User Manual for kolin models including: KAM-55CMC32 HP Window Type Aircon, KAM-55CMC32, HP Window Type Aircon, Window Type Aircon, Type Aircon, Aircon

KAM-55CMC32 UPDATED USER MANUAL 111622

KAM 55CMC32 - USER MANUAL

Compact Series | Kolin


File Info : application/pdf, 24 Pages, 777.95KB

PDF preview unavailable. Download the PDF instead.

KAM-55CMC32 UPDATED USER MANUAL 111622 compressed
BJSDPOEJUJPOFS

XPSLT ZFBGPSTS

ZZZNROLQSKLOFRPSK

2ZQHU¶V0DQXDO

:,1'2:7<3(5220$,5&21',7,21(5 0RGHO.$0&0&
,03257$17127,&(
5HDGWKLVPDQXDOFDUHIXOO\EHIRUHLQVWDOOLQJRURSHUDWLQJ \RXUQHZDLUFRQGLWLRQLQJXQLW0DNHVXUHWRVDYHWKLV PDQXDOIRUIXWXUHUHIHUHQFH

Table of Contents
IMPORTANT SAFETY INSTRUCTIONS .........................................04
1.Warning .............................................................................................................................................................................04 2.Caution .............................................................................................................................................................................05 3.Operating Temperature ...............................................................................................................................................07 4.Note About Fluorinated Gasses ................................................................................................................................08 5.WARNING(for using R290/R32 refrigerant only)..................................................................................................08 6.SOCIABLE REMARK .........................................................................................................................................................15
NORMAL SOUNDS ......................................................................16
1.Points for using air conditioner..................................................................................................................................16 2.Noise level ........................................................................................................................................................................16 3.Power supply voltage ...................................................................................................................................................16 4.Energy Saving Ideas .......................................................................................................................................................16 5.Normal sounds.................................................................................................................................................................17
OPERATION INSTRUCTIONS ........................................................18
1.Control panel....................................................................................................................................................................18 2.Air directional louvers ...................................................................................................................................................18
INSTALLATION INSTRUCTIONS ...................................................19 
1.Suggested tools...............................................................................................................................................................19 2.Select the best location ................................................................................................................................................19
CARE AND CLEANING ..................................................................20
1.Air filter cleaning .............................................................................................................................................................20 2.Cabinet cleaning .............................................................................................................................................................20 3.Winter storage..................................................................................................................................................................20
TROUBLESHOOTING TIPS ............................................................21
1.Normal Operation...........................................................................................................................................................21 2.Abnormal Operation......................................................................................................................................................21 3.SPECIFICATIONS ..............................................................................................................................................................22

Important Safety Instructions

IMPORTANT SAFETY INSTRUCTIONS

READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.

8"3/*/( This symbol indicates the possibility of death or serious injury

$"65*0/ This symbol indicates the possibility of injury or damage to property.

/FWFSEPUIJT

"MXBZTEPUIJT

WARNING
Plug in power plug properly. Otherwise, it may cause electric shock or fire due to excess heat generation. Do not operate or stop the unit by inserting or pulling out the power plug.It may cause electric shock or fire due to heat generation. Do not damage or use an unspecified power cord.It may cause electric shock or fire. If the power cord is damaged, it must be replaced by the manufacturer or an authorised service centre or a similarly qualified person in order to avoid a hazard. Do not modify power cord length or share the outlet with other appliances. It may cause electric shock or fire due to heat generation. Do not operate with wet hands or in damp environment. It may cause electric shock. Do not direct airflow at room occupants only. This could damage your health. Always ensure effective earthing. Incorrect earthing may cause electric shock. Do not allow water to run into electric parts.It may cause failure of machine or electric shock. Always install circuit breaker and a dedicated power circuit. Incorrect installation may cause fire and electric shock. Unplug the unit or disconnect the power supply to the unit, if strange sounds, smell, or smoke comes from it.It may cause fire and electric shock. Do not use the socket if it is loose or damaged. It may cause fire and electric shock. Do not open the unit during operation. It may cause electric shock. Leave the door closed while the air conditioner is running.It is not designed to cool the entire house. Do not use the power cord close to heating appliances.It may cause fire and electric shock.

e Page 4 f

Important Safety Instructions

WARNING
Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc. It may cause an explosion or fire. Ventilate room before operating air conditioner if there is a gas leakage from another appliance.It may cause explosion, fire and burns. Do not disassemble or modify unit. It may cause failure and electric shock.
CAUTION
When the air filter is to be removed, do not touch the metal parts of the unit.It may cause an injury. Do not clean the air conditioner with water. Water may enter the unit and degrade the insulation. It may cause an electric shock. Ventilate the room well when used together with a stove, etc.An oxygen shortage may occur. When the unit is to be cleaned, switch off, and turn off the circuit breaker. Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury. Do not put a pet or house plant where it will be exposed to direct air flow.This could injure the pet or plant. Do not use for special purposes.Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc. Stop operation and close the window in storm or hurricane. Operation with windows opened may cause wetting of indoor and soaking of household furniture. Hold the plug by the head of the power plug when taking it out. It may cause electric shock and damage. Turn off the main power switch when not using the unit for a long time. It may cause failure of product or fire. Do not place obstacles around air-inlets or inside of air-outlet. It may cause failure of appliance or accident. Always insert the filters securely. Clean filter once every two weeks. Operation without filters may cause failure. Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure. If bracket is damaged, there is concern of damage due to falling of unit. Do not use strong detergent such as wax or thinner but use a soft cloth.Appearance may be deteriorated due to change of product color or scratching of its surface. Do not place heavy object on the power cord and ensure that the cordis not compressed. There is danger of fire or electric shock. Do not drink water drained from air conditioner.It contains contaminants and could make you sick. Use caution when unpacking and installing. Sharp edges could cause injury. If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out or disconnect the power supply to the unit,and contact a qualified service technician.
e Page 5 f

Important Safety Instructions

CAUTION
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. (be applicable for the European Countries ) This appliance is not intended for use by persons (including children) with reduced physical ,sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. (be applicable for other countries except the European Countries ) Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons inorder to avoid a hazard. The appliance shall be installed in accordance with national wiring regulations. Do not operate your air conditioner in a wet room such as a bathroom or laundry room. The appliance with electric heatershall have at least 1 meter space to the combustible materials. Contact the authorised service technician for repair or maintenance of this unit. Contact the authorised installer for installation of this unit. If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply or disconnect the power supply to the unit, immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance. In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning. To reduce the risk of fire or electric shock, do not use this fan with any solidstate speed control device. Do not run cord under carpeting. Do not cover cord with throw rugs,runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over. If connecting power to fixed wiring, an all-pole disconnection device which has at least 3mm clearances in all poles, and have a leakage current that may exceed 10mA, the residual current device(RCD) having a rated residual operating current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. How to fix the appliance to its support, please read the installation instructons section in this manual. All wiring must be performed strictly in accordance with the wiring diagram located inside of the unit.
e Page 6 f

Important Safety Instructions

Preparing for operation
1. Contact an installation specialist for installation. 2. Plug in the power plug properly. 3. Do not use a damaged or non-standard power cord. 4. Do not share the same outlet with other appliances. 5. Do not use an extension cord. 6. Do not start/stop operation by plugging/unplugging the power cord.

Usage
1. Exposure to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g. Preserving precision devices, food, pets, plants, and art objects). Usage in such a manner could harm such property.
Cleaning and maintenance
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
3. When cleaning and maintenance the unit, first make sure that the power and circuit breaker are turned off.
Operating Temperature

Cooling operation Heating operation

Outdoor temp: Indoor temp: Outdoor temp: Indoor temp:

Note:Performance may be reduced outside of these operating temperatures.
Auto-Restart(on some models)
If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting automatically when the power resumes.
Wait 3 minutes before resuming operation After the unit has stopped, it can not be restarted operation in the first 3 minutes. This is to protect the unit. Operation will automatically start after 3 minutes.

e Page 7 f

Important Safety Instructions

CAUTION
Before installing, remove all packaging from inside the carton, along with any inserts placed into the side louvers.

Inserts placed into the side louvers.

Remove inserts placed into the side louvers.

Note About Fluorinated Gasses

-Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific information on the type, the amount and the CO2equivalent in tonnes of the fluorinated greenhouse gas(on some models), please refer to the relevant label on the unit itself. -Installation, service, maintenance and repair of this unit must be performed by a certified technician. -Product uninstallation and recycling must be performed by a certified technician.

WARNING(for using R290/R32 refrigerant only)

Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater). Do not pierce or burn. Be aware that the refrigerants may not contain an odour. Appliance should be installed, operated and stored in a room with a floor area larger than 4 m2 . Compliance with national gas regulations shall be observed. Keep ventilation openings clear of obstruction. The appliance shall be stored so as to prevent mechanical damage from occurring. A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation. Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification. Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.

e Page 8 f

Important Safety Instructions

Caution: Risk of fire/ flammable materials 3FRVJSFEGPS33VOJUTPOMZ


IMPORTANT NOTE:Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

Explanation of symbols displayed on the unit(For the unit adopts R32/ R290 Refrigerant only):

This symbol shows that this appliance used a flammable refrigerant. If the WARNING refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.

CAUTION This symbol shows that the operation manual should be read carefully.

CAUTION

This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.

CAUTION

This symbol shows that information is available such as the operating manual or installation manual.

WARNINGS (for using R290/R32 refrigerant only)
1.Transport of equipment containing flammable refrigerants See transport regulations
2.M arking of equipment using signs See local regulations 3.Disposal of equipment using flammable refrigerants See national regulations. 4.Storage of equipment/ appliances The storage of equipment should be in accordance with the manufacturer's instructions. 5.Storage of packed (unsold) equipment Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations. 6.Information on servicing 1)Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

e Page 9 f

Important Safety Instructions

WARNINGS (for using R290/R32 refrigerant only)
2)Work procedure Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed.
3)General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
4)Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
5)Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area. 6)No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed. 7)ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. 8)Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall be followed. If in doubt consult the manufacturer's technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: The charge size is in accordance with the room size within which the refrigerant containing parts are installed; The ventilation machinery and outlets are operating adequately and are not obstructed; If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
e Page 10 f

Important Safety Instructions

WARNINGS (for using R290/R32 refrigerant only)
Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded. 9)Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include: That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; That there no live electrical components and wiring are exposed while charging, recovering or purging the system; That there is continuity of earth bonding. 7.Repairs to sealed components 1)During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it isabsolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation. 2)Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that apparatus is mounted securely. Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer's specifications. NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them. 8.Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
e Page 11f

Important Safety Instructions

WARNINGS (for using R290/R32 refrigerant only)
9.Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans. 10.Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used. 11.Leak detection methods The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/ extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process. 12.Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. Opening of the refrigeration systems shall not be done by brazing. The following procedure shall be adhered to: Remove refrigerant; Purge the circuit with inert gas; Evacuate; Purge again with inert gas; Open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
e Page12 f

Important Safety Instructions

WARNINGS (for using R290/R32 refrigerant only)
13.Charging procedures In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them. Cylinders shall be kept upright. Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. Label the system when charging is complete (if not already). Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site. 14.Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced. a)Become familiar with the equipment and its operation. b)Isolate system electrically. c)Before attempting the procedure ensure that: Mechanical handling equipment is available, if required, for handling refrigerant cylinders; All personal protective equipment is available and being used correctly; The recovery process is supervised at all times by a competent person; Recovery equipment and cylinders conform to the appropriate standards. d)Pump down refrigerant system, if possible. e)If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system. f)Make sure that cylinder is situated on the scales before recovery takes place. g)Start the recovery machine and operate in accordance with manufacturer's instructions. h)Do not overfill cylinders. (No more than 80 % volume liquid charge). i)Do not exceed the maximum working pressure of the cylinder, even temporarily. j)When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off. k)Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked. 15.Labelling Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
e Page 13f

Important Safety Instructions

WARNINGS (for using R290/R32 refrigerant only)
16.Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.
e Page 14 f

Important Safety Instructions

SOCIABLE REMARK When using this unit in the European countries, the following informations must be followed: DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: (A) The municipality has established collection systems, where electronic waste can be disposed
of at least free of charge to the user. (B) When buying a new product, the retailer will take back the old product at least free of charge. (C) The manufacture will take back the old appliance for disposal at least free of charge to the
user. (D) As old products contain valuable resources, they can be sold to scrap metal dealers. Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.
e Page 15 f

Normal Sounds

NORMAL SOUNDS

Points for using air conditioner

Energy Saving Ideas

WARNING
To reduce the risk of fire, electric shock, or injury to persons, read the Safety Precautions before operating this appliance.
NOTE: If the air conditioner is turned off, wait 3 minutes before restarting. This allows pressure inside the compressor and equalize. Failure to follow these instructions may be harmful to your unit.
Noise level

t5IFDBQBDJUZPGUIFSPPNBJSDPOEJUJPOFS must fit the room size for efficient and satisfactory operation. t*OTUBMMUIFSPPNBJSDPOEJUJPOFSPOUIFTIBEZ side of your room. t%POPUCMPDLBJSøPXJOTJEFXJUICMJOET
 curtains or furniture; or outside with shrubs, enclosures, or other buildings. t,FFQCMJOETBOEESBQFTJOPUIFSXJOEPXT closed during the sunniest part of the day. t$MFBOUIFBJSöMUFSBTSFDPNNFOEFEJOUIF section "Care and Cleaning ".

Noise from the air conditioner will be louder at night than in the daytime. This is because noise in the surroundings is comparatively low at night. If you feel that noise of the air conditioner is too loud, switch the thermostat to lower numbers.

Power supply voltage
If the power supplied to the unit is not within plus/minus 10% of the specified rating, the unit may not function and the fuse may blow.

e Page 16 f

Normal Sounds

Normal sounds

1 Sound of Rushing Air

3

At the front of the unit, you may hear the sound

of rushing air being moved by the fan.

4

2 Gurgle/Hiss

1

"Gurgling or hissing "noise may be heard due to

refrigerant passing through evaporator during

5

normal operation.

3 High Pitched Chatter

High efficiency compressors may have a high

2

pitched chatter during the cooling cycle.

For some models

4 Vibration Unit may vibrate and make noise because of poor
wall or window construction or incorrect installation.

Water plug

5 Pinging or Switching Droplets of water hitting condenser during normal operation may cause "pinging or swishing" sounds. This noise can be reduce by removing the water plug at the bottom of unit's rear as shown below. Removing this plug will lower the Energy Efficiency of your unit. Note: Don't try to drill any holes on the base pan to eliminate the normal sounds, otherwise it will void the warranty

NOTE:
All the illustrations in this manual are for explanation purpose only. The air conditioner you have may be slightly different. The actual shape shall prevail.

e Page 17 f

OPERATION INSTRUCTIONS

Operation instructions

The control panel of the unit you bought may be look like one of the following:

TEMPERATURE

max cool 7

min 1 cool
2

3

6

4

5

lo

lo

fan

cool

OFF

hi cool
hi fan
COOLING

Wait Three Minutes Before Restarting

TEMPERATURE

max cool

7

min 1 cool
2

3 6

5 Low Cool

4 Low Fan

OFF

High

Cool

High

Fan

COOLING

Center handle(3)
Air Direction
e Page 18 f

Control Panel
The controls featured in this manual are representative of many available models. Your model may offer slightly different features. Cool Mode The desired cool setting is selected by rotating the knob to the right to the appropriate location. "HI COOL" has maximum cooling effect and airflow. "LO COOL" has minimum cooling effect and airflow. Fan Mode Rotate the knob to the left to select your choice of fan speeds for air circulation. NOTE: When selecting a fan speed, the compressor will not run. Thermostat The thermostat is used to set the desired room temperature when the unit is being operated in the COOL MODE. To set the desired room temperature, rotate the thermostat switch to the desired setting. After the set temperature is achieved the thermostat will automatically start and stop the compressor in order to maintain the desired set temperature. Rotate the thermostat selector clockwise for higher cool settings. Higher cool settings will provide lower room temperature. Rotate the thermostat selector counter clockwise for lower cool settings. Lower cool settings will provide higher room temperature.
Please always wait 3 minutes when turning unit off then on again, and when changing from cool to fan and back to cool. This prevents compressor from overheating & possible circuit breaker tripping.
Air Directional Louvers
The louvers will allow you to direct the air flow Left or Right throughout the room as needed. Move the Center handle from side to side until the desired Left/Right direction is obtained.

INSTALLATION INSTRUCTIONS

Installation Instructions

Select the best location
AWNING FENCE
3~4O

Note: Before installing, remove all packaging from inside the carton, along with any inserts placed into the side louvers.
Suggested tools
1 . Screw driver (medium size Phillips) 2. Tape measure or ruler 3. Knife or scissors 4. Level gaug

75~150cm

Over 50cm

Note: Unit may be supported by a solid frame from below or by a hanger from a solid overhead support.
Installations of the unit into the wall

AIR IN

AIR IN

AIR IN

AIR OUT 100mm minimum
OPTION A

45O BRICK CUT AWAY TO CLEAR LOUVRES

45O BRICK CUT AWAY TO CLEAR LOUVRES
FRONT

BRICK WALL

100mm

BRICK WALL

AIR IN LOUVRE

TOP VIEW

AIR OUT
OPTION B

AIR IN 100mm

Select the best location
1. To avoid vibration and noise, make sure the unit is installed securely and firmly.
2. Install the unit where the sunlight does not shine directly on the unit. I f the unit receives direct sunlight, build an awning to shade the cabinet.
3. There should be no obstacle, such as a fence or wall, within 50cm from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling and heating efficiency of the air conditioner.
4. Install the unit a little obliquely outward not to leak the condensed water into the room (about 3~4 Owith level).
5. Install the unit with its bottom portion 75~150cm above the floor level.
6. The power cord must be connected to an independent circuit. The yellow/green wire must be grounded.
CAUTION All side louvers of the cabinet must remain exposed to the outside of the structure.
Note: After installing, make sure the air conditioner is tilted 3~4° to the outside to allow water drainage and perfect cooling efficiency.
e Page 19 f

Care and cleaning

CARE AND CLEANING

Air Filter Cleaning

The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils. tRemove the filter by sliding out from the right-hand
side. tWash the filter using liquid dishwashing detergent
and warm water. Rinse filter thoroughly. tGently shake excess water from the filter. Be sure
the filter is thoroughly dry before replacing. Or, instead of washing you may vacuum the filter clean. Note: Never use hot water over 40°C(104°F) to clean the air filter. Never attempt to operate the unit without the air filter

Cabinet Cleaning

CAUTION Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent chock or fire hazards.
CAUTION
NEVER operate the air conditioner without the air filter, as dust/dirt particles can contribute to equipment failure.

tBe sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry.
tNever use harsh cleaners, wax or polish on the cabinet front.
tBe sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner.
tPlug in air conditioner.
Winter Storage

If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton

e Page 20 f

TROUBLESHOOTING TIPS

Save time and money! Review the chart below first and you may not need to call for service.
Normal Operation tYou may hear a pinging noise caused by water being picked up and thrown against the condenser
on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. tYou may hear the thermostat click when the compressor cycles on and off. tWater will collect in the base pan during high humidity or on rainy days .The water may overflow and drip from the outdoor side of the unit. tThe fan may continue to operate when the compressor has cycled off.
Abnormal Operation

Problem
Air conditioner does not start
Air conditioner does not cool as it should
Air conditioner freezing up

Possible Causes The air conditioner is unplugged. The fuse is blown/circuit breaker is tripped.
Power failure.
Airflow is restricted .
The air filter is dirty. The room may have been hot. Cold air is escaping. Cooling coils have iced up. Ice blocks the air flow and stops the air conditioner from cooling the room.

What To Do
Make sure the air conditioner plug is pushed completely into the outlet and switched on.
Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
If power failure occurs, switch off and disconnect/ unplug the power cord. When power is restored, reconnect (plug in) the power cord, switch on the power and wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.
Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.
Clean the filter at least every 2 weeks. See the care and cleaning section. When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns.
See Air Conditioner Freezing Up below.
Set the fan at MED or HIGH until the ice melts.

Troubleshoot ing Tips

e Page 21 f

SPECIFICATIONS Unit dimensions:
MODEL (Btu/h)
<7000
>7000

BODY DIMENSION(mm) (W X H X D) 406X306X335 406X306X390 471X340X400
471X340X400

NOTE: Value of D is for reference only.

Minimum norminal cross-sectional area of conductors:

Rated current of appliance(A) °3 and  6 °6 and  10 °10 and  16 °16 and  25

/PNJOBMD SPT T T FD UJPOBMB SFB NN
 0.75 1 1.5 2.5

Suggest Minimum Wire Size(AWG: American Wire Gage):

Appliance Amps
10 13 18 25 30

AWG Wire Size 18 16 14 12 10

Troubleshoot ing Tips

e Page 22 f

The design and specifications are subject to change without prior notice for product improvement. Any updates to the manual will be uploaded to the service website, please check for the latest version.

If you have any concerns, please contact us at the following:

Customer hotline: Text hotline: Email:

(02) 8852-6868 +63 917-881-8982 customerservice@kolinphil.com.ph

Also, please like and follow us on our social media accounts:
Facebook: kolinphilippines Instagram kolinphilippines Youtube: kolinphilippines Tiktok: kolinphilippines Website: www.kolinphil.com.ph

KPII111622
23



References

Adobe Illustrator CC 23.1 (Windows) iLovePDF