SolarEdge Power Optimizer Inter-Compatibility Technical Note

Version History

  • Version 17 (February 2023) – Updated compatibility for S-Series Power Optimizers and editorial updates.
  • Version 16 (February 2023) – Updated compatibility for commercial S-series Power Optimizers.
  • Version 15 (November 2022) – Updated compatibility of OP250LV and OP300LV, with P401.
  • Version 14 (August 2022): Updated compatibility options and compatibility definitions.
  • Version 13 (July 2022) – Specified compatibility options.
  • Version 12 (June 2022) – Updates for commercial Power Optimizer compatibility, P1101 and P860/P960.
  • Version 11 (May 2022) – Added note about SolarEdge Sense Connect; added note about a retrofit installation or an RMA replacement.

This technical note specifies the inter-compatibility between SolarEdge Power Optimizers of the S-series and the P-series. It also specifies the inter-compatibility of P-series power optimizers with earlier series power optimizers (PBxxx and OPxxx) and S-series service part numbers (Sxxx-R).

NOTES

  • Inter-compatibility refers exclusively to the installation of power optimizers in the same PV-string.
  • All optimizers installed within the same PV-string must be inter-compatible, as specified in compatibility tables 2 and 3.
  • For the purposes of this document, a single PV-string refers to power optimizers connected to each other using output cables to form a string.

Guidelines for Replacing Power Optimizers

When replacing a power optimizer, the replacement power optimizer must be compatible with the other power optimizers in the string. Follow these guidelines:

General

Installing different series and models of power optimizers in the same installation is permitted as long as they are installed in separate PV-strings. However, power optimizers that are inter-compatible can be installed in the same PV-string.

When replacing a Power Optimizer, always check with the SolarEdge Designer if the power, current, and voltage specifications of the PV panel are compatible with the specifications of the replacement Power Optimizer. Ensure that the panel's Voc (at minimum ambient temperature) does not exceed the maximum input voltage of the replacement Power Optimizer. Use the SolarEdge Designer to quickly validate electrical compatibility. Refer to the Power Optimizer datasheet for details.

P-Series and S-Series Compatibility

Avoid installing P-series and S-series Power Optimizers in the same PV-string in existing installations.

In the case of replacement or addition to an existing installation, mixing P and S-series is permitted under the following conditions:

  • Any P-Series power optimizer that is compatible with the P401 power optimizer is also compatible with the S440 and S500 power optimizers.
  • Any P-series power optimizer that is compatible with the P505 power optimizer is also compatible with the S500B power optimizers.
  • Any P-Series power optimizer that is compatible with the P950 power optimizer, is also compatible with the S1000 power optimizer.

When replacing P-series Power Optimizers with S-series Power Optimizers, ensure the inverter's firmware version is updated as follows:

  • For inverters with LCDs – minimum required version is 3.2537.
  • For SetApp-compatible inverters – minimum required version is 4.8.xx.

Inter-compatibility Tables

These tables describe the Power Optimizer series and models that can be installed in the same PV-string, during installation or when a Power Optimizer is replaced. If a cell contains a checkmark, the relevant Power Optimizers can be installed in the same string.

Table 2a: S-Series Power Optimizer Inter-compatibility Tables (Residential)

S440S500S500BS650B
S-series S440
S-series S500
S-series S500B
P-series P400
P-series P500
P-series P401
P-series P404/P485/P505
P-series P601

Table 2b: S-Series Power Optimizer Inter-compatibility Tables (Commercial)

S1000S1200S1201
S-series S1000
S-series S1200
S-series S1201
P-series P850/950
P-series P860/P960/P1100/P1101Not inter-compatible with S-Series

NOTES

  • Support for all phased-out P-series power optimizer models via SolarEdge Support will continue with a compatible replacement as long as stock lasts, followed by replacement with compatible S-series service part numbers.
  • In the case of a retrofit installation or RMA replacement, you may need to combine P-series and S-series on the same string. This requires an extension cable. See Using Extension Cables and Adapter Cables with Power Optimizers.
  • SolarEdge SenseConnect technology does not work if P-series and S-series Power Optimizers are installed in the same PV-string.

Table 3: P-Series Power Optimizer Inter-compatibility

This table describes the P-Series Power Optimizer series and models that can be installed in the same PV-string, during installation or when a Power Optimizer is replaced. If a cell contains a checkmark, the relevant Power Optimizers can be installed in the same string.

P-seriesP300P320P340P350P370P370TP375P395P400P401P404P405 **P485P500P505P600P601P605P650P700P701P730P800p **P801P850 ***P860 *P950P960 *P1100P1101 *
P300
P320
P340
P350
P370
P370T
P375
P395
P400
P401
P404
P405 **
P485
P500
P505
P-serie P600
P601
P605
P650
P700
P701
P730
P800p **
P801
P850 ***
P860 *
P950
P960 *
P1100
P1101 *

Table on Page 5: Compatibility with Other Series

This table shows compatibility between various series and P-series Power Optimizers.

SeriesP300P320P340P350P370P370TP375P395P400P401P404P405P485P500P505P600P601P605P650P700P701P730P800pP801P850P860P950P960P1100P1101
OP250-LV
OP300-LV
OP300-MV
OP350-LV
OP350-MV
OP-serie OP400-MV
OP400-EV
OP480
OP500-IV
OP600-96
PB250-AOB
PB-PB350-AOB
PB350-TFI
Module OP250-LV (embedded)
PB250-CSI
OPJ300-LV

Remarks:

  • P860 and P960 can be replaced by the P1101. Note that the P1101 cannot be replaced by the P860/P960.
  • For P405, P485, and P800p, the same replacement options apply for both single and dual input versions.
  • P850 has replaced P800s. They can be used interchangeably and connected in the same string.
  • M-series power optimizers M2640 and M1600 cannot be used interchangeably and cannot be connected to another Power Optimizer in the same string.

File Info : application/pdf, 5 Pages, 147.02KB

PDF preview unavailable. Download the PDF instead.

compatibility-solaredge-power-optimizers-s-serie

References

GPL Ghostscript 9.55.0

Related Documents

Preview SolarEdge Residential Power Optimizer Inter-Compatibility Technical Note
This technical note from SolarEdge details the inter-compatibility guidelines for residential Power Optimizers, covering S-Series, P-Series, and R-Series models for both new installations and RMA (Return Material Authorization) purposes. It provides compatibility tables and essential notes for installers and technicians.
Preview SolarEdge Power Optimizer Inter-Compatibility Application Note
This application note from SolarEdge details the inter-compatibility between various SolarEdge Power Optimizer series, including S-series, P-series, OP-series, PB-series, and M-series, for residential installations. It provides essential compatibility tables and guidelines for replacing Power Optimizers to ensure system integrity and warranty compliance.
Preview SolarEdge S-Series Power Optimizer Specifications and Connections
Technical application note detailing the specifications, features, and connection guidelines for SolarEdge S-Series Power Optimizers, including comparisons with P-Series models like S440, P401, S1200, and P1100.
Preview SolarEdge Power Optimizer S440, S500, S500B Datasheet
Datasheet for SolarEdge Power Optimizers S440, S500, and S500B, designed for residential PV installations. Highlights features like module-level optimization, safety shutdown, superior efficiency, and compatibility with SolarEdge inverters.
Preview SolarEdge Product Waiver Approval - RFW-001246
Official product waiver approval from SolarEdge for specific inverter and optimizer configurations, detailing approved designs and conditions for installations in Europe.
Preview SolarEdge Product Waiver Approval for S500B and S650B Power Optimizers
Official waiver approval from SolarEdge for specific configurations of S500B and S650B Power Optimizers in European installations, detailing approved parameters and warranty conditions.
Preview SolarEdge Installation Guide: Comprehensive Setup and Operation
Detailed installation guide for SolarEdge power harvesting systems, covering inverters, power optimizers, safety instructions, and system commissioning for optimal solar energy production.
Preview SolarEdge Product Waiver Approval for S440 Power Optimizers
Official waiver approval from SolarEdge for the use of S440 Power Optimizers with specific PV modules, detailing conditions and warranty implications.