User Guide for MAX models including: RS-485 Wireless Link Transmitter, RS-485, Wireless Link Transmitter, Link Transmitter, Transmitter
Maximum Controls – Max Wireless RS-485 Pair
File Info : application/pdf, 2 Pages, 2.70MB
DocumentDocumentRange test ON on both PAIRING SECUENCE MAX Wireless RS-485 LINK FOR PRO SERIES www.max.us.com SYMPTOM If "link Ok" LED on Matrix III is OFF TROUBLESHOOTING POSSIBLE CAUSE SOLUTION Channels not matching on Wi RS 485 Set the RF Channels on both Wi RS 485 Link units Link units to the same channel Wi RS 485 Link units NOT paired Pair the two Wi RS 485 Link units using their pair buttons. Pair LED should turn ON on both units when properly paired Incorrect wiring between Matrix III and Wi RS-485 Link unit (primary and/or secondary operator) Double check if wiring on Wi RS 485 Link and Matrix III are as follows: (+) Matrix III to (+) Wi RS 485 Link (-) Matrix III to (-) Wi RS 485 Link On Matrix III board, Mode A, Dip Switch 8 is OFF Ensure Matrix III Mode A, Dip Switch 8 is ON 10530 Lawson River Ave., Fountain Valley, CA 92708 (949) 699-0220 | maxsales.us@gmail.com Rev 2B -05/04/23 MAX Wireless RS-485 LINK FOR PRO SERIES www.max.us.com The MAX wireless RS-485 is designed to wirelessly communicate between the PRIMARY and the SECONDARY MAX PRO gate operators. PRIMARY SECONDARY 2 PRIMARY Wi RS-485 Link 900MHz Robust Signal Up to 1 Mile using Line-of-Sight 1 TURN ON MODE A dip switch 8 to enable "wireless communication" on MATRIX III PRIMARY ONLY Wiring Primary Wi RS-485 Link to Matrix III as shown RADIO SIGNAL RADIO GND FIRE DEPT GND MAX OPEN GND STRIKE GND KEYPAD / CARD GND MANUAL RELEASE GND (+) GND (-) BATTERY INPUT BATTERY VOLTAGE BATTERY ERROR E 1/2 F INPUT BATTERY IN USE BATTERY BACKUP MODE LEAVE OPEN OPEN 1 TIME MATRIX III POWER / SOLAR IN MODULE PORT REPLACE BATTERY BATTERY POWER TEST LEAVE CLOSED ERD SENSITIVITY 14 12 16 MIN 1 9 MAX SENSE 3 7 OPENING 14 12 16 ERD MIN 1 9 MOTOR MAX OVER SENSE 3 7 LOAD CLOSING ERD MOTOR OVER LOAD RESET / MANUAL RELEASE OFF 1 2 ALARM 3 4 5 ID PLUG 6 ERROR 1 2 ID 3 4 PLUG 5 6 7 8 9 10 OFF EXIT PWR EXIT LOOP GND CENTER LOOP LOOP PWR SAFETY LOOP FAULTS 24VDC OUTPUT GND 12VDC OUTPUT GND MODE A MODE B OBD PORT BLACK BOX PROGRAMMING PROGRAM SOLAR MODE OFF ON OPERATOR PRIMARY SECONDARY MATRIX III SWING / SLIDE MOTION CONTROL OPEN STOP CLOSE QUICK CLOSE OPEN OPEN LEFT RIGHT OFF ON GATE GATE SPEED MIN MIN MAX OPENING MAX CLOSING LINK OK PRIMARY/ SECONDARY LINK CLOSE TIMER MIN MAX OFF ON/OFF BATTERY JOG LEFT RIGHT MAGLOCK DELAY OFF 2.5 sec 1.5 sec UL ENTRAP UL SENSOR 10K UL SENSOR N.C. MOTOR INPUTS MOTOR POSITION INPUTS SLIDER LIMIT SWING LIMIT GATE OPEN COM GATE CLOSED GND MAG NO LOCK COM NC OPEN ONLY NC PHOTO CLS NC OPEN/CLS NC 12VDC OUT GND OPEN ONLY 10K CLS ONLY 10K OPEN/CLS 10K 12VDC OUT GND OPEN STOP CLOSE COM GATE DISABLE TAMPER NO COM TAMPER IN GND JOG LEFT JOG RIGHT GND 485 (+) to (+) 485 (-) to (-) GND to GND +12V to 12V GND to GND Mounting Hole GND to GND + 12 V GND 3 Select "RF Channel #" using rotary switch ONLY use channels 0 thru 6. 485 + to + 485 - to - Power Wire Polarity does not matter PRIMARY Wi RS-485 Link Maximum Controls LLC. · 949.699.0220 · 10530 Lawson River Ave, Fountain Valley, CA 92708 Rev 5 JAN/19 SECONDARY Wi RS-485 Link 4 Wiring Secondary Wi RS-485 Link to Matrix III as shown 485 (+) to (+) 485 (-) to (-) GND to GND +12V to 12V GND to GND Operator Matri BATTERY INPUT BATTERY VOLTAGE BATTERY ERROR E 1/2 F INPUT BATTERY IN USE BATTERY BACKUP MODE LEAVE OPEN OPEN 1 TIME MATRIX III POWER / SOLAR IN MODULE PORT REPLACE BATTERY BATTERY POWER TEST LEAVE CLOSED ERD SENSITIVITY 14 12 16 MIN 1 9 MAX SENSE 3 7 OPENING 14 12 16 ERD MIN 1 9 MOTOR MAX OVER SENSE 3 7 LOAD CLOSING ERD MOTOR OVER LOAD RESET / MANUAL RELEASE OFF 1 2 ALARM 3 4 5 ID PLUG 6 ERROR 1 2 ID 3 4 PLUG 5 6 7 8 9 10 OFF EXIT PWR EXIT LOOP GND CENTER LOOP LOOP PWR SAFETY LOOP FAULTS 24VDC OUTPUT GND 12VDC OUTPUT GND MODE A MODE B OBD PORT BLACK BOX PROGRAMMING PROGRAM SOLAR MODE OFF ON OPERATOR PRIMARY SECONDARY MATRIX III SWING / SLIDE MOTION CONTROL OPEN STOP CLOSE QUICK CLOSE OFF ON OPEN OPEN LEFT RIGHT GATE GATE SPEED MIN MIN MAX OPENING MAX CLOSING LINK OK PRIMARY/ SECONDARY LINK CLOSE TIMER MIN MAX OFF ON/OFF BATTERY JOG LEFT RIGHT MAGLOCK DELAY OFF 2.5 sec 1.5 sec UL ENTRAP UL SENSOR 10K UL SENSOR N.C. MOTOR INPUTS MOTOR POSITION INPUTS SLIDER LIMIT SWING LIMIT GATE OPEN COM GATE CLOSED GND MAG NO LOCK COM NC OPEN ONLY NC PHOTO CLS NC OPEN/CLS NC 12VDC OUT GND OPEN ONLY 10K CLS ONLY 10K OPEN/CLS 10K 12VDC OUT GND TAMPER NO COM TAMPER IN GND JOG LEFT JOG RIGHT GND OPEN STOP CLOSE COM GATE DISABLE RADIO SIGNAL RADIO GND FIRE DEPT GND MAX OPEN GND STRIKE GND KEYPAD / CARD GND MANUAL RELEASE GND (+) GND (-) Mounting Hole LINK OK PRIMARY/ SECONDARY LINK (+) GND (-) GND to GND + 12 V GND 5 Select "RF Channel #" Channels MUST match in Primary and Secondary units. Power Wire Polarity does not matter 6 TEST RANGE 485 + to + 485 - to - 6 PAIR LED Link OK LED Must be ON in Primary and Secondary Matrix III Boards for Normal Operation (If not ON do range test below) SECONDARY Wi RS-485 Link GND (+) GND (-) LINK OK PRIMARY/ SECONDARY LINK TURN ON Range Test Switch in Primary Wi RS-485 Link Unit TURN ON Range Test Switch in Seconday Wi RS-485 Link Unit After few seconds, all three LED's will TURN ON when RF range is ok. If range is poor, reposition Primary or Secondary unit to get better range. (Check PAIR LED is ON, if not call tech support) SIGNAL QUALITY 3 LED's ON - Excellent | 2 LED's ON - Good | 1 LED ON - Poor 7 TURN OFF TEST RANGE SWITCH in both units MUST remain OFF for Normal Operation