Datasheet for OXBOX models including: J801X Series High Efficiency Upflow-Horizontal and Downflow Gas Furnaces, J801X Series, High Efficiency Upflow-Horizontal and Downflow Gas Furnaces, Upflow-Horizontal and Downflow Gas Furnaces, Downflow Gas Furnaces, Gas Furnaces, Furnaces
OxBox 54,000 Btu 80% Afue Single-Stage Gas Furnace (ECM Motor)
OxBox 90,000 Btu 80% Afue Single-Stage Gas Furnace (ECM Motor) 21" Wide
File Info : application/pdf, 8 Pages, 680.53KB
DocumentDocumentTECHNICAL SPECIFICATIONS J801X* Series High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80+% AFUE Input 45,000 - 126,000 BTUH The high efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing "appliance appearance." Design certified by CSA for application in Canada and the United States. FEATURES and BENEFITS · 100% fired and tested: All units and each component are tested on the manufacturing line. · Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install. · Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life. · 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds). · 30 second post purge: Increases life of heat exchanger. · Hot surface igniter: Innovative application of a silicon nitride igniter. · High static blowers: All models equipped with high static blowers. · 90 second cooling cycle blower-off delay (TDR): Increases cooling performance. · Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances. · High efficiency blower kits: Maximize efficiencies. On select units, a SEER improvement of up to 1 point is realized. · Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra easy motor speed selection. · LP convertible:Simple burner orifice and regulator spring change for ease of convertibility. · Integrated control board: Incorporates connections for electronic air cleaner and humidifier. · Two piece door design: Enhances furnace appearance and uses captured screws to prevent loose door screws. · Meets Title 24 Standards: Min. 350 CFM/Ton, .58 watts/ CFM and 2% cabinet leakage. For California installations in SCAQMD and SJVAPCD only: This furnace does not meet the SCAQMD Rule 1111 and SJVAPCD Rule 4905 NOx emission limit (14 ng/J). This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com. GAS FURNACE COMPONENTS 9 4 1. Blower Assembly 12 7 2. Blower Door Switch 11 13 14 3. Burner Assembly 5 8 4. Control Board 6 2 5. Flame Sensor 3 6. Gas Manifold 1 Upflow/Horizontal Gas Furnace 7. Gas Valve 8. Igniter Combustion Tube 4 9. Inducer 1 11 10. Insulated Combustion Tube 2 (Downflow Models) 13 10 11. Low Voltage Transformer 9 7 12. Main Air Limit Switch 12 5 13. Pressure Switch 14 6 14. Roll-Out Switch(s) 8 3 2 DIMENSIONS J801X*U Model #'s 045AU 054AU 072BU 090BU 072CU 090CU 108CU 126DU Dimension "A" Dimension "B" Dimension "C" Dimension "D" 14 1/4 10 3/4 12 5/8 12 7/8 17 1/2 11 3/4 15 7/8 16 1/8 21 24 1/2 14 15 1/4 19 3/8 22 7/8 19 7/8 23 1/8 TOP VIEW C 23 FLANGES 19 BOTTOM VIEW D Front Brace Bottom Panel 23 1/2 25 3/8 Electric (Ø 7/8) 4 Knockouts (both sides) 1 1/4 23 LEFT SIDE B Accepts 4" Type B Vent Pipe A Gas (1 5/8 X 3 1/2) T-stat (Ø 7/8) Electric (Ø 7/8) 23 15 1 FRONT VIEW 22 1/4 25 21 3/4 (1 Gas 5/8 X 3 1/2 X 45°) 28 RIGHT SIDE J801X*U Series Upflow/Horizontal Furnace 29 1/2 22 1/2 22 3/4 34 1/2 3 DIMENSIONS continued J801X*D Model #'s 054AD 072BD 090BD 108CD 126DB Dimension "A" Dimension "B" Dimension "C" Dimension "D" 14 1/4 10 3/4 12 5/8 12 7/8 17 1/2 11 3/4 15 7/8 16 1/8 21 24 1/2 14 15 1/4 19 3/8 22 7/8 19 5/8 23 1/8 TOP VIEW C 23 FLANGES 19 BOTTOM VIEW D Front Brace 18 5/8 Electric (Ø 7/8) Gas (1 5/8 X 3 1/2) 25 3/8 7 28 LEFT SIDE B Accepts 4" Type B Vent Pipe A T-stat (Ø 7/8) Electric (Ø 7/8) 22 1/4 25 Gas (1 5/8 X 3 1/2 X 45°) 29 1/2 22 1/2 7 FRONT VIEW J801X*U Series Downflow Furnace RIGHT SIDE 34 1/2 22 1/2 4 MODEL IDENTIFICATION CODE J 80 1 X 072 B U 3 S Brand Model Family 80 = 80% AFUE 90 = 90% AFUE 95 = 95% AFUE 96 = 96% AFUE Gas Valve Stages 1 = 1 Stage Gas Valve 2 = 2 Stage Gas Valve M = Modulating Stage Gas Valve NOx Digit S = Standard T = 40 Ng/J NOx L = 14 Ng/J NOx Nominal Cooling Airflow 3 = 3 Tons 4 = 4 Tons 5 = 5 Tons V = Variable Blower Type P = PSC Motor E = ECM Motor X = X13 Constant Torque Motor V = Variable Speed Motor (Constant CFM) Input BTUH 045 = 45,000 054 = 54,000 072 = 72,000 090 = 90,000 108 = 108,000 126 = 126,000 Cabinet Width A = 14.5" B = 17.5" C = 21.0" D = 24.5" Orientation U = Upflow / Horizontal Left / Horizontal Right D = Downflow M = Multi-position SPECIFICATIONS J801X*U MODEL NUMBERS Input - BTUH Heating Capacity - BTUH AFUE Motor H.P. - Speed - Type Motor FLA Rated Ext. SP - In. W.C. Temperature Rise Range - F Shipping Weights (lbs) 045AU 45,000 36,000 80.0 1/2 - 5 - ECM 6.4 0.5 30-60 95 054AU 54,000 43,200 80.0 1/2 - 5 - ECM 6.4 0.5 30-60 95 072BU 72,000 57,600 80.0 3/4 - 5 - ECM 8.8 0.5 30-60 110 090CU 90,000 72,000 80.0 3/4 - 5 - ECM 8.8 0.5 35-65 134 108CU 108,000 86,400 80.0 1 - 5 - ECM 11.5 0.5 35-65 136 126CU 126,000 100,800 80.0 1 - 5 - ECM 11.5 0.5 40-70 147 J801X*D MODEL NUMBERS 054AU 072BD 090BD Input - Btuh (a) 54,000 72,000 90,000 Heating Capacity - Btuh AFUE Motor H.P. - Speed - Type 43,000 80.0 1/2 - 5 - ECM 58,000 80.0 3/4 - 5 - ECM 72,000 80.0 3/4 - 5 - ECM Motor FLA 6.4 8.8 8.8 Rated Ext. SP - In. W.C. 0.5 0.5 0.5 Temperature Rise Range - F 30-60 35-65 35-65 Shipping Weights (lbs) 102 110 115 5 ACCESSORIES J801X*U AND J801X*D KITS Description "A" Cabinet downflow sub base kit "B", "C", "D" Cabinet downflow sub base kit U.S. LP Conversion kit (0 to 10,000 ft.) Bottom return filter 20 per box, "A" cabinet Bottom return filter 20 per box, "B" cabinet Bottom return filter 20 per box, "C" cabinet Bottom return filter 20 per box, "D" cabinet Side return filter kit Furnace Twinning Kit SKU 902974 904911 904914 903088 904916 904917 904918 541036 1010035 6 7 Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (07/2022) 585F-0722 (Replaces 585F-0420)