Philips HU2000 Series Humidifier
Models: HU2716 / HU2718
Important Safety Information
Read this user manual carefully before you use the appliance, and save it for future reference.
Danger
- Do not spray any flammable materials such as insecticides or fragrance around the appliance.
- Do not clean the appliance with water, any other liquid, or a (flammable) detergent to avoid electric shock and/or a fire hazard.
- The water in the water tank is not suitable for drinking. Do not drink this water and do not use it to feed animals or to water plants. When you empty the water tank, pour the water down the drain.
Warning
- Be aware that high humidity levels may encourage the growth of biological organisms in the environment.
- Do not permit the area around the humidifier to become damp or wet. If dampness occurs, turn the output of the humidifier down. If the humidifier output volume cannot be turned down, use the humidifier intermittently. Do not allow absorbent materials, such as carpeting, curtains, drapes, or tablecloths, to become damp.
- Never leave water in the reservoir when the appliance is not in use.
- Empty and clean the humidifier before storage. Clean the humidifier before next use.
- Check if the voltage indicated on the appliance corresponds to the local mains voltage before you connect the appliance.
- If the supply cord is damaged, it must be replaced by Philips, a service center authorized by Philips, or similarly qualified persons to avoid a hazard.
- Do not use the appliance if the plug, the power cord, or the appliance itself is damaged.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Do not insert your fingers or objects into the air outlet or the air inlet to prevent physical injury or malfunctioning of the appliance.
- Make sure that foreign objects do not fall into the appliance through the air outlet.
- Do not use this appliance when you have used indoor smoke-type insect repellents or in places with oily residues, burning incense, or chemical fumes.
- Do not use the appliance in wet surroundings or in surroundings with high ambient temperatures, such as the bathroom, toilet, or kitchen, or in a room with major temperature changes.
- Always unplug the appliance when you want to move, clean, fill the water, replace the filter or carry out maintenance.
- Do not wash the filter in a washing machine or dish washer, otherwise the filter will be deformed.
- When the appliance is not used for a long time, bacteria and mold may grow on the filter. Clean the water tank and dry the humidification filter. Check the filter before you start using the appliance again. If the filter is very dirty with dark spots, replace it.
Caution
- The appliance is only intended for household use under normal operating conditions.
- Always place and use the appliance on a dry, stable, flat and horizontal surface.
- Do not block the air inlet and outlet.
- Do not place anything on top of the appliance and do not sit or stand on the appliance.
- Only use the original Philips filter specially intended for this appliance. Do not use any other filter.
- Do not fill water from the air outlets on top of the appliance.
- Only fill the water tank with cold tap water. Do not use ground water or hot water.
- Do not put any substance other than water in the water tank. Do not add fragrance or chemical substance into the water. Use only water (tap, purified, mineral, any sort of potable water).
- Avoid knocking against the appliance (the air inlet and outlet in particular) with hard objects.
- Do not use the appliance near gas appliances, heating devices or fireplaces.
- Do not place the appliance directly below an air conditioner to prevent condensation from dripping onto the appliance.
Electromagnetic fields (EMF)
This Philips appliance complies with all applicable standards and regulations regarding exposure to electromagnetic fields.
Recycling
This symbol means that this product shall not be disposed of with normal household waste (2012/19/EU). Follow your country's rules for the separate collection of electrical and electronic products. Correct disposal helps prevent negative consequences for the environment and human health.
Guarantee and Service
If you need information or support, please visit www.philips.com/support or read the separate worldwide guarantee leaflet.
Order Parts or Accessories
If you have to replace a part or want to purchase an additional part, go to your Philips dealer or visit www.philips.com/support. If you have problems obtaining the parts, please contact the Philips Consumer Care Center in your country (you will find its phone number in the worldwide guarantee leaflet).
Product Overview and Operation
Model Identification: The product shown is part of the Philips FY3446 series humidifiers.
Operation in Dry Conditions: In dry conditions, moisture from the humidifier will be absorbed by walls, furniture, and other items in your room. Ventilation of dry outside air will also increase the time it takes to reach the target humidity. To optimize humidification performance, it is recommended to close doors and windows during use.
Control Panel and Modes
The control panel features several indicators and controls:
- Power Button [power-symbol]: Turns the humidifier on or off.
- Humidity Indicator ?: Shows the current humidity level.
- Timer Indicator ⏱️: Indicates the timer setting.
- Fan Speed Indicator ?: Shows the current fan speed.
Operating Modes:
- Auto/Otomatik: The humidifier automatically adjusts its operation to maintain a set humidity level.
- Sleep/Uyku (SL): A mode designed for quieter operation, often with dimmed lights, suitable for nighttime use.
- Manual/Manuel: Allows manual selection of fan speed. Options typically include 1, 2, and 3, representing different fan speeds.
Setting Target Humidity
You can set the desired humidity level on the display. Options may include specific percentages (e.g., 40%, 50%, 60%). If the humidity level "--%" is selected, the humidifier will keep working until the humidity level reaches 70% RH.
Setting the Timer
The timer function allows you to set the duration of operation. You can select time intervals, typically from 1 hour up to 9 hours.
Assembly and Setup
Follow these steps to set up your humidifier:
- Fill Water Tank: Open the top of the humidifier and fill the water tank with cold tap water. Do not fill past the 'Max' line. Avoid using hot water or ground water. Ensure the water level is visible.
- Plug In: Connect the power cord to a suitable electrical outlet.
- Place Top Cover: Position the top cover correctly onto the base unit.
- Insert Filter Assembly: Place the filter assembly, which includes the humidification filter, into the base of the unit.
- Place Main Unit: Position the main body of the humidifier onto the assembled base.
Diagram Description: The diagrams illustrate filling the water tank to the indicated level (e.g., 50%), plugging the appliance into a power outlet, placing the top cover, inserting the filter assembly, and finally placing the main unit onto the base.
Maintenance
Regular maintenance ensures optimal performance and longevity of your humidifier.
Weekly Cleaning
Clean the humidification filter every week. Please soak the humidification filter with a mild or acid cleanser (e.g., 24g citric acid with 4L water) for 1 hour. After soaking, rinse thoroughly.
Diagram Description: The diagrams show unplugging the appliance, removing the filter, soaking it in a cleaning solution for 1 hour, and then rinsing it.
Filter Replacement
Replace the humidification filter every 6 months. This helps prevent the buildup of bacteria and mold, especially if the appliance is not used for extended periods.
Diagram Description: The diagrams illustrate unplugging the appliance, removing the old filter and disposing of it, and then inserting a new filter into the filter assembly and placing it back into the base.