User Manual for SmartGen models including: SGQ_ATS, Automatic Transfer Switch, SGQ_ATS Automatic Transfer Switch, Transfer Switch, Switch

USER MANUAL

smartgen.cn


File Info : application/pdf, 11 Pages, 830.81KB

PDF preview unavailable. Download the PDF instead.

SGQ ATS en
SGQ_ATS AUTOMATIC TRANSFER SWITCH
USER MANUAL
SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD.

Chinese trademark
English trademark SmartGen -- make your generator smart SmartGen Technology Co., Ltd. No. 28 Jinsuo Road Zhengzhou City Henan Province P. R. China Tel: +86-371-67988888/67981888/67992951
+86-371-67981000(overseas) Fax: +86-371-67992952 Web: www.smartgen.com.cn/
www.smartgen.cn/ Email: sales@smartgen.cn
All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder. Applications for the copyright holder's written permission to reproduce any part of this publication should be addressed to SmartGen Technology at the address above. Any reference to trademarked product names used within this publication is owned by their respective companies. SmartGen Technology reserves the right to change the contents of this document without prior notice.

Date 2006-03-18 2010-10-19 2011-06-08 2011-11-22 2012-06-29 2012-11-08 2014-05-30 2015-03-30 2019-06-26 2019-09-11 2020-01-07 2022-01-04

Version 1.0 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0

Table 1 Software Version
Note Original release. Revision. Modify the wiring diagram of N type, T type and M type. Modify the technical data of N type, T type and M type. Lines of wiring diagram are bold. Format Modification. Add terminal number in wiring connection diagram. Modify some details. Modify M type wiring diagram, and add Q type switch. Modify wiring diagram of M type and Q type. Delete Q type switch and related parameters. Modify M type wiring diagram.

CONTENTS
1 SUMMARY ..................................................................................................................................................4 2 STRUCTURE AND CHARACTERISTICS.....................................................................................................4 3 APPEARANCE AND CLASSIFICATION .....................................................................................................5
3.1 ILLUSTRATION ....................................................................................................................................5 3.2 N TYPE CASE DIMENSIONS AND TECHNICAL DATA........................................................................6 3.3 T TYPE CASE DIMENSIONS AND TECHNICAL DATA ........................................................................7 3.4 M TYPE CASE DIMENSIONS AND TECHNICAL DATA .......................................................................8 4 WORKING REQUIREMENTS.......................................................................................................................9 5 ATS WIRING CONNECTION DIAGRAM .....................................................................................................9 5.1 N AND T TYPE WIRING CONNECTION DIAGRAM..............................................................................9 5.2 M TYPE WIRING CONNECTION DIAGRAM...................................................................................... 10 6 INSTALLATION AND DEBUGGING......................................................................................................... 11 7 ORDER MODELS...................................................................................................................................... 11

SGQ_ATS Automatic Transfer Switch User Manual

Page 3 of 11

1 SUMMARY
SGQ Automatic Transfer Switch (ATS) is used under conditions of AC660V 50/60Hz or DC250V. It is two-stage PC class type with electromagnetism drive structure, which can make fast load transfer (transfer time 80ms) of two power circuits. It can be widely used for national one-class load, for example: high buildings, post, telecommunications, coal mines, ships, industrial assembly lines, health care, military facilities etc. The two power circuits can be grid, auto start genset, storage battery etc.
2 STRUCTURE AND CHARACTERISTICS
SGQ Automatic Transfer Switch (ATS) adopts electromagnetic coil drive, electrical and mechanical interlocking structure, main loop structure of two static contacts and one dynamic contact. Dynamic contact applies V type, which ensures two power circuits shall not be short circuit. N type and T type apply double coils; M type applies single coil. Coils are only energized at the time of transfer and this extends the usage life of switch to a great degree. Coil control power can be supplied by master/slave AC or DC power and it is not needed to add another control power. Switch itself has mechanical or electrical close indication, and at the same time it provides volts free auxiliary contact.

SGQ_ATS Automatic Transfer Switch User Manual

Page 4 of 11

3 APPEARANCE AND CLASSIFICATION

3.1 ILLUSTRATION

SGQ ATS can be classified into 3 types by appearance: N type, T type, M type. Each type has 3P and 4P, and N type still has 2P.
The rated current series are: 63A, 125A, 160A, 200A, 250A, 400A, 630A, 800A, 1000A and 1250A. Switch appearances are as below.

Table 2 Switch Appearance

Type

2P

3P

4P

N Type

63A, 125A

T Nil
Type

160A, 200A, 250A, 400A, 630A

M Nil
Type

630A, 800A, 1000A, 1250A

SGQ_ATS Automatic Transfer Switch User Manual

Page 5 of 11

3.2 N TYPE CASE DIMENSIONS AND TECHNICAL DATA TOP VIEW

RIGHT VIEW

Fig. 1 N Type Diagram

Table 3 N Type Case Dimensions

Model
SGQ63N SGQ125N

Overall size (mm)

Installation size (mm)

A

B

D C

E

2P 3P 4P

2P 3P 4P

172 200 228 186 155 139 167 195 165

192 228 265 186 155 159 195 232 165

Copper bar and location hole (mm)

M

U

T

5

12 27

7

20 37

Table 4 N Type Technical Data

Type

Rated current

Rated limited short-circuit current

Coil operating voltage

Coil operating current

Auxiliary contact

Operation time

Mechanical Electrical

Number of poles

Net weight (kg)

Operation cycle

SGQ63N

SGQ125N

63A

125A

35kA

AC220V (176~265)V

3.5A

1A 250VAC, N/O, Free Voltage, Each side has 2.

10000 times

4000 times

2P

3P

4P

2P

3P

4P

3.5

4

4.5

4

4.5

5. 5

15 seconds /time

SGQ_ATS Automatic Transfer Switch User Manual

Page 6 of 11

3.3 T TYPE CASE DIMENSIONS AND TECHNICAL DATA TOP VIEW

LEFT VIEW

Fig. 2 T Type Diagram

Table 5 T Type Case Dimensions

Model
SGQ160T SGQ200T SGQ250T SGQ400T SGQ630T

Overall size(mm)
A D C
3P 4P 326 375 292 146 326 375 292 146 326 375 292 146 356 405 292 146 368 427 310 146

Installation size (mm)
B E
3P 4P 307 356 200 307 356 200 307 356 200 337 386 200 349 408 200

Copper bar and location hole (mm)

M NM U NU T

9

9 20 20 49

9

9 20 20 49

9

9 20 20 49

11

9

30 20 59

14 14 40 30 63

Table 6 T Type Technical Data

Type Rated current

Rated limited short-circuit current

Coil operating voltage

Coil operating current

Auxiliary contact

Operation time

Mechanical Electrical

Number of poles

Net weight (kg)

Operation cycle

SGQ160T SGQ200T

160A

200A

SGQ250T 250A

SGQ400T SGQ630T

400A

630A

35kA

AC220V (176~265)V 7A
1A 250VAC, N/O, Free Voltage, Each side has 2. 8000 times 3000 times
3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 18 20 18 20 18 20 19 21 20 22
10 seconds/time

SGQ_ATS Automatic Transfer Switch User Manual

Page 7 of 11

3.4 M TYPE CASE DIMENSIONS AND TECHNICAL DATA TOP VIEW

RIGHT VIEW

Fig. 3 M Type Diagram

Table 7 M Type Case Dimensions

Models
SGQ630M SGQ800M SGQ1000M SGQ1250M

Overall size(mm)

A

D

C

3P

4P

530 600 280 345

530 600 280 345

530 600 280 345

530 600 280 345

Installation size(mm)

B

E

3P

4P

490 560 210

490 560 210

490 560 210

490 560 210

Copper bar and location hole (mm)

M

U

T

12

30

90

12

40

90

12

45

90

12

55

90

Table 8 M Type Technical Data

Type

Rated current

Rated limited short-circuit current

Coil operating voltage

Coil operating current

Secondary contact

Operation time

Mechanical Electrical

Number of poles

Net weight (kg)

Operation cycle

SGQ630M

SGQ800M

SGQ1000M SGQ1250M

630A

800A

1000A

1250A

50 kA

AC220V (176~265)V

16A

1A 250VAC, N/O, Free Voltage, Each side has 1.

6000 times

3000 times

3P

4P

3P

4P 3P

4P

3P 4P

37

43.5 39

46 41

48

48 57

15s/time

20s/time

25s/time

25s/time

SGQ_ATS Automatic Transfer Switch User Manual

Page 8 of 11

4 WORKING REQUIREMENTS

Item Working temperature Working Humidity Installation elevation Pollution class Installation type

Table 9 Working Requirements

(-40~+70)ºC (20~90)%RH 5000m III 

Requirements

5 ATS WIRING CONNECTION DIAGRAM

5.1 N AND T TYPE WIRING CONNECTION DIAGRAM

1. Position control I 3. Aux. contact of position I SB1 is #1 power close button

Fig. 4 N Type and T Type
2. Position control II 4. Aux. contact of position II SB2 is #2 power close button

SGQ_ATS Automatic Transfer Switch User Manual

Page 9 of 11

5.2 M TYPE WIRING CONNECTION DIAGRAM

1. Position control I 3. Aux. contact of position I SB1 is #1 power close button H1 is #1 close indication

Fig. 5 M Type 2. Position control II 4. Aux. contact of position II SB2 is #2 power close button H2 is #2 close indication

SGQ_ATS Automatic Transfer Switch User Manual

Page 10 of 11

6 INSTALLATION AND DEBUGGING
All operations about ATS installation and debugging shall be conducted by professionals or persons knowing the switch device and protection and precaution measures must be considered during the operation. Wiring connection of main loop must make sure leading wire is not taking any pressure or force. Before installation and debugging please check firstly whether switch is damaged or whether there is harmful environment effect on it. At the same time please check whether there is loose wire resulting from transportation; clear the smudge, especially the smudge on the surface of insulating parts. The smudge probably is caused by the packing materials in the transportation process or in the storage process. Please make sure the phase sequences are in accordance at connecting the first circuit; please observe the wiring connection diagram of user manual strictly at connecting the second circuit and pay attention to control power voltage class at the same time. Ground must be well connected on switch installation. Considering personal safety and switch changeover rapidity, debugging handle can only be used for debugging and users are prohibited to operate on-load with debugging handle. First use the handle to operate switch, and if nothing unusual occurs, then operate button manually. If nothing unusual happens, then normal running can start.
7 ORDER MODELS

Fig. 6 Model Illustration ____________________________________

SGQ_ATS Automatic Transfer Switch User Manual

Page 11 of 11



References

Microsoft Word 2016 Microsoft Word 2016