User Manual for SmartGen models including: SGQ_ATS, Automatic Transfer Switch, SGQ_ATS Automatic Transfer Switch, Transfer Switch, Switch
File Info : application/pdf, 11 Pages, 830.81KB
DocumentDocumentSGQ_ATS AUTOMATIC TRANSFER SWITCH USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen -- make your generator smart SmartGen Technology Co., Ltd. No. 28 Jinsuo Road Zhengzhou City Henan Province P. R. China Tel: +86-371-67988888/67981888/67992951 +86-371-67981000(overseas) Fax: +86-371-67992952 Web: www.smartgen.com.cn/ www.smartgen.cn/ Email: sales@smartgen.cn All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder. Applications for the copyright holder's written permission to reproduce any part of this publication should be addressed to SmartGen Technology at the address above. Any reference to trademarked product names used within this publication is owned by their respective companies. SmartGen Technology reserves the right to change the contents of this document without prior notice. Date 2006-03-18 2010-10-19 2011-06-08 2011-11-22 2012-06-29 2012-11-08 2014-05-30 2015-03-30 2019-06-26 2019-09-11 2020-01-07 2022-01-04 Version 1.0 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 Table 1 Software Version Note Original release. Revision. Modify the wiring diagram of N type, T type and M type. Modify the technical data of N type, T type and M type. Lines of wiring diagram are bold. Format Modification. Add terminal number in wiring connection diagram. Modify some details. Modify M type wiring diagram, and add Q type switch. Modify wiring diagram of M type and Q type. Delete Q type switch and related parameters. Modify M type wiring diagram. CONTENTS 1 SUMMARY ..................................................................................................................................................4 2 STRUCTURE AND CHARACTERISTICS.....................................................................................................4 3 APPEARANCE AND CLASSIFICATION .....................................................................................................5 3.1 ILLUSTRATION ....................................................................................................................................5 3.2 N TYPE CASE DIMENSIONS AND TECHNICAL DATA........................................................................6 3.3 T TYPE CASE DIMENSIONS AND TECHNICAL DATA ........................................................................7 3.4 M TYPE CASE DIMENSIONS AND TECHNICAL DATA .......................................................................8 4 WORKING REQUIREMENTS.......................................................................................................................9 5 ATS WIRING CONNECTION DIAGRAM .....................................................................................................9 5.1 N AND T TYPE WIRING CONNECTION DIAGRAM..............................................................................9 5.2 M TYPE WIRING CONNECTION DIAGRAM...................................................................................... 10 6 INSTALLATION AND DEBUGGING......................................................................................................... 11 7 ORDER MODELS...................................................................................................................................... 11 SGQ_ATS Automatic Transfer Switch User Manual Page 3 of 11 1 SUMMARY SGQ Automatic Transfer Switch (ATS) is used under conditions of AC660V 50/60Hz or DC250V. It is two-stage PC class type with electromagnetism drive structure, which can make fast load transfer (transfer time 80ms) of two power circuits. It can be widely used for national one-class load, for example: high buildings, post, telecommunications, coal mines, ships, industrial assembly lines, health care, military facilities etc. The two power circuits can be grid, auto start genset, storage battery etc. 2 STRUCTURE AND CHARACTERISTICS SGQ Automatic Transfer Switch (ATS) adopts electromagnetic coil drive, electrical and mechanical interlocking structure, main loop structure of two static contacts and one dynamic contact. Dynamic contact applies V type, which ensures two power circuits shall not be short circuit. N type and T type apply double coils; M type applies single coil. Coils are only energized at the time of transfer and this extends the usage life of switch to a great degree. Coil control power can be supplied by master/slave AC or DC power and it is not needed to add another control power. Switch itself has mechanical or electrical close indication, and at the same time it provides volts free auxiliary contact. SGQ_ATS Automatic Transfer Switch User Manual Page 4 of 11 3 APPEARANCE AND CLASSIFICATION 3.1 ILLUSTRATION SGQ ATS can be classified into 3 types by appearance: N type, T type, M type. Each type has 3P and 4P, and N type still has 2P. The rated current series are: 63A, 125A, 160A, 200A, 250A, 400A, 630A, 800A, 1000A and 1250A. Switch appearances are as below. Table 2 Switch Appearance Type 2P 3P 4P N Type 63A, 125A T Nil Type 160A, 200A, 250A, 400A, 630A M Nil Type 630A, 800A, 1000A, 1250A SGQ_ATS Automatic Transfer Switch User Manual Page 5 of 11 3.2 N TYPE CASE DIMENSIONS AND TECHNICAL DATA TOP VIEW RIGHT VIEW Fig. 1 N Type Diagram Table 3 N Type Case Dimensions Model SGQ63N SGQ125N Overall size (mm) Installation size (mm) A B D C E 2P 3P 4P 2P 3P 4P 172 200 228 186 155 139 167 195 165 192 228 265 186 155 159 195 232 165 Copper bar and location hole (mm) M U T 5 12 27 7 20 37 Table 4 N Type Technical Data Type Rated current Rated limited short-circuit current Coil operating voltage Coil operating current Auxiliary contact Operation time Mechanical Electrical Number of poles Net weight (kg) Operation cycle SGQ63N SGQ125N 63A 125A 35kA AC220V (176~265)V 3.5A 1A 250VAC, N/O, Free Voltage, Each side has 2. 10000 times 4000 times 2P 3P 4P 2P 3P 4P 3.5 4 4.5 4 4.5 5. 5 15 seconds /time SGQ_ATS Automatic Transfer Switch User Manual Page 6 of 11 3.3 T TYPE CASE DIMENSIONS AND TECHNICAL DATA TOP VIEW LEFT VIEW Fig. 2 T Type Diagram Table 5 T Type Case Dimensions Model SGQ160T SGQ200T SGQ250T SGQ400T SGQ630T Overall size(mm) A D C 3P 4P 326 375 292 146 326 375 292 146 326 375 292 146 356 405 292 146 368 427 310 146 Installation size (mm) B E 3P 4P 307 356 200 307 356 200 307 356 200 337 386 200 349 408 200 Copper bar and location hole (mm) M NM U NU T 9 9 20 20 49 9 9 20 20 49 9 9 20 20 49 11 9 30 20 59 14 14 40 30 63 Table 6 T Type Technical Data Type Rated current Rated limited short-circuit current Coil operating voltage Coil operating current Auxiliary contact Operation time Mechanical Electrical Number of poles Net weight (kg) Operation cycle SGQ160T SGQ200T 160A 200A SGQ250T 250A SGQ400T SGQ630T 400A 630A 35kA AC220V (176~265)V 7A 1A 250VAC, N/O, Free Voltage, Each side has 2. 8000 times 3000 times 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 18 20 18 20 18 20 19 21 20 22 10 seconds/time SGQ_ATS Automatic Transfer Switch User Manual Page 7 of 11 3.4 M TYPE CASE DIMENSIONS AND TECHNICAL DATA TOP VIEW RIGHT VIEW Fig. 3 M Type Diagram Table 7 M Type Case Dimensions Models SGQ630M SGQ800M SGQ1000M SGQ1250M Overall size(mm) A D C 3P 4P 530 600 280 345 530 600 280 345 530 600 280 345 530 600 280 345 Installation size(mm) B E 3P 4P 490 560 210 490 560 210 490 560 210 490 560 210 Copper bar and location hole (mm) M U T 12 30 90 12 40 90 12 45 90 12 55 90 Table 8 M Type Technical Data Type Rated current Rated limited short-circuit current Coil operating voltage Coil operating current Secondary contact Operation time Mechanical Electrical Number of poles Net weight (kg) Operation cycle SGQ630M SGQ800M SGQ1000M SGQ1250M 630A 800A 1000A 1250A 50 kA AC220V (176~265)V 16A 1A 250VAC, N/O, Free Voltage, Each side has 1. 6000 times 3000 times 3P 4P 3P 4P 3P 4P 3P 4P 37 43.5 39 46 41 48 48 57 15s/time 20s/time 25s/time 25s/time SGQ_ATS Automatic Transfer Switch User Manual Page 8 of 11 4 WORKING REQUIREMENTS Item Working temperature Working Humidity Installation elevation Pollution class Installation type Table 9 Working Requirements (-40~+70)ºC (20~90)%RH 5000m III Requirements 5 ATS WIRING CONNECTION DIAGRAM 5.1 N AND T TYPE WIRING CONNECTION DIAGRAM 1. Position control I 3. Aux. contact of position I SB1 is #1 power close button Fig. 4 N Type and T Type 2. Position control II 4. Aux. contact of position II SB2 is #2 power close button SGQ_ATS Automatic Transfer Switch User Manual Page 9 of 11 5.2 M TYPE WIRING CONNECTION DIAGRAM 1. Position control I 3. Aux. contact of position I SB1 is #1 power close button H1 is #1 close indication Fig. 5 M Type 2. Position control II 4. Aux. contact of position II SB2 is #2 power close button H2 is #2 close indication SGQ_ATS Automatic Transfer Switch User Manual Page 10 of 11 6 INSTALLATION AND DEBUGGING All operations about ATS installation and debugging shall be conducted by professionals or persons knowing the switch device and protection and precaution measures must be considered during the operation. Wiring connection of main loop must make sure leading wire is not taking any pressure or force. Before installation and debugging please check firstly whether switch is damaged or whether there is harmful environment effect on it. At the same time please check whether there is loose wire resulting from transportation; clear the smudge, especially the smudge on the surface of insulating parts. The smudge probably is caused by the packing materials in the transportation process or in the storage process. Please make sure the phase sequences are in accordance at connecting the first circuit; please observe the wiring connection diagram of user manual strictly at connecting the second circuit and pay attention to control power voltage class at the same time. Ground must be well connected on switch installation. Considering personal safety and switch changeover rapidity, debugging handle can only be used for debugging and users are prohibited to operate on-load with debugging handle. First use the handle to operate switch, and if nothing unusual occurs, then operate button manually. If nothing unusual happens, then normal running can start. 7 ORDER MODELS Fig. 6 Model Illustration ____________________________________ SGQ_ATS Automatic Transfer Switch User Manual Page 11 of 11