OVERVIEW
The nLight ECLYPSETM system controller connects an nLight® lighting network to support connectivity and management over an IP network, control and device setting adjustment, integration with building management, integration with demand response, and more.
FEATURES
· Communicates over IP, allowing the system controller and connected lighting controls devices to be
accessed and configured across a local area network
· Each system controller supports up to 750 nLight and nLight AIR devices. Additional controllers can
connect and scale a system of lighting controls to a maximum of 20,000 devices
· BACnet Testing Laboratories (BTL) listed as a BACnet Building Controller (B-BC) · Can be discovered and managed through free SensorView software and through an onboard web GUI · Provides time-of-day and astronomical time clock capabilities for scheduled lighting control events · Manages forwarding of global control channels and system profiles to affect devices on multiple
controllers at the same time
· Enhanced security through toggleable HTTP or HTTPS connections, a FIPS 140-2, Level 1 compliant
security interface, SSO or Radius Server capabilities, and more
· Optional demand response client allows activation of configurable load shed dimming levels by utility
DRAS through OpenADR 2.0a

nLight ECLYPSETM
System Controller

Warranty Five-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions
Note: Actual performance may differ as a result of end-user environment and application. Specifications subject to change without notice.

®
BACnet is a registered trademark of ASHRAE. ASHRAE does not endorse, approve or test products for compliance with ASHRAE standards. Compliance of listed products to the requirements of ASHRAE Standard 135 is the responsibility of BACnet International (BI). BTL is a registered trademark of BI.

Patents: - US9819544B2 - EP3250970B1 - EP3139697B1 - US9924243B2

- US10073423B2 - US9608538B2 - CA2971061A1

Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com/nlight © 2014-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/30/23

NECY 1 of 4

ORDERING INFORMATION
NECY

Series nECY nLight ECLYPSE

Voltage
MVOLT 120-277VAC 347 120-277VAC, 347VAC

BACnet
[blank] Not Enabled BAC BACnet/IP & MS/TP Enabled

AutoDR
[blank] Not Enabled ADR Open ADR VEN

Example: NECY MVOLT BAC ENC
Visualization Software [blank] Not Enabled SVS 1 Envysion

Cellular Modem
[blank] No Cellular Modem REM 5 Prewired CLAIRITYTM Link router with
cellular SIM REMR 2,5 Prewired CLAIRITYTM Link router with
cellular SIM and cloud-toggleable relay

Enclosure ENC NEMA Type 1
metal enclosure

Wi-Fi Adapter
[blank] Includes Wi-Fi Adapter NW No Wi-FI Adapter Included

Options

[blank] SEP GFXK 3
AIR 4

None Single Ethernet Port Touchscreen interface (model nGWY2 GFX, mounted separately), PS 150 power supply, CAT5 cable Includes NECYD NLTAIR G2

ACCESSORIES

nECY ENC
nECYD NLTAIR G2 nECYREPL INTF

NEMA 1 Enclosure and pre-mounted 120-277VAC input, 24VDC output (Max 50W) power supply nLight AIR wireless adapter nLight Interface module (introduces 750 device limit if added to an ECLYPSE with AIR option)

Notes
1. Requires BACnet option.
2. Cloud-toggleable relay is prewired and intended to powercycle the nLight ECLYPSE remotely.
3. If 347 voltage option is selected, includes PS150 347.
4. AIR option supports 150 devices. RJ45 ports for connecting nLight wired devices are not available with the AIR option. GFXK option is not available with AIR option.
5. 347 option is required for cellular connectivity in Canada. MVOLT versions will support connectivity in the United States and Mexico only. Active connectivity plan required for cellular connectivity. All routers ship with 12-months Ethernet connectivity enabled. See CLAIRITY Link router specification sheet for more information.
6. Cellular connectivity performance may be affected by carrier coverage and antenna placement. Coverage by supported carriers should be verified prior to purchase.
7. See the Specifications section for a list of all supported carriers per country. 8. Use of default SIM included with hardware is required for REMCONN CELL connectivity plan. REMCONN ETH
does not require use of a cellular SIM but is required for connectivity with the portal using a non-standard, third-party SIM, provided by, paid for, and maintained by others. Compatibility with non-default, third party SIMs is not guaranteed or warranted.

CONNECTIVITY PLANS
Remote support via the CLAIRITY Link solution is enabled through a connectivity plan (REMCONN). Purchase of a CLAIRITY Link router includes an initial 12-month Ethernet connectivity plan that begins upon shipment of hardware from the factory. For extended periods of connectivity, or for cellular connectivity, supplementary plans can be purchased. Flexible plans are offered in 3-month to 24-month durations and can be purchased at any time.
FEATURES · Flexible connectivity periods offer affordable, connected assistance from nLight technical experts · With no hidden fees and no continuous costs, CLAIRITY Link connectivity is an on-demand service that can be purchased at any time · On-premise systems continue to operate when a connectivity plan is inactive · Optional service plans affordably supplement the ability to remotely connect, adding comprehensive programming, sustainment, and preventative maintenance options

Example: REMCONN ETH 24MO CAR1

Series REMCONN Connectivity plan to
enable remote access by factory representatives

Connection Type
ETH Uses Ethernet connection to a customer-provided network with Internet access for communication with the CLAIRITY Link portal
CELL 6,7,8 Includes a cellular plan to supplement or replace Ethernet connectivity for communication with the CLAIRITY Link portal

Service Length

3MO 6MO 9MO 12MO 18MO 24MO

3-month length 6-month length 9-month length 12-month length 18-month length 24-month length

Supported Countries CAR1 US, Mexico, and Canada

Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com/nlight © 2014-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/30/23

NECY 2 of 4

SPECIFICATIONS

Control Module Microprocessor: Single core 1.0 GHz Sitara ARM processor Size: 4.74" H x 3.57" W x 2.31" D (12.03 cm x 9.07 cm x 5.86 cm) Mounting: DIN rail mounted
nLight ECLYPSE Assembly Size: 4.74" H x 14.76" W x 2.43" D (12.03 cm x 37.5 cm x 6.16 cm)
Ports: Ethernet: (2) switched RJ-45 Ethernet ports USB Connections: 2 x USB 2.0 ports RS-485 Serial Communications: Screw terminals (Used for either BACnet MS/TP Subnet: RJ-45
Real Time Clock (RTC): Real Time Clock with rechargeable battery. Supports SNTP network time synchronization
RTC Battery: 20 hours charge time, 20 days discharge time. Up to 500 charge / discharge cycles
Enclosure: FR/ABS UL94-V0 flammability rating Environmental: Operating Temperature: 32°F to 122°F
(0 to 50°C) Storage Temperature: -22°F to 158°F (-30 to 70°C) Relative Humidity: 0 to 90% non-condensing Ingress Protection Rating: IP20 Security: FIPS Publication 140-2, Level 1 Compliant Complies with California Civil Code Title 1.81.26, Security of Connected Devices, approved under Senate Bill No. 327 (2018)
nLight Network Interface Module Size: 4.74" H x 3.20" W x 2.31" D (12.03 cm x 8.12 cm x 5.86 cm)
Mounting: DIN rail mounted Ports: 3 nLight bus ports (RJ-45)
nLight Bus Power Output: 0mA per port

Power Supply Module (24V) Size: 24V: 4.74" H x 2.85" W x 2.31" D (12.03 cm x 7.24 cm x 5.86 cm)
Operating Voltage: 24V: 24VAC/DC; ±15%; Class 2 Output Voltage,
Rated Current & Power: 24V: 18VDC regulated, 0-1.6A, 30W max

Enclosure

Type: NEMA 1 rated surface mount screw cover Size: 14.25"H x 14.25"W x 4.00"D (36.20cm x
36.20cm x 10.16cm) Rating: UL 2043 (Plenum) Rated

CLAIRITY Link Router Size: 2.92"H x 3.27"W x 0.99"D (74mm x 83mm x 25mm)
Power Consumption: < 6.5W Input Voltage Range: 9-30VDC
Mobile: 4G LTE - up to 150Mbps 3G - up to 42Mbps 2G - up to 236.8kbps United States - ATT, T-Mobile/Sprint, US Cellular, Alaska Wireless Mexico - Telefonica Canada - Tellus, Bell, SaskTel6
Ethernet: WAN - 10/100Mbps; connects to an ownerprovided, Internet-connected network. May be used for nLight ECLYPSE controller discovery on the same network. LAN-10/100Mbps; used for discovery of nLight ECLYPSE controllers that are connected to a network without Internet connectivity Wireless Mode - IEEE 802.11b/g/n Security - WPA2-Enterprise Wi-Fi Hotspot - used for modem and SIM diagnostics Wi-Fi Client - not supported
Environmental: Operating temperature - -40C to 75C Operating humidity - 10% to 90% noncondensing Storage temperature - -45C to 75C
Security: Firewall - pre-configured firewall Attack Prevention - DDOS prevention, port scan prevention
WEB filter - whitelist for specifying allowed sites only Access control - control of TCP, UDP, ICMP packets, MAC address filter Complies with California Civil Code Title 1.81.26, Security of Connected Devices, approved under Senate Bill No. 327 (2018) Ingress Protection IP30 Regulatory FCC, IC/ISED, EAC, RCM, PTCRB, RoHS, CE/RED, WEEE, Wi-Fi Certified, CCC, Anatel, GCF, REACH, Thailand NBTC, Ukraine UCRF, SDPPI (POSTEL) Antennas: Mobile - 698-960/1710-2690 MHz, SMA male connector Wi-Fi - 2400-2483.5 MHz, SMA male connector Input/Output Input - 1x digital, non-isolated input (on 4 pin power connector) Output - 1 x digital, open collector output (30 V, 300 mA, on 4 pin power connector) SIM 1 x SIM slot (Mini SIM ­ 2FF), 1.8V/3V, external SIM holder Dimensions 83 x 25 x 74 mm

COMMUNICATION
Ethernet Connection Speed: 10/100 Mbps Internet Protocol: IPv4 BACnet Profile: BACnet Building Controller (B-BC) BACnet Listing: BTL, B-BC
BACnet Interconnectivity: BBMD forwarding capabilities BACnet/IP to BACnet MS/TP routing
BACnet Transport Layer: MS/TP & IP (optional) Web Server Protocol: HTML5
Web Server Application Interface: REST API

Supported BACnet MS/TP Connectivity:
· 1 x RS-485 serial communications port for BACnet MS/TP · RS-485 EOL Resistor ­ Built-in · RS-485 Baud Rates ­ 9600, 19200, 38400, or 76800 bps
Supported Wireless Connectivity:
· Wireless Adapter ­ USB Port Connection · Wi-Fi Communication Protocol ­ IEEE 802.11b/g/n · Wi-Fi Network Types ­ Client, Access Point, Hotspot

Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com/nlight © 2014-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/30/23

NECY 3 of 4

SYSTEM ARCHITECTURE
The nLight ECLYPSE serves as the backbone for nLight and nLight AIR digital lighting networks. The nLight ECLYPSE provides networked devices with schedule management and remote software programming via SensorView web-based software. The backbone also provides support for system-wide controls such as master override switches, automated demand response, and BACnet integration. One nLight ECLYPSE is capable of handling up to 750 total devices and up to 128 global channels for the entire network. The nLight ECLYPSE is also compatible with other Distech ECLYPSE products, offering a full suite of BAS capabilities.

EXAMPLE NLIGHT ECLYPSE NOMENCLATURE AND OPTIONS

Example Nomenclature

Connection to Wired Devices

Maximum of 150 Wireless Devices

NECY MVOLT ENC
NECY MVOLT ENC +
NECYD NLTAIR G2
NECY MVOLT ENC AIR
NECY MVOLT ENC AIR +
NECYREPLY INTF

No Wired Interface Module

No AIR Adapter Not Limited at 150
Not Limited at 150

Maximum of 750 Wireless Devices
No AIR Adapter
Reduced Capability

All License Options Available (BAC, SVS, SVEA)

Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com/nlight © 2014-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/30/23