Instruction Manual for Lepro models including: 350008-NW-US, LED Linear High Bay, 350008-NW-US LED Linear High Bay, Linear High Bay, High Bay, Bay

350012 13 -NW -US 说明书

Download User Manual

23,100 Lumens, 165W 2ft Dimmable Linear LED High Bay Light for Warehouses, Factories, 400W Metal Halide Equivalent, White 5000K, UL Listed

LED Linear High-Bay Installation Instructions

Power Net Weight / Carton Product Dimension 90W 5.4KG Max 630x300mm

Lepro 165W 2ft Dimmable Linear LED High Bay Light for Warehouses, Factories, 23,100 Lumens 400W Metal Halide Equivalent, White 5000K, UL Listed


File Info : application/pdf, 4 Pages, 1.10MB

PDF preview unavailable. Download the PDF instead.

350012-13-nw-us
LED Linear High-Bay Installation Instructions

Cautions: 1. Cannot use the electric generator to test the LED light. 2. Please abide by related country, regional and local laws and regulations when installing this fixture. 3. Turn off the power before installation or maintenance. 4. Proper earth grounding is required to ensure safety.

Notes: 1. To avoid the possibility of electric shock or fire, the installation personnel must have professional electrical knowledge. 2. Please wear gloves to avoid injury before installation. 3. If any smoke or spark of the wire occurs, turn off the power immediately and notify the relevant personnel. 4. Please use listed strain relief bushing when connecting the supply cord to the outlet box.

Attention: 1. Check if there was any damage during shipping. If so, please contact the manufacturer timely. 2. Please read the installation instructions carefully to check whether all the accessories are complete. After confirmation, install the fixture according to the installation steps.

Wiring Diagram & Instructions: 3 dimming functions are available in this high-bay light: 1. Constant current can be achieved by 1-10VDC dimming 2. PWM signal dimming 3. Variation of resistance unit dimming
Wiring Instructions L: Black N: White
: Green/Yellow DIM + DIM (For the wire color of DIM+ and DIM-, please check the light label.)

Description:
This product is 0-10 V dimming. The below dimmers are recommended:

Brand

Model

LUTON

NTSTV-DV

LEVITON

DS 710-10 Z / IP71 0

LEGRAND

RH4 FBL 3PW

Backup Driver Wiring Step 1: Open junction box with a screwdriver Step 2: Connect the input wires on each backup driver and fixture driver via suitable knockout, then complete the
junction box.

Wiring Instructions

ACL

Switch

ACN

INPUT

DC +

LED DRIVER

DC -

OUTPUT

ACL ACN

INPUT

BACKUP DRIVER

DRIVER + DRIVER -
LED LED +

LED

Please choose the appropriate dimming method according to your needs. You can also choose not to use this function. *The product cannot be connected to a dimming device when it's equipped with a motion sensor. Three installationsChain/cable installation3/4"NPT installationsurface mounting / pendent mounting. (Please choose the most suitable installation method for the purchased product as per your needs.)
-1-

A.Hanging Installation: (chain/cable) Step 1: Hook up the chain (figure 1) Step 2: Connect the chain with fixture (figure 1) Step 3: Fix the chain on the rail, adjust the chain length as per your needs; (figure 1) Step 4: After the fixing, choose the suitable wiring knockout and carry out the wiring according to local
standards and codes

Figure1
B.3/4"NPT Installation (if this bracket is used for the fixture, backup driver solution cannot be chosen) Step 1: Mount the bracket on 3/4"NPT (figure 2) Step 2: Lock fixture on the bracket (figure 3) Step 3: Do wiring according to local standards and codes Step 4: Lock side brackets with screwdriver (figure 4)

Figure2

Figure3

Figure4 -2-

C.Surface Mounting / Pendent Mounting: Step 1: Mount the bracket on the rail or ceiling (figure 5) Step 2: Mount bolt on the rail or ceiling, mount the fixture bracket onto the bolt (figure 6) and then install the fixture
(figure 7) Step 3: After mounting, choose suitable wiring knockout and carry out the wiring according to local standards and
codes

Figure5

Figure6

Figure7
Extra Accessory Option Installation: Wire guard, motion sensor / PIR Sensor, backup driver 1.Wire guard: (purchase the correct size wire guard from manufacturer) Step 1: Mount the wire guard on the fixture with screws (figure 8)

Figure8

2.Motion sensor / PIR Sensor: (both sensors require the same installation) Step 1: Open the face cover with a screwdriver (figure 9) Step 2: Knock out the side cover, mount the sensor on the side and carry out the wiring according to instructions on
the sensor (figure 10) Step 3: Put face cover back with screwdriver (figure 11)

Wiring Instruction

ACL ACN

Motion Sensor

ACL in
(Black)
ACL out
(Red)
ACN
(White)
Dim +
(Purple)
Dim -
(Gray/Pink)

ACL
(Black)

(Green/Yellow)

ACN
(White)
Dim +
(Purple)

LED Driver

Dim -
(Gray/Pink)

ACL ACN

ACL in
(Black)

PIR

ACL out

Sensor (Red)

ACN
(White)

Dim +
(Purple)
Dim -
(Gray/Pink)
ACL
(Black)

(Green/Yellow)

ACN
(White)
Dim +
(Purple)

LED Driver

Dim -
(Gray/Pink)

-3-

Figure9 Figure10 Figure11

3.Backup driver: Step 1: Knock off the knockout hole on the back of the fixture, take out the wires from the knockout hole (Figure.
12), open the front cover of the fixture, and knock out the two knockout holes on the cover (figure. 13) Step 2: Open the cover of the backup driver box, install the backup driver box at the corresponding position on the
back of the fixture (figure 14) and connect the wires correspondingly according to the marking instructions on the wire. Mount the buttons and indicators of the backup driver onto the front cover of the fixture (figure 15), then fix the cover to the fixture. Step 3: After mounting, choose suitable wiring knockout and carry out the wiring according to local standards and codes.

Figure12

Figure13

Figure14

Figure15

Possible maximum product weight (when specific mounts or function is chosen)

Power 90W 110W 135W 165W 220W 220W 300W 320W

Net Weight / Carton 5.4KG Max 5.4KG Max 5.9KG Max 5.9KG Max 6.5KG Max 8.5KG Max 9.3KG Max 9.3KG Max

Product Dimension 630x300mm 630x300mm 630x300mm 630x300mm 630x360mm 900x385mm 900x385mm 900x385mm

Warning / Avertissement MIN 90°C SUPPLY CONDUCTORS THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

The device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
-4-


Adobe PDF library 15.00