User Guide for TECHCON models including: TS5000DMP-DCX Series Disposable Material Path Rotary Auger Valve, TS5000DMP-DCX Series, Disposable Material Path Rotary Auger Valve, Material Path Rotary Auger Valve, Path Rotary Auger Valve, Rotary Auger Valve, Auger Valve, Valve

Techcon TS5000DMP-DCX-SL Disposable Material Path Rotary Valve User Guide & Warranty

Techcon TS5000DMP-DCX-SR Disposable Material Path Rotary Valve, Slim Right Hand Body

Techcon TS5000DMP-DCX-SL Disposable Material Path Rotary Valve, Slim Left Hand Body


File Info : application/pdf, 8 Pages, 605.60KB

PDF preview unavailable. Download the PDF instead.

techcon-ts5000dmp-dcx-user-guide-warranty
Techcon TS5000DMP-DCX Series Disposable Material Path Rotary Auger Valve
User Guide

CONTENTS
Page number 1. Specifications...........................................................................3 2. Unpacking and Inspection.............................................................4 3. Description................................................................................4 4. Theory of Operation....................................................................5 5. Set-Up Instructions.....................................................................6 6. Typical Set-Up...........................................................................7 7. Determining Dispensing Output...................................................8-9 8. DMP Removal/Replacement..........................................................9 9. Spare Parts..............................................................................10 10. DMP Insert Options.....................................................................11 11. Accessories................................................................................11 12. Trouble Shooting........................................................................12 13. Warranty................................................................................13
2

1. SPECIFICATIONS

TS5000DMP-DCX-

TS5000DMP- DCX-SL TS5000DMP- DCX-SR

Size

5.88'' Length X 3.56''

5.88'' Length X 3.56''

5.88'' Length X 3.56''

(149.35mm X 90.42mm) (149.35mm X 90.42mm) (149.35mm X 90.42mm)

Weight

0.73 lb (331g)

0.73 lb (331g)

0.73 lb (331g)

Body width
Door open location Fluid Inlet Port Fluid Outlet Port
Maximum Fluid Pressure

1.56" (39.6mm) Right hand side Female Luer lock Male Luer Lock
30 psi (2bar)

1.30" (33mm) Left hand side Female Luer lock Male Luer Lock
30 psi (2bar)

1.30" (33mm) Right hand side Female Luer lock Male Luer Lock
30 psi (2bar)

Operating Frequency

Exceeds 300 cycles/min. Exceeds 300 cycles/min. Exceeds 300 cycles/min.

Mounting

1'' (25.4mm) Channel

1'' (25.4mm) Channel

1'' (25.4mm) Channel

Wetted Parts Delrin®, Nylon, Viton® Delrin®, Nylon, Viton® Delrin®, Nylon, Viton®

Viscosity Range

30,000cps ­ 1,300,000cps 30,000cps ­ 1,300,000cps 30,000cps ­ 1,300,000cps

3

Encoder DMP Options
Techcon can offer the TS5000DMP-DCX with an encoder fitted to the DC motor. This configuration is available with a right hand side door opening. Due to machine integration restrictions, the encoder option is available with the flexibility of 3 encoder positions:

PART NUMBER TS5000DMP-E TS5000DMPE-0 TS5000DMPE-15

DESCRIPTION DMP Valve With 105° Encoder position DMP Valve With 0° Encoder position DMP Valve With 15° Encoder position

For spare parts, technical drawings, dimensional drawings, wiring diagrams or encoder information, relating to the encoder valve option, please contact Techcon.
2. UNPACKING AND INSPECTION
Carefully unpack the valve and examine the items contained in the carton. These will include:
 Valve assembly  Valve bracket and syringe bracket  Sample syringe kit and tip kit  Sample DMP feed screw/chamber (1 each of 6, 8 and 16-pitch)  User guide Inspect the unit for any damaged which may have occurred in transit. If such damage has occurred, notify the carrier at once. Claim for damage must be made by the consignee to the carrier, and should be reported to the manufacturer.
3. DESCRIPTION
The TS5000DMP-DCX Series Rotary Microvalve takes a revolutionary unique approach to solving some of the most difficult dispensing problems. Twocomponent fluids present a significant dispensing challenge, and the possibility of destroying precision valve components, upon premature curing. Highly abrasive fluids eventually decrease accuracy that is followed by total valve failure. With the patented Disposable Material Path (DMP) Rotary Microvalve from Techcon Systems, those concerns are erased.
A precision molded feed screw and chamber is captured in a "clamshell" design valve housing. Inexpensive disposable feed screw and chamber components may be changed quickly and easily. Cleanup is reduced to simply changing out the disposable material path. An inexpensive stock of disposable valve components replaces an inventory of back up valves.
The accuracy of the TS5000DMP-DCX valve meets the needs of users previously constrained to lower accuracy of time/pressure dispensing. It also meets the maintenance cost targets of users previously relegated to recurring, maintenance of non-disposable path valves. Current TS5000 Rotary Microvalve customers may find the accuracy of the TS5000DMP-DCX valve meet their current accuracy specifications.

4

13. LIMITED WARRANTY
Manufacturer warrants this product to the original purchaser for a period of one (1) year from date of purchase to be free from defects in material and workmanship, but not against damages by misuse, negligence, accident, faulty installations and instructions. Manufacturer will repair or replace (at factory's option), free of charge, any component of the equipment thus found to be defective, on return of the component, "PREPAID" to the factory during the warranty period. In no event shall any liability or obligation of the Manufacturer arising from this warranty exceed the purchase price of the equipment. This warranty is only valid if the defective product is returned as a complete assembly without physical damage. The Manufacturer's liability, as stated herein, cannot be altered or enlarged except by a written statement signed by an officer of the company. In no event shall the Manufacturer be liable for consequential or incidental damages. A return authorization is required from Techcon prior to shipping a defective unit to the factory.
Manufacturer reserves the right to make engineering product modifications without notice.
All returns must be issued with a Returns Authorization number, prior to return. Send warranty returns to:
Americas and Asia
OK International 10800 Valley View Street Cypress, CA 90630 USA
Europe
OK International Eagle Close Chandler's Ford Ind Est Eastleigh Hampshire SO53 4NF United Kingdom
Delrin®, Viton® and Teflon® are registered trademarks of E.I. DuPont.
T9000119_D
13

12. TROUBLE SHOOTING

PROBLEM No Fluid Flow
Inconsistent Fluid Flow

POSSIBLE CAUSE

CORRECTION

Dispense tip is plugged

Replace tip

Motor does not receive signal

Make sure all connections are secured

Motor running in reverse
Syringe barrel of dispense fluid is empty

Reverse motor cable connection
Replace with new syringe barrel, of fluid

Fluid feed pressure is too low Increase feed pressure.

Feed screw damaged

Replace with new feed screw/chamber

Fluid pressure fluctuating

Make sure fluid pressure is constant

Valve on time is too short

Increase valve on time

Excessive motor reverse time

Reduce reverse time or turn off completely.

Fluid drools after the valve turned off

Air trapped in fluid housing

Dispense tip clogged

Air trapped in feed screw chamber Air trapped in fluid reservoir
Excessive fluid feed pressure

Tip contacting substrate

Purge valve properly
Purge valve properly
Remove air from reservoir Reduce pressure or turn off pressure when the valve is idle. Increase dispense height

12

4. THEORY OF OPERATION (refer to figure 1.0)
The TS5000DMP-DCX Series Rotary Microvalve dispenses fluid with a positive displacement action using a rotary feed screw principle. Fluid is held in a feed reservoir (2), normally a syringe barrel or cartridge, under a positive head of air, between 1 to 20 psi (0.07 to 1.38bar), depending upon the viscosity of the fluid. The positive air pressure, supplied by the air line (1), forces the fluid out of the syringe barrel (2) into the material feed path (3) then to the feed screw chamber (5). Fluid flows from this point (5) to the dispense point (4) and is controlled by the feed screw rotation in the feed direction. The feed screw is driven by the DC motor (6). Applying a DC voltage signal to the DC motor (6), will rotate the feed screw and the fluid will be forced out the dispense tip (4). The actual fluid deposited is dependent upon adhesion of the dispensed fluid to the substrate. Shearing of the fluid is achieved by reverse Z-motion (tip retraction). When the motor stops, the unit remains in position for a fraction of a second (dwell) to allow the last drop of fluid to flow out of the dispense tip. After the dwell period, the automation equipment moves the TS5000DMP-DCX valve to the next position.
Figure 1.0
5

5. SET-UP INSTRUCTIONS
Mechanical Mounting: Normally, the TS5000DMP-DCX Series valve is used on an automated XYZ table, with full motion control in the three planes. It is very important that the valve is mounted on the Z-axis gantry, in a secure manner, that will not allow loosening during dispense operation. The Z-axis must move in a precise and repeatable motion for successful dispensing.
The provided mounting bracket, or customer supplied bracket, must be attached to the Z-axis in a manner that will provide the valve perpendicular travel to the horizontal plane of the surface on which the fluid will be dispensed. The mounting should provide a means of accurately adjusting the distance between the dispense tip and the substrate surface such as a touchdown sensing device or a fixed distance standoff.
Air Connection: Filtered air supply must be precisely regulated and should be set between 1-20 psi (0.07 to 1.38bar). The air supply is not used as the main dispensing force. It is only required to move fluid to the feed screw chamber.
Electrical Connection: The TS5000DMP-DCX Series valve requires an electrical connection of two wires for the DC motor. The motor lead wires are 24'' (609.60mm) in length. The black lead wire should be connected to the negative or neutral lead from the motor control voltage source. To verify the connection, check the rotation direction of the feed screw. When correctly connected, a positive voltage signal will drive the feed screw in a counter clockwise direction when view from the dispense tip end.
The recommended controller for the TS5000DMP-DCX Series valve is the TS500R. If another controller is used make sure the control voltage signal is precisely controlled. The signal should be from a regulated power supply and should be shunted to positive motor stop. Below is a diagram of a simple braking circuit:

10. DMP INSERT OPTIONS

PART NUMBER DMP6-10 DMP6R-10 DMP8-10 DMP8R-10 DMP16-10 DMP16R-10

DESCRIPTION 6 Pitch DMP Assembly, Fixed Red Collar, 10 per pack 6 Pitch DMP Assembly, Rotating Red Collar, 10 per pack 8 Pitch DMP Assembly, Fixed Black Collar, 10 per pack 8 Pitch DMP Assembly, Rotating Black Collar, 10 per pack 16 Pitch DMP Assembly, Fixed Blue Collar, 10 per pack 16 Pitch DMP Assembly, Rotating Blue Collar, 10 per pack

11. STANDARD ACCESSORIES

PART NUMBER 5000-000-005 5000-015-000 TS3706 TSD1135-18 71003RHB 73003RHB

DESCRIPTION Valve Mounting Bracket TS-SS Sample Tip Kit Syringe Bracket Kit 6 Pin DIN Socket 10cc Receiver Head, 3ft (0.9M) 30cc Receiver Head, 3ft (0.9M)

11.1 OPTIONAL ACCESSORIES

PART NUMBER TN00DKIT 9000-000-112 5000-000-082

DESCRIPTION Complete Dispensing Tip Kit Sample Tip Kit TS-SS Tip Torque Tool

Figure 2.0

6

11

9. SPARE PARTS

NOTE: When replacing the motor (6) and square drive (8), Loctite #86 AVV must be used, to bond the square drive to the motor shaft. The square drive must be flush with the end of the motor shaft and any visible excess must be cleaned off.
Figure 5.0

6. TYPICAL SYSTEM SET-UP

Figure 3.0

ITEM 1 2 3 4 5 6 7 8 9 10 11 12 12* 13

PART NUMBER TSD1415-12 TSD1401-7 5000-000-171 TSD1103-334 5000-000-346 TSD1412-61 T1000295 2200-000-011 TSD1103-330 TSD1103-14 TSD1103-10 A0100167 A0100184 See Section 10

DESCRIPTION Cable Bushing Sleeve Cap Cap Screw Motor Sleeve Motor Motor Mounting Plate Square Drive Mounting Plate Screws Body Screw, Long Body Screw, Short Body For TS5000DMP-DCX Body For TS5000DMP-DCXL DMP Insert

10

QTY 1 1 1 4 1 1 1 1 3 1 1 1 1 1

Dimensions are in inches (mm)
Figure 4.0 7

7. DETERMINING DISPENSING OUTPUT
A. DC Motor Voltage Level: Voltage controls the motor speed (RPM). Increased voltage produces increased motor speed and decreased voltage produces decreased motor speed.
B. Motor Shaft Speed: Motor gear ratio configuration determines final shaft speed. High RPM = High Output. Low RPM = Low Output.
C. Feed Screw Pitch: Rate of fluid dispensed is determined by the pitch of the feed screw. A high pitch number will produce a low dispense rate and a low pitch number will produce a higher dispense rate. A high pitch number will provide improved accuracy than a low pitch number.
D. Dispense Tip: The size of the dot diameter or bead width is determined by the dispense tip. A low gauge number (larger I.D.) will dispense a large diameter dot or a wide bead. A high gauge number (smaller I.D.) will dispense a smaller diameter dot or a narrower bead. Dispense tip sizes smaller than 25 gauge and longer than ½" (12.7mm) are not recommended to use with solder paste. A normal "rule of thumb", to choose the dispense tip size, is that the dot size will equal 1.5 times the internal diameter of the dispense tip. For setting the dispense tip distance from the substrate, the normal "rule of thumb" is to set the distance at ½ the internal diameter of the tip being used.
E. Fluid Feed Pressure: The fluid feed pressure does affect the amount of fluid dispensed through the valve. Optimum feed pressure is dependent upon the viscosity of the fluid being dispensed. Only in unusual circumstances should the feed pressure exceed 30 psi (2bar).
F. Dispense Fluid: The viscosity of the dispense fluid along with the particulate additives to the dispense fluid will also determine the dispense rate. The ability to dispense may be directly related to the fluid formulation.
G. Dispense Cut Off: The best method of stopping fluid flow at the end of the cycle is to short the motor (grounding the DC voltage signal through a current limiting resistor). This method provides a complete rotational brake of the motor at the shut off point. Another method of stopping fluid flow is to reverse the motor rotation by reversing the DC voltage signal. This can be described as "suck-back" action. In both cases, a nodrip dispensing action can be achieved. Turning off the fluid feed pressure when the valve is not dispensing will prevent dripping and oozing, with fluids at the lower end of the TS5000DMP-DCX viscosity range.
H. Fluid (Material) Condition: The physical condition of the dispense fluid is very important to successful dispensing. There are a number of conditions that can prevent continuous and consistent dispensing such as:
8

1. Freshness: Old fluid (most fluid have a recommended shelf life) leads to erratic dispensing and frequent clogging, especially with solder paste. Make sure to check the fluid shelf life before start dispensing.
2. Separation: Fluid with a high content of solid particles, such as solder paste, tends to separate at high pressure. If the dispense fluid starts to separate, replace it with new fresh fluid.
3. Particle sizing: Do not attempt to dispense solder paste with particle sizes larger than 75 microns (-200+325 mesh size).
8. DISPOSABLE MATERIAL PATH REMOVAL/REPLACEMENT:
Removal of a feed path assembly: Refer to figure 1.0 1. Release fluid pressure by disconnecting the air hose (1). 2. Remove syringe barrel of fluid (2) from the valve. 3. Remove dispense tip (4). 4. Loosen the thumb screw and pull the housing door open. 5. Rotate the feed screw/chamber assembly (3/5) about 30 degrees to the right
(left for left hand side door opening) and pull it, in a downwards direction, away from the motor shaft. 6. Dispose of the used feed path assembly (3/5) in an appropriate waste container.
Installation of a new feed path assembly: Refer to figure 1.0 1. Insert a new feed path assembly (3/5) into the valve housing. Ensure the square
drive of the motor shaft engages into the feed screw collar correctly. 2. Rotate the feed path assembly (3/5) until the material inlet port engages into the
housing groove. 3. Close the housing door and tighten the thumb screw.
Valve Purging
CAUTION: Improper purging can cause air entrapment inside feed screw/chamber assembly.
1. Attach a syringe barrel of dispensing conditioner, either part number 7105XCON (10cc) or 7305XCON (30cc), to the valve inlet.
2. Apply 8 psi (0.55 bar) pressure onto the syringe barrel and allow the pressure to push the conditioner through the valve, for 2 minutes. Do not apply more than 10 psi (0.69 bar) on the conditioner when priming as this may cause compressed air pockets in the valve chamber.
3. Turn on the motor and let it run, until a steady stream of fluid is being dispensed.
4. Turn off the motor and install the appropriate dispense tip to the valve outlet. Do not over tighten the dispense tip. For TS-SS Series dispense tips a torque tool is available, part number 5000-000-082.
5. Turn on the motor and let it run until a steady stream of fluid is being dispensed.
9

