Model PVSC
POWER VECTOR SECURITY COVER
Description
The Power Vector Security Cover (PVSC) provides protection against tampering. The system settings of a Power Vector amplifier are protected from accidental tampering while still leaving the power and meter switches accessible. It also provides for access to any desired input volume control knobs via break-off sections.
Installation
Note: If access to any of the input volume control knobs is desired, be certain to remove the break-off sections of the PVSC prior to its installation (see below).
- Line up the PVSC to the front panel of the Power Vector amplifier using the screw holes as a guide.
- Attach the PVSC to the amplifier using the three screws provided.
Diagram showing the front panel layout. It features a row of circular openings, with labels indicating "Screw holes (x2)" on the left side and a "Screw hole" on the right side. Some of the circular openings are marked as "Break-off piece".
Break-offs
Using a thin, flathead screwdriver, insert the screwdriver head into the center of the break-off piece and twist. If necessary, use a knife or file to take off any sharp edges after removal.
CAUTION: The break-off piece can fly off while twisting and become a hazard. Take reasonable precautions to prevent any flying pieces from causing injury.
Illustrations showing the removal of a break-off piece. The first image depicts a screwdriver inserted into the center of a break-off piece, ready to twist. The second image shows the piece being twisted and detached, with an arrow indicating the rotational motion.