Instruction Manual for EMERSON models including: RP3E, Bettis RTS Relay Board Electric Actuator, RP3E Bettis RTS Relay Board Electric Actuator, RTS Relay Board Electric Actuator, Relay Board Electric Actuator, Board Electric Actuator, Electric Actuator, Actuator
D1-live.emerson.com
Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 June 2021 Bettis RTS Relay Board (RP3E) Electric Actuator Revision Details June 2021 Revision Details No. 1 Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 Date June 2021 Version 0 Type of Change General update (Migration to new template) Revision Details Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 Table of Contents June 2021 Table of Contents Section 1: Tools Tools.........................................................................................................................1 Section 2: Material Material.....................................................................................................................2 Section 3: Installation Installation................................................................................................................3 Section 4: Programming Programming............................................................................................................8 Table of Contents i Notes June 2021 Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 This page is intentionally left blank Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 Section 1: Tools June 2021 Section 1: Tools ! WARNING Remove all power supplies before doing the exchange. Act always with caution during the exchange! · Needle nose pliers · Screw driver phillips · Screw driver flat · Allen key 5 · Socket wrench 5 Figure 1 Tools 1 Section 2: Material June 2021 Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 Section 2: Material · 1x relay board RP3E6A (ID:13009) · 1x adapter cable (ID:16504) · 2x steel screw M3x16 (ID:952) · 3x plastic distance 8 mm (ID:9896) · 1x plastic screw M3x15 (ID:9895) · 1x plastic nut M3 (ID:7084) · 2x lock plates M3 red (ID:13674) Figure 2 Figure 3 2 Material Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 Section 3: Installation June 2021 Section 3: Installation Unscrew the 4 hexagon socket screws from the cover and remove it carefully. Mind the connection cable between display and logic board. Figure 4 Unscrew the 4 cross recessed screws from the existing logic board and afterwards tilt it carefully to you. Figure 5 Installation 3 Section 3: Installation June 2021 Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 Remove carefully the connected cables: ribbon cable, 6-8-10-poles plugs. Afterwards you can remove the logic board from the control unit and disconnect the 2nd ribbon cable on the back. Figure 6 Remove the two, marked with the red arrows, steel distances in the housing. Figure 7 4 Installation Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 Section 3: Installation June 2021 Put the plastic distances 8 mm between logic and relay board, insert the M3x16 steel screws through the estimated holes next to multi pin connector in logic board, plastic distances and relay board and secure the screws with the red lock plates. For the 3rd hole use the plastic screw M3x15 and secure it with plastic nut. Figure 8 Connect the relay board with the multi-pin connector from the logic board. NOTE 4 pins must stay free see FIgure 9. Orientation brings the mounting holes of both boards they must be in line. Figure 9 Installation 5 Section 3: Installation June 2021 Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 Connect the adapter cable with the 10 and 6-pole connector, after connect blue connectors with related one on the relay board. Figure 10 6 Installation Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 Section 3: Installation June 2021 Connect both ribbon cable and 8-pole connector with the logic board, after install the logic + relay board back to the control (two small screws for original installation will remain). Take care of possible damage of cables or other parts. Figure 11 Connect cable between display cover and logic board. Perform a Firmware update before installing display cover on the unit. This update is important for the following programming steps (use FW version display 1507, logic 219 or higher). For a detailed description on how to preform a firmware update, please refer to separate manual. During display cover installation, pay attention to the O-ring which must sit correct between cover and housing and fix it with the 4 hexagon socket screws. Figure 12 Installation 7 Section 4: Programming June 2021 Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 Section 4: Programming For programming, request download of SMARTTOOL2 through your Sales Representative. After the successful installation and registration, connect with the actuator. Use the Wizard and choose function "Install Extension Kit" and press "Apply". Figure 13 At the line "RP3E6A: 6x Relay Outputs, 3x Inputs" press "Apply" and confirm the installation by pressing "Ja". Figure 14 8 Programming Installation, Operation and Maintenance Manual VCIOM-15746-EN Rev. 0 Section 4: Programming June 2021 After installation press the "Refresh Button". In parameter group "9. Bin. Input" and "10. Relay" you can define the functionality of the different relays. Figure 15 Programming 9 World Area Configuration Centers (WACC) offer sales support, service, inventory and commissioning to our global customers. Choose the WACC or sales office nearest you: NORTH & SOUTH AMERICA MIDDLE EAST & AFRICA 19200 Northwest Freeway Houston TX 77065 USA T +1 281 477 4100 P. O. Box 17033 Jebel Ali Free Zone Dubai T +971 4 811 8100 Av. Hollingsworth 325 Iporanga Sorocaba SP 18087-105 Brazil T +55 15 3413 8888 ASIA PACIFIC No. 9 Gul Road #01-02 Singapore 629361 T +65 6777 8211 P. O. Box 10305 Jubail 31961 Saudi Arabia T +966 3 340 8650 24 Angus Crescent Longmeadow Business Estate East P.O. Box 6908 Greenstone 1616 Modderfontein Extension 5 South Africa T +27 11 451 3700 No. 1 Lai Yuan Road Wuqing Development Area Tianjin 301700 P. R. China T +86 22 8212 3300 EUROPE Holland Fasor 6 Székesfehérvár 8000 Hungary T +36 22 53 09 50 Strada Biffi 165 29017 Fiorenzuola d'Arda (PC) Italy T +39 0523 944 411 For complete list of sales and manufacturing sites, please visit www.emerson.com/actuationtechnologieslocations or contact us at info.actuationtechnologies@emerson.com www.emerson.com/bettis VCIOM-15746-EN ©2021 Emerson. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. BettisTM is a mark of one of the Emerson family of companies. All other marks are property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.MCM Plus Adobe PDF Library 15.0; modified using iTextSharp™ 5.5.10 ©2000-2016 iText Group NV (AGPL-version)