Blink HQ 200 – Level 2 AC EVSE Installation Manual
Version 1.0
Important Safety Instructions
Before installing or using the Blink Electric Vehicle Supply Equipment (EVSE), read all instructions, paying particular attention to WARNING and CAUTION markings. Review any instructions included with your electric vehicle (EV) for vehicle charging. The following symbols and associated instructions are used throughout this document to avoid hazards:
Legend
- WARNING: RISK OF ELECTRIC SHOCK: Used when there is a risk of personal injury.
- WARNING: RISK OF ELECTRIC SHOCK: Used when there is a risk of electric shock.
- WARNING: RISK OF FIRE: Used when there is a risk of fire.
- CAUTION: Used when there is a risk of damage to the equipment.
General Safety Guidelines:
- This product should be installed only by a qualified approved technician.
- Blink is not responsible for physical injury, damage to property or equipment caused by the installation of this device.
- Ensure that pressure terminal connectors for field wiring connections are provided with instructions specifying a range of values or a nominal value of tightening torque for the clamping screws.
- Ensure that materials used and installation procedures follow local building codes and safety standards.
- The information in this manual does not exempt the user from the responsibility to follow all applicable codes or safety standards.
- Review this manual carefully and consult with a licensed contractor, licensed electrician, or trained installation expert to ensure compliance with local building codes and safety standards.
Repair and Maintenance Clause
- Only a licensed contractor, licensed electrician, or trained installation expert is allowed to repair or maintain this device. General users are forbidden from repairing or maintaining this device.
- Any repair or maintenance MUST be performed after removing power from this device.
Moving and Storage Instructions
- Store the product at a temperature between -40 and +80 °C.
- Check product for damage after moving.
- Carry the product by the sides. Do not lift or carry by the flexible cord or the EV cable.
FCC Rules and Industry Canada License-Exempt RSS Standard(s)
- This device complies with Part 15 of the FCC Rules. Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment.
- English: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
- French: Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
WARNING: RISK OF ELECTRIC SHOCK
Basic precautions should always be followed when using electrical products:
- Read all instructions before using this product.
- This device should be supervised when used around children.
- Do not put fingers into the EV connector.
- Do not use this product if the flexible power cord or EV cable is frayed, has broken insulation, or any other signs of damage.
- Do not use this product if the enclosure or the EV connector is broken, cracked, open, or shows any other indication of damage.
WARNING: RISK OF ELECTRIC SHOCK
Improper connection of the equipment grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded.
- Do not touch live electrical parts.
- Incorrect connections may cause electric shock.
WARNING: RISK OF ELECTRIC SHOCK
This equipment is intended only for charging vehicles that do not require ventilation during charging. Please refer to your vehicle's owner's manual to determine ventilation requirements.
WARNING
Do not use extender cables to increase the length of the charging cable. The maximum length is limited to 25 feet by the National Fire Protection Agency.
CAUTION
To reduce the risk of fire, connect only to a circuit provided with Model HQW2-50C-W1-N1-N-23, HQW2-50C-N1-N1-N-23, HQW2-50C-W1-N2-N-23-D for 50 A; Model MQW2-50C-M2-R1-N-23, HQW2-50C-W1-N1-N-23, HQW2-50C-N1-N1-N-23, MQW2-50C-M2-R2-N-23-D, HQW2-50C-W1-N2-N-23-D for 62.5 A amperes maximum branch circuit overcurrent protection in accordance with the National Electrical Code, ANSI/NFPA 70 and the Canadian Electrical Code, Part I, C22.1.
General Conventions: The use of the word “Note:” indicates additional information relevant to the current process or procedure.
Introduction
This INSTALLATION MANUAL describes how to properly install the Blink HQ 200 – Level 2 AC EVSE (Blink Product). Contact the Blink Support Center at (888) 998 2546 for troubleshooting assistance and additional technical questions. Unauthorized modification to the Blink product will void manufacturer's warranty.
The Blink Product specified in this document is designed for the North American market to charge plug-in electric vehicles (PEVs), plug-in hybrid electric vehicles (PHEVs), and battery electric vehicles (BEVs). It provides Level 2 AC charging that shortens the charging time for typical EVs, when compared to a Level 1 AC EVSE.
Product Overview
MODEL NAME | HQ 200 | HQ 200 Smart |
---|---|---|
MODEL NUMBER | HQW2-50C-N1-N1-N-23 | HQW2-50C-W1-N1-N-23 HQW2-50C-W1-N2-N-23-D |
PART NUMBER | 01-0200 | 01-0201 01-0204 |
PRODUCT VIEW | A black, rectangular EV charging station with a coiled charging cable and connector. The Blink logo is visible on the front. |
A black, rectangular EV charging station with a coiled charging cable and connector. The Blink logo is visible on the front. |
Product Specifications
POWER SPECIFICATIONS
HQ 200 | HQ 200 Smart | |
---|---|---|
Maximum Power | < 2.6 W | 12 kW |
Standby Power | < 3.6 W | |
Output Power | NEMA 14-50P: 2.9, 3.8, 5.8, 7.7, 9.6 kW Hardwired: 2.9, 3.8, 5.8, 7.7, 9.6, 11.5, 12 kW |
N/A |
Output Amperage | NEMA 14-50P: 12, 16, 24, 32, 40 A Hardwired: 12, 16, 24, 32, 40, 48, 50 A |
N/A |
Circuit Breaker Options | NEMA 14-50P: 15, 20, 30, 40, 50 A Hardwired: 15, 20, 30, 40, 50, 60, 70 A |
N/A |
Voltage | 208/240 VAC | |
Voltage Range | 180 to 264 VAC | |
Frequency | 50, 60 Hz | |
Input Wiring Type | NEMA 14-50P (Default) Hardwired (Optional) |
|
Input Wiring Scheme | L1, L2, PE | |
Cold-Load Pickup | Randomized delay between 120 and 720 sec. before charge resumes after a power failure. | |
Power Measurement Accuracy | Embedded meter with a ±1% accuracy at the nominal input. | |
Surge Protection | Up to 6 kV at 3,000 A |
FUNCTIONAL SPECIFICATIONS
HQ 200 | HQ 200 Smart | |
---|---|---|
Charge Connector Type | SAE J1772, Lockable (up to 0.24" or 5mm Shackle Diameter) | |
Charge Cable Length | 23ft. (7.01m) | |
Demand Response | No | Yes |
Status Indicator | Status LED | Status & WLAN LEDs, Audio |
User Interface | None | Mobile Application |
Access Control | None | Client |
Local Load Management | None | 2.4 and 5 GHz Wi-Fi (802.11 b/g/n/ac) |
NETWORK SPECIFICATIONS
HQ 200 | HQ 200 Smart | |
---|---|---|
Wireless Local Area Network (LAN) | None | 2.4 and 5 GHz Wi-Fi (802.11 b/g/n/ac) |
Wide Area Network (WAN) | None | None |
SAFETY & COMPLIANCE SPECIFICATIONS
HQ 200 | HQ 200 Smart | |
---|---|---|
Ground Fault Detection | CCID20, 20 mA per UL 2231, Automatic Reset Feature and Manual Reset Feature | |
Ground Monitor | Ground Monitor per UL 2231 | |
Safety Compliance | UL and cUL, NEC Article 625, RoHS | |
EMC Compliance | FCC Part 15B, Industry Canada (IC), Norma Oficial Mexicana (NOM) | |
ADA Compliance | Yes | Yes |
ENERGY STAR Certified | Yes | Yes |
OPERATIONAL SPECIFICATIONS
HQ 200 | HQ 200 Smart | |
---|---|---|
Mounting Type | Wall Mount | |
Enclosure Rating | NEMA Type 3R Indoor/Outdoor | |
Operating Temperature | Up to 40 A: -30°C to +50°C (-22°F to +122°F), At 50A: -30°C to +45°C (-22°F to +113°F) | Up to 40 A: -30°C to +50°C (-22°F to +122°F), At 50A: -30°C to +45°C (-22°F to +113°F) |
Storage Temperature | -40°C to +80°C (-40°F to +176°F) | |
Operating Humidity | 5 to 95% Relative Humidity, Non-Condensing | |
Charger Dimensions | 11.65"H x 8.91"W x 4.02"D (296mm H x 226.2mm W x 102.2mm D) | |
Package Dimensions | 18.15"H x 14.80"W x 11.42"D (461mm H x 376mm W x 290mm D) | |
Charger Weight (Unpackaged) | 20.94lbs. (9.5kg) | |
Charger Weight (Packaged) | 23.15lbs. (10.5kg) |
Blink reserves the right to alter product offerings and specs at any time without notice and is not responsible for typographical or graphical errors that may appear in this document.
Pre-Installation Instructions
Safety and Grounding
Safety Check
CAUTION: DISCONNECT ELECTRICAL POWER PRIOR TO INSTALLING THE BLINK CHARGING STATION. FAILURE TO DO SO MAY CAUSE PHYSICAL INJURY OR DAMAGE TO THE ELECTRICAL SYSTEM AND BLINK PRODUCT.
The Blink Product should be installed only by a licensed contractor, and/or a licensed electrician in accordance with all applicable state, local and national electrical codes and standards.
Before installing the Blink Product, review this manual carefully and consult with a licensed contractor, licensed electrician and trained installation expert to ensure compliance with local building practices, climate conditions, safety standards, and state and local codes.
Use appropriate protection when connecting to the main power distribution cable. Use tools as outlined in the "Tools Required for Installation" section.
Grounding Instructions
This product must be connected to a grounded, metal, permanent wiring system; and an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the product.
Installation Instructions
Tools Required for Installation
Tools |
---|
Security Torx T20 Driver |
Wire Cutters |
Wire Strippers |
Torque Wrench |
Drill |
Drill Bits |
Slotted Screwdriver |
P3 Phillips Screwdriver |
Heat Shrink Tube |
Parts Required for Installation
Part | Quantity | Notes |
---|---|---|
HQ 200 or HQ 200 Smart Charger 50 A | 1 | Included |
Mounting Bracket | 1 | Included |
NEMA 14-50P Plug | 1 | Included |
Mounting Screws, Wood, 5/16" | 2 | Commercially Available |
Mounting Anchors, Masonry, 5/16" | 4 | Commercially Available |
Conduit Fitting, 1" | 1 | Commercially Available |
Conduit, 1" | As Needed | Commercially Available |
Wire Size and Temperature
Terminal | Wire Size | Temperature |
---|---|---|
L1/L2 | 6 AWG | 90 °C |
PE | 10 AWG | 90 °C |
Product Installation
STEP 1: Remove front cover screws.
STEP 2: Remove the front cover.
STEP 3: Remove the installation cover screws.
STEP 4: Remove installation cover.
Diagram showing an exploded view of the HQ 200 Charger with labels for M4 TORX SCREW (TOP COVER), TOP COVER, DIP SWITCH, M4 TORX SCREW (INSTALLATION COVER), and INSTALLATION COVER.
Diagram showing the internal components of the HQ 200 Charger with a DIP SWITCH labeled.
STEP 5: Set maximum current by configuring the DIP switch using the following table:
Current/Function | Circuit Breaker Specification | DIP switch | Figure | ||
---|---|---|---|---|---|
SW1 | SW2 | SW3 | |||
Firmware reset | N/A | OFF | OFF | OFF | Diagram showing DIP switch positions: 1-OFF, 2-OFF, 3-OFF |
12A | 15A | OFF | OFF | ON | Diagram showing DIP switch positions: 1-OFF, 2-OFF, 3-ON |
16A | 20A | OFF | ON | OFF | Diagram showing DIP switch positions: 1-OFF, 2-ON, 3-OFF |
24A | 30A | OFF | ON | ON | Diagram showing DIP switch positions: 1-OFF, 2-ON, 3-ON |
32A | 40A | ON | OFF | OFF | Diagram showing DIP switch positions: 1-ON, 2-OFF, 3-OFF |
40A (default) | 50A | ON | OFF | ON | Diagram showing DIP switch positions: 1-ON, 2-OFF, 3-ON |
WARNING: Power must remain off before changing the DIP switch.
STEP 6: Secure the main body mounting bracket to the wall with appropriate screws.
Follow applicable accessibility requirements for the mounting position. The unit shall be stored or located at a sufficient height above the floor. For an indoor site, it should be not lower than 18" (450 mm) and not higher than 4' (1.2m). For an outdoor site, it should be not lower than 24" (600 mm) and not higher than 4' (1.2m). Refer to Article 625, NEC.
The mounting bracket has six screw holes for wall mounting. If only two screws are used for mounting, the screws should pass through the middle two screw holes of the mounting bracket. The other screw holes are reserved for the user.
Diagram showing a mounting bracket with arrows indicating where M6 screws should be inserted for mounting.
Screw | Torque |
---|---|
M6 | 25 kgf.cm min 21.7 lb.-in min |
#12 | 25 kgf.cm min 21.7 lb.-in min |
A. For masonry walls, use M6 mechanical screws (commercially available).
B. For finished walls supported by wood studs, use #12 self-tapping screws.
C. Please refer to the following torque. The actual torque is according to the wall material.
Diagram showing the HQ 200 charger being attached to the mounting bracket with a locking screw.
STEP 7: Hang the product on the mounting bracket.
STEP 8: Slide down the product to rest on the bottom flange.
STEP 9: Install the locking screws (M4 Torx).
STEP 10: Reassemble the install cover and front cover with M4 screws.
Charging Status Indicators
Diagram showing the front of the Blink HQ 200 charger with a circular LED Status Indicator highlighted.
LED Indicator | Description | Definition |
---|---|---|
Black circle |
Not Illuminated | Power Off |
Green circle |
Green Steady | Ready |
Light green circle |
Green Flashing | Flashing Green (Fast): Authorized, wait for EV Connect Flashing Green (Slow): Suspend (Occupying) |
Light blue circle |
Blue Flashing | Flashing Blue (Slow): Charging |
Red circle |
Red Steady | Unrecoverable Fault |
Pink circle |
Red Flashing | Recoverable Fault |
Magenta circle |
Pink Steady | Reserved (from OCPP Service) |
Yellow circle |
Yellow Steady | Power On / Device Unavailable |
Light yellow circle |
Yellow Flashing | Booting / Firmware Upgrading / Out of Service |
File Info : application/pdf, 15 Pages, 9.08MB
DocumentDocumentReferences
EV Charging Stations for Residences & Businesses | Blink Charging
Blink Charging: Electric Vehicle (EV) Charging Stations (EVSE)
EV Charging Stations for Residences & Businesses | Blink Charging
Related Documents
![]() |
Blink MQ 200 Level 2 AC EVSE Instruction Manual Comprehensive instruction manual for the Blink MQ 200 Level 2 AC EVSE, covering installation, operation, safety, and specifications for electric vehicle charging. |
![]() |
Blink Series 7 Model 780 & Series 8 Model 880 EV Charging Station Product Manual Official product manual for Blink Series 7 Model 780 and Series 8 Model 880 electric vehicle charging stations. Covers installation, specifications, safety, operation, and troubleshooting for EVSEs. |
![]() |
UK PSTI Statement of Compliance for Blink Products This document outlines the UK PSTI Statement of Compliance for various Blink products, including the Blink Sync Module Core, Blink Mini 2, Blink Outdoor Camera 4, Blink Video Doorbell, Blink Outdoor 3, Blink Indoor 3, Blink Mini, and Blink Sync Module 2. It details their model numbers, device codes, and defined support periods, confirming conformity with UK statutory requirements. |
![]() |
Blink HQ 150 Residential EV Charger - Fast and Reliable Home Charging Learn about the Blink HQ 150, a 32 Amp residential EV charger offering fast, reliable, and sleek home charging. Features include a slim design, durable construction, and compatibility with all EVs using an SAE J1772 connector. |
![]() |
Blink Series 9 - Model 9030 DC Fast Charger Product Manual Comprehensive product manual for the Blink Series 9 30kW DC Fast Charger, Model 9030, detailing installation, operation, maintenance, and specifications for electric vehicle charging in commercial and public environments. |
![]() |
Blink Mini Smart Security Camera: Features, Setup, and FAQ Comprehensive guide to the Blink Mini indoor HD security camera, covering features, specifications, setup instructions, and frequently asked questions. Learn about motion detection, two-way audio, and app integration. |
![]() |
Blink Smart Security Devices: Safety, Compliance, and Warranty Information Comprehensive safety, compliance, and limited warranty information for Blink Floodlight Mount, Blink Outdoor, and Blink Sync Module 2 devices from Amazon. |
![]() |
Blink Outdoor 4 (two-cam) + Sync Module Core Product Sustainability Fact Sheet A sustainability fact sheet for the Blink Outdoor 4 (two-cam) + Sync Module Core, detailing its carbon footprint, materials, manufacturing, transportation, product use, and end-of-life considerations. It highlights the product's use of recycled materials, energy-efficient design, and trade-in/recycling options. |