Instruction Manual for Anolis models including: CALUMMA XS SC and MC, CALUMMA XS SC, CALUMMA XS MC, CALUMMA XS, CALUMMA

INSTALLATION INSTRUCTIONS CALUMMA XS SC AND MC

PDF preview unavailable. Download the PDF instead.

Installation Instructions Calumma XS v4 March 2023
INSTALLATION INSTRUCTIONS CALUMMA XS SC AND MC

QR code for Installations Instructions

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com

VERSION 4.0 / 3_2023

1

INSTALLATION INSTRUCTIONS CALUMMA XS SC AND MC

Fixture must be installed by a qualified electrican in accordance with all national and local electrical and construction codes and regulations. This device falls under class one and must be grounded!

STEP 1 CALUMMA INSTALLATION USING YOKE

1

2

Use fasteners that are appropriate for

use with your mounting surface

Drill the holes two into the surface according the given dimensions. 3

Fasten the Yoke of the fixture to the surface by two washers, spring washers and screws.

Use an Allen key to release tilting lock on each side of luminaire and adjust tilt of LED module in range of +180°/-180°.
STEP 2 CABLE GLAND INSTALLATION
Slip the cable through the gland according to the picture below and do not assemble the gland yet.
Use wrench size 22 for cable gland M20x1.5 Use wrench size 16 for cable gland M12x1.5
Install Cable glands individually!

Strip these lengths for cable connections.

Power Connection Data Connection

A
9mm 9mm

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com

VERSION 4.0 / 3_2023

2

INSTALLATION INSTRUCTIONS CALUMMA XS SC AND MC
STEP 3 CALUMMA CONNECTION (JUNCTION BOX IS NOT PART OF THE PACKAGE)

4x Calumma XS Power

next Junction Box

WIRE Red Black Green/Yellow

Connection ­ colour coding

POWER CONNECTION
Vcc

WIRE Orange

0V

White

/

/

DATA CONNECTION
Data + (+)
Data - (-)
Data 0V (0)

1x Calumma XS

Power

next Junction Box

Junction Box
STEP 4 CABLE GLAND INSTALLATION
Assemble the cable gland according to the picture.
Use wrench size 22 for cable gland M20x1.5 Use wrench size 16 for cable gland M12x1.5
Install Cable glands individually!
We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting in into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body.
Failure to properly install cable glands will result in failure of the water tight seal!

Junction Box

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com

VERSION 4.0 / 3_2023

3

INSTALLATION INSTRUCTIONS CALUMMA XS SC AND MC
STEP 5 INSTALLATION OF ACCESSORIES
HALF TOPHAT

TOPHAT

OPTICAL DEMO SET

1

2

Screw-out 2 screws from the cover plate. 3

Remove the cover plate. 4

Place the accessories (TOPHAT, HALF TOPHAT, OPTICAL DEMO SET) onto luminaire and centre it.

Fasten the accessories (TOPHAT, HALF TOPHAT, OPTICAL DEMO SET) to the luminaire by the 2 packed-in washers and screws.

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com

VERSION 4.0 / 3_2023

4

INSTALLATION INSTRUCTIONS CALUMMA XS SC AND MC
5 Only for OPTICAL DEMO SET
Slide the Optical foil into the space of Optical Demo Set. TWIN WALL COVER

1

Use fasteners that are appropriate for

2

use with your mounting surface

CABLE OPENNING

Prepare openings for cables in the mounting surface and two mounting holes according to the dimensions. Screw the lower part on the surface with two screws.

Place the luminaries on the four screws on the lower part.

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com

VERSION 4.0 / 3_2023

5

INSTALLATION INSTRUCTIONS CALUMMA XS SC AND MC

3

4

Fasten the luminaires with four nut and washers 5

Insert the cover plate on the lower part.

Screw the cover plate with the lower part with four screws.

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com

VERSION 4.0 / 3_2023

6


Adobe PDF Library 17.0 Adobe InDesign 18.1 (Windows)