76 Futura PC manual
ASENNUSOHJE | MONTERINGSANVISNING | MOUNTING INSTRUCTIONS

FUTURA

IP66 IK10

TEOLLISUUSVALAISIN SULJETTU | KAPSLAD INDUSTRIARMATUR | SEALED INDUSTRIAL LUMINAIRE

1272 / 1572

100 10
95

1172 / 1452

100 10
145

A

D

145

100 111

WHITE LED A [ mm] D[ mm]

1..2ft

662 350

1.4ft

1272 700

1.5ft

1572 940

COLOUR LED A [ mm] D[ mm]

1..2ft

662 350

1.4ft

1272 700

1.5ft

1572 940

 150 mm  150 mm

2.2ft - 6x

2x

2.4ft - 10x + 4x

2.5ft - 12x

2x

2x

2x

The power connector

if required

2x

2x

Valaisimen saa asentaa vain sähköalan ammat-

1

2

1x

1x tilainen. Käytä ainoastaan syöttöjännitettä ja

Cable gland PG 13,5 for wires Ø 6 - 12mm

Power connector supply if required

taajuutta joka on merkitty valaisimeen/liitäntälaitteeseen. Kytke virta pois päältä ennen asennusta tai huoltoa. Tämä asennusohje on säily-

tettävä ja sen on oltava käytössä asennuksessa

ja huollossa. Tämän valaisimen valonlähde ei ole vaihdettavissa. Kun valonlähde rikkoutuu, koko valaisin on poistettava käytöstä.

3
Click
4

3B

Vi rekommenderar att installationen görs

av en behörig elektriker. Använd en-

dast driftspänning och frekvens som är

märkt på armaturen/förkopplingsdonet.

Bryt stömmen före installation eller servi-

ce. Denna monteringsanvisning bör spa-

ras och finnas tillgänglig vid installation eller

framtida service. Ljuskällan till denna arma-

tur kan inte bytas ut. När ljuskällan når sin livs-

90°

längd ska hela armaturen bytas ut.

5

Click 1

Ø maØx1.01m0mm m

Only a professional electrician is allowed to do the installation. Use only rated voltage and frequency as marked in the fixture/driver.

Switch off the current before installation

or service. This mounting instruction must

be kept available during installation and

for future maintenance. The light source of

2

this luminaire is not replaceable; when the

6A

6B

light source reaches its end of life the whole luminaire shall be replaced.

Airam Electric Oy Ab, Sementtitehtaankatu 6, FI-04260 Kerava, Finland, www.airam.fi

2020.10.07

FUTURA

IP66 IK10

TEOLLISUUSVALAISIN SULJETTU | KAPSLAD INDUSTRIARMATUR | SEALED INDUSTRIAL LUMINAIRE

6C

7

1,5­2,5 mm 2

8-9 mm

LN
A

L3 N L1 L2 L3 N L1 L2

B

B

8

A

B

Click

10

Don`t open when the luminaire is alive!
12

(COLOUR)
Click

9
Always close the clips symmetrically from the middle to the sides of the lamp! Always close up both opposite clips at once
Click

1

2

3

11

Table of maximal number 10A B

of luminaires in one line



16A B


10A C


16A C


Length lm lm lm luminaires luminaires luminaires luminaires

2.2 2600

32

50

52

85

2.2 3200 4400

10

16

16

26

2.4 5200 6400 8800

10

16

16

26

2.4 12800

11

18

18

30

2.5 6500 8000 11000 10

16

16

26

2.5 16000

11

18

18

30

* With a luminaire LED COLOUR, there must always be only one colour ON!

2020.10.07

