03.05.0419 Supporting board-1

1

4 J.03.05.0420 Supporting board-2

1

5 J.03.05.0418 connector-2

1

6 J.03.06.0103 Ball headed bolt M5*10 2 7 J.03.06.0142 Shoulder screw M5-6*12 1

8 J.03.05.0455 Connecting sheet

1

17

4.Pressure System Assemble

Parts List

No. P/N

Name

Qty

1 J.03.06.0005 Clamp

1

2 J.02.04.0148 Magnet switch

1

3 J.03.03.0003 Ball Shape Handle

1

4 J.03.06.0212 Screw M10-70

1

5 J.03.06.0127 Nut M10

1

6 J.03.05.0595 Connecting sheet

1

7 J.03.06.0140 Ball headed bolt M5*8

1

8 J.03.05.0596 Connecting set

1

9 J.03.06.0144 Cup head screw M10-20

1

10 J.03.05.0615 Connecting sheet

1

18

Electrical Schematic
19



References

Microsoft Word 2019