Instruction Manual for E E ELEKTRONIK models including: EE212D Modular Humidity and Temperature Sensor, EE212D, Modular Humidity and Temperature Sensor, Humidity and Temperature Sensor, Temperature Sensor, Sensor
Modular Humidity and Temperature Sensor
File Info : application/pdf, 8 Pages, 205.85KB
DocumentDocumentPICS EE212D BACnet Protocol Implementation Conformance Statement PICS_EE212D // v1.0 / Modification rights reserved Content 1. GENERAL INFORMATION ...................................................................................... 3 2. BACNET STANDARDIZED DEVICE PROFILE (ANNEX L) ................................. 3 3. LIST OF ALL SUPPORTED BACNET INTEROPERABILITY BUILDING BLOCKS (ANNEX K): ........................................................................... 3 4. SEGMENTATION CAPABILITY:.............................................................................. 3 5. BACNET STANDARD OBJECT TYPES SUPPORTED ........................................ 3 6. DATA LINK LAYER OPTIONS................................................................................. 4 7. DEVICE ADDRESS BINDING.................................................................................. 4 8. NETWORKING OPTIONS ........................................................................................ 4 9. NETWORK SECURITY OPTIONS .......................................................................... 4 10. CHARACTER SETS SUPPORTED ......................................................................... 4 11. TRANSMITTER DIFFERENCES ............................................................................. 4 12. BACNET OBJECTS.................................................................................................. 5 12.1 Device Object ..................................................................................................................5 12.2 Analog Input Objects .......................................................................................................6 13. MISCELLANEOUS INFORMATION ....................................................................... 7 2 1. GENERAL INFORMATION Date: Vendor Name: Product Name: Product Model Number: Application Software Version: Firmware Revision: BACnet Protocol Version: BACnet Protocol Revision: 02.06.2022 E+E Elektronik EE212D EE212D This is the generic denomination for EE212 devices with digital output (RS485) and BACnet MS/TP protocol. For type number of specific EE212D devices see the respective data sheet at: https://www.epluse.com/fileadmin/data/product/ee212/datasheet_EE212.pdf 2.0 2.0 1 14 Product Description: Humidity and Temperature BACNet MS/TP Smart Sensor Master device EE212D. 2. BACNET STANDARDIZED DEVICE PROFILE (ANNEX L) BACnet Operator Workstation (B-OWS) BACnet Advanced Operator Workstation (B-AWS) BACnet Operator Display (B-OD) BACnet Building Controller (B-BC) BACnet Advanced Application Controller (B-AAC) BACnet Application Specific Controller (B-ASC) BACnet Smart Sensor (B-SS) BACnet Smart Actuator (B-SA) 3. LIST OF ALL SUPPORTED BACNET INTEROPERABILITY BUILDING BLOCKS (ANNEX K): DS-RP-B ............. Data Sharing Read Property B DS-RPM-B .......... Data Sharing Read Property Multiple B DS-WP-B ............ Data Sharing Write Property B DS-COVU-B........ Data Sharing COV-Unsolicited B DM-DDB-B.......... Data Management Dynamic Device Binding B DM-DOB-B.......... Data Management Dynamic Object Binding B DM-DCC-B.......... Data Management Device Communication Control B DM-RD-B ............ Data Management Reinitialize Device B 4. SEGMENTATION CAPABILITY: Able to transmit segmented messages Able to receive segmented messages 5. BACNET STANDARD OBJECT TYPES SUPPORTED Accumulator Analog Input Analog Output Analog Value Averaging Binary Input Binary Output Binary Value Calendar Command Device Event Enrollment File Group Life Safety Point Life Safety Zone Loop Multistate Input Multistate Output Multistate Value Notification Class Program Pulse Converter Schedule Trend Log 3 6. DATA LINK LAYER OPTIONS BACnet IP, (Annex J): BACnet IP, (Annex J), Foreign Device: ISO 8802-3, Ethernet (Clause 7): ATA 878.1, 2.5 Mb. ARCNET (Clause 8): ATA 878.1, EIA-485 ARCNET (Clause 8), baud rate(s): MS/TP master (Clause 9), baud rate(s): 9600, 19200, 38400, 57600, 76800, 115200 MS/TP slave (Clause 9), baud rate(s): Point-To-Point, EIA 232 (Clause 10), baud rate(s): Point-To-Point, modem, (Clause 10), baud rate(s): LonTalk, (Clause 11), medium: BACnet/Zigbee (Annex O): Other: 7. DEVICE ADDRESS BINDING Is static device binding supported? (This is currently necessary for two-way communication with MS/TP slaves and certain other devices.) Yes No 8. NETWORKING OPTIONS Router, Clause 6 - List all routing configurations, e.g., ARCNET-Ethernet, Ethernet-MS/TP, etc. Annex H, BACnet Tunneling Router over IP BACnet/IP Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? Yes No Does the BBMD support network address translation? Yes No 9. NETWORK SECURITY OPTIONS Non-secure Device - is capable of operating without BACnet Network Security Secure Device - is capable of using BACnet Network Security (NS-SD BIBB) Multiple Application-Specific Keys Supports encryption (NS-ED BIBB) Key Server (NS-KS BIBB) 10. CHARACTER SETS SUPPORTED Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ISO 10646 (UTF-8) ISO 10646 (UCS-2) IBMTM /MicrosoftTM DBCS SO 10646 (UCS-4) ISO 8859-1 JIS X 0208 11. TRANSMITTER DIFFERENCES BACnet Objects Device Object Analog Input Object: Temperature Analog Input Object: Relative Humidity Analog Input Object: Water Vapor Partial Pressure Analog Input Object: Dew Point temperature Analog Input Object: Absolute humidity Analog Input Object: Mixing Ratio Analog Input Object: Enthalpy Analog Input Object: Frost Point Temperature Analog Input Object: Wet Bulb Temperature EE212D 4 12. BACNET OBJECTS This part describes the various BACnet objects in detail. The main properties of the individual objects are explained in the following sections. 12.1 Device Object Property Object Identifier Object Name Object Type Description System Status Vendor Name Vendor Identifier Model Name Firmware Revision Application Software Version Location Protocol Version Protocol Revision Data Type BACnetObjectIdentifier CharacterString[15] BACnetObjectType (Enum.) CharacterString[15] BACnetDeviceStatus (Enum.) CharacterString Unsigned16 CharacterString CharacterString CharacterString CharacterString[15] Unsigned Unsigned Protocol Services Supported BACnetProtocolServices Supported (Bit-String) Protocol Object Types Supported BACnetObjectTypes Supported (Bit-String) Object List BACnetARRAY[N] of BACnetPbjectIdentifier Property List BACnetARRAY[N] of BACnetPropertyIdentifier Max APDU Length Accepted Segmentation Supported APDU Timeout Number of APDU Retries Device Address Binding Database Revision Max Info Frames Max Master Communication Parameter Unsigned16 BACnetSegmentation (Enum.) Unsigned Unsigned List of BACnetAddressBinding Unsigned Unsigned Unsigned CharacterString R (R) ............. Required Property (Readable) R (W) ............ Required Property (Read-/Writable) O (R) ............. Optional Property (Readable) O (W) ............ Optional Property (Read-/Writeable) P (R) ............. Proprietary Property (Readable) P (W)............. Proprietary Property (Read-/Writeable) 5 Initial Value Unique Object Instance (0 4194302) "EE212D_XXXXXXXX" (X ... Unique characters) OBJECT_DEVICE "EE212D" STATUS_OPERATIONAL "E+E Elektronik" 623 "EE212D" "2.0" "2.0" R/O/P R (W) R (W) R (R) O (W) R (R) R (R) R (R) R (R) R (R) R (R) "AUT" 1 O (W) R (R) 14 Read Property Read Property Multiple Write Property Device Comm. Control Reinitialize Device Unconfirmed COV Who-Is Who-Has R (R) R (R) Device Analog Input EE212D: Device Object AI0 (Temperature) AI1 (Relative Humidity) AI2 (Water Vap. Press.) AI3 (Dew Point Temp.) AI4 (Absolute Humidity) AI5 (Mixing Ratio) AI6 (Enthalpy) AI7 (Frost Point Temp.) AI8 (Wet Bulb Temp.) R (R) R (R) System Status, Vendor Name, Vendor Identifier, Model Name, Firmware Revision, Application Software Version, Location, Description, Protocol Version, Protocol Revision, Protocol Services Supported, Protocol Object Types Supported, R (R) Object List, Max APDU Length Accepted, APDU Timeout, Segmentation Supported, Number of APDU Retries, Device Address Binding, Database Revision, Max Info Frames, Max Master, 512 (proprietary prop.: Comm. Settings) 480 R (R) NO_SEGMENTATION R (R) 3000 3 NULL 0 1 127 "38400-8n1" R (R) R (R) R (R) R (W) O (R) O (W) P (W) Persistence Non Volatile Non Volatile Fixed Non Volatile Volatile Fixed Fixed Fixed Fixed Fixed Non Volatile Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Non Volatile Fixed Non Volatile Non Volatile Max Master Property: The maximum "Max Master" value is 127. This value is writable via BACnet write property. Communication Parameter: For changing the RS485 communication parameters it is relevant to observe the character string format. The character string consists of following parts: 1. Baud rate (9600, 19200, 38400, 57600, 76800, 115200) 2. "-" 3. Number of data bits (8) 4. Parity (none) 5. Number of stop bits (1) Example: · Change parameters to: Baud = 76800, 8 data bits, no parity, 1 stop bit: String: "76800-8n1" ATTENTION: The character string shall end with the terminating 0. 12.2 Analog Input Objects All analog input object have the same structure: Property Object Identifier Object Name Description Object Type Present Value Status Flags Event State Out of Service Units Reliability COV Increment Data Type BACnetObjectIdentifier CharacterString CharacterString BACnetObjectType (Enum.) Real BACnetStatusFlags (Bit-String) BACnetEventState Boolean BACnetEngineeringUnits (Enum.) BACnetReliability (Enum.) Real Initial Value 0 ... Temperature 1 ... Relative Humidity 2 ... Water Vap. Press. 3 ... Dew Point Temp. 4 ... Absolute Humidity 5 ... Mixing Ratio 6 ... Enthalpy 7 ... Frost Point Temp. 8 ... Wet Bulb Temp. "T" ... Temperature "RH"... Rel. Humidity "e" ... Wat. Vap. Press. "Td" ... Dew Pnt. Temp. "dv" ... Abs. Humidity "r" ... Mixing Ratio "h" ... Enthalpy "Tf" ... Frost Pnt. Temp. "Tw" ... Wet Bulb Temp. (see below) OBJECT_ANALOG_INPUT 0.0 false, false, false, false NORMAL false (see below) NO_FAULT_DETECTED Not a Number (NaN) Property List BACnetARRAY[N] of BACnetPropertyIdentifier a.) When "Out of Service" flag is true, value is writable. R/O/P R Persistence Fixed R Fixed O R R (W)a.) R R R (W) R (W) R (W)a.) O (W) R (R) Fixed Fixed Volatile Volatile Volatile Volatile Non Volatile Volatile Non Volatile Fixed R (R) ............. Required Property (Readable) R (W) ............ Required Property (Read-/Writable) O (R) ............. Optional Property (Readable) O (W) ............ Optional Property (Read-/Writeable) P (R) ............. Proprietary Property (Readable) P (W)............. Proprietary Property (Read-/Writeable) Description Property: The following table lists the possible object descriptions depending on the selected measurement units: Initial Value "Temperature [deg. C]" "Relative humidity [%rH]" "Water vapor partial pressure [mbar]" "Dew point temperature [deg. C]" "Absolute humidity [g/m3]" "Mixing ratio [g/kg]" "Enthalpy [kJ/kg]" "Frost point temperature [deg. C]" "Wet bulb temperature [deg. C]" Alternative 1 "Temperature [deg. F]" "Water vapor partial pressure [psi]" "Temperature [deg. F]" "Absolute humidity [g/ft3]" "Mixing ratio [gr/lb]" "Enthalpy [ft lbf/lb]" "Temperature [deg. F]" "Wet bulb temperature [deg. F]" Alternative 2 "Temperature [deg. K]" "Temperature [deg. K]" "Enthalpy [BTU/lb]" "Temperature [deg. K]" "Wet bulb temperature [deg. K]" 6 Present Value Property: This property represents the actual measured value or actual calculated value. When the "Out of Service" flag is true, the Present Value Property is writable. The default Present Value Property is 50.0 when "Out of Service" is true. Status Flags Property: The following table describes the possible states of the "Status Flags" property: Flag IN_ALARM FAULT OVERRIDDEN OUT_OF_SERVICE State false true false true false false true Reason Value of "Event State" property is NORMAL (0) Value of "Event State" property is not NORMAL (0) Value of "Reliability" property is NO_FAULT_DETECTED Value of "Reliability" property is not NO_FAULT_DETECTED Always false "Present Value" and "Reliability" properties are not writeable via BACnet "Present Value" and "Reliability" properties are writeable via BACnet Event State Property: The following table describes the possible states of the "Event State" property: State NORMAL (0) FAULT (1) Reason Value of "Reliability" property is NO_FAULT_DETECTED Value of "Reliability" property is not NO_FAULT_DETECTED Units Property: The following table lists the possible units for each analog input object: Initial Value Degrees Celsius (62) Relative Humidity (29) Millibars (134) Degrees Celsius (62) Grams per Cubic Meter (217) Grams per Kilogram (210) Kilojoules per Kilogram Dry Air (149) Degrees Celsius (62) Degrees Celsius (62) a.) Not an ASHRAE defined unit. Alternative 1 Degrees Fahrenheit (64) Pounds Force per Square Inch (56) Degrees Fahrenheit (64) Grains per Cubic Foot (256)a.) Grains per Pound (257)a.) Footpound per Pound Dry Air (258)a.) Degrees Fahrenheit (64) Degrees Fahrenheit (64) Alternative 2 Degrees Kelvin (63) Degrees Kelvin (63) BTU per Pound Dry Air (24) Degrees Kelvin (63) Degrees Kelvin (63) Reliability Property: The following table describes the possible states of the "Reliability" property: State NO_FAULT_DETECTED (0) Reason No fault detected NO SENSOR (1) Sensor is damaged or not connected COV Increment Property: Default value is NaN (not a number). When the "COV Increment Property" is NaN or greater than 1000,000,000.0 then COV reporting is disabled. 13. MISCELLANEOUS INFORMATION Reinitialize Device (RD): The RD function is used to restart/ reboot the entire transmitter via BACnet. To use reinitialize device functionality a password is needed. The password is: "BACnet123". Device Communication Control (DCC): The DCC functionality is used to stop initiating messages on the BACnet network. After receiving a DCC stop initiate message, the device does not respond to a request any more, except to RD or DCC requests. The use of the device communication control functionality is password protected. The password is: "BACnet123". Unsolicited COV Reporting: When COV reporting is activated, a BACnet message is broadcasted every time when the difference between actual "Present Value" and the previous measured "Present Value" since last COV message exceeds the "COV Increment" value. Since no subscription list is supported, the COV message is always broadcasted. This function is useful for many BACnet clients which need the same information of one BACnet device (e.g. outdoor temperature). 7 HEADQUARTERS E+E Elektronik Ges.m.b.H. Langwiesen 7 4209 Engerwitzdorf Austria Tel.: +43 7235 605-0 E-mail: info@epluse.com Web: www.epluse.com SUBSIDIARIES E+E Elektronik China 18F, Kaidi Financial Building, No.1088 XiangYin Road 200433 Shanghai Tel.: +86 21 6117 6129 E-mail: info@epluse.cn E+E Elektronik France 47 Avenue de l`Europe 92310 Sèvres Tel.: +33 4 74 72 35 82 E-mail: info@epluse.fr E+E Elektronik Germany Obere Zeil 2 61440 Oberursel Tel.: +49 6171 69411-0 E-mail: info@epluse.de E+E Elektronik India 801, Sakhi Vihar Road 400072 Mumbai Tel.: +91 990 440 5400 E-mail: info.in@epluse.com E+E Elektronik Italy Via Alghero 17/19 20128 Milano (MI) Tel.: +39 02 2707 86 36 E-mail: info@epluse.it E+E Elektronik Korea Suite 2001, Heungdeok IT Valley Towerdong, 13, Heungdeok 1-ro, Giheung-gu 16954 Yongin-si, Gyeonggi-do Tel.: +82 31 732 6050 E-mail: info@epluse.co.kr E+E Elektronik USA 333 East State Parkway Schaumburg, IL 60173 Tel.: +1 847 490 0520 E-mail: office@epluse.comAdobe PDF Library 16.0.7 Adobe InDesign 17.4 (Windows)