Instruction Manual for UNI-T models including: UT801-802 Bench Type Digital Multimeter, UT801-802, Bench Type Digital Multimeter, Type Digital Multimeter, Digital Multimeter, Multimeter
Uni-T UT801 Benchtop Digital Multimeter | Huddleston Australia
LCD Display 1. Manual Range Indicator of manual range 2. Warning !Indicator for Warning signal 3. The battery is low 4. Indicator for high voltage signal
File Info : application/pdf, 2 Pages, 359.97KB
DocumentDocumentUT801/802 Operating Manual UT801/802 Operating Manual Bench Type Digital Multimeters Overview Digital Bench-Type Multimeter Model UT801 is the maximum reading 1999 and 3 1/2 digits and UT802 is the maximum reading 19999 and 4 1/2 digits, both models are in manual range, DC / AC current type digital multimeter, This is also the extra large characters in LCD display backlight with full function, full measurement and full overload protection as well as a good product design outlook, In addition to all the conventional features include DC/AC voltage, DC/AC current, resistance, frequency, capacitance, temperature , Transistor hFEdiode and continuity buzzer. This operating manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes strictly. Unpacking Inspection Open the package case and take out the Meter. Check the following items carefully to see any missing or damaged part. If you find any missing or damage, please contact your dealer in your country. Operating Manual 1 piece Test Lead 1 pair Alligator Clip 1 pair K Type Temperature Probe 1 piece ( For the temperature under 230testing) Multi-Purpose Socket 1 piece Power Cord 1 piece (AC220V 50Hz DC9V/200mA) Safety Information This Meter complies with the standards IEC61010-1 in pollution degree 2, overvoltage category (CAT II 1000V) and double insulation. If you can not follow up this operating instruction to use the meter and it reduces the chance to have an using protection. 1. Before using the Meter and Test Leads inspect both items. Do not use the Meter and Test Leads if it is damaged or the case (or part of the case) is removed or no reaction on LCD display. Prohibited to use the meter without housing or housing without screw fix up in order to avoid possible electric shock or to avoid possible damage to the meter or to the equipment under test. 2. If the damage of test leads, use only the same model number or identical electrical specifications replacement parts. 3. Do not use your finger to touch on any testing cable, connector, unused terminal input or circuit during the testing stage 4. When the meter working at an effective voltage over 60V in DC or 30V rms in AC, special care should be taken for there is danger of electric shock. 5. Selecting the correct terminal input and turn the rotary switch to select the measuring function. In case of no any idea on the value input of the current, just simply test from the high value to low one. 6. Do not overload voltage or current on EITHER between terminal and terminal OR between terminal and grounding which indicate on meter limitation. 7. The rotary switch should be placed in the right position and no any changeover of range shall be made during measurement is conducted to prevent damage of the Meter. 8. Do not use or store the meter in an environment of high temperature, humidity, flammable and electromagnetic environment. The performance of the meter may deteriorate after dampened. 9. The internal circuit of the meter shall not be altered at will to avoid damage of the meter and any accident 10. Replace the battery as soon as the battery indicator " "Appears. With a low battery, the meter might produce false readings that can lead to electric shock and personal injury. 11. Turn the meter off when it is not is use and take out the battery when not using for a long time. General Specifications 1. Maximum Voltage between terminal input and COM: 1000V( except 200mV, 230V) 2. A mA terminal input protection: (CE)250mA 265V auto recovery fuse 3. 10A terminal input protection: (CE)F1 (10A H 250V) Fast type melted fuse 5x20mm 4. Resistance input protection: PTC/250V 5. Capacitance input protection: (CE)F2, F3 (0.5A H 250V) Fast type melted fuse 5x20mm 6. Frequency input protection: PTC/250V 7. Temperature input protection: (CE)250mA 265V fuse 8. terminal input protection: PTC/250V 9. hFE input protection: (CE)250mA 265V auto recovery fuse, F3 (0.5A H 250V) Fast type melted fuse 5x20mm 10. Display: LCD full function signal display, maximum reading is 1999(UT801) , 19999(UT802) Updates 2-3 times / second 11. Range: Manual 12. Polarity Display: Auto 13. Overload indication: 1 14. Battery Deficiency: 15. Operating Temperature: 040(32104) 16. Storing Temperature: -1050(14122) 17. Relative Humidity: 030 below 75% 3040 50% 18. Electromagnetic Field: Under 1V/m the influence of radiated radio-frequency electromagnetic field phenomenon, Total accuracy= specific accuracy+ measurement 5%, Over 1V/m radiated radio- frequency electromagnetic which do not have any reference data on this topic. 19. Power: AC(external power adapter AC220V/ DC9V-200mA) or DC(internal battery type 2 R14/1.5V 6 pieces) 20. Product size: (300x245x105)mm 21. Product Net Weight : About1500g(without the accessories) 22. Safety Compaliances : IEC 61010: CAT1000V LCD Display 1. Manual Range Indicator of manual range 2. Warning Indicator for Warning signal 3. The battery is low 4. Indicator for high voltage signal 5. Indicator for Negative reading display 6. AC Indicator for AC voltage or current ( DC indicator do not display) 7. Data hold is active 8. Test of diode 9. The continuity buzzer is on 10. Number Indicates testing reading 11. Units of measurement: mV, V Unit of Voltage: The millivolt, volt A, mA, A Unit of current: Microampere, milliampere, ampere , k, M Unit of electrical resistance: Ohm, thousand ohms, trillion ohm nF/F Unit of electrical capacity: Accepts the farad, the microfarad kHz Unit of Frequency: Kilohertz Unit of Temperature: Degree Celsius Factor Unit of Triode enlargement: Times Functions Symbol Terminal Input Explanation V V COM DC Voltage Measurement V V COM AC Voltage Measurement V COM Resistance Measurement V COM Diode / Continuity Buzzer Measurement kHz V COM Frequency Measurement A mA A COM mA/A DC Current Measurement 10A COM ADCCurrent Measurement A mA A COM mA/A AC Current Measurement 10A COM A AC Current Measurement F V mA A Capacitance Measurement (Use Multi-Purpose Socket) V mA A Temperature Measurement (Use Multi-Purpose Socket) hFE V mA A Triode Enlargement Factor (Use Multi-Purpose Socket) Measurement Functional Buttons Turn the power on and off Turn the display backlight on and off(suitable for battery LIGHT supply, backlight turn on about 10 seconds after auto shut down.) HOLD Press Hold to enter and exit the hold mode in any mode, the meter beeps. Operational Measurement Guide (see Diagram 1, 2, 3) Diagram 1 Diagram 2 Diagram 3 P/N: 110401101618 Warning: 1. Selecting the correct terminal input and turns the rotary switch to select the measuring function. If fails to do that, the buzzer beep and the warning signal flash on. Range Alarm Alert On False Terminal Input V Hz mAA hFE F 10A mAA 10A 10A mAA 2.DC or AC Voltage Measurement To avoid harms to you or damages to the Meter from electric shock, please do not attempt to measure voltages higher than 1000 V although reading may be obtained. The Meter has an input impedance of 10M(exceptUT802/ACV input impedance of 2M) This loading effect can cause measurement errors in high impedance circuits and so you need to take a note on it. 3.DC or AC Current Measurement Before connect the Meter in serial with the tested return circuit, closed the return circuit current to avoid the dangerous of sparking. Do not use over >10A current measurement. Although the meter can work on below 20A current testing but for the avoiding any harms to you or damages to the Meter. 4.Measuring Resistance, Diodes, Continuity or Capacitance To maintain the measurement accuracy, discount circuit power and discharge all the high voltage capacitors during the measuring resistance. When measuring high resistance on 1M or above, it is normal to take several seconds to obtain a stable reading. In order to obtain stable reading, choose shorter test lead to carrying out measurement. The test leads and the Meter inside wire will bring around 0.10.2 of error to resistance measurement when measuring low resistance. To obtain accurate readings in low-resistance, short circuit the test leads beforehand and record the reading obtained, call this reading as X. Then use the equation: measured resistance value (Y) (X) = accurate readings of resistance. During measurement, Diodes is in a good silicon junction drops between 500mV800mV as the normal value. The continuity measurement, the poles between resistance is >100. it is a short circuit, but on the poles between resistance is 10, it is a good connection, buzzer is continually beep on, and the reading value is nearly to the circuit resistance value, Unit is . Accuracy Specifications Accuracy: ±(% reading + digits), guarantee for 1 year Operating temperature: 1828 Environmental humidity: Less than 75%RH 1. DC Voltage Range Resolution Accuracy Tolerance:±(% Reading+Digits) UT801 UT802 UT801 UT802 200mV 0.1mV 0.01mV ±(0.1%+5) 2V 1mV 0.1mV 20V 10mV 1mV ±(0.5%+2) ±(0.1%+3) 200V 100mV 10mV 1000V 1V 0.1V ±(0.8%+3) ±(0.2%+5) Input Impedance: is average on 10M Maximum Voltage Input: 1000V (Except 200mV, 250V) 2. AC Voltage Range Resolution Accuracy Tolerance:±(% Reading+Digits) UT801 UT802 UT801 UT802 2V 1mV 0.1mV ±(0.8%+3) ±(0.5%+20) 20V 10mV 1mV 200V 100mV 10mV ±(1.0%+4) ±(0.8%+40) 1000V 1V 0.1V Input Impedance: UT801 is average on 10M , UT801/802 Operating Manual UT802 is about 2M . Maximum Voltage Input: 750Vrms Frequency: 45Hz400Hz Display: True RMS 3. DC Current Range Resolution Accuracy Tolerance:±(% Reading+Digits) UT801 UT802 UT801 UT802 200A 0.1A 0.01A 2mA 1A 0.1A 20mA 10A 1A ±(0.8%+2) ±(0.5%+20) 200mA 0.1mA 0.01mA 10A 10mA 1mA ±(2.0%+4) ±(1.5%+40) * When 5A, Continuous measurement less than 10 seconds at an interval more than 15 minutes. 4. AC Current Range Resolution Accuracy Tolerance:±(% Reading+Digits) UT801 UT802 UT801 UT802 2mA 1A 0.1A 20mA 10A 1A ±(1.0%+3) ±(0.8%+40) 200mA 0.1mA 0.01mA 10A 10mA 1mA ±(2.5%+5) ±(2.0%+40) Frequency: 45Hz400Hz * When 5A, Continuous measurement less than 10 seconds at an interval more than 15 minutes. 5. Resistance Range Resolution Accuracy Tolerance:±(% Reading+Digits) UT801 UT802 UT801 UT802 200 0.1 0.01 2k 1 0.1 20k 10 1 ±(0.8%+3) ±(0.5%+10) 200k 100 10 2M 1k 100 20M 10k ±(1.2%+5) 200M 10k ±(5%+40) When >100M resistance measurement as reference purpose. 6. Capacitance Range Resolution Accuracy Tolerance:±(% Reading+Digits) UT801 UT802 UT801 UT802 20nF 10pF 1pF 2F 1nF 100pF ±(4%+3) ±(4%+10) 200F* 100nF 10nF ±(5%+5) ±5%+10) *>40F capacitance measurement as reference purpose. 7. Frequency Range Resolution Accuracy Tolerance:±(% Reading+Digits) UT801 UT802 UT801 UT802 2kHz 1Hz 0.1Hz ±(1.5%+5) 200kHz 100Hz 10Hz ±(1.2%+10) Input Amplitude a: (2kHz range) 50mVa30Vrms (200kHz range)150mVa30Vrms 8. Temperature Range Resolution Accuracy Tolerance:±(% Reading+Digits) UT801 UT802 UT801 UT802 -40-20 -(8%+5) -(8%+40) >-200 1 0.1 >0100 ±(1.2%+4) ±(1.2%+30) ±(1.2%+3) ±(1.2%+25) >1001000 ±(2.5%+2) ±(2.5%+20) * Thermocouple: It is suitable to use K type thermocouple. This include point contact K type thermocouple can only be used on less than 230 temperature measurement. 9. Diode Test Range Resolution UT801 UT802 1mV 0.1mV Remarks Open circuit voltage is around 3 V, Silicon junction drops between 0.50.8V as the normal value. 10. Continuity Test Range Resolution Remarks UT801 UT802 O p e n c i r c u i t v o l t a g e i s 1* 0.1* approximate 3V When circuit disconnected with resistance value >100, buzzer does not beep. When circuit is in good connection with resistance value 10, buzzer beeps continuously. 11. Transistor hFE Range Resolution UT801 UT802 hFE 1* 0.1* Remarks Ib0 is about 10A, Vce is about 2.5V Replacing the battery(see Diagram 4) R14 1.5V*6 Power adapter Fuse Diagram 4 Specifications and other information shown on this instruction manual are subject to change without notice Development District,Hu Men Town,Dong Guan City, Guang Dong Province,ChinaGPL Ghostscript 9.50 Adobe InDesign CS3 (5.0)