Instructions for HYDROQUIP models including: 4kW No-Fault Hot Tub Heater, 4kW, No-Fault Hot Tub Heater, Hot Tub Heater, Tub Heater, Heater

BX5951-Watkins-No-Fault-Double-Barrel-Heater-Installation-Instructions

Watkins No-Fault Heater Replacement Instructions

spadepot.com

Watkins Hot Spring No-Fault Heater Replacement Instructions

Watkins No-Fault Hot Tub Heater for Hot Spring Spas - 4kW – SpaDepot.com


File Info : application/pdf, 1 Pages, 311.76KB

PDF preview unavailable. Download the PDF instead.

BX5951-Watkins-No-Fault-Double-Barrel-Heater-Installation-Instructions
SpaDepot.com
WARNING! Removing the product label, disassembling, altering or damaging heater (including dry/wet firing
heater) voids the product warranty
WARNING! This electrical device should be installed by an electrician or qualified pool/spa technician. If you are
not qualified or do not have the knowledge to install this product correctly, stop! and contact your heater provider
for assistance
STEPS FOR A SUCCESFULL INSTALLATION
1. Using the Heater Cross Reference Matrix, confirm the number on the heater data label (HQ part #) is the correct replacement for the heater being removed from the spa Do Not Replace heaters that are not correctly matched
HEATER CROSS REFERENCE MATRIX
2. Inspect heater for shipping or other damage. Do not attempt to install a heater that's damaged, repaired or appears to be altered in any way 3. Turn heater temperature to off, turn off circuit breaker to spa and be certain the electrical power has been disconnected before performing this service 4. After removing the old heater, place the new heater and secure all plumbing using existing clamps. Make sure plumbing lines are not blocked or kinked when finished 5. A tubing kit has been provided to extend the bleed line when required on some models 6. Re-connect the new temp sensor, high limit sensor and electrical power connections to the same location and manner as removed, making sure all connections are tightly secured. If your old heater had a pressure switch, this should be jumped on the circuit board. 7. Re-connect bare copper bonding wire to provided ground lug on the heater support leg 8. Fill spa and restore power. Turn on pump and test for leaks 9. Turn heater on and verify the system operates properly NOTE: The heater should never be allowed to operate without proper water flow. Heaters that have been dry or wet fired from improper installation, lack of water flow or alteration will not be covered by warranty
#85-0124 Rev.01



References

Microsoft Word 2013