Instruction Manual for Saxby trade models including: CCT Microwave Emergency, CCT, Microwave Emergency, Emergency
7 lamps included the master light. Technical data. 220-240 V~, 50 Hz. Supply. Voltage: Bulb. Type: 95542----18/14/9W LED (SMD) CCT, 3000/4000/6000K. 900/1400 ...
File Info : application/pdf, 2 Pages, 1.38MB
DocumentDocumentMicrowave Movement Sensor This product is fitted with a microwave movement sensor. Please see below detailed operating instructions. Technical Specifications: Operating voltage 220 ~ 240V AC 50/60Hz Rated load Stand-by power 400W (Capacitive load) 800W (Resistive load) 0.5W Sensitivity Hold-time Ceiling mounted height: 3m Ceiling mounted height: 6m* Wall mounted height: 2m 100% / 75% / 50% / 25% / 10% 100% / 75% / 50% 100% / 75% / 50% / 25% / 10% 5s / 30s / 90s / 3min / 20min / 30min Daylight sensor 2Lux / 10Lux / 25Lux / 50Lux / Disable Microwave frequency 5.8 GHz ±75MHz Transmitting power 1mW Max. Ceiling mounted Detection range height: 3m Wall mounted height: 1.5-2m Detection angle 3- 6m (radius ) 12-15m 3600 (Ceiling) / 1200 (Wall) Working temperature -200C ~ 600C *50%, 75%, 100% detection sensitivity is workable when installed at 6m mounting height. Only 10%, 25% sensitivity is not able to detect motion signal. Settings: 1. Sensitivity Sensitivity can be adjusted by selecting the combination on the DIP switches for different applications. 2. Hold-time Hold-time refers to the time period that the light remains 100% on if no more movement is detected. 3. Daylight sensor Different daylight threshold can be preset on DIP switches. Light will always turn on upon movement if daylight sensor is disabled. I 100% II 75% III 50% IV 25% V 10% 123 100% 75% 50% 25% 10% I 5s II 30s III 90s IV 3min V 20min VI 30min 456 5s 30s 90s 3min 20min 30min I 2Lux II 10Lux III 25Lux IV 50Lux V Disable 789 2Lux 10Lux 25Lux 50Lux Disable* *Disable means the daylight sensor does not work. The sensor will turn on light once motion is detected regardless of ambient light level. Trouble shooting: Malfunction Cause Remedy The light will not come on The lamp is always on The lamp is on without any identifiable movement The lamp will not work despite movement Cause Incorrect light-control setting selected Faulty lamp No power supply Continuous movement in the detection zone The sensor is not mounted for reliably detecting movement Movement occurred, but not identified by the sensor (Movement behind wall, movement of small object in immediate lamp vicinity etc.) Rapid movements are being suppressed to minimize malfunctioning or the detection radius is too small. Remedy Adjust daylight threshold setting Replace lamp Check power to sensor Check detection area setting Securely mount enclosure 1. Reduce sensitivity. 2. Check the movement behind walls to avoid facilities such as water pipe, fan, which may mis-trigger the sensor. Check detection area setting Care and Safety We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish. For your safety, always switch off the power supply before cleaning. For further information, please visit https://www.lighting-info.co.uk/95542 V8 30/01/2024 UK Manufacturer: BH17 7BY EU Manufacturer: Brilliant AG, Brilliantstrasse 1, D-27442 Gnarrenburg Instruction manual HeroPro CCT Microwave Emergency 95542, 103940 www.saxbylighting.com Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference. Warning Technical data This light fitting is double insulated and does not require connection to an earth circuit. Please read these instructions carefully before commencing any work. This unit must be fitted by a competent and qualified electrician. Install in accordance with the IEE Wiring regulations and current Building Regulations. Check the pack and make sure you have all the parts listed. To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified electrician. Supply Voltage: Bulb Type: 220-240 V~, 50 Hz 95542----18/14/9W LED (SMD) CCT, 3000/4000/6000K 900/1400/1800Lm - 143.8Lm in EM mode 103940---28/24/20W LED (SMD) CCT, 3000/4000/6000K 2000/2400/2800Lm - 190Lm in EM mode These products contain a light source of energy efficiency class D. Non-replaceable light source Replaceable control gear by a professional Conformity with all relevant UKCA Directive requirements. This light fitting should be connected to a fused circuit. If replacing an existing fitting, make a careful note of the connections. Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice. Layout Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between each light fitting. Avoid locating any cables in positions that would cause a hazard. Position cables and junction boxes (not supplied) away from areas where they may be at risk from being cut, trapped or damaged. The mains supply cable must have a minimum cross section area of 1.0mm2. Cables must be protected using suitable conduit or plastic trunking. The products can be wall or ceiling mounted. If wall mounting ensure that the power supply is at the bottom. Conformity with all relevant EC Directive requirements. The power supply is Double Insulated and does not require connection to an Earth circuit. Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or local store for recycling advice. This product is not suitable for dimming. IP65 This product is rated at IP65 IK10 This product is rated at IK10 for 95542. IK08 This product is rated at IK08 for 103940. Battery parameters: Duration 3 hours (180 Minutes) Installation Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires. Note the switch is turned off before installation. The ceiling surface must be flat and smooth to ensure a good fit. Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product. · Twist and remove the lamp cover from the product, keep safe for refitting later. · Turn the clip to loose the LED tray in the rear casing. · Using the rear casing as a template mark the position to drill out the fixing holes. Take care to avoid damaging any concealed wiring and pipes. · Fix the rear casing into the position using the installation plugs and screws. · Pull the cable through the cable entry hole and seal to maintain the IP rating and wire as detailed Wiring Diagram. Maximum Operating Humdity Change over time Battery Specification Battery Charge Time Battery warranty Ambient Temperature 90% Approximately 1s LifePO4 3.2V 1500mAh 24 Hours 5 years 0ºC - 45ºC · Unscrewed the battery box cover and then connect the battery DC connector together before commissioning. · Refit the LED tray back into the rear casing and lock the clip. · Twist the lamp cover back onto the product and lock in place. · Replace fuse or circuit breaker and switch on. Your light is now ready for use. The wattage is changeable between the diffrent wattage using the wattage switch on the driver before installation. 18W 14W 9W For the 95542 is the 18W/14W/9W selectable 28W 24W 20W For the 103940 is the 28W/24W/20W selectable The colour is changeable between 3000/4000/6000K using the CCT switch on the driver before installation. 6000K 4000K 3000K Choose your preferred wattage and colour before installing by wattage switch or CCT switch on the driver. Note: Befeore you change the wattage or colour, please turn off the power switch for safety. 1 2 3 4 5 6 * Product images may vary. Bezels for 95542 only The following individual casings are available for purchase separately. 95545 : Chrome plain 95548 : Black plain 95551 : Anthracite grey plain 95546 : White eyelid 95549 : Black eyelid 95552 : Anthracite grey eyelid 95547 : White grill 95550 : Black grill 95553 : Anthracite grey grill Wiring · This product is double insulated and must not be earthed. If there are any incoming earth cables, they must be joined together and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your property. SUPPLY PUSH DOWN LIGHT FITTING INSERT CABLE · Having correctly identified the wiring from your existing light fitting, connect to the quick fit connection block in the following way, using the supplied link cables where necessary. Non-Maintained Wiring: The product is normally off and comes on during a power failure MW SENSOR LED Driver INPUT OUTPUT SUPPLY LIGHT FITTING L N N L' LN N NEUTRAL L/PL N Emergency SL PL Lout Maintained (Unswitched) Wiring: The product is on permanently and comes on during a power failure SUPPLY MW SENSOR INPUT OUTPUT LIGHT FITTING L N N L' LED Driver LN N NEUTRAL SWITCH LIVE LINK CABLE L/PL N Emergency PERMANENT LIVE "Lout" terminal is only for connecting with OUTPUT of MW sensor, don't for the INPUT Maintained (Switched) Wiring: The product is used as a normal light - switch on/off, light turns on/off. Comes on during a power failure. SUPPLY MW SENSOR INPUT OUTPUT LIGHT FITTING L N N L' LED Driver LN N NEUTRAL L/PL N Emergency SL PL Lout SL PL Lout "Lout" terminal is only for connecting with OUTPUT of MW sensor, don't for the INPUT SWITCH LIVE PERMANENT LIVE "Lout" terminal is only for connecting with OUTPUT of MW sensor, don't for the INPUT Sensor Used as Master Function L N ...... Lout Master Slave Master N SL PL Lout N SL PL N SL PL N SL PL Lout ...... Emergency LED Driver LN LED Driver LN LED Driver LN Emergency LED Driver LN L/PL N L/PL N INPUT LN OUTNPUT 0.75 1.5 NL INPUT LN OUTNPUT 0.75 1.5 NL 10% 30min 89 2Lux 10Lux 25Lux 50Lux 123456789 LED 95542 LED 103940 LED 95539 LED 102732 10% 30min 89 2Lux 10Lux 25Lux 50Lux 123456789 LED 95542 LED 103940 *The master light LED 95542 match with the slave light LED 95539, in total link QTY is Max. 10 lamps included the master light. *The master light LED 103940 match with the slave light LED 102732, in total link QTY is Max. 7 lamps included the master light. Check that... You have correctly identified the wires. The connections are tight. No loose strands have been left out of the connection block.