User Manual for TENMARS models including: TM-380 Multi IAQ Monitor, TM-380, Multi IAQ Monitor, IAQ Monitor, Monitor
1 Micro USB cable. 3. Safety Precaution. Caution! Please refer to this manual. Improper use may damage the meter and its components.
เครื่องวัด CO2/ฝุ่น PM2.5 PM10/อุณหภูมิ/ความชื้น TENMARS TM-380
10 feb 2023 — Contents: 1 Application .................................................................. 1. 2 Accessories.
Multi IAQ Monitor TM-380 User's Manual HB2TM3800000 Contents: 1 Application .................................................................. 1 2 Accessories................................................................. 1 3 Safety Precaution........................................................ 1 4 Instrument Description ............................................... 2 4.1 Feature and function...................................... 2 4.2 Indication on the LCD display ....................... 3 5 Operation..................................................................... 4 5.1 Power on/off ................................................... 5 5.2 Auto Power Off............................................... 5 5.3 Backlight mode .............................................. 5 5.4 MAX/MIN,AVG and MAN MIN ................. 5 5.5 REC Manual record ................................ 5 5.6 LOG starts the auto-recording function 6 5.7 Read the data recorded in the memory. 6 5.8 °C or °F units .................................................. 6 5.9 Clear memory................................................. 6 5.10 Turn on / off the key sound .................... 7 5.11 Resume the factory settings.......................... 7 5.12 Function settings ........................................... 7 6 General Specifications.............................................. 12 7 General Specifications.............................................. 14 7.1 PM2.5 ............................................................ 14 7.2 PM10 ............................................................. 14 7.3 CO2................................................................ 14 7.4 Temperature ................................................. 15 7.5 Humidity ....................................................... 15 8 Maintenance or Repair .............................................. 16 9 Product disposal ....................................................... 16 TM-380 1 Application This air quality meter can measure and display CO2, PM2.5, Humidity and Temperature measurements and is ideal for monitoring indoor air quality in a variety of environments. 2 Accessories 1 Meter (with a 3.7V Rechargeable lithium battery) 1 User's Manual 1 Micro USB cable 3 Safety Precaution Caution! Please refer to this manual. Improper use may damage the meter and its components. Complies with European Directive. Do not operate in environments with flammable gas or humid environments. Operating altitude: up to 2000M. Operating environment: Indoor use; Pollution degree 2. Clean with soft cloth when dirty, such as glasses cloth. Do not clean with chemicals and other solvents. EMC: EN61326-1:CISPR 11:Group 1, Class B Class B Equipment for use in all establishments other than domestic. Group 1 RF energy generated is needed for internal functioning. 1 4 Instrument Description 4.1 Feature and function TM-380 1. LCD 2. Right-side button 3. Memory reading / Up button 4. MAX / MIN / AVG button 5. Power button 6. Single log and auto-record button/Down button 7. Temperature and humidity sensing port 8. Air outlet for sensor 9. Air inlet for sensor 10. Micro USB jack 2 4.2 Indication on the LCD display TM-380 1.MAX / MIN /AVG /MAN MIN 2.Manual recording 3.Auto-recording 4.Read record 5.Battery indicator 6.Auto-power off 7.Buzzer 8.Alarm 9.CO2 10. PM2.5 11. Temperature 12. MM minute, SS second 13. PM10 14. Humidity 3 TM-380 5 Operation Please hold the meter in the following way for the correct measured value: The placement follows the This is a suitable way to hold electrical specifications the meter, holding for a long described in Section 7. time may affect the accuracy. This is not a proper way to hold the meter, it will block the temperature and humidity sensors. This is not a proper way to hold the meter, it will block the PM2.5, PM10 and CO2 sensors. 4 TM-380 5.1 Power on/off Press to turn the power on or off. 5.2 Auto Power Off At the power-on status, press and hold for more than 2 seconds to disable or resume auto power off function. When auto power off is activated, the indicator appearing, and it will automatically turn off after 30 minutes. 5.3 Backlight mode Press "right-side button" to turn on or off the backlight. (When the red backlight for alarm is on, this button is invalid) The backlight mode is turned off automatically after 15 seconds. 5.4 MAX/MIN AVG and MAN MIN Press to enter this function, the MAX is shown on the screen and it displays the maximum value. Press repeatedly to select the function of MIN/AVG/MAX MIN/MAX and update the displayed value. When select MAX MIN function, it displays the current measured value. 5.5 REC Manual record Press to save one data log, the "REC" and the log number appear on the LCD for one second. For an example of the log number 10, it will increase by 1 when pressing every time. When reaching the maximum log number 20, appears. 5 TM-380 5.6 LOG starts the auto-recording function Press and hold for more than 2 seconds, " " appears on the LCD, and auto-recording starts. If the power is insufficient during auto-recording, appearing, auto-recording will be forcibly stopped. When reaching the maximum log number 20, appears. Press and hold again for more than 2 seconds to exit the auto-recording function. 5.7 Read the data recorded in the memory Press to enter the memory-reading mode, while and the log number appear on the LCD for one second, the record is then displayed. Read the data recorded in the memory with or . Press and hold to exit this mode. 5.8 °C or °F units At the shutdown status, press and hold , then press to turn on the meter, after the software version appears, release . Repeat the above steps to switch the unit. 5.9 Clear memory At the shutdown status, press and hold and then press to turn on the meter, the and software version appears successively on the LCD, release the the memory. to clear 6 TM-380 5.10 Turn on / off the key sound The sound is defaulted as on and the is displayed. At the shutdown status, press and hold and then press to turn on the meter, after the software version appears, release and the disappears, the key sound is off. Repeat the above step to tun on the key sound. 5.11 Resume the factory settings At the shutdown status, press and hold "right-side button" and then press , the and software version appears successively on the LCD, release the "right-side button" to complete the process of resuming to the factory settings and clearing the memory. Auto-shutdown: OFF Key sound: On The calibration value resumed to 0 CO2 Abc OFF Memory cleared 5.12 Function settings Press "right-side button" for more than 2 seconds to enter the setting mode. Press the "right-side button" repeatedly to enter the setting function 1 ~ 8 in sequence: 7 SET 1. Time interval setting 1. The LCD displays: TM-380 2. Press or to select the interval 5 seconds / 10 seconds / 5 minutes / 10 minutes / 20 minutes / 30 minutes / 60 minutes; the default value is 5 seconds. 3. Press the "right-side button" again to enter set 2. SET 2. CO2 alarm setting 1. The LCD displays: 2. Press to move the digit, and the selected digit will flash. 3. Press or to increase or decrease the CO2 value. 4. Press the "right-side button" again to enter set 3. 8 SET 3. PM2.5 alarm setting 1. The LCD displays: TM-380 2. Press to move the digit, and the selected digit will flash. 3. Press or to increase or decrease the CO2 value. 4. Press the "right-side button" again to enter set 4. SET 4. PM10 alarm setting 1. The LCD displays: 2. Press to move the digit, and the selected digit will flash. 3. Press or to increase or decrease the CO2 value. 4. Press the "right-side button" again to enter set 5. 9 TM-380 SET 5. (Factory use only) CO2 Abc self-calibration mode 1. The LCD displays: 2. This is for factory calibration use only. Please do not change it. 3. Click the "right-side button" again to enter set 6. SET 6. CO2 manual calibration 1. The LCD displays: 2. Directly increase or decrease the displayed value of CO2, press the to move the digit, and the selected digit will flash. 3. Press or to modify the value. 4. Press the "right-side button" again to enter set 7. 10 SET 7. Temperature calibration 1. The LCD displays: TM-380 2. Directly increase or decrease the temperature value, press the to move the digit, and the selected digit will flash. 3. Press or to modify the value. 4. Press the "right-side button" again to enter set 8. SET 8. Humidity calibration 1. The LCD displays: 2. Directly increase or decrease the temperature value, press the to move the digit, and the selected digit will flash. 3. Press or to modify the value. 4. Press the right-side button again to return to the measurement mode. 11 TM-380 6 General Specifications Real-time measurement of CO2/PM2.5/PM10/temperature/humidity. Maximum / minimum / average value. Auto-power on / off function. Adjustment and calibration function (CO2/temperature/humidity). CO2/PM2.5/PM10 red backlight alarm. Manual record and auto-record. Key sound assists to ensure the operation works. Overload indication . Battery: 3.7V 2000mAh rechargeable lithium battery Transformer for charging: 1A/5V Battery life: continuous use for approximately 6 hours 5V micro USB interface for external power supply When battery-low indicator shows as the following figure, the power will be turned off after 5 seconds. Charging indication: The battery indicator will sequentially vary as from right to left during charging and keep when fully charged. °C or °F unit selection. When the external power supply is connected, the auto-power off is disabled, and the white backlight is always on. 12 TM-380 CO2 /PM2.5/PM10 red backlight alarm setting function Setting CO2 PM2.5 PM10 value 1000PPM 35µg/m³ 75µg/m³ When the measured value reaches the setting value for alarm, the LCD backlight shines in red and related measurement items flash. 20 logs for manual and automatic recording values. Auto-recording time interval setting: 5 seconds, 10 seconds, 5 minutes, 10 minutes, 20 minutes, 30 minutes, 60 minutes. Sampling time: 2.5 seconds (5 types, 0.5 seconds for each). Dimensions: 150x65x22mm (L x W x H). Weight: 190 g. Operating temperature and humidity: 0°C ~ +50°C, <80%RH (no condensation). Storage temperature and humidity: 0°C ~ +60°C, <70%RH (no condensation). Display size: 52mm (L) x 40mm (W). Caution If to use the meter in a high-humidity environment, please place the meter in a low-humidity environment for 24 hours after use. 13 TM-380 7 General Specifications Ambient temperature range for accurate measure: 18°C (64°F) ~ 28°C (82°F) 7.1 PM2.5 Sensor Measuring range Accuracy Resolution Reaction time Laser particulate matter sensor 0-500 g/m3 ±8g :<=50µg/m3 ±10% of reading value:>50µg/m3 1 <10seconds 7.2 PM10 Sensor Measuring range Accuracy Resolution Reaction time 7.3 CO2 Sensor Measuring range Accuracy Resolution Reaction time Laser particulate matter sensor 0-500 g/m3 ±10g :<=50µg/m3 ±15% of reading value:>50µg/m3 1 <10 seconds Non-Dispersion Infrared(NDIR) 400 to 9999ppm ±70ppm ±3% of readings. (400-2000ppm) ±1ppm 90% during about 2 minutes 14 TM-380 7.4 Temperature Sensor Effective range Accuracy Resolution Reaction time Bandgap temperature sensor -10°C~50°C / 14°F~122°F ±1.0°C/±1.8°F (Non-charging and 30 minutes after charging) 0.1°C / 0.1F (0~35°C / 32°F~95°F) ; 1°C / 1°F (Above 100°C /°F or below -10°C /°F) About 1 second 7.5 Humidity Sensor Effective range Accuracy Resolution Reaction time Capacitive humidity sensor 1-99% ±5.0%RH(10~90%); ±8.0%RH(<10%,>90%) no condensation, at 25°C 0.1% About 4 seconds 15 TM-380 8 Maintenance or Repair 1.For the battery-low indicator: indicates the battery full; indicates the battery low, please charge it in time. 2.If dirty, please wipe it with a soft cloth, such as a glasses cloth. Do not wipe it with chemical solvents. 3.If fault on the meter, it can only be sent to the authorized service suppliers or sent back to the original factory for maintenance. Caution When the LCD shows the battery-low indicator , please charge it in time. 9 Product disposal Caution: This symbol indicates that this product and its accessories shall be subject to a separate collection and correct disposal, please not throw it away directly to avoid environmental pollution. 16 Professional Electrical and Environment Test & Measurement Instruments: LED light meter, Temperature & Humidity meter,Infrared Thermometer, Sound level meter, Light meter, EMF meter, UV Light meter, RF meter, Hot wire Anemometer, Co meter,Anemometer, Lan cable tester, Co2 meter, Solar power meter, Radiation meter, Clamp meter, Multimeter, Phase Rotation test, Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS CO., LTD. 6F, NO.586 Ruiguang Rd, Neihu Dist. Taipei City, Taiwan E-mail: service@tenmars.com http://www.tenmars.comHB2TM3800000 英文說明書 V3 Gaaiho PDF