User Manual for Danfoss models including: ATEX Hydrokraft Piston Pumps and Motors, ATEX, Hydrokraft Piston Pumps and Motors, Piston Pumps and Motors, and Motors, Motors
Vickers by Danfoss Hydrokraft Piston Pumps and Motors ATEX Technical Information
File Info : application/pdf, 17 Pages, 847.89KB
DocumentDocumentUser Manual Vickers® by Danfoss Hydrokraft Piston Pumps and Motors ATEX Technical Information ATEX / UKEX Certified Hydrokraft Open Loop, Closed Loop 66 750 cc ATEX Directive 2014/34/EU UKEX SI 2016 No. 1107 II 2G Ex h IIC T4-T1 Gb X II 2G Ex h IIC T4-T1 Gb X User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line Revision History Table of Revisions Date Jul 2024 Changed First edition Rev 0101 2 | Vickers by Danfoss | November 2024 BC482851121479en-000101 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line Contents Introduction General Information.............................................................................................................................................................4 Purpose of this Document ......................................................................................................................................4 Product Description ..................................................................................................................................................4 Manufacturer Responsibility ..................................................................................................................................4 Product Safety .............................................................................................................................................................4 Intended Use ..........................................................................................................................................................................4 Marking of Vickers by Danfoss Hydrokraft Pumps and Motors.................................................................4 X-Marking: Special Conditions to Use.................................................................................................................5 Production Place and Date of Unit.......................................................................................................................5 Example ATEX / UKEX Label ...................................................................................................................................6 X-Conditions (1): Technical Information ATEX / UKEX Technical Specifications ...........................................................................................................................7 Operation Limits for selected T-Codes and Maximum Surface Temperature ................................................7 Gaseous Environment (G)........................................................................................................................................7 Oil Types / Operating Fluids..............................................................................................................................................7 Fluid Viscosity and General Temperature for ATEX / UKEX Hydrokraft Units.......................................8 Ambient Temperature..............................................................................................................................................8 Oil Temperature..........................................................................................................................................................8 Viscosity .........................................................................................................................................................................8 Filtering.....................................................................................................................................................................................9 Case Pressure..........................................................................................................................................................................9 Installation, Operation and Maintenance X-Conditions (2): Installation, Commissioning and Operation of ATEX / UKEX Hydrokraft Units ........ 10 Start-Up Procedure............................................................................................................................................................10 Pre-Start-Up Controls for Hydrokraft Units .................................................................................................... 11 First Start-Up .............................................................................................................................................................12 Operational Checks for Operation in Explosive Atmospheres .......................................................................... 12 Maintenance ........................................................................................................................................................................13 Recommended Check Activities ........................................................................................................................ 14 Service and Repair...................................................................................................................................................14 Further Safety Precautions...................................................................................................................................15 Summary of identified potential Ignition Hazards and Protective Means Vickers by Danfoss | November 2024 BC482851121479en-000101 | 3 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line Introduction General Information Purpose of this Document This User Manual has been prepared by the manufacturer in order to provide important information regarding the safe installation, operation and maintenance of ATEX / UKEX certified pumps & motors. The items set out within this document are mandatory unless stated otherwise. This User Manual is a supplement to existing product instruction as ATEX / UKEX components are subjected to some limitations compared to standard components. The limitations are described in this instruction. Items or limitations within this document override any contradictory information which may be found in the product catalog. It is intended for machine/system manufacturers, fitters and service technicians. Please read this User Manual carefully before you work with and start-up the unit. This User Manual must be stored in close proximity to the units. Product Description Hydrokraft pumps and motors are a range of variable displacement, high power open- and closed-circuit axial piston units designed for industrial applications. They feature a swashplate design with a maximum continuous working pressure of 350 bar. They can be supplied in fixed and variable displacement versions as well as in pump and motor configuration with a wide variety of control options. Manufacturer Responsibility The manufacturer declines any responsibility in case of: · Use of the product not according to safety regulations and legislation valid in the user's country. · Use of the product in operating conditions not allowed according to the product technical information. · Improper installation: the instructions given in this User Manual are not followed or not properly followed. · Hydraulic system problems. · Modification of the product. · Operations executed by personnel not properly trained or not assigned to such a kind of operations. Product Safety The safety of the product depends upon the strict observation of the indications given in this User Manual: in particular, it is necessary to: · Always operate within allowed product working operating conditions (please refer to the Technical Information of the unit in usage). · Always perform an accurate ordinary maintenance activity. · Assign the inspection activity as well as maintenance activity to duly trained personnel. · Only use original spares. · Always use the product according to the indications you find in this manual. Intended Use Hydraulic pumps convert mechanical energy (torque and speed) into hydraulic energy (pressure, oil flow). Hydraulic motors do the opposite, converting hydraulic energy into mechanical energy. Pumps and motors of the Hydrokraft product line are designed for industrial and heavy-duty applications. The below mentioned units fulfill the explosion requirements of the Directive 2014/34/EU and UKEX SI 2016 No. 1107 for the category shown on the name plate within the limiting conditions mentioned within this user manual or product catalog/ technical information. Hydrokraft units have an identifying name plate. The name plate provides essential information and specification for correct and safe use. This identifying plate has to be maintained so that the data can be clearly read; consequently, a periodic cleaning of the plate is required. If the nameplate or other labels need to be removed for maintenance or service, they need to be reinstalled before the unit is being recommissioned. Marking of Vickers by Danfoss Hydrokraft Pumps and Motors The supplied units are marked as equipment for Group II, category 2 for gas environment and with ignition protection constructional safety and liquid immersion. 4 | Vickers by Danfoss | November 2024 BC482851121479en-000101 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line Temperature class/Maximum surface temperature depends on the operating conditions (ambient and fluid temperature) as well as application duty cycles. Marking Ex II 2G Ex h IIC T4-T1 Gb X For model code option EX (see Table 1, page 7 for requirements) For detailed information on selecting the appropriate T-Codes as well as fluid viscosity and temperature requirements, please see Chapter "Operation Limits for selected T-Codes and Maximum Surface Temperature" on page 7. For explanation of marking letter "X", please refer to the following chapter "XMarking: Special Conditions to Use". X-Marking: Special Conditions to Use The unit's ATEX / UKEX certificate is only valid if the operation limits, warnings and guidelines stated within this manual are followed by the customer. Fluid type, viscosity, cleanliness and temperatures as per chapter "X-Conditions (1): Technical Information" must therefore be adhered to. The installation and system conditions stated in chapter "X-Conditions (2): Installation, Commissioning and Operation of ATEX / UKEX Hydrokraft Units" must be maintained. Production Place and Date of Unit The production location and date are shown on the unit label as pictured below. The ATEX certification of the units are done under the scope of: "Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres." And UKEX Statutory Instruments: "2016 No. 1107 HEALTH AND SAFETY The Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 2016" With following parameters: · Equipment group: II, non-mining equipment · Equipment Category: 2G · Temperature class: T4...T1 · Gas Group: IIC · Equipment protection level (EPL): Gb · Resulting Zone: 1 (Gas Environment) The Conformity Assessment Procedure must be executed according to: /1/ Directive 2014/34/EU, annex VIII, Modul A: Internal Production Control (see article 13, section 1 (b)(ii)) /2/ UKEX SI 2016 No. 1107 Schedule 3A, Part 6: Internal Production control (see Part 3, article 39 (1)(b)(ii)) The EU declaration of conformity has to be prepared and issued with regard to annex X of /1/. The "Essential Health and Safety Requirements" defined by /1/, annex II, have to be considered. The UK declaration of conformity has to be prepared and issued with regard to schedule 6 of /2/. The "Essential Health and Safety Requirements" defined by /2/, schedule 1, have to be considered. Vickers by Danfoss | November 2024 BC482851121479en-000101 | 5 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line Example ATEX / UKEX Label Legend 1. Manufacturer 2. Location of Production 3. Type/Brand Name of Product 4. ATEX / UKEX Code 5. 2D-Code for Identification 6. Manufacturer Address 7. Acknowledgement No 8. Warning, see user manual Warning If black anodized aluminum label is used, avoid impact on the aluminum nameplate material to eliminate thermite sparks 6 | Vickers by Danfoss | November 2024 BC482851121479en-000101 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line X-Conditions (1): Technical Information ATEX / UKEX Technical Specifications The technical specifications in this chapter are supplemental for ATEX / UKEX systems only. For comprehensive technical specifications, including maximum pressure rating, maximum flow, etc. please refer to the standard Technical Information and Technical Catalog documents. Danfoss does not claim responsibility for the use of the pumps/motors in operating conditions not allowed according to the information shown in this document and the standard Technical Information documents. Painting or coating can be an electric insulator if a thickness greater than 200 µm is applied. The thickness of the painting of original DPS paint is less than 200 µm. If the customer chooses to add an additional layer of paint, the total layer thickness cannot exceed 200 µm. The pumps/motors are approved only for correct and proper use in accordance with their designated purpose, in standard industrial atmospheres. Contravention of such conditions voids any warranty claims and any responsibility on the part of the manufacturer. Operation Limits for selected T-Codes and Maximum Surface Temperature Gaseous Environment (G) Table 1: Temperature Classes for Maximum Case Drain Temperatures Maximum Case Drain Temperature (measured max. 30 cm after housing drain port)1) 30 °C 86 °F Max. Ambient Temperature 40 °C 104 °F 50 °C 122 °F 60 °C 140 °F 80 °C [176 °F] T4 T4 T4 T3 90 °C [194 °F] T4 T4 T3 T3 100 °C [212 °F] T4 T3 T3 T3 110 °C [230 °F] T3 T3 T3 1) Applicable to FKM shaft seal. Can be lower if different shaft seal is used. E.g. max. rated case drain temperature for NBR = 80 °C Table 2: T-Codes with respective Maximum Surface Temperature T-Code / Temperature Class T3 T4 Maximum Surface Temperature °C °F 200 392 135 275 Warning The fluid temperature in the inlet line, working line or motor outlet line (closed & open loop applications) shall also never exceed the limits of "maximum case drain temperature" stated above. To ensure that the surface temperature will not exceed the allowed value according to the used temperature class, it is recommended (but not required) to attach a suitable temperature sensor to the unit in the shown area on one of the central surfaces at the housing surfaces towards the top of the unit (see Figure 1). Figure 1: Recommended location to attach surface temperature sensor (here: PVX, PVW, MFW) Oil Types / Operating Fluids Vickers by Danfoss | November 2024 BC482851121479en-000101 | 7 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line In a hydraulic system the most important task of the oil is to transfer energy. At the same time the oil must lubricate moving parts in hydraulic components, protect them from corrosion, and transport dirt particles and heat out of the system. To ensure that hydraulic components operate without problems and have long operating life, it is therefore vital to select the correct oil type with the necessary additives. Ratings and performance data are based on operating with hydraulic fluids containing oxidation, rust and foam inhibitors. These fluids must possess good thermal and hydrolytic stability to prevent wear, erosion and corrosion of unit components. For general guidance on fluid options, consult the catalogs or a Danfoss representative. Warning It is compulsory to use oils whose inflammable degree is at least 50K above the maximum surface temperature of the unit. Maximum surface temperature for Group IIG can be found under Table 2 on page 7. Fluid Viscosity and General Temperature for ATEX / UKEX Hydrokraft Units Table 3: Fluid Viscosity and Temperature Rating of Hydrokraft ATEX / UKEX Units Features Data Minimum Intermittent1) 10 mm²/s [59 SUS] Viscosity Continuous Operation Range 10 75 mm²/s [59 348 SUS] Maximum (Cold Start)2) 1000 mm²/s [4550 SUS] Minimum (Cold Start)2) -25 °C [-13°F] Inlet Temperature 4) Maximum Rated 80 °C [176 °F] Maximum Intermittent1) 90 °C [219 °F] Case Drain Temperature 4) Maximum Rated Maximum Intermittent1) 1) Intermittent = Short term t < 3 min per incident. 100 °C [212 °F] 3) 110 °C [230 °F] 3) 2) Cold start = Short term t < 3 min; p 50 bar; n 1000 min-1 (rpm); please contact Danfoss Power Solutions especially when the temperature is below -25 °C [-13 °F]. 3) Must not be exceeded locally either (e.g. in the bearing area) . The temperature in the bearing area is (depending on pressure and speed ) up to 5 °C [9 °F] higher than the average case drain temperature. 4) Applicable to FKM shaft seal. Can be lower if different shaft seal is used. E.g. max. rated case drain temperature for NBR = 80 °C Above maximum surface temperatures are without any deposited dust on the product. The possible insulation effect of a dust layer on the surface has to be taken into account by the safety margin to the minimum ignition temperature of the dust concerned. For up to 5 mm [1.97 in] layer thickness the safety margin is 75 °C [167 °F]. For further information please see IEC 60079-14. Warning The above operating temperatures (ambient and oil) of the unit/ system must be guaranteed by the end user. Ambient Temperature Maximum ambient temperature depends on the requested protection class needed. Refer to Table 1 on page 7. In general, the ambient temperature should lie between -25 °C [-13 °F] and +60° C [140 °F] to ensure that the shaft seal retains its sealing capacity. Oil Temperature Maximum oil temperature depends on the requested protection class needed. Refer to Table 1 on page 7. General limitations which must never be exceeded are stated in Table 3: Fluid Viscosity and Temperature Rating of Hydrokraft ATEX / UKEX Units. Under normal operating conditions it is recommended to keep the temperature in the range of 30 °C [86 °F] to 60 °C [140 °F] to achieve the expected unit lifetime. Viscosity Maintain fluid viscosity within the recommended range for maximum efficiency and bearing life. 8 | Vickers by Danfoss | November 2024 BC482851121479en-000101 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line Filtering Case Pressure Minimum viscosity should only occur during brief occasions of maximum ambient temperature and severe duty cycle operation. Maximum viscosity should only occur at cold start. Limit speeds until the system warms up. See Table 3: Fluid Viscosity and Temperature Rating of Hydrokraft ATEX / UKEX Units on page 8 for viscosity rating and limitations. We recommend the use of an oil type having a viscosity of 16 40 mm²/s [83 187 SUS] at the actual operating temperature. It is necessary to keep the level of oil contamination at an acceptable level to ensure problem-free operation. The recommended maximum level of contamination in systems with the hydraulic pumps or motors is 20/18/15 (ISO 4406-2021). Recommended fluid cleanliness for long product life or minimum if servo valves are used is 18/15/13 or better. Further information can be found in the technical catalog. The maximum permissible leakage pressure (case pressure) stated below must always be adhered to. Case/leakage pressure measurements are to be taken in close proximity to the unit housing as to avoid inaccurate readings due to pressure losses within hoses and tubing. For applications exceeding the general speed ratings please refer to a Danfoss application engineer for maximum case pressure rating. Figure 2: Maximum case gauge pressure depending on speed Case pressure at drain port (gauge) Max. pressure continuous 2.5 bar Pressure Peaks 5 bar Definition Generally max. permissible leakage pressure. Is reduced depending on rotational speed of the unit (see Figure 2). Max. pressure delta between inlet and case must also be adhered to (see application guidelines). t < 0.1 s Warning Ignition Risk of Explosive Gas Atmospheres or Flammable Dust due to Hot Surface Exceeding the maximum permissible case pressure may cause overheating of the shaft seal surface due to excessive friction or insufficient lubrication/cooling. This can lead to overheating and ignite explosive atmospheres. Severe injuries due to explosion pressure and fire can follow. Vickers by Danfoss | November 2024 BC482851121479en-000101 | 9 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line Installation, Operation and Maintenance X-Conditions (2): Installation, Commissioning and Operation of ATEX / UKEX Hydrokraft Units When assembling the unit in the machine/system it is the builder's responsibility that the parts used conform to the ATEX directive or UKEX statutory instruments and that the components are assembled and running according to the operational data/design found in product data sheets and instructions. Only use the unit as required by the explosion protection shown on the name plate. Start-Up Procedure Always ensure that the following is maintained: · The ambient conditions specified in this manual are maintained. · The unit may only be operated with the housing fully mounted, filled with fluid, unopened and in an undamaged condition. Dry run is prohibited after supervised initial priming. · The unit must be installed per specific orientation as specified within the catalog. The unit should be mounted in such a way, so that the case drain port is on the top of the unit. Vertical and "over tank" mounting of Hydrokraft pumps is possible, but bleeding and flushing of shaft bearings is required. For details, please refer to your Danfoss Representative. · The supporting frame, chassis, or structure of equipment containing the unit shall be constructed of electrically conducting material and shall be so arranged as to provide a leakage path to earth (ground) for any static electricity which occurs on the unit. If this is not possible, a grounding wire needs to be attached to the unit housing. Consult Danfoss for recommendations on connection placement. · The unit is approved for operation with the selected hydraulic fluid. · It is compulsory to use oils whose inflammable degree is at least 50K above the maximum surface temperature of the unit according to the temperature classification (T4, T3...). · All types of accessories installed on the unit are ATEX / UKEX specified and have been installed in accordance with ATEX / UKEX requirements. · There are no creeping metal elements external to the unit. · There are no plastic parts that might accumulate electrostatic; or they are shielded. · The inlet (A & B line for closed-loop units) and case drain oil and ambient temperature is monitored in close proximity to the unit to not exceed the maximum permissible for the category and temperature class of the associated zone. The sensors shall have a minimum accuracy of ±1 K. The system shall automatically and safely shut down within 30 seconds if a measurement exceeds ambient, case drain or inlet temperature limits stated within this manual respective to the desired temperature class. · The unit may only be operated when fully primed and filled with oil. An active oil level alarm shall be used. The system should safely shut down within 30 seconds after the event of a low oil alarm. · To avoid excessive heating of the shaft seal, the case pressure shall never exceed the limits stated in this document. Appropriate measures shall be taken to ensure this. · The unit must be protected against overloading and over-speeding using suitable measures. This includes the installation of pressure-relief valves to prevent the unit from exceeding the maximum allowable pressures or a speed encoder to detect overspeed of hydraulic motors. · For applications where running the unit for extended periods (>3 min) at "high-pressure low flow" (e.g. pressure compensated stand-by/ high speed motoring) conditions cannot be avoided, it is highly recommended to install case flushing. Consult Danfoss representative for advice. · Operational checks of the ignition protection devices must be performed according to "Operational Checks for Operation in Explosive Atmospheres" page 12. If sensors/devices that are part of the ignition protection fail, the system shall shut down within 60 seconds. A single fault occurring in the ignition protection system shall not lead to loss of the protection system safety function (fail-safe). Manufacture the assembly flange on the machine/system where the unit has to be installed: the relevant surface has to be perfectly smooth, completely de-greased and non-deforming. Coupling and protection elements shall meet the material requirements relevant to the respective ATEX / UKEX requirements (e.g. avoiding magnesium, titanium, zirconium). Impacts can damage the pump or create sparks. Especially avoid impacts on shaft, coupling, seals and sensitive assembled parts. It is necessary to verify the perfect alignment between the prime mover/ driven part output shaft and the pump/motor the fitment between pump/motor shaft and prime mover/driven shaft must be executed so that no radial or axial pre-load is generated these extra loads reduce the bearings expected lifetime and can increase heat generation. In case external loads cannot be avoided, consult Danfoss Power Solutions for advice on limitations and bearing life. 10 | Vickers by Danfoss | November 2024 BC482851121479en-000101 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line The purpose of this section is to indicate the necessary procedures to perform the pump/motor start-up. Pre-Start-Up Controls for Hydrokraft Units Before performing the first pump and motor start up, the following points have to be checked. Hydraulic components must be installed in accordance with their individual instruction. 1. To avoid contamination, plastic plugs in connection ports must not be removed until just before connections are made. All inlet connections must be tight to prevent air leaks. 2. Select the hydraulic fluid as specified in the product catalog. 3. Make sure the reservoir and circuit are clean and free of dirt/debris prior to filling with hydraulic fluid. Fill the reservoir with filtered oil to a sufficient level to prevent vortexing at suction connection to pump inlet. (It is good practice to clean the system by flushing and filtering using an external pump prior to first start-up) 4. Make sure the hydraulic connections allow the unit to rotate in the desired direction. 5. Ensure full contact between pump/motor mounting flange and prime mover/driven unit. Avoid pressing the unit into place by tightening the fixing bolts. Avoid unsuitable seal materials, for example, twine and Teflon, on threaded unions. Use only the seals supplied, such as O-rings, steel washers. 6. Make sure that all couplings are completely tightened to prevent leakage. Do not use more torque than the maximum values given in the instructions. 7. Before the unit/system is started, fill the case through the uppermost drain port with hydraulic fluid of the type to be used. The case drain line must be connected directly to the reservoir and must terminate below the oil level. 8. Check to make sure the purity of the oil is greater than 20/18/15 (ISO 4406-2021) and always use a filter when replenishing the system. Warning Ignition Risk of Explosive Gas Atmospheres or Flammable Dust due to Hot Surface Running the pump dry (without filling/ properly bleeding air from the housing) may cause overheating of the shaft seal surface due to missing lubrication and cooling as well as permanent damage of the unit internal components. This can lead to overheating and ignite explosive atmospheres. Severe injuries due to explosion pressure and fire can follow. · Always ensure that housing and inlet/outlet lines are filled before operation. · Make sure that in the case of "over tank installation" or any installation orientation with "shaft up" (e.g. vertical) front bearing flushing is installed and the shaft seal area is always filled with fluid. · Always connect the uppermost drain port as leakage path. · Do not exceed the maximum case pressure or maximum case drain temperature stated within this manual. · Confirm that the fluid is compatible with the shaft seal material. · Do not exceed the maximum speed. · Remove any accumulating dust and debris in a timely manner, especially near/under the dust lip. · Monitor reservoir level and immediately switch off system if the level falls below minimum value. · Regularly check the housing oil level (especially in "negative head" over-tank installation) and confirm that no air is trapped, causing insufficient bearing or shaft seal lubrication Vickers by Danfoss | November 2024 BC482851121479en-000101 | 11 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line First Start-Up 1. Make sure the reservoir and unit housing are filled with fluid and the inlet and outlet lines are open and unobstructed. 2. Start the prime mover at reduced speed. Once the pump is started it should prime within a few seconds. If the pump does not prime, check to make sure that there are no restrictions between the reservoir and the inlet to the pump, that the pump is being rotated in the proper direction, and that there are no air leaks in the inlet line and connections. Also check to make sure that trapped air can escape at the pump outlet. 3. After the pump is primed, operate for five to ten minutes (unloaded) to remove all trapped air from the circuit. If the reservoir has a sight gage, make sure the fluid is clear not milky. 4. To assure best pump or motor performance, run the pump or motor for approximately one hour at 30% of rated pressure and speed before running at full load. When running make sure the pump/motor and oil temperature and noise level are sufficiently low. High temperature or noise level might be symptoms of unforeseen operation conditions that have to be analyzed and cleared. 5. Check for system leakage and make sure the system is operating satisfactorily. 6. To ensure that the contamination in the hydraulic system does not damage the unit; the following procedure is recommended after a brief period in operation: a. After a brief period in operation, have a hydraulic fluid specimen analyzed for the required cleanliness level. b. Replace oil filter or change the hydraulic fluid if the required cleanliness level is not reached. Operational Checks for Operation in Explosive Atmospheres The product is an equipment which requires no settings or changes during operation. The machine/system manufacturer is responsible for the proper project planning of the hydraulic system and its control. The following checks must be performed to comply with ATEX directive: · Perform a "function and accuracy check of the ignition protection system" according to ISO 80079-39 clause 8.2.2: a. Check the sensors to ensure they produce the correct output signal in response to the characteristic being monitored and their accuracy is within the range described in this document. b. Check the ignition protection systems for correct operation as written within this document. c. Check if the ignition protection systems indicate a "fault" condition when defective or if a signal outside of the limits of the pre-determined maximum/minimum range is applied to it. System lockout: If a potential ignition source is prevented from becoming effective by means of stopping the equipment (see page 10), e.g. shutdown due to exceeding case drain temperature, the system shall be arranged so that the stop function locks out. The equipment shall not be able to be re-started without resetting of the devices. Operator intervention: The warning or display of the ignition protection system/device shall be designed to avoid operator confusion or misunderstanding with regard to the action required (e.g. low oil alarm or temporary increase in case oil temperature) Danfoss recommends ongoing tests for optimal pump performance: · Continuously verify that the temperature of the ambient and the operating oil are those initially determined and do not change rapidly. · Do not subject the pumps to pressure, pressure drop or speeds exceeding the maximum values stated in the appropriate catalogs. · Filter the oil to maintain the grade of contamination at 20/18/13 (ISO 4406-1999) or better. 12 | Vickers by Danfoss | November 2024 BC482851121479en-000101 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line Maintenance Warning If maintenance has to be performed in an explosive and hazardous atmosphere, an anti-sparking safety tool must be used. Maintenance measures involving disassembly or opening of the unit must only be carried out in nonexplosive atmospheres. Prior to loosening any connection of the hydraulic system, ensure the residual pressure has been removed from the system in a safe manner. With hydraulic systems the main criterion for reliability and operating life is very thorough regularly maintenance. Regularly check the system for presence of leakage and the oil level. The equipment must be regularly serviced and cleaned in the explosive atmosphere. The intervals are specified by the operator on-site in accordance with the environmental impact to which the equipment is exposed. During system's function, it is necessary regularly to verify that the temperature of the ambient and the operating oil are those initially determined. Replenish and change the oil, the oil and air filters as stated in the respective instructions. Regularly check the condition of the oil viscosity, oxidation, filtration level etc: Viscosity Verify that the viscosity level is within the recommended values as indicated in Table 3: Fluid Viscosity and Temperature Rating of Hydrokraft ATEX / UKEX Units on page 8. Oxidation Mineral oil gets oxidized proportional to the usage degree and operating temperature. The oxidation of oil is evident because of its change of color, bad smell, acidity increase and because of the generation of sludge inside the tank. In case symptoms of this kind are detected, the system oil must be immediately changed. Water presence The presence of water inside oil can be determined by taking oil samples from the bed of the oil tank: oil floats on water, if present, water tends to stay on the tank's bed. If its presence is determined, water must be regularly purged. Presence of water in the hydraulic system can severely damage the equipment. Degree of contamination A high degree of contamination of the operating oil causes a severe wear of all hydraulic components: for this reason, the cause of the contamination must be identified and eliminated. In order to avoid mixing of different oils, when replacing the operating fluid. It is necessary to empty all the machinery and pipes, clean them carefully and clean the tank. Vickers by Danfoss | November 2024 BC482851121479en-000101 | 13 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line Recommended Check Activities Activity Visual Check1) Monthly Visual check equipment for leaks, remove dust/dirt/debris deposits, check state of grease deposit at shaft seal (dust lip lubrication), check shaft seal & contact surface condition Check external temperature of the equipment using suitable measuring aids to ensure it is settling below 125°C [257°F] when unit is operating at cut-off and corner horsepower. Close-Up Check1) Every 6 Months or 4000hr 2) Detailed Check1) Every 12 Months or 8000hr N/A N/A Perform the operational checks of the sensors/devices which are part of the ignition protection system (see page 12) 1) Definitions of terms as per IEC 60079-17 2) Not necessary if monitored by recommended surface temperature sensor Service and Repair Only Authorized Service Centers or Danfoss Technicians may perform repairs specified in the Service Manual. The unit shall be overhauled or replaced prior to reaching the anticipated operating life as specified within the product catalog. For specific application inquiries contact Danfoss Technical Support. Unit components may only be replaced by genuine original Danfoss service parts which are also approved for use in explosive atmospheres. This also applies to the lubricants and service products used. In case a service or repair intervention on the unit is required, it must be performed according to the information shown in below mentioned Service Manual. The Service Manual includes the spare part list and information about how dismantling and assembling of the unit is done properly and can be provided by contacting Danfoss Power Solutions. For Spare parts lists, see: · Hydrokraft TVW 130-750 Closed Loop Pump Parts Manual; Literature Number: AX456070655588en · Hydrokraft Axial Piston Pumps PVX-066-250 Parts Manual; Literature Number: AX454665695719en · Hydrokraft Spare Parts List PFW MFW 250-750 Parts Manual; Literature Number: AX446962849176en CAUTION: Striking or impact forces could damage the axial piston unit. Do not strike the coupling or drive shaft. Do not set/place the unit on its drive shaft. Do not strike sensitive assembled parts or sealing surfaces. 14 | Vickers by Danfoss | November 2024 BC482851121479en-000101 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line Further Safety Precautions Always consider safety precautions before beginning a service procedure. Protect yourself and others from injury. Take the following general precautions whenever servicing a hydraulic system. Tools Warning It is compulsory to use anti sparking safety tools in case the service/repair activity has to be performed in explosive hazardous atmosphere. Sparking from External Impacts Warning Avoid impact on the aluminum nameplate or any other exposed aluminum surfaces to eliminate risk of thermite sparks. Avoid impact with light or hard metals on external surfaces. Unintended Machine Movement Warning Unintended movement of the machine or mechanism may cause injury to the technician or bystanders. To protect against unintended movement, secure the machine or disable/disconnect the mechanism while servicing. Follow the manufacturers instructions for securing the machine. Personal Safety Warning Protect yourself from injury. Use proper safety equipment, including safety glasses, at all times. Hot Surfaces Warning The unit surface temperature may exceed 70°C [158°F] during operation and after system power-down. Precautions should be taken to prevent accidental skin contact. Flammable Cleaning Solvents Warning Some cleaning solvents are flammable. To avoid possible fire, do not use cleaning solvents in an area where a source of ignition may be present Fluid Under Pressure Warning Escaping hydraulic fluid under pressure can have sufficient force to penetrate your skin causing serious injury and/or infection. This fluid may also be hot enough to cause burns. Use caution when dealing with hydraulic fluid under pressure. Relieve pressure in the system before removing hoses, fittings, gauges, or components. Never use your hand or any other body part to check for leaks in a pressurized line. Seek medical attention immediately if you are cut by hydraulic fluid. Vickers by Danfoss | November 2024 BC482851121479en-000101 | 15 User Manual ATEX / UKEX Certified Variable Axial Piston Units for Industrial Applications Hydrokraft Product Line Summary of identified potential Ignition Hazards and Protective Means Ignition Hazard Hot surface (Due to excessive leakage) Hot Surface (Housing) Hot Surface (Shaft Seal Friction) Protective Means Operate within X-conditions and limitations given within this manual and catalog. Install temperature probes and low-oil alarm for automatic shut-off. Never run pump dry. Impact resistance of housing is within compliance criteria. Replace shaft seal if it leaks. Operate within X-conditions and limitations given within this manual and catalog. Follow installation, operation, and maintenance guidelines. Automatic shut-off required if monitored process temperature limits within manual are exceeded. Operate within X-conditions, and limitations given within this manual and catalog. Run pump with properly filled housing at all times. Only use fluids chemically compatible with equipped elastomers. Install flushing if recommended by this manual (e.g. due to orientation). Mechanical Sparks (single manual impact) Static electricity (non-conductive surfaces) Construction avoided exposed light metals wherever possible. Warning added to avoid impact on aluminum surfaces (e.g. nameplate) or striking with light or hard metals. Exposed areas within compliance criteria. Paint thickness is within compliance criteria. Thickness shall not exceed 200µm if painted by customer. Grounding of unit necessary. Static electricity (conductive surfaces) Metallic Labels attached to housing via conductive mechanisms to avoid buildup of capacitance. Grounding of unit necessary. 16 | Vickers by Danfoss | November 2024 BC482851121479en-000101 Products we offer: · Cartridge valves · DCV directional control valves · Electric converters · Electric machines · Electric motors · Gear motors · Gear pumps · Hydraulic integrated circuits (HICs) · Hydrostatic motors · Hydrostatic pumps · Orbital motors · PLUS+1® controllers · PLUS+1® displays · PLUS+1® joysticks and pedals · PLUS+1® operator interfaces · PLUS+1® sensors · PLUS+1® software · PLUS+1® software services, support and training · Position controls and sensors · PVG proportional valves · Steering components and systems · Telematics · Former Eaton Hydraulic Products Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electric components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market as well as the industrial machines and marine sector. Building on our extensive applications expertise, we work closely with you to ensure exceptional performance for a broad range of applications. We help you and other customers around the world speed up system development, reduce costs and bring vehicles and vessels to market faster. Go to www.danfoss.com for further product information. We offer you expert worldwide support for ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide you with comprehensive global service for all of our components. Vickers by Danfoss: One of the most experienced and respected names in hydraulics, Vickers®, became part of Danfoss in 2021. Today, Vickers by Danfoss offers a comprehensive portfolio of field-proven industrial power and motion control components and systems, engineered to perform reliably even under the most extreme conditions. For more information and Vickers by Danfoss portfolio, visit https://www.danfoss.com/VickersIndustrial Danfoss Power Solutions your strongest partner in hydraulics and electrification. Hydro-Gear www.hydro-gear.com Daikin-Sauer-Danfoss www.daikin-sauerdanfoss.com Local address: Danfoss Power Solutions ApS Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: +45 7488 2222 Danfoss Power Solutions (US) Company 2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000 Danfoss Power Solutions II GmbH Dr. Reckeweg Strasse 1 76532 Baden-Baden Phone: +49 (0) 7221 682 233 Contact: info@danfoss.com Support: industrialpumpsmotorsupport@danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Vickers by Danfoss | November 2024 BC482851121479en-000101 | 17