Low Temperature Protection Function
Advanced options enter the third option ON, the thermostat is in the shutdown state, when the indoor temperature is lower than 5 degrees, the thermostat automatically turns on heating. when the indoor temperature rises to 5 degrees, the thermostat automatically turns off heating.

Application
Intelligent digital thermostat is a temperature controller suitable for floor heating systems. Through comparing ambient temperature and set temperature, it controls the working state of the electric valve of the floor heating system to adjust the ambient temperature, which is comfort and energy saving.

Electrical Specification
1. Temperature sensor: NTC 2. Temperature precision: +0.5°C 3. Self- consumed: < 170uW 4. Voltage: 3pcs 1.5V batteries 5. Load current: 3A(negative) 6. Protection grade: IP20

Operating Instructions
ON/OFF key: Press the ON/OFF key to turn on and off once; Press shutdown again while closing all valves.

Wiring Diagram N L M K1 K2 NO NC

Mode switch key: In the power-on state, press to switch the

working mode. The LCD

indicates the manual mode and the

display indicates the automatic mode.

Regulation key: In the startup state, press the button and the temperature will flash, then rotate the outer frame to adjust the temperature setting.

Clock adjustment: In the power on state, press and hold the ***

button for 5 seconds. After the icon flashes, rotate the outer frame to

adjust. Press the

button to switch between time and week

adjustments, and press the button to save and exit.

Lock key function: In the power on state, press and hold the button for 5 seconds to enter the lock button state on the panel.
A lock icon appears at the bottom of the display screen, indicating successful lock button locking

Remark: N & L: 110~220Vac input K1 & K2(dry contact): boiler / heater N & NO: normally close (NC) actuator N & NC: normally open (NO) actuator N & M: Valve
Notes: since some circuits of this product involve strong electricity, which need to be installed by professionals.

Code Matching Process:

Programming Mode Operation

· Output indicator · Code matching indicator · Power indicator

Code matching key

1. Power on the receiving panel, the power indicator is long on. Press and hold the code matching button for 3 seconds, and the code matching indicator flashes.

In the POWER ON state, press and hold the button for 5 seconds

to enter programming mode. After entering programming mode, press

the button to switch parameters, rotate the outer frame to adjust

various parameters, press the

button to adjust for minutes, and

press the

button to adjust the temperature. The adjustment

method for the following time periods is the same as the first time

period. Press the button to save and exit.

Key

Option

Workday 1 2 3 4 5 6
Day Off 1 2

Icon Time Adjust Default Adjust

time Value Temp.

06:00

20°C

08:00

16°C

11:30 12:30 17:00

Rotate Outer Frame

16°C 16°C 22°C

Rotate Outer Frame

22:00

16°C

08:00

22°C

23:00

16°C

Parameter Setting

In the POWER OFF state, long press the

button for 5 seconds to

enter the parameter setting interface. At this time, press the button

to cycle through the selection of the parameters to be set, rotate the

outer frame to adjust the parameters of each item, and press the 1

button to save and exit.

2. Install three pieces AA batteries on the transmitting panel. In the POWER OFF state, press and hold the button for 5 seconds to check the code. When the code checking indicator light on the receiving panel remains on, the code checking is successful.

Paramet er Item 1 2
3
4 5 6

Parameter Name
Temperature compensation
Switch deviation setting
The shutdown antifreeze function starts and stops

Rest

day

selection

Set the upper limit of the temperature
Restore factory settings

Default Value 0 1
ON
2 60°C --

Functional Meaning

The temperature compensation -9.9~9.9°C

range:

The temperature difference start-up range is 0.5~10°C

OFF: Turn off the antifreeze function ON: Turn on antifreeze function

0: Turn off programming 1: Take a day off 2: Two-day weekend 3: No rest
Set the upper temperature range from 15~95°C

Long press for 3 seconds, display "----_" to restore factory settings

Installation Method

WiFi Connection

1. Install an expansion screw sleeve with a spacing of 59mm on the wall.
2. Use a screwdriver to separate the upper cover and the lower cover, pursuant to the wire direction, pass the wire through the back cover to the wiring duct, and leave about 20cm long as per the actual situation.

Smart Life App Download For IOS system: Login in App Store, search " Smart Life "or " Tuya Smart", you can download it on your iphone. For Android System: Login in Google Play, search" Smart Life", or " Tuya Smart" ,you can download it on your phone. Or scan below code to download:

3. Fix the bottom shell to the wall, and finally fix the wire, and cover the front shell on the bottom shell.

Thermostat Setting

POWER OFF STATE

Inspection Steps
Install the intelligent touch screen thermostat in a place where it is easy for the user to view the screen and adjust the temperature set point. The thermostat is located in a place that can represent the overall ambient temperature of the room. Avoid installing the thermostat near hot and cold sources, such as vents, heaters, outdoors, etc.
Common Faults Handing

In the POWER OFF state, press and hold the

button for 5

seconds. When the WIFI icon is displayed on the screen, you can start

the configure on your phone.

Connection with phone Open"Smart Life "or"Tuya Smart" on your phone. Be sure to turn on your phone' s Bluetooth. Only 2 4G status configuration can be added for WIFI access on mobile phones (the name and password can only use numbers and letters, not symbols),

Phenomenon
Don't start up
LCD displays messy code

Solutions
1. Check whether the battery is installed backwards. 2. Inspect whether the boot key is valid LCD displays.
Whether the rear shell installation is deformed, it can be loosened and reinstalled.

Display normal, there is output

is but no

1. Check whether the boundary between the main control board and the power board is damaged. 2. Check whether the output is connected to the wrong wire.

Temperature displays error

Calibrate the panel temperature display via the first item of advanced options.

Click the Add Device button in the upper right corner, or click Add Device.

Enter the WIFI password, click Next.
Wait 1-2 minutes for the device to connect. If no, check the mobile phone, route, thermostat, and network device.
No flicker
After the configuration is completed, the WiFi icon of the thermostat does not flash.

