ROVSUN PORTABLE AIR CONDITIONER

Instruction Manual

BRAND:ROVSUN

MODEL:JHS-A019G-05KR-D3 / JHS-A019G-06KR-D3

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY. RETAIN THIS MANUAL FOR FUTURE REFERENCE.

I. Notes

II. Features and Components

1. Features

2. Components:

A diagram shows the components of the air conditioner, including:

III. Control Setting

1. Control panel operation instructions

1) Operation interface:

The control panel features buttons for:

Button Functions:

2. Operation instructions of remote control

1) The remote controller is as follows:

A diagram of the remote control shows buttons for:

Button Functions:

V. Protection function

VI. Installation and adjustment

1. Installation:

Warning: before using the mobile air conditioning, keep it upright for at least two hours. The air conditioning can be easily moved in the room. In the moving process, ensure that the air conditioning is in the upright position and the air conditioning should be placed on a flat surface. Do not install and use the air conditioning in the bathroom or other humid environments.

1.1 Install the heat pipe assembly (as shown in Fig.1)

A diagram (Figure 1) illustrates the installation of the heat pipe assembly. The process involves:

1.2 Installation of window sealing plate components

A diagram (Figures 2 and 3) illustrates the installation of the window sealing plate assembly. The process involves:

Notes:

1.3 Install the unit:

A diagram (Figure 4) shows the unit placement. The machine should be placed before the window with the heat pipe and fittings installed. The distance between the body and walls or other objects shall be at least 50 cm.

Diagrams (Figures 5 and 6) illustrate connecting the exhaust pipe to the window sealing plate assembly. The process involves:

Notes:

VII. Drainage Instructions

1. Manual drainage:

Notes:

2. Continuous drainage (only applicable to cooling and dehumidification mode):

VIII. Maintenance

Cleaning: before cleaning and maintenance, turn off the machine and unplug the unit from the power source.

1. Clean the surface

Clean the surface of the machine with a wet soft cloth. Do not use chemicals, such as benzene, alcohol, gasoline, etc.; otherwise, the surface of the air conditioning will be damaged or even the whole machine will be damaged.

2. Clean the filter screen

If the filter screen is clogged with dust, and the effectiveness of the air conditioning is reduced, be sure to clean the filter screen once every two weeks.

3. Clean the upper filter screen frame

IX. Troubleshooting

Do not repair or disassemble the air conditioning by yourself. Unqualified repair will lead to failure of the warranty card, and may cause damage to users or their properties.

Problems Reasons Solutions
The air conditioning does not work. There is no electricity. Turn it on after connecting it to a socket with electricity.
The overflow indicator displays "FL". Discharge the water inside.
The ambient temperature is too low or too high. Recommend to use the machine in at the temperature of 7-35 °C (44-95 °F).
The cooling or heating effect is not good. In cooling mode, the room temperature is lower than the set temperature; in heating mode, the room temperature is higher than the set temperature. Change the set temperature.
In dehumidification mode, the ambient temperature is low. The machine is placed in a room with an ambient temperature of greater than 17 °C (62 °F).
Big Noise There is direct sunlight. Pull the Curtain.
Doors or windows are open; there are a lot of people; or in cooling mode, there are other sources of heat. Close doors and windows, and add new air conditioning.
The filter screen is dirty. Clean or replace the filter screen.
The air inlet or outlet is blocked. Clear obstructions.
The air conditioning is not placed on a flat surface. Put the air conditioning on a flat and hard place (to reduce noise).
Compressor does not work. Overheat protection starts. Wait for 3 minutes until the temperature is lowered, and then restart the machine.
The remote control does not work. The distance between the machine and the remote control is too far. Let the remote control get close to the air conditioning, and make sure that the remote control directly faces to the direction of the remote control receiver.
The remote control is not aligned with the direction of the remote control receiver. Make sure that the remote control directly faces to the direction of the remote control receiver.
Batteries are dead. Replace batteries.
Displays 'E1'. The room temperature sensor is abnormal. Check the room temperature sensor and related circuitry.
Displays 'E2'. The pipe temperature sensor is abnormal. Check the pipe temperature sensor and related circuitry.
Bluetooth connection unavailable. The connection is not correct. 1. When using Bluetooth mode for the first time, it can only be used after the 2.4G WiFi network is connected successfully.
2. After the WiFi connection is disconnected, wait about 2-3 minutes before you can directly use the Bluetooth control.

If problems not listed in the table occur or recommended solutions do not work, please contact the professional service organization or contact Customer Service for additional support.

Models: JHS-A019G-05KR-D3, JHS-A019G-06KR-D3, JHS-A019G-05KR-D3 Portable Air Conditioner, JHS-A019G-05KR-D3, Portable Air Conditioner, Air Conditioner, Conditioner

File Info : application/pdf, 16 Pages, 1.86MB

PDF preview unavailable. Download the PDF instead.

Instruction manual of ROVSUN 8000BTU Portable AC ?v=1711346413 福昕高级PDF编辑器打印机 版本 9.2.0.1151

Related Documents

Preview ROVSUN Split Type Air Conditioner Instruction Manual
Comprehensive instruction manual for the ROVSUN Split Type Air Conditioner, covering safety precautions, parts identification, operation, installation, maintenance, and troubleshooting.
Preview ROVSUN Split Type Air Conditioner Instruction Manual
This manual provides comprehensive instructions for the installation, operation, and maintenance of ROVSUN Split Type Air Conditioners. It includes safety precautions, parts identification, remote control functions, operational guidelines, installation procedures, test operations, maintenance tips, and troubleshooting guidance.
Preview ROVSUN Split Type Air Conditioner Instruction Manual
This instruction manual provides important information and recommendations for obtaining the best results from your ROVSUN Split Type Air Conditioner. It covers safety precautions, parts identification, remote control operation, installation, test operation, maintenance, and troubleshooting.
Preview ROVSUN YPE-12C Portable Air Conditioner User's Manual
User's manual for the ROVSUN YPE-12C Portable Air Conditioner, covering safety instructions, product description, control panel, remote control, operation, installation, drainage, cleaning, and troubleshooting.
Preview ROVSUN Split Type Air Conditioner Instruction Manual
This instruction manual provides essential information and recommendations for operating your ROVSUN split type air conditioner to ensure optimal performance and longevity. It covers safety precautions, parts identification, remote control operation, installation, maintenance, and troubleshooting.
Preview ROVSUN Split Type Air Conditioner Instruction Manual
This manual provides comprehensive instructions for the installation, operation, and maintenance of ROVSUN Split Type Air Conditioners. It covers safety precautions, parts identification, remote control functions, operating modes, installation procedures for indoor and outdoor units, test operations, maintenance guidelines, and troubleshooting.
Preview ROVSUN Window Air Conditioner User Manual: Installation, Operation, and Troubleshooting
Comprehensive user manual for ROVSUN Window Air Conditioners (8000, 10000, 12000 BTU). Includes installation guides, operating instructions, safety precautions, and troubleshooting tips.
Preview ROVSUN Mini Split Air Conditioner Installation and Service Manual (R454B)
Comprehensive guide for ROVSUN multi-zone mini-split air conditioners, covering installation, servicing, safety precautions, troubleshooting, and disposal. Features R454B refrigerant and multi-zone systems.