This document provides product fiche information for Inventor's Multi Split Air Conditioning Systems. It details various models and their technical specifications for cooling and heating performance.
Product Models
The following models are covered:
- U6RSL(2)-18
- U6RSL(3)-27
- U5MRSL32(4)-36
Specifications by Unit Type
Wall Mounted Units
Specification | U6RSL(2)-18 AR5VI-09WiFi | U6RSL(3)-27 AR5VI-09WiFi | U5MRSL32(4)-36 AR5VI-09WiFi |
---|---|---|---|
Sound power level (indoor/outdoor) [dB(A)] | 54/65 | 55/68 | 54/70 |
Refrigerant/Mass [kg] | R32/1.25 | R32/1.85 | R32/2.10 |
GWP | 675 | 675 | 675 |
CO₂ equivalent (tonnes) | 0.84 | 1.25 | 1.42 |
SEER | 6.1 | 6.1 | 6.5 |
Energy class in cooling mode | A++ | A++ | A++ |
Annual electricity consumption in cooling [1] [KWh/y] | 304 | 453 | 565 |
Design load in cooling mode (P design) [KW] | 5.3 | 7.9 | 10.5 |
SCOP (average heating season) | 4.0 | 4.0 | 4.0 |
Energy class in heating (average season) | A+ | A+ | A+ |
Annual electricity consumption in heating (average season) [2] [KWh/y] | 1503 | 1995 | 3226 |
Warmer heating season | - | - | - |
Colder heating season | - | - | - |
Design load in heating mode (P design average season) [KW] | 4.3 | 5.7 | 9.2 |
Declared capacity at reference design condition (heating average season) [KW] | 3.400 | 5.122 | 8.200 |
Back up heating capacity at reference design condition (heating average season) [KW] | 0.900 | 0.578 | 1.000 |
Wall Mounted Units (Alternative Model Numbers)
Specification | U6RSL(2)-18 LN2UVI-09WFI | U6RSL(3)-27 LN2UVI-09WFI | U5MRSL32(4)-36 LN2UVI-09WFI |
---|---|---|---|
Sound power level (indoor/outdoor) [dB(A)] | 55/65 | 56/69 | 56/69 |
Refrigerant/Mass [kg] | R32/1.25 | R32/1.85 | R32/2.1 |
GWP | 675 | 675 | 675 |
CO₂ equivalent (tonnes) | 0.84 | 1.25 | 1.42 |
SEER | 5.6 | 5.6 | 5.6 |
Energy class in cooling mode | A+ | A+ | A+ |
Annual electricity consumption in cooling [1] [KWh/y] | 331 | 494 | 644 |
Design load in cooling mode (P design) [KW] | 5.3 | 7.9 | 10.3 |
SCOP (average heating season) | 3.8 | 3.8 | 3.8 |
Energy class in heating (average season) | A | A | A |
Annual electricity consumption in heating (average season) [2] [KWh/y] | 1584 | 2100 | 3132 |
Warmer heating season | - | - | - |
Colder heating season | - | - | - |
Design load in heating mode (P design average season) [KW] | 4.3 | 5.7 | 8.5 |
Declared capacity at reference design condition (heating average season) [KW] | 3.849 | 5.162 | 7.699 |
Back up heating capacity at reference design condition (heating average season) [KW] | 0.451 | 0.538 | 0.801 |
Cassette Units
Specification | U6RSL(2)-18 LV6CI-09WiFiR | U6RSL(3)-27 LV6CI-09WiFiR | U5MRSL32(4)-36 LV6CI-09WiFiR |
---|---|---|---|
Sound power level (indoor/outdoor) [dB(A)] | 56/65 | 55/68 | 53/68 |
Refrigerant/Mass [kg] | R32/1.25 | R32/1.85 | R32/2.10 |
GWP | 675 | 675 | 675 |
CO₂ equivalent (tonnes) | 0.84 | 1.25 | 1.42 |
SEER | 6.1 | 6.1 | 6.1 |
Energy class in cooling mode | A++ | A++ | A++ |
Annual electricity consumption in cooling [1] [KWh/y] | 304 | 453 | 608 |
Design load in cooling mode (P design) [KW] | 5.3 | 7.9 | 10.6 |
SCOP (average heating season) | 4.0 | 4.0 | 4.0 |
Energy class in heating (average season) | A+ | A+ | A+ |
Annual electricity consumption in heating (average season) [2] [KWh/y] | 1506 | 1882 | 2939 |
Warmer heating season | - | - | - |
Colder heating season | - | - | - |
Design load in heating mode (P design average season) [KW] | 4.3 | 5.3 | 8.4 |
Declared capacity at reference design condition (heating average season) [KW] | 3.320 | 4.633 | 8.126 |
Back up heating capacity at reference design condition (heating average season) [KW] | 0.980 | 0.667 | 0.274 |
Ducted Units
Specification | U6RSL(2)-18 LV6DI-09WiFiR | U6RSL(3)-27 LV6DI-09WiFiR | U5MRSL32(4)-36 LV6DI-09WiFiR |
---|---|---|---|
Sound power level (indoor/outdoor) [dB(A)] | 58/65 | 56/68 | 57/67 |
Refrigerant/Mass [kg] | R32/1.25 | R32/1.85 | R32/2.10 |
GWP | 675 | 675 | 675 |
CO₂ equivalent (tonnes) | 0.84 | 1.25 | 1.42 |
SEER | 6.1 | 6.1 | 6.1 |
Energy class in cooling mode | A++ | A++ | A++ |
Annual electricity consumption in cooling [1] [KWh/y] | 304 | 453 | 613 |
Design load in cooling mode (P design) [KW] | 5.3 | 7.9 | 10.6 |
SCOP (average heating season) | 3.8 | 4.0 | 3.8 |
Energy class in heating (average season) | A | A+ | A |
Annual electricity consumption in heating (average season) [2] [KWh/y] | 1698 | 1960 | 3246 |
Warmer heating season | - | - | - |
Colder heating season | - | - | - |
Design load in heating mode (P design average season) [KW] | 4.6 | 5.6 | 8.8 |
Declared capacity at reference design condition (heating average season) [KW] | 3.850 | 5.228 | 8.036 |
Back up heating capacity at reference design condition (heating average season) [KW] | 0.750 | 0.372 | 0.764 |
Console Units
Specification | U6RSL(2)-18 LV6LI-09WiFiR | U6RSL(3)-27 LV6LI-09WiFiR | U5MRSL32(4)-36 LV6LI-09WiFiR |
---|---|---|---|
Sound power level (indoor/outdoor) [dB(A)] | 54/65 | 54/70 | 54/70 |
Refrigerant/Mass [kg] | R32/1.25 | R32/1.85 | R32/2.10 |
GWP | 675 | 675 | 675 |
CO₂ equivalent (tonnes) | 0.84 | 1.25 | 1.42 |
SEER | 6.9 | 6.7 | 6.7 |
Energy class in cooling mode | A++ | A++ | A++ |
Annual electricity consumption in cooling [1] [KWh/y] | 269 | 413 | 549 |
Design load in cooling mode (P design) [KW] | 5.3 | 7.9 | 10.5 |
SCOP (average heating season) | 4.0 | 4.0 | 4.0 |
Energy class in heating (average season) | A+ | A+ | A+ |
Annual electricity consumption in heating (average season) [2] [KWh/y] | 1575 | 2030 | 2870 |
Warmer heating season | - | - | - |
Colder heating season | - | - | - |
Design load in heating mode (P design average season) [KW] | 4.5 | 5.8 | 8.2 |
Declared capacity at reference design condition (heating average season) [KW] | 4.043 | 5.349 | 7.318 |
Back up heating capacity at reference design condition (heating average season) [KW] | 0.457 | 0.451 | 0.882 |
Important Information Regarding Refrigerant
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [675]. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [675] times higher than 1kg of CO₂, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
Contains fluorinated greenhouse gases.
[1] [2] Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
Note: Please check the model information above according to the model name on the nameplate.