User Manual for Gemtek models including: DQG01, 2ASKH-DQG01, 2ASKHDQG01, 4-8470-10 Tracking Device, 4-8470-10, Tracking Device

Tony Wang

User Manual

PHILLIPS CONNECT TECHNOLOGIES LLC DQG01 Dagger QG and Dagger QG Slim 2ASKH-DQG01 2ASKHDQG01 dqg01

Dagger-QG User Manua

User Manual © 2022 Phillips Connect Technologies LLC 2 / 9 Contents


File Info : application/pdf, 9 Pages, 681.14KB

DQG01-Users-Manual-PHILLIPS-CONNECT-2askh-dqg01-ex-1-29
User Manual
Dagger-QG User Manua
Dagger QG and Dagger QG Slim
4-8470-10 Tracking Device

The information presented in this document is strictly confidential and contains trade secrets and other confidential information that are the exclusive property of Phillips Connect Technologies.

Author Tony_Wang

Revision V01

Changes Initial version

Date 2022-01-06

© 2022 Phillips Connect Technologies LLC

1 / 9

User Manual

Contents

1 Introduction

3

2 Hardware Design

4

2.1 Basic Hardware

4

2.2 Basic RF Performance

5

2.3 Certification and Safety

6

3 Test Items

7

3.1 Hardware

7

3.2 Software

7

Mechanical Structure(mm)

8

FCC/IC Statement

9

© 2022 Phillips Connect Technologies LLC

2 / 9

User Manual
1 Introduction
The Dagger-QG is a self-contained tracking device that combines the GPS with LTE and BLE connectivity. The Dagger-QG is a single endpoint device to a user or a server application. It can be quired, updated and configured either through a serial connection, or an over the air LTE IPnetwork. The Dagger-QG presents itself over these connections as an enhanced cellular modem with attached functional elements.
These elements include:  GPS location engine  General Purpose I/O (GPIO) pins  Serial UART port  Voltage monitor  BLE5.0
Application scene:

© 2022 Phillips Connect Technologies LLC

3 / 9

User Manual

2 Hardware Design

2.1 Basic Hardware Items
Baseband Chipset RF Transceiver Memory Air Interface Frequency
Antenna GPS Antenna Interface
Battery Monitor Watchdog Motion Detect LED Battery Power Cable connector type Power Consumption

Requirement Qualcomm Cat.M1 Qualcomm SDR Internal
Support for LTE Cat.M1
4G band support : Band 2/4/5/12/13/25/26 BLE5.0 band support : ISM 2.4GHz Internal Antenna / Chip Antenna Dedicated high performance ceramic antenna UART TX UART RX 12V DC Input1A current GPI GPO GND Supported Supported Supported 2 LEDs (Red and Green) Built in battery8.8A non-chargeable 6 pin < 5Watts

The Dagger-QG provides support for specialized hardware features through AT commands. The features supported include the following.

GPS
The major functionality of the GPS system is to compute the correlation results between the incoming signal and the selected PRN code based on certain Carrier Doppler Frequency, Code Doppler Frequency, code phase, carrier phase, and the particular satellite the system is tracking or acquiring.

GPIO The GPIO pins are presented to the external environment on the main connector. They are general purpose bidirectional lines capable of providing system interrupts to generate a report or drive logic levels to external devices.

LEDs Two LED status indicators are provided to verify correct installation (Red) and operation (Green).

© 2022 Phillips Connect Technologies LLC

4 / 9

User Manual

UART
A UART port is provided for AT command and data interaction and optionally for application specific control.

Battery Monitor
The battery monitor is internal analog input scaled such that the DC value of the power input pin to the Dagger-QG system is measured.

Watchdog
Qualcomm chipset supports internal software and hardware Watchdog.

Motion Detect
This function will work with firmware power down options to keep the Dagger-QG in a very low power down state until motion is detected. Upon wakening, a report can then be generated.

2.2 Basic RF Performance

Over the Air

Requirements

TRP free space

CTIA

TIS free space

CTIA

Remark
TRP free space TIS free space

Radio Frequency
BLE5.0 Band Rx Spec Tx Spec 4G LTE Cat.M1 Band Rx Spec Tx Spec GPS Frequency Support

ISM 2.4GHz Follow Chipset Follow Chipset
Band 2/4/5/12/13/25/26 Follow 3gpp TS 36.521 Ch.7 Follow 3gpp TS 36.521 Ch.6
L1-band (1.57542GHz)

2.3 Certification and Safety

Items
Drop Design Temperature Range
Humidity:
FCC Certification IC Certification
ESD Requirement

Requirement
0.8meter 6 direction standard drop test -20 to 60°C Operation -40 to +85°C Storage 20% to 90% Operation 10% to 95% Storage
FCC Part 15/22/24/27/90 RSS-130/132/133/139/247
8KV non-Conductive

© 2022 Phillips Connect Technologies LLC

5 / 9

User Manual

3 Test Items

3.1 Hardware
Test Item Function Test
RF Test

Description · Power Input Test · Heat Dissipation Test · UART Stability Test · GPIO Level Test · LED Stability Test · Drop Down Test · ESD Test · High/Low Temperature Test · LTE Conformance Test · GPS Performance Test · BLE Performance Test · Antenna Performance Test

3.2 Software
Test Environment Construct  UART Test environment
1. Connect Dagger-QG to pc with console board. 2. Open Terminal tool and send the AT command. 3. Response can be shown at terminal window.

© 2022 Phillips Connect Technologies LLC

6 / 9

User Manual

Mechanical Structure (115*16*92 mm)

TOP

SIDE

BOTTOM

FRONT

© 2022 Phillips Connect Technologies LLC

7 / 9

User Manual
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
IMPORTANT NOTE : FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

© 2022 Phillips Connect Technologies LLC

8 / 9

User Manual
Industry Canada statement
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licenseexempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference (2) This device must accept any interference, including interference that may cause undesired operation of the device
L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) L'appareil ne doit pas produire de brouillage ; (2) L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Radiation Exposure Statement: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.
Déclaration d'exposition aux radiations: Cet équipement est conforme Canada limites d'exposition aux radiations dans un environnement non contrôlé. Cet équipement doit être installé et utilisé à distance minimum de 20 cm entre le radiateur et votre corps