DENBIG PORTABLE AIR CONDITIONER
Instruction Manual
Model #: A019G-05KR
Content
Please keep this manual for later review and read it carefully before use.
I. Notes
The air conditioning is only suitable for indoor use and is not suitable for other applications.
Follow local grid interconnection rules while installing the air conditioning and ensure that it is properly grounded. If you have any question on electrical installation, follow the instructions of the manufacturer, and if necessary, ask a professional electrician to install it.
Place the machine in a flat and dry place and keep a distance of above 50cm between the machine and the surrounding objects or walls.
After the air conditioning is installed, ensure that the power plug is intact and firmly plugged into the power outlet, and place the power cord orderly to prevent someone from being tripped or pulling out the plug.
Do not put any object into the air inlet and outlet of the air conditioning. Keep the air inlet and outlet free from obstructions.
When drainage pipes are installed, ensure that the drainage pipes are properly connected and are not distorted or bended.
While adjusting the upper and lower wind-guide strips of the air outlet, pluck it with hands gently to avoid damaging wind-guide strips.
When moving the machine, make sure that it is in an upright position.
The machine should stay away from gasoline, flammable gas, stoves, and other heat sources.
Do not disassemble, overhaul, or modify the machine arbitrarily, otherwise it will cause a machine malfunction or even bring harm to persons and properties. To avoid danger, if a machine failure occurs, ask the manufacturer or professionals to repair it.
Do not install and use the air conditioning in the bathroom or other humid environments.
Do not pull the plug to turn off the machine.
Do not place cups or other objects on the body to prevent water or other liquids from spilling into the air conditioning.
Do not use insecticide sprays or other flammable substances near the air conditioning.
Do not wipe or wash the air conditioning with chemical solvents such as gasoline and alcohol. When you need to clean the air conditioning, you must disconnect the power supply and clean it with a half-wet soft cloth. If the machine is really dirty, scrub with a mild detergent.
The appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and maintenance shall not be made by children without supervision.
II. Features and Components
1. Features
New look, compact structure, streamlined machine, aristocratic atmosphere.
With cooling, heating (single cold without heating function), dehumidification, and fan functions. Continuously Water Drainage Functions.
Automatic swing leaf in the outlet has automatic air swing function, and the outlet can be covered when the machine is turned off to prevent dust from entering the body.
LCD displays the control panel. The machine is beautiful and elegant. A high-quality LCD remote control is equipped to facilitate operation. The remote control can be placed on the back of the body. It adopts a user-friendly remote control storage design.
Handles on both sides adopt a dividing point design, making it easier to carry, and the body design is more humane.
The structure of wrapping the power cord on the back facilitates users to hang the power cord without it hanging down to the ground, preventing staining and damage.
Outdoor interface is set high to facilitate assembly and keep the smooth flow of the heat pipe.
Air filtration capability.
Timing switch function.
Protection function of automatically restarting the compressor after three minutes, with a variety of other protection functions.
2. Components
A line drawing of the DENBIG portable air conditioner unit, showing its tall, rectangular form with vents on the front and controls on the top.
Diagram showing the components of the portable air conditioner unit: Top Cover, Control Panel, Air Outlet/Louver, Handle, Rear Housing, Caster, Front Housing.
Diagram showing the rear view of the unit: Front Housing, EVA Filter, Continuous Drainage Hole, Handle, Air Vent, CON Filter, Drainage Hole, Rear Housing.
Diagram showing the Exhaust Pipe Assembly and Window Sealing Plate Assembly.
III. Control Setting
1. Control Panel Operation Instructions
1) Operation Interface:
Diagram of the control panel with numbered buttons: 1. Power Button, 2. Sleep Button, 3. Mode Selection Button (Fan), 4. Down Button, 5. Up Button, 6. Fan Speed Selection Button, 7. Timer Button, 8. Auto Swing (Optional), 9. Display Window.
1. Power Button: Pressing the button turns the unit on and off.
2. Sleep Mode: In Cooling Mode, pressing the sleep button turns on sleep mode, and the unit will work in Energy-Saving and quiet mode.
3. Mode Selection Button: When the unit is powered on, press this button to switch between Cooling → Fan → Dry mode.
4. DOWN: Pressing this button decreases the temperature setting or sets down the timer to the required timer setting. This function is not available under FAN mode and DEHUMIDIFYING mode.
5. UP: Pressing this button increases the temperature setting or sets up the timer to the required timer setting. This function is not available under FAN mode and DEHUMIDIFYING mode.
6. Wind Speed Selection Button:
- 1) In Cooling mode and Fan mode, pressing the button selects high or low wind speed operation.
- 2) In Dehumidifying mode, pressing the button is unavailable.
7. TIMER: Pressing the TIMER button sets the unit to automatically turn ON or OFF. Use the + and - buttons to program the hour increment.
2. Operation Instructions of Remote Control
1) The remote controller is as follows:
Diagram of the remote control with numbered buttons: 1. Power, 2. Timer, 3. Down, 4. Mode, 5. Up, 6. Fan, 7. Sleep Mode.
- 1. Power: Press the [Power] button to turn on or turn off the machine.
- 2. Timer: Press the [Timer] button to set the timing value.
- 3. Down: Press the [Down] button to reduce temperature and timing set value.
- 4. Mode: Press the [Mode] button to switch between cooling, air supply, and dehumidification mode.
- 5. Up: Press the [Up] button to increase temperature and timing set value.
- 6. Fan: Press the [Fan] button to select high or low wind speed.
- 7. Sleep Mode: Press the [Sleep Mode] button to turn on the sleep mode.
*NOTE: AAA 1.5VDC battery (not included).
IV. Protection Function
4.1 Frost Protection Function:
In cooling, dehumidification, or economic power saving mode, if the temperature of the exhaust pipe is too low, the machine will automatically enter protection status. If the temperature of the exhaust pipe rises to a certain temperature, it can automatically revert to normal operation.
4.2 Overflow Protection Function:
When water in the water pan exceeds the warning level, the machine will automatically sound an alarm, and the LCD temperature display area will show "FL". At this point, you need to move the drainage pipe connecting the machine or the water outlet to a sewer or other drainage area to empty the water (details see Drainage Instructions at the end of this chapter). After the water is emptied, the machine will automatically return to the original state.
4.3 Automatic Defrosting (heating and cooling models have this function):
The machine has an automatic defrosting function. During defrosting, the heating symbol on the display screen will flash.
4.4 Automatic Thermal Protection:
To protect the service life of the machine, it has automatic thermal protection in heating mode. During the protection period, the compressor and the lower motor will stop operation and will automatically return to normal heating state after the temperature of the machine recovers.
4.5 Protection Function of the Compressor:
To increase the service life of the compressor, it has a 3-minute delay booting protection function after the compressor is turned off.
V. Installation and Adjustment
1. Installation
Warning: Before using the mobile air conditioning, keep it upright for at least two hours. The air conditioning can be easily moved in the room. During the moving process, ensure that the air conditioning is in the upright position and should be placed on a flat surface. Do not install and use the air conditioning in the bathroom or other humid environments.
1.1 Install the Heat Pipe Assembly (as shown in Fig. 1)
Figure 1: Diagram showing how to attach the exhaust pipe to the back of the unit. An arrow indicates pushing the heat pipe assembly into the back panel vent slot.
- Take out the outer connector assembly and the exhaust pipe assembly, and remove the plastic bags.
- Insert the heat pipe assembly (the end of the exhaust joint) into the back panel vent slot (push to the left) and complete the assembly (as shown in figure 1).
1.2 Installation of Window Sealing Plate Components
Figure 2 & 3: Diagrams illustrating the installation of the window sealing plate assembly in a window, showing horizontal and vertical placement options.
- Half open the window and mount the window sealing plate assembly to the window (as shown in Fig. 2 and Fig. 3). Components can be placed in horizontal and vertical direction.
- Pull various components of the window sealing plate assembly open, adjust their opening distance to bring both ends of the assembly into contact with the window frame, and fix various components of the assembly.
Notes:
- 1. The flat end of the exhaust pipe joints must be snapped into place.
- 2. The pipe cannot be distorted nor have substantial turning (greater than 45°). Keep the ventilation of the exhaust pipe not blocked.
1.3 Install the Unit
Figure 4: Diagram showing the placement of the portable air conditioner unit near a window, indicating a minimum clearance of 50 cm from walls and objects.
- Move the machine with the installed heat pipe and fittings before the window, and the distance between the body and walls or other objects shall be at least 50 cm (as shown in Fig. 4).
Figure 5 & 6: Diagrams showing the exhaust pipe connected from the unit to the window sealing plate assembly in the window.
Elongate the exhaust pipe and snap the flat end of the exhaust pipe joints into the hole of the window sealing plate assembly (as shown in Fig. 5 and Fig. 6).
Notes:
- 1. The flat end of the exhaust pipe joints must be snapped into place.
- 2. The pipe cannot be distorted nor has substantial turning (greater than 45°). Keep the ventilation of the exhaust pipe not blocked.
VI. Drainage Instructions
1. Manual Drainage:
- When the machine stops after the water is full, turn off the machine power and unplug the power plug.
- Place the water container below the side water outlet behind the body.
- Unscrew the rotary knob and unplug the rubber stopper; the water will automatically flow into the water container.
- When the water is discharged, insert the rubber stopper and tighten the rotary knob.
Notes:
- Please move the machine carefully so as not to spill the water in the water pan at the bottom of the body.
- Keep the rotary knob and rubber stopper properly.
- During drainage, the body can be tilted slightly backwards.
- If the water container cannot hold all the water, before the water container is full, stuff the water outlet with the rubber stopper as soon as possible to prevent water from flowing to the floor or the carpet.
- Restart the machine after the rubber stopper and rotary knob are installed; otherwise, condensate water of the machine will flow to the floor or the carpet.
Diagram illustrating manual drainage, showing the unit tilted slightly backward with a water container placed below the side water outlet behind the body.
2. Continuous Drainage (only applicable to cooling and dehumidification mode):
Diagram illustrating continuous drainage, showing the drainage pipe connected to the unit's water outlet and directed into a bucket.
- Unscrew the rotary knob and unplug the rubber stopper.
- Set the drainage pipe into the water outlet.
- Connect the drainage pipe to the bucket.
VII. Maintenance
Cleaning: Before cleaning and maintenance, turn off the machine and unplug the plug.
1. Clean the Surface
Clean the surface of the machine with a wet soft cloth. Do not use chemicals, such as benzene, alcohol, gasoline, etc.; otherwise, the surface of the air conditioning will be damaged or even the whole machine will be damaged.
2. Clean the Filter Screen
If the filter screen is clogged with dust, and the effectiveness of the air conditioning is reduced, be sure to clean the filter screen once every two weeks.
3. Clean the Upper Filter Screen Frame
- Unscrew one screw fixed by the EVA filter net and back shell with a screwdriver, and take out the EVA filter net.
- Put the EVA filter screen into warm water with neutral detergent (about 40°C / 104°F) and dry it in the shade after rinsing clean.
Diagram showing the unit with an arrow pointing to the filter screen, and a separate image of the filter screen itself.
VIII. Troubleshooting
Do not repair or disassemble the air conditioning by yourself. Unqualified repair will lead to failure of the warranty card and may cause damage to users or their properties.
Problems | Reasons | Solutions |
---|---|---|
The air conditioning does not work. | There is no electricity. The overflow indicator displays "FL". The ambient temperature is too low or too high. |
Turn it on after connecting it to a socket with electricity. Discharge the water inside. Recommend to use the machine in at the temperature of 7-35 °C (44-95 °F). |
The cooling or heating effect is not good. | In cooling mode, the room temperature is lower than the set temperature; in heating mode, the room temperature is higher than the set temperature. In dehumidification mode, the ambient temperature is low. There is direct sunlight. Doors or windows are open; there are a lot of people; or in cooling mode, there are other sources of heat. The filter screen is dirty. The air inlet or outlet is blocked. |
Change the set temperature. The machine is placed in a room with an ambient temperature of greater than 17 °C (62 °F). Pull the Curtain. Close doors and windows, and add new air conditioning. Clean or replace the filter screen. Clear obstructions. |
Big Noise compressor does not work. | The air conditioning is not placed on a flat surface. Overheat protection starts. |
Put the air conditioning on a flat and hard place (to reduce noise). Wait for 3 minutes until the temperature is lowered, and then restart the machine. |
The remote control does not work. | The distance between the machine and the remote control is too far. The remote control is not aligned with the direction of the remote control receiver. Batteries are dead. |
Let the remote control get close to the air conditioning, and make sure that the remote control directly faces to the direction of the remote control receiver. Replace batteries. |
Displays 'E1'. | The room temperature sensor is abnormal. | Check the room temperature sensor and related circuitry. |
Displays 'E2'. | The pipe temperature sensor is abnormal. | Check the pipe temperature sensor and related circuitry. |
If problems not listed in the table occur or recommended solutions do not work, please contact the professional service organization or contact onlinesales@jhs8.com.