AONCIA Ceiling Fan with Light
Instruction Manual
Model: AC-CFL1008
Thank you for your purchase. Please read the "Safety Precautions" before use, use the product correctly, and keep this manual for future reference.
Email: support@aoncia.jp
Safety Precautions
This document contains safety-related information to prevent injury and damage. Please understand and follow the instructions.
WARNING: Improper handling may result in death or serious injury.
Prohibit
- This light fixture is for ceiling mounting only. Incorrect installation may cause fire, electric shock, or injury.
- If you notice any abnormality, turn off the power, ensure it has stopped, and contact your seller.
- Do not forcibly install on incompatible wiring devices, as this may cause fire, electric shock, or injury. Incompatible wiring devices include those with exposed power terminals, damaged wiring, or wobbling due to inadequate fastening.
- Do not use if the socket is damaged or the plug is loose, as this may cause electric shock, short circuit, or fire.
- Do not install in unreinforced locations (plywood board or plasterboard), sloped locations, or on wall surfaces.
- Keep out of reach of infants to prevent injury or electric shock.
- Do not use audio or video equipment nearby as it may cause noise. If used, keep it as far away as possible.
- Do not allow metal or foreign objects to enter the main unit, as this may cause electric shock or malfunction.
- Do not damage, bend, pull, or twist the power cord, as this may cause electric shock, short circuit, or fire.
- Do not place hot items directly under the main unit.
- Do not cover the main unit with cloth, paper, or other flammable materials.
- Do not touch the main unit when the light is on or immediately after it goes out, as you may get burned.
- Do not touch the light source (transparent power strip), as this may cause malfunction.
- This device is not waterproof; do not use it in wet places like bathrooms or outdoors, as this may cause fire or electric shock.
- People with reduced mental capacity and infants should not use the product.
- If any abnormality is detected, turn off the power immediately and contact the manufacturer or a qualified service technician.
- When replacing parts, consult a qualified installer.
Must be observed
- Use at 100~240V AC. Excessive voltage may cause overheating, fire, or electric shock.
- Do not modify or replace equipment parts, as this may result in fire, electric shock, or injury.
- Luminaires have a lifespan. After two years, inspect or replace the unit, even if it appears to be in good condition. Continued use without inspection may result in fire, electric shock, smoking, or falling. High ambient temperature and long lighting times shorten the product's life.
Attention: Incorrect handling may result in injury or property damage.
Product Overview
Main unit (Do not disassemble)
- Ceiling Cover
- Illumination Part (Light Guide Plate)
- Wing
- Front Guard
Accessories:
- 2.4G Remote Control (Battery Included)
- Remote Control Holder
- Instruction Manual
How to install
Checking the Installation Environment
WARNING: Always turn off the wall switch when installing, removing, or cleaning wiring devices.
How to use Remote Control
Remote Control (upper half)
- Night Light Button: Turn on only the nightlight. Each press toggles between light and dark.
- Favorite Button: Record and reproduce your favorite lighting conditions.
- Relax Button: Adjust the light to warm colors.
- LED Power Button: Turn on/off the LED.
- OFF Button: Turn off/stop LED and fan simultaneously.
- All Lights Button: Turn on all LED lights except the night light.
- LED Timer Button: Set automatic light off (sleep timer).
- Refreshing Button: Adjust the light to a refreshing daylight color.
- Dimmer Button: Adjust brightness.
LED lights on/off
- Turn on the power (wall switch, etc.) and press the All Lights Button on the remote control. If connected correctly, the light will turn on at 100% dimming. If the light does not come on, check the following:
- Connecting wiring device to a hook ceiling.
- Visually check the connection between the hook ceiling and the wiring device for any problems before turning on the power.
- Press the Dimmer/Refreshing/Relax Button to adjust brightness and color. Each press of the Dimmer Button adjusts brightness by 10 levels. Use the Refreshing Button for daylight color and the Relax Button for warm color (10 levels each).
- To store favorite dimmer/color settings, press and hold the Favorite Button. The LED will flash once to confirm memorization.
- To turn on the night light, press the Night Light Button. Pressing it again cycles through high and low levels.
- Set a sleep timer: Press the LED Timer Button once for a 30-minute auto-off, twice for a 60-minute auto-off. Press again to cancel. A longer sound indicates timer cancellation.
Sleep Timer Sound
Sound Image | Beep | Beep x2 | Beep x3 | Beep x4 | P | Cancel |
Off Timer | Approx.1h | Approx.2h | Approx.4h | Approx.8h | cancel |
LED lights on/off
- Turn the light off/on with the remote control using the LED Power Button. This controls only the LED, not the fan.
- Turn off the light with the OFF Button on the remote control or the wall switch. The LED and fan stop simultaneously. To power off only one, use the LED Power Button or Fan Power Button.
- Memory Function:
- Wall Switch Memory: When turning on/off via the wall switch, the light returns to its last state. However, night light and off settings are not memorized; all lights turn on.
- Remote Control Memory: The light turns on in the last state it was turned off using the power button. Night light is not memorized.
How to use fan part
Remote Control (bottom half)
- Fan Power Button: Run/stop the fan.
- Swing Angle Button: Change the wind direction angle in 1 level increments.
- Fan Timer Button: Set the fan off timer.
- Rhythm Wind Button: Activate natural wind by adjusting airflow rate.
- Wind Direction Switch Button: Switch between upward and downward wind direction.
- Air Volume Adjustment Button (1-8): Set airflow in 8 levels.
- Swing Rotation Button: Rotate the fan part 360 degrees to set airflow direction.
- Remote Control CH Setting Button: Set the remote control channel.
Start/stop operation
- Starting operation: Press the Fan Power Button on the remote control. The fan starts at the last used airflow level (memory function). For the first use or after power interruption via wall switch, it starts with low airflow. If the fan was turned off via the wall switch, it will not start automatically when power is restored; use the wall switch to start it.
- Run the fan with a wall switch: Press and hold the Air Volume Adjustment Button "3" to set fan memory. A beep confirms the setting. Press and hold again to cancel.
- Adjust the air volume: Use the Air Volume Adjustment Button "7". "1" is the weakest, and "8" is the strongest airflow.
- Activating the Rhythm Wind Function: Press the Rhythm Wind Button once to activate; press twice to deactivate and return to normal wind. Airflow can be adjusted (100%→30%→100%).
- Set the off timer: Press the Fan Timer Button repeatedly to set the timer. A tone indicates the set time.
Off Timer Setting
Sound Image | Beep | Beep x2 | Beep x3 | Beep x4 | P | Cancel |
Off Timer | Approx.1h | Approx.2h | Approx.4h | Approx.8h | cancel |
To cancel the off timer, press the fan timer button until it beeps.
- Press the Fan Power Button on the remote control to stop operation. The fan automatically stops after approximately 12 hours of inactivity to prevent forgetting to turn it off.
- Remote Control Channel Setting: Within 10 seconds of turning on the power, press the Remote Control CH Setting Button. The LED will blink twice to confirm channel setting. The 2.4G remote control cannot support multiple fixtures.
How to use fan part
Change vertical wind direction
- Downward wind: Directs wind downwards to lower perceived temperature.
- Upward wind: Directs wind towards the ceiling to circulate warm air from high places downwards.
Note: Blades stop briefly when switching wind direction.
Start/stop swing operation
Combine swing angle and rotation to direct wind to a specific point or cover a larger area.
- Angling the airflow direction with the Swing Angle Button: Pressing the Swing Angle Button cycles the angle from 15 degrees to 0 degrees. Some operating noise may occur during angle setting, but this is not a malfunction.
- Rotate the fan part while angling with the Swing Rotation Button: Rotate the fan to the desired airflow position and stop. Rotation can be continuous. This allows airflow directly under the light or to a wider area. If the swing angle is not set, the wind blows straight down. Some noise may occur during rotation, but this is not a malfunction.
Swing Angle Memory: If the wall switch is turned off while the fan is rotating, the state is memorized. When power is restored and the fan is started with the remote, it resumes its previous state.
Care & Maintenance
WARNING
- When cleaning, turn off the wall switch and disconnect wiring devices to prevent electric shock, fire, or injury.
- Never use household detergent, thinner, benzene, alcohol, or polish.
- Do not wash the main unit by pouring water on it, as this may cause electric shock or malfunction.
Normal care
Remove dust from the front guard with a vacuum cleaner with a crevice nozzle.
Cleaning
To remove dirt from the main unit, soak a soft, wrung-out cloth in lukewarm water or neutral dish detergent (excluding citrus-based detergents), wipe the unit, and then dry with a dry cloth. Do not rub the resin part too hard. Only the front guard and ceiling cover can be washed entirely.
How to disconnect from the wiring device
- Ensure the wall switch is off.
- Loosen the screws and lower the ceiling cover.
- Press the release button on the ceiling hook and turn the main unit counterclockwise to remove it from the wiring device. Be careful not to apply excessive force, which could damage the hook ceiling part. The direction of turning is seen from the front guard side.
ATTENTION: Use an appropriate stepladder and have at least two people to remove the product to prevent falls. Be careful not to turn the unit too much during removal to avoid damage or malfunction. The cover for the LED light part cannot be removed.
Care & Maintenance
How to remove the front guard
ATTENTION: Be careful not to injure yourself on the edges of the blades. When removing or installing the front guard, hold the rear guard to prevent rotation. To clean the front guard and blades, remove the front guard.
- While holding the rear guard, turn the front guard counterclockwise.
- Pull the front guard towards you to remove it. The blades cannot be removed.
How to install the front guard
WARNING: Do not use without the front guard installed, as it may cause accidents or malfunctions.
- Align the protrusions on the rear guard with the recesses on the front guard.
- Hold the rear guard and turn the front guard clockwise to secure it.
Regular maintenance
Warning: Turn off the wall switch and remove the main unit before cleaning. The blades should be cleaned regularly. Dust on the blades can reduce airflow. Cleaning may improve performance even if no visible dust is present.
How to store
If not using the remote control for over 3 months, remove the batteries. If storing the main unit, clean it, dry it thoroughly, and store it in a dry place, like a plastic bag, to prevent dust accumulation.
Specification
Specifications are subject to change without notice.
Product Name | Ceiling fan with light | Operating Temperature | -20~45℃ |
Model Number | AC-CFL1008 | Brightness (Lumen) | 4160lm |
Fixed Voltage | 100V~240V | Light Color | 2700~6500K |
Rated Frequency | 50/60Hz | Size | Φ400mm*185mm |
Rated Power | light: 40W fan: 12 | Weight | 1.5kg |
FAQ
If the product is not working properly, refer to the following. If any abnormality persists, turn off the wall switch and contact the seller or customer service center.
WARNING: Only a repair technician should disassemble or repair the product.
Symptoms | Main Causes | Treatment |
LED part Light is not on |
Power (wall switch, etc.) is turned off | Turn on the power (wall switch, etc.) |
The breaker is turned off | Turn on the breaker | |
The hook ceiling and wiring device are not connected securely. | Securely connect hook ceiling and wiring device | |
There is an abnormal noise while the light is on/off | Some noise may be generated from the power supply unit depending on the usage environment. | No problem |
Fan part The wings don't turn |
Power (wall switch, etc.) is turned off | Turn on the power (wall switch, etc.) |
The breaker is turned off | Turn on the breaker | |
The hook ceiling and wiring device are not connected securely. | Securely connect hook ceiling and wiring device | |
The function to prevent forgetting to turn off the power is working. | Press the fan power button on the remote control to start operation. | |
Stopped suddenly | Timer button pressed. | Press the fan power button on to start operation. |
There's a strange noise | Front guard not installed properly | Install the front guard correctly |
Not operate with wall switch | Incorrectly attached to the ceiling | Re-check the installation on the ceiling |
No problem (fan not set to run on wall switch) | Set the fan to run with a wall switch (Refer to "Running the fan with a wall switch" on page 7) | |
Common area Remote control does not work properly |
Remote control batteries are not installed correctly | Reinsert the batteries in the remote control correctly |
The batteries in the remote control are dead | New batteries for the remote control | |
The channels on the main unit and remote control do not match | Match the channel settings on the main unit and remote control |
About LED
Due to variations in LEDs, individual LEDs or fixtures with the same model name may differ in emission color and brightness. The LED light source cannot be replaced. Please contact your store for repair.
About the lifespan of lighting fixtures
The Japan Lighting Fixtures Manufacturers Association recommends replacing general lighting fixtures every 2 years. For optimal usage, early inspection and replacement are recommended. Optimal usage conditions are ambient temperature below 30°C, 10 hours of use per day, and 2 years of use.
Customer Service
Register for your 12-month warranty for free via the following methods:
More instructions
Scan the QR code to access installation and usage videos.
YouTube ID: Aoncia
Link: https://www.youtube.com/channel/UCex5JQ6Yq866_fE4LX8zT3g
Share
For ideas and suggestions, please contact us.
Facebook ID: Aoncia
Link: https://www.facebook.com/AonciaGlbal
After-sales
For product questions, please contact us.
Email: support@aoncia.jp (Except Saturdays, Sundays, holidays, and New Year holidays)
Get benefits from your warranty
- 30 days no reason refund
- 12-month warranty for quality issues
- Free user technical support
- New item promotions
- Give out good gifts from time to time
FCC Compliance
FCC Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications not explicitly approved by the manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0cm between the radiator and your body.