DZS 2466GN Quick Installation Guide
Model: 2466GN
Version: V 1.0
1. Caution and Warnings
Please follow the instructions below to avoid physical injury:
- Do not install the unit during a storm.
- Do not connect or disconnect any line to avoid the risk of electric shock.
- This unit is for indoor use only, and all communication wirings are limited to inside the building.
- Do not plug in, turn on, or attempt to operate an obviously damaged unit.
- Never look directly at the fiber TX port and fiber cable ends when they are powered on.
- Do not use near water.
- Do not place near high-temperature sources.
- Do not disassemble the unit.
- Do not operate the unit in a location where the maximum ambient temperature exceeds 40°C (104°F).
- Open optical connections must use a protective cap under all circumstances to protect against physical damage and dirt.
- Before making connections, use isopropyl alcohol and non-fibrous cellulose wipes to clean the faces of the connectors.
- Avoid impact stresses when handling connectors. Physical damage to the faces of optical connections impairs transmission quality (higher attenuation).
- Avoid a bend radius in excess of 30 mm for fiber optic links.
- Check the available voltage supply.
- Only use the unit in dry rooms.
- Set up the unit away from direct sunlight or other electrical equipment.
- Only connect approved accessories.
- It may only be repaired by authorized service personnel.
- This equipment is not suitable for use in locations where children are likely to be present.
Limited Warranty
Defects and damage resulting from product disassembly by yourself are not covered under this warranty. Such behavior may also amount to intellectual property infringement.
2. Introduction
2.1 Package Contents
- 2466GN Optical Network Terminal (ONT)
- QIG (Quick Installation Guide)
2.2 Specification
Item | Specification |
---|---|
Uplink Interface | 1 GPON port (SC/APC) |
Service Interface | 4 10/100/1000Base-T ports (RJ45) |
VoIP Interface | 2 FXS ports (RJ11) |
Power Adapter | Output: DC12V/2A |
Operating Temp. | 0 to 40°C (32 to 104°F) |
Operating Humidity | 5 to 95% (non-condensing) |
Dimensions | 9.91 in (251.80 mm) x 5.83 in (148.1 mm) x 1.5 in (38.4 mm) |
2.3 Interface
The DZS 2466GN features the following interfaces:
- GPON Port: Connects to the optical network.
- GE 1-4 Ports: Four 10/100/1000Base-T Ethernet ports for connecting PCs or LAN devices.
- POTS 1-2 Ports: Two FXS ports (RJ11) for connecting VoIP phones.
- USB Port: For connecting an external 3.0 USB drive.
- WPS Button: Enables the Wi-Fi Protected Setup process.
- RESET Button: Reboots the unit.
- UPS Port: Power connector and UPS backup power input.
2.4 LED Status
The unit has various status LEDs:
Label | Light | Status | Definition |
---|---|---|---|
POWER | Green | ON | Normal operation on AC source. |
POWER | Yellow | ON | Operating on Battery Power. |
POWER | Yellow | Slow Blink (2/sec) | Battery Alarm (Low Battery, Missing or Replace). |
STATUS | Green | ON | Normal Operation. |
STATUS | Green | Rapid Blink (10/sec) | Unit has been reset to factory defaults / is unconfigured. |
STATUS | Green | Slow Blink (1/sec) | Boot-up/ Initialization/ provisioning in progress. |
ALARM | Red | ON | Major Alarm (including operating in battery power). |
ALARM | Red | Slow Blink (2/sec) | SW or Config update in progress. |
WAN | Green | ON | Ranged successfully. |
WAN | Green | Flash (1/sec) | Ranging in progress. |
WAN | Green | OFF | Not ready for ranging or not provisioned. |
INTERNET | Green | ON | Internet service is available. |
INTERNET | Green | OFF | Internet service is unavailable (no response from DNS server). |
GE1-4 | Green | ON | Ethernet interface linked. |
GE1-4 | Green | Flash | Data transmitting. |
GE1-4 | Green | OFF | Ethernet interface not linked. |
VOICE | Green | ON | Registered successfully. |
VOICE | Green | Slow Blink (1/sec) | Off hook. |
VOICE | Green | OFF | Registration failed or telephone service is not provisioned. |
USB | Green | ON | USB is connected. |
USB | Green | OFF | USB is not connected. |
2.4GHz | Green | ON | 2.4GHz WiFi service is enabled on ONT. |
2.4GHz | Green | Slow Blink (1/sec) | 2.4GHz WiFi data passing between ONT and connected devices. |
2.4GHz | Green | OFF | 2.4GHz WiFi service is disabled on ONT. |
5GHz | Green | ON | 5GHz WiFi service is enabled on ONT. |
5GHz | Green | Slow Blink (1/sec) | 5GHz WiFi data passing between ONT and connected devices. |
5GHz | Green | OFF | 5GHz WiFi service is disabled on ONT. |
WPS | Green | ON | WPS successful connection established (for 5 sec). |
WPS | Green | Slow Blink (1/sec) | WPS in progress. |
WPS | Green | OFF | Disabled or process successfully finished. |
UPS Connector Pinouts
The UPS connector has 8 pins with the following functions:
- Pin 1 (+VDC): Power input from UPS.
- Pin 2 (-VDC): Power return to UPS.
- Pin 3 (On Battery): Open signal when on battery power.
- Pin 4 (Signal Return): Connected to Signal GND on ONT.
- Pin 5 (Missing Battery): Open signal when battery not detected.
- Pin 6 (Replace Battery): Open signal when battery should be replaced.
- Pin 7 (GND): Connected to Signal GND on ONT.
- Pin 8 (Low Battery): Open signal when battery is low.
3. Installation
Follow these steps to install the DZS 2466GN:
- Remove the fiber service cover to expose the GPON port.
- Connect the fiber optic cable with an SC/APC termination to the GPON port.
- Re-attach the fiber service cover onto the 2466GN.
- Connect the telco cable from the POTS port to home phone lines.
- Connect the Ethernet cable from a GE port to a PC.
- Connect the power cable from the power port to an electrical outlet.
- (Optional) Connect the Battery Backup Unit power and telemetry to the UPS port.
Mounting on a Wall
If necessary, the ONT can be mounted on a wall using the provided mounting holes. The unit dimensions are approximately 9.91 inches (251.80 mm) in length, 5.83 inches (148.1 mm) in width, and 1.5 inches (38.4 mm) in height. Mounting hole spacing is not explicitly detailed but is indicated on the diagram.
4. Web Access
You can access the unit's configuration interface through a web browser:
- Connect an Ethernet cable from your computer to the GE1 port on the 2466GN.
- Launch a web browser or telnet session and navigate to the IP address
192.168.1.1
. - Enter the default username and password:
admin
/dzsi
.
For security, it is recommended to change the default password.
Regulatory Information
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) this device may not cause harmful interference, and (2) it must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, designed to provide reasonable protection against harmful interference in a residential installation. It generates, uses, and can radiate radio frequency energy. If not installed and used according to instructions, it may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation. If interference occurs, users are encouraged to correct it by reorienting or relocating the receiving antenna, increasing separation between equipment and receiver, connecting the equipment to a different circuit, or consulting a dealer or technician. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and should be installed and operated with a minimum distance of 20cm between the radiator and your body.
Industry Canada Statement
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to two conditions: (1) this device may not cause harmful interference, and (2) it must accept any interference received, including interference that may cause undesired operation. This device also complies with ICES-003 of the Industry Canada (IC) Rules. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, designed to provide reasonable protection against harmful interference in a residential installation. It generates, uses, and can radiate radio frequency energy. If not installed and used according to instructions, it may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation. If interference occurs, users are encouraged to correct it by reorienting or relocating the receiving antenna, increasing separation between equipment and receiver, connecting the equipment to a different circuit, or consulting a dealer or technician. This equipment complies with RSS-102 radiation exposure limits set forth for an uncontrolled environment and should be installed and operated with a minimum distance of 20cm between the radiator and your body.
A French version of the Industry Canada statement is also provided in the original document.