SY Pro Ice Bath Chiller User Manual
Model: SY Pro
Important Safety Information
CAUTION!
- Operators must be 18 years or older.
- Avoid using the chiller with wet hands.
- Keep the power cord away from heavy objects and do not run it under carpets.
- Do not insert objects into the chiller's vents or openings.
- Exercise caution around children, the elderly, and those with mobility issues.
- Always keep the chiller upright and on a stable, level surface; do not invert.
- Install the chiller in well-ventilated areas (at least 100cm of clear space around vents for airflow), avoiding closets or cabinets and keeping vents clear of obstructions.
- Do not disassemble or modify the chiller.
- Avoid using in very humid or dusty conditions.
- For electrical issues, contact authorized service personnel.
- Keep pets and children away during operation.
- Report any sign of damage, leaking, strange noises, smells, or performance issues immediately.
- Disconnect power before maintenance or cleaning.
- Avoid placing the chiller in direct sunlight or near heat sources.
- Ensure the filter is installed when the chiller is working.
- Regularly clean the water filter and dust net for optimal efficiency.
- If the ambient temperature drops to 0 °C (32°F), disconnect the pipes and open the drainer to FULLY drain all water from the chiller to prevent freezing damage.
▲ Electricity is very dangerous, in order to prevent accidents or death please pay attention to safety.
- During and after transportation, the chiller must stay upright on a stable surface at all times.
- After transportation and before use, the chiller must be left for 24hrs for the refrigeration gas to settle.
- Make sure the chiller is plugged into an AC socket or extension cable that is suitable for use.
- Ensure the chiller is kept dry at all times, do not immerse, splash or spray the unit with water. If the unit does get wet, unplug it immediately and do not use.
- Never leave the chiller switched on when in the water, always ensure the unit is switched off during your cold water therapy session.
- If the chiller stops working or doesn't work when switched on, unplug it immediately and do not use.
We accept no responsibility for misuse or failure to use this equipment safely as instructed.
Working Temperature: 1°C-45°C (34°F -113°F)
Storage Temperature (No water inside the chiller): -20°C-55°C (-4°F -131℉)
Storage Relative Humidity: 20%-85%
Product Overview and Components
The SY Pro Ice Bath Chiller is designed for both indoor and outdoor use, providing efficient cooling for your ice bath experience.
Quick Start Guide
- Place the chiller on a stable surface near your ice bath tub.
- Connect both the Inlet and Outlet water pipes, ensuring the valves are hand-tight.
- Fill the bathtub with enough water so that the water level is higher than the chiller inlet.
- Ensure the filter lid on the top is hand-tight.
- Ensure the inner strainer is installed and the bottle is hand-tight.
- Plug in and switch on the chiller. The chiller will start working.
- Check the water flow on the control panel. The water flow should be higher than 15L/min when the chiller starts working.
- IMPORTANT: If both the bathtub inlet and outlet are below the water level, there might be remaining air in the chiller affecting water flow. Open the drainer to let a little water out; the water flow should then return to normal.
- Built-in ozone sterilization system automatically starts periodically to disinfect the water.
- Once the desired temperature is reached, switch off the chiller before starting your cold water therapy session.
Touch Panel Introduction
The chiller features a large touch screen for easy operation and monitoring.
Status Icons Explained:
- WIFI: Indicates WiFi connection status.
- Locking: Indicates touch panel lock status.
- Ozone: Indicates ozone sterilization function status.
- Cooling: Indicates cooling function status.
- Heating: Indicates heating function status (if applicable).
- Defrosting: Indicates defrosting function status.
- Fault Warning: Appears when there is a failure.
- Water Flow: Displays the current water flow rate.
- Room Temp: Displays the ambient room temperature.
- Switch: Power on/off button.
Touch Panel Functions:
- 1. Turn on/off: Press the power button to turn the chiller on or off.
- 2. Enter Second Screen: Press the designated button to access additional settings.
- 3. Lock/Unlock: Press and hold for 3-5 seconds to lock or unlock the touch panel.
- 4. Temperature Adjustment: Use the '+' and '-' buttons to set the desired temperature.
- 5. Return: Click the return button to go back to the main interface.
- 6. WiFi Function: Long press to enter the WiFi function for connecting to Tuya or Smart Life apps.
- 7. Help Icon: Scan the QR code for technical support.
- 8. Temperature Unit Switching: Switch between Celsius (°C) and Fahrenheit (°F).
- 9. Button Sound: Adjust the touch screen prompt sound (ON/OFF).
- 10. Auto Power: Enable or disable automatic operation upon power-on.
Settings Menu:
- Ozone Time: Adjust the ozone working time interval (0 min to 5 min).
- Screen Brightness: Adjust the screen brightness (10% to 100%).
- Screen Sleep Time: Set the screen sleep duration (0 min to 5 min).
- Screen Lock Time: Set the screen lock timeout (0 min to 5 min).
WiFi Description and Mobile Application
The SY Pro Ice Bath Chiller can be controlled remotely via the Tuya Smart or Smart Life mobile application. Ensure your phone and the chiller are connected to a 2.4G wireless network.
Connecting to the App:
- Turn on the chiller.
- Click the settings key on the touch panel.
- Press the WiFi key for 3-5 seconds until the WiFi indicator blinks.
- Open the Tuya Smart App on your phone.
- Select 'Add Device'.
- Ensure your phone's WiFi is on and enter the WiFi password.
- Once successfully added, you can control the chiller through the app.
Tuya Smart Interface:
- 1. Turn ON/OFF: Control the chiller's power.
- 2. Locking: Lock or unlock the touch panel.
- 3. Temperature Unit Switching: Switch between °C and °F.
- 4. Water Flow: Monitor the current water flow rate.
- 5. Set Time Switch Timer: Schedule the chiller's operation times.
- 6. Touch screen prompt sound: Enable or disable button sounds.
- 7. Power-on automatic operation: Enable or disable automatic start-up.
- 8. Water Switch 1: Control water switch 1.
- 9. Water Switch 2: Control water switch 2.
- 10. Ozone working time interval: Adjust ozone sterilization time.
- 11. Temperature adjustment: Set the desired water temperature (3-42°C / 37-107°F).
- 12. Current Temperature: View the current water temperature.
Maintenance & Cleaning
Regular maintenance ensures optimal performance and longevity of your ice bath chiller.
Maintenance Steps:
- Never place the chiller outside in temperatures below 1°C when it contains water.
- Never clean the chiller with strong bleach-based detergents.
- Do NOT put corrosive disinfectants, such as chlorine tablets, into the water.
- ALWAYS disconnect the chiller from the power supply before any maintenance or cleaning.
- Regularly empty the chiller by opening the drainer at the rear of the unit and closing it after use. To prevent freezing damage, ensure the chiller is empty before the ambient temperature drops to 0°C (32°F).
- Replace the paper filter when it becomes dirty to ensure normal water flow rate and optimal performance.
- Check and clean the inner strainer when the water flow rate decreases. Cleaning every 4 weeks is recommended to ensure the water pump works perfectly.
- Check and clean the dust net when cooling/heating efficiency decreases. Cleaning every 3 months is recommended to ensure the condenser works perfectly.
- Please do NOT place the device directly under the sun or in rain or snow; place the machine under a shelter.
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC RF exposure statement: The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance between 20cm the radiator and your body.