FSP090-AxxN3 Series 90W Adapter
Technical Datasheet
Features
- Certified IEC 62368-1 & CB 60950-1
- Meets USA EISA 2007
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- Low Profile
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
- With PFC Circuit
Safety Standard Approval
Approvals include TÜV Rheinland, cULus Listed, CE, FCC, and CCC certifications. Tested to Comply With FCC Standards FOR HOME OR OFFICE USE.
Description
This product is a 90-watt AC to DC adapter intended for use in IPC systems, embedded systems, printers, monitors, POS systems, and PoE applications that have high wattage demands. This adapter operates at 90 to 264 VAC input voltage. The unit meets CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits, and is designed for ITE application.
Input Specifications
- Input voltage: 90-264 VAC
- Input frequency: 47-63 Hz
- Input current: 100Vac, 240Vac / full load ≤ 1.2A
- No load power consumption: 115Vac, 230Vac ≤ 0.5W
- Touch current: 264Vac / 50Hz ≤ 0.25mA
Input Specifications (Continued)
- Power factor: 115Vac, 230Vac / full load ≥ 0.9
- Harmonic reduction: Provisions for adding harmonic reduction per EN 61000-3-2 must be present.
- Power turn-on time: At 100Vac / full load, output voltage shall remain regulation ≤ 3Sec
- Hold-up time: At 100Vac or 240Vac / full load, output voltage shall remain regulation ≥ 10ms
- Inrush current: 100Vac, 240Vac / full load, Shall be less than the rating of adapter critical component (including rectifiers, fuse, surge and current limiting device)
- Operating altitude: 5000 meters above sea level
- Withstand voltage: Between AC input and secondary applied DC 4242V, test time 1 minute, cut off current shall be less than 10mA
- MTBF: 100Vac, 240Vac / full load, 300,000 hours at 25°C, standard SR332
Output Specifications
- Output voltage/current: See rating chart
- Total output power: 90W
- Protection:
- Over voltage: The adapter will enter into shut down when over voltage happens at the output terminal due to an internal fault. The output trip voltage shall not exceed 29/35/60/65* volts. It will return to normal state by AC reset.
- Short circuit & Over current: When an internal fault occurs, or an external fault is applied to the power supply causing an overload or short circuit at the output, the power supply shall shut down and enter auto-recovery mode.
- Over temperature: The power supply will enter into shut down when abnormal thermal rise occurs. It will return to normal state by AC reset.
- Brown-out: Set at 60Vac~70Vac
Environment
- Working TEMP.: 0~70°C (≥ 40°C de-rating)
- Storage TEMP.: -20~+80°C
- Working Humidity: 20~80% RH non-condensing
- Storage Humidity: 10~90% RH non-condensing
EMC Performance
Details on EMC performance standards:
- EN55032: Class B conducted, Class B radiated
- FCC: Class B conducted, Class B radiated
- VCCI: Class B conducted, Class B radiated
- EN61000-3-2: Meet class D
- EN61000-3-3: Meet regulation
- EN61000-4-2: Air discharge: ±15 KV, contact discharge: ±8KV, meet criterion A
- EN61000-4-3: 80~1000 MHz, 3V/m, 80% AM(1kHz), meet criterion A
- EN61000-4-4: Impulse: ±1kV applied to L, N, meet criterion A
- EN61000-4-5: ±1kV applied differential mode, ±2kV applied common mode, meet criterion A
- EN61000-4-6: 0.15~80 MHz, 3Vrms, 80% AM(1kHz), meet criterion A
- EN61000-4-8: 50 Hz or 60Hz, 1A/m, meet criterion A
- EN61000-4-11: Voltage Dips: >95% reduction for 0.5 period, meet criterion B; 30% reduction for 25 period, meet criterion C. Voltage Interruptions: >95% reduction for 250 period, meet criterion C.
Power Derating
Derating applies for operation at 100Vac or 240Vac under varying temperature conditions: 0°C to 40°C at 100% load, 50°C at 85% load, 60°C at 70% load, and 70°C at 55% load. This derating must be less than the rating of the adapter's critical components, following FSP specifications.
Performance Curves
Input Voltage Derating Curve: This graph illustrates that the adapter maintains 100% output power across the input voltage range of 90-240 VAC. Output power is gradually reduced as the input voltage increases from approximately 240 VAC to 264 VAC.
Output Power Derating Curve: This graph shows that the adapter operates at 100% maximum load up to approximately 40°C ambient temperature. Beyond 40°C, the maximum load capacity is derated as the temperature increases.
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency (DOE Level VI) | Efficiency (CoC V5, Tier 2) | Over Voltage Protection |
---|---|---|---|---|---|---|
FSP090-ABAN3 | 19V | 4.74A | C14 | ≥88% | ≥89% | 29 Volts |
FSP090-ABBN3 | 19V | 4.74A | C6 | 29 Volts | ||
FSP090-AAAN3 | 24V | 3.75A | C14 | 35 Volts | ||
FSP090-AABN3 | 24V | 3.75A | C6 | 35 Volts | ||
FSP090-AFAN3 | 48V | 1.88A | C14 | 60 Volts | ||
FSP090-AFBN3 | 48V | 1.88A | C6 | 60 Volts | ||
FSP090-AWAN3 | 54V | 1.67A | C14 | 65 Volts | ||
FSP090-AWBN3 | 54V | 1.67A | C6 | 65 Volts |
Mechanical Specifications
Detailed dimensional drawings are provided, illustrating the physical layout, dimensions, and cable lengths of the adapter unit and its associated components. These specifications are crucial for integration into various systems.
Connector Specifications
This section outlines the connector types, cable tie configurations, and specific cable wire types (e.g., UL11352 18AWG). It also details the application of heat-shrink tubing for insulation and strain relief on the connectors.