User Guide for FETCO models including: CBS-1251 Extractor Plus Brewing System, CBS-1251, Extractor Plus Brewing System, Plus Brewing System, Brewing System

Chris Michalek's CBS-1250 PLUS with active hotlinks

Chris Michalek-Wer ist ein engel

FETCO - User's Guide and Operator Instructions CBS-1251

2021-11-15 — Rinse dispensers before reuse. Every Day: 1. Wash brew basket with hot sudsy water. 2. Pull CSD from the spray head, it is ...

Chris Michalek's CBS-1250 PLUS with active hotlinks


File Info : application/pdf, 32 Pages, 9.62MB

PDF preview unavailable. Download the PDF instead.

P213-CBS-1250Plus-User-Guide
User's Guide and Operator Instructions
CBS-1251; CBS-1252 and CBS-1253 Extractor Plus Brewing System
FETCO PLUS® Commercial Beverage Equipment

CBS-1251 & CBS-1252 1½ gallon brewer with FETCO 1½ Gallon L4D dispensers (sold separately) CBS-2153 2 gallon Extractor Plus Brewers

CONTACT INFORMATION

FETCO® FOOD EQUIPMENT TECHNOLOGIES COMPANY

600 ROSE ROAD

LAKE ZURICH · IL · 60047-0429 · USA

ON THE WEB: fetco.cofee

©2020-2021 FETCO

fetco.com

PATENTS:https://www.fetco.com/pl,pages,patents,74.html

Coffee Brewer: CBS-1250 series

PHONE: (800) 338-2699 (US & CANADA) (847) 719-3000 (All Countries) FAX: (847) 719-3001
EMAIL:sales@fetco.com orders@fetco.com (to order parts and equipment) techsupport@fetco.com (all service queries)

P213 REV. 000

November 2021

TABLE OF CONTENTS
Specifications and Requirements .................................. 2 Electrical Configurations ................................................ 3 Enter Programming ........................................................ 5 Programing Menu Layout............................................... 5 Starting The Brew .......................................................... 6 A Program ...................................................................... 7 B General ....................................................................... 8 C Service Inputs ............................................................. 9 D Service Outputs .......................................................... 9 E Calibration................................................................. 10 F Service Menu ............................................................ 10

F Error Codes .............................................................. 11 G Counters................................................................... 12 H Save & Exit ............................................................... 13 Operator Training ......................................................... 14 Parts Diagram CBS-1251 ............................................ 18 Parts Diagrams CBS-1252 and CBS-1253.................. 20 CBS-1251 Tank Assembly........................................... 22 CBS-1252 and CBS1253 Tank Assembly ................... 24 Quick connect spray head assembly ........................... 26 Wiring Diagrams .......................................................... 27

Specifications and Requirements

Water Requirements:
CBS-1251; CBS1252 &1253: 20-75 psig, (138-517kPa) 1½gpm/(5.7lpm)

Electrical: See electrical configuration chart on page three. CBS-1250 series brewers use a terminal block for electrical connection

Water inlet fitting is a 3/8 inch male flare.

Tank Temperature, as set by factory:

Brewer supplied with inlet valve adaptor for BSP to SAE

200°F (93°C) inside water tank (at sea level)

CBS-2151 and CBS-2152

Brew Volume: First Batch 1½ gallons/ 6 liters

Second Batch 1 gallon/ 3.8 liters

Water supply: (Optimal) 100-150TDS

CBS-2153 -2 gallon

All beverage equipment must use filtered water.

Brew Volume: First Batch 2 gallons/ 7.6 liters

Second Batch 1 gallon/ 3.8 liters

Total Brew Cycle--Factory Default Settings CBS-2151 1½ gal Factory default setting First batch 1½ gal: 6:30 minutes=[5 minute brew time + 1.30 minute drip delay] + 10% Bypass

Second batch-1 gallon: 5:30 minutes=[4 minute brew time + 1.30 minute drip delay] + 0% Bypass

CBS-2152 1½ gal Factory default setting: First batch 1½ gal: 6:30 minutes=[5 minute brew time + 1.30 minute drip delay] + 15% Bypass Second batch-1 gallon: 5:30 minutes=[4 minute brew time + 1.30 minute drip delay] + 0% Bypass

CBS-2153-2 gallon Factory default setting: First batch 2 gal: 6:30 minutes=[5 minute brew time + 1.30 minute drip delay] + 15% Bypass Second batch-1 gallon: 5:30 minutes=[4 minute brew time + 1.30 minute drip delay] + 0% Bypass Brew-Process parameters are user controllable for: Brew Volume, Brew Time, Prewet Percent, Bypass, Prewet Delay, and Drip Delay

Weights and Capacities

Model

Height

CBS-1251 36 7/8 in

1½ gal

940 mm

CBS-1252 36 7/8 in

1½ gal

940 mm

CBS-1253

39 in

2 gal

99.1 mm

CBS-1251 & CBS-1252

Calibrated for

1½ gallons/ 6 liters

Width

Depth

12 3/4 in 22 1/2 in 320 mm 570 mm
21 7/8 in 22 1/2 in 550 mm 570 mm 21 7/8 in 22 1/2 in 550 mm 570 mm CBS-1253 Calibrated for 2 gallons/ 8 liters

Water tank Empty Filled Shipping

Shipping

capacity Weight Weight Weight

Dimensions

6.5 gallon 53 lbs 107 lbs 63 lbs

38" x 18" x 24"

24.4 L

24 kg 48.3kg 28.6 kg 96.5 x 45.7 x 61 cm

11.1 gallon 77 lbs 174 lbs 42.1 L 35.0 kg 78.9 kg

97 lbs 44 kg

38" x 24" x 27" 96.5 x 61 x 68.6 cm

11.1 gallon 82 lbs 180 lbs 97 lbs

40" x 24" x 27"

42.1 L 37.2 kg 81.6 kg 44 kg 102 x 61 x 68.6 cm

Filter Paper all models 15" X 5 ½ "­ standard Or use FETCO # F001

Brewers ship with plastic brew baskets. See page 25 for optional brew baskets

Rough-In Drawings

1201.00053.00 (CBS-1251) 1201.00052.00 (CBS-2152)

CBS-1251 Front

[Numbers in parenthesis are centimeters]

CBS-1252 Front

CBS-1253 Front

Side (all)

Back (all)

Go to fetco.com for the latest versions of all information Page 2 User Guide & Operator instructions P213e0 NOVEMBER 2021

Electrical Configurations

CBS-1251PLUS Single 1½ Gallon-6 Liter Coffee Brewers Domestic and International models Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz

Configuration Codes

Heater Configuration

Voltage

Phase Wires

KW

Amp Draw Brew-Volume/Hour

E1251US-1B230-PM110 2 X 3.0 kW 208-240

1

2+G 4.5-6.0 22.2-25.5 15.0 gal/57 liters

E1251US-1B230-MM110 2 X 3.0 kW 208-240

1

2+G 4.5-6.0 22.2-25.5 15.0 gal/57 liters

E1251IN-1B140-PM110 1 X 4.0 kW 200-240

1

2+G 2.8-4.0 14.4-17.2 10.6 gal/40.3 liters

E1251IN-1B150-PM110 1 X 5.0 kW 200-240

1

2+G 3.5-5.0 17.9-21.3 13.3 gal/50.4liters

E1251IN-1B230-PM110 2 X 3.0 kW 200-240

1

2+G 4.2-6.0 21.3-25.5 15.0 gal/57 liters

CBS-1251PLUS Single 1½ Gallon-6 Liter Coffee Brewers International models

Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz

Configuration Codes

Heater Configuration

Voltage

Phase Wires

KW

Amp Draw Brew-Volume/Hour

E1251NM-1B230-PM110
E1251KS- 1B230-MM110 E1251C E-1B230-PM110 E1251C E-1B230-PM110
.

2 X 3.0 kW
2 X 3.0 kW 2 X 3.0 kW 2 X 3.0 kW

208-240
220 23 0/ 40 0
230

1 2+G 4.2-6.0 21.3-25.5 15.0 gal/57 liters

1

2+G

5. 2

1

2L /N/P E

5. 6

1

L/N/ PE

5. 6

23.4

13.0 gal/49 liters

12.5

14.9 gal/ 56.4 liters

24.5

14.9 gal/ 56.4 liters

CBS-1252PLUS Twin 1½ Gallon-6 Liter Coffee Brewers Field configurable Domestic Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz

Configuration Codes E1252US-UB230-PM110 Selectable (1 or 3 phase)
Sold as 3 phase

Heater Configuration
2 X 3.0 kW
3 X 3.0 kW

Voltage
208-240 208-240

Phase Wires
1 2+G 3 3+G

KW
4.5-6.0 6.8-9.0

Amp Draw Brew-Volume/Hour
22.2-25.5 15.9 gal/60.4 liters 19.3-22.2 23.9 gal/90.6 liters

E1252US-UB250-PM110 2 X 5.0 kW

208-240

1 2+G 7.6-10.0 36.6-42.2 25.3 gal/97 liters

Selectable (1 or 3 phase)

Sold as 3 phase

3 X 5.0 kW

208-240

3

3+G 11.3-15.0 31.8-36.6 30.0 gal/114 liters

.

CBS-1252PLUS Twin 1½ Gallon-6 Liter Coffee Brewers Domestic and International models

Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz

Configuration Codes

Heater Configuration

Voltage Phase Wires

KW

Amp Draw Brew-Volume/Hour

E1252IN-1B230-PM110 2 X 3.0 kW 200-240 1 2+G 4.2-6.0 21.3-25.5 15.9 gal/60.4 liters E1252IN-1B250-PM110 2 X 5.0 kW 200-240 1 2+G 7.0-10.0 35.2-42.2 26.6gal/100.7liters

CBS-1252PLUS Twin 1½ Gallon-6 Liter Coffee Brewers International models Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz

Configuration Codes

Heater Configuration

Voltage Phase Wires

KW

Amp Draw Brew-Volume/Hour

E1252IN-3B330-PM110 3 X 3.0 kW

220/380 240/415

3

4+G 7.6-9.0 12.0-12.9 23.9 gal/90.6 liters

E1252IN-3B340-PM110 3 X 4.0 kW

220/380 240/415

3

4+G 10.1-12.0 15.8-17.2 30.0 gal/114 liters

E1252IN-3B350-PM110
E1252C E-3B330-PM110 E1252C E-3B350-PM110

3 X 5.0 kW
3 X 3.0 kW 3 X 5.0 kW

220/380 240/415

3

4+G 12.6-15.0 19.6-21.3 30.0 gal/114 liters

23 0/ 40 0

3

3L /N/P E

8. 3

12.5

23 0/ 40 0

3

3L /N/P E

13.8

20.5

22.1gal /83.6 liters 30.0 gal/ 114 lit ers

CBS-1252PLUS Twin 1½ Gallon-6 Liter Coffee Brewers Field configurable International

Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz

Configuration Codes

Heater Configuration

Voltage Phase Wires

KW

Amp Draw Brew-Volume/Hour

E1252NM-UB250-PM110 2 X 5.0 kW

208-240

1

2+G 7.6-10.0 36.6-42.2 26.6 gal/101 liters

Selectable (1 or 3 phase)

Sold as 3 phase

3 X 5.0 kW

208-240

3

3+G 11.3-15.0 31.8-36.6 30.0 gal/114 liters

.

CBS-1253PLUS Twin 2 Gallon-8 Liter Coffee Brewers continued on following page

Go to fetco.com for the latest versions of all information Page 3 User Guide & Operator instructions P213e0 NOVEMBER 2021

CBS-1253PLUS Twin 2 Gallon-8 Liter Coffee Brewers Field configurable Domestic Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz

Configuration Codes

Heater Configuration

Voltage

Phase Wires

KW

Amp Draw Brew-Volume/Hour

E1253US-UB230-PM110 2 X 3.0 kW 208-240

1

2+G 4.5-6.0 22.2-25.5 15.9 gal/60.4liters

Selectable (1 or 3 phase)

Sold as 3 phase

3 X 3.0 kW 208-240

3

3+G 6.8-9.0 19.3-22.2 23.9 gal/90.6liters

E1253US-UB250-PM110 2 X 5.0 kW 208-240

1

2+G 7.6-10.0 36.6-42.2 25.3 gal/97 liters

Selectable (1 or 3 phase)

Sold as 3 phase

3 X 5.0 kW 208-240

3

3+G 11.3-15.0 31.8-36.6 30.0 gal/114 liters

. CBS-1253PLUS Twin 2 Gallon-8 Liter Coffee Brewers Domestic and International models Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz

configuration Codes

Heater Configuration

Voltage

Phase Wires

KW

Amp Draw Brew-Volume/Hour

E1253US-1B230-PM110 2 X 3.0 kW 200-240

1

2+G 4.2-6.0 21.3-25.5 15.9 gal/60.4 liters

E1253US-1B250-PM110 2 X 5.0 kW 200-240

1

2+G 7.0-10.0 35.2-42.2 26.6gal/100.7liters

E1253IN-1B230-PM110 2 X 3.0 kW 200-240

1

2+G 4.2-6.0 21.3-25.5 15.9 gal/60.4 liters

E1253IN-1B250-PM110 2 X 5.0 kW 200-240

1

2+G 7.0-10.0 35.2-42.2 26.6gal/100.7liters

CBS-1253PLUS Twin 2 Gallon-8 Liter Coffee Brewers International models

Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz

Configuration Codes

Heater Configuration

Voltage

Phase Wires

KW

Amp Draw Brew-Volume/Hour

E1253IN-3B330-PM110

3 X 3.0 kW

220/380 240/415

3

4+G 7.6-9.0 12.0-12.9 23.9 gal/90.6 liters

E1253IN-3B340-PM110

3 X 4.0 kW

220/380 240/415

3

4+G 10.1-12.0 15.8-17.2 30.0 gal/114 liters

E1253IN-3B350-PM110

3 X 5.0 kW

220/380 240/415

3

4+G 12.6-15.0 19.6-21.3 30.0 gal/114 liters

E1253NM-1B250-PM110 2 X 5.0 kW 200-240

1

2+G 7.0-10.0 35.2-42.2 26.6gal/100.7liters

CBS-1253PLUS Twin 2 Gallon-8 Liter Coffee Brewers Field configurable International

Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz

Configuration Codes

Heater Configuration

Voltage

Phase Wires

KW

Amp Draw Brew-Volume/Hour

E1253NM-UB250-PM110 Selectable (1 or 3 phase)
Sold as 3 phase

2 X 5.0 kW 3 X 5.0 kW

208-240 208-240

1 2+G 7.6-10.0 36.6-42.2 25.3 gal/97 liters 3 3+G 11.3-15.0 31.8-36.6 30.0 gal/114 liters

EXAMPLE: SKU E1253US-UB230-PM110

SKU NUMBER IDENTIFICATION KEY

Product Line E
E=extractor

Level 1 2
12=PLUS Series

Family Region ID Phase Voltage Range

53US U

US =United States

1

51=

IN =

single side International

2

52= dual side

CE = CE

3

NM = NOM

U = 1 or 3

B A = 100-120 B = 200-240 C = 380-415 D = 440-480

53= dual side 2 gallon

X=120 or 240 Dual Voltage

#

Heaters

Individual Heater Wattage

Brew Basket

2

5

0

P

1

1.5

P=plastic

2

1.7

M=metal

3

2.3

3.0 4.0

5.0

Hot Water Faucet M
M=manual
A=automatic
N=None

Bypass

Brew Basket Locks

01

1

1=Yes 1=Yes

0=no

0=no

Power Cord 0
0=Terminal Block
1= NEMA 5-15P
2=NEMA 5-20P
3=NEMA 6-15P 4=NEMA 6-30P
5= CEE 7/7 Schuko
6=UK1-13P 7= AUSTRALIAN

Go to fetco.com for the latest versions of all information Page 4 User Guide & Operator instructions P213e0 NOVEMBER 2021

Enter Programming
Screens shown are for twin brewer. Single brewer will not have menu A4-A6.
There are seven menu groups-A-G . See the following pages for the batch parameter definitions and all settings for the brewer

TO ENTER PROGRAMMING
1-Turn brewer "OFF" from power switch 2-Turn power switch to "ON"
...Screen will initialize and then display digital process notifications
3-After Initialization-Red "STOP" Lamp turns on 4-Quickly press "STOP" button.

STOP BUTTON

CBS-1252 ver 2.0.210317

STOP

STOP

Batch Program A

STOP

STOP

When brewer is In PROGRAMMING MODE

-the screen will display:

On/OFF switch

|BATCH PRG|

located lower right on back of

|A (or B-H) |

brewer

-Illuminated LED indicates active keypad positions

Turn power OFF

See the following pages for batch parameter definitions and all settings for the brewer

Turn power ON Wait for red LED And quickly press STOP

button on front touch pane

Note: Only the left side buttons of a two sided brewer are used for programming

First screen will display for PROGRAMMING-A Scroll through main menu topics by pressing "STOP"
button.

Programing Menu Layout

A10 to A70

B10-B40

C10-C50

D10-D90

E10-E70

F10-F120

G1-G15

H10-H11

Batch Parameters General Settings Service Inputs

Service Outputs

Calibration

Service Menu

Counters

Exit and Save

|

|

|

|

|

|

|

|

A11 Brew Volume B1 Tank Temperature C1 LLC Probe D1 Heater SSR E1 Ready Temp. Offset F1 Firmware Ver. G1 Filter Used H1 Save Changes

|

|

|

|

|

|

|

|

A12 Brew Time B2 Brew at Temp C2 Basket Sensor D2 Fill Valve E2 LLC Sensitivity F2 Bootloader Ver. G2 Filter Life

H2

EXIT?

|

|

|

|

|

|

|

A13 Prewet Percent B4 Show Tank Temp C4 Tank Temperature D3 Lt Brew Valve E3 Slow Flow Compensate F3 Select Model G3 Filter Reset

|

|

|

|

|

|

|

A14 Prewet Delay B5 Units of Temp C5 USB Drive D4 Rt Brew Valve E4 Lt Brew Flow

F4 Option Bypass G4 Counter Reset

|

|

|

|

|

|

|

A15 Bypass Percent B6 Units of Volume C6 Keyboard Test D5 Lt Bypass Valve E5 Rt Brew Flow

F5 Option BB Lock G5 Choose Counter

|

|

|

|

|

|

A16 Drip Delay B7 Customer Name

D6 Rt Bypass Valve E6 Lt Bypass Flow F8 Backup to USB G10 Brewer Volume [T]

|

|

|

|

|

|

A20 Batch (2) Enabled B8 Customers Name

D7 Lt Basket Lock E7 Rt Bypass Flow F9 Restore from USB G11 Brewer Volume

|

|

|

|

|

A21 Brew Volume B9 Demo Mode

D8 Rt BasketLock

F10 Restore Defaults G12 LT Brews[T]

|

|

|

|

|

A22 Brew Time B10 Eco Mode

D12 LCD Brightness %

F11 Error Log G13 LT Brews

|

|

|

|

|

A23 Prewet Percent B11 Eco Idle Time

D13 LED Brightness %

F12 Erase Error Log G14 Rt Brews [T]

|

|

|

|

A24 Prewet Delay B12 Eco Idle Temp

F13 Service Phone# G15

Rt Brews

|

|

|

A25 Bypass Percent B13 Water Filter

F14 Override Lt BBS

See page 12

|

|

A26 Drip Delay

F15 Override Rt BBS

|

|

A30 Batch (3) Enabled

F16 Override Lt BBL

|

|

A90 Copy Batch

F17 Override Rt BBL

|

A91 Copy Batch: From

|

A92 PASTE: To

Top and middle batches are permanent SEE BOX on the following page for all "A" menus

Go to fetco.com for the latest versions of all information Page 5 User Guide & Operator instructions P213e0 NOVEMBER 2021

FETCO Ready to Brew

STOP

STOP

Starting The Brew
1. Turn the power switch "ON". (Twin Shown) 2. Prepare a brew basket with the correct size filter and appropriate amount of coffee. 3. Slide the brew basket completely into the rails. 4. Place a clean, empty, and preheated dispenser under the brew basket. 5. Select a batch & hold the corresponding BREW button in for 1 second to start 6. -STOP button will illuminate,
-Countdown time will display, -Selected BREW button will flash to indicate brew is in progress. -All other BREW buttons for that brew head will extinguish.

Ready
STOP

Brewing 5:30
STOP

7. When the brew cycle is finished,

STOP button will extinguish and the BREW button will continue to flash for the

amount of time programmed into the DRIP DELAY setting.

This indicates that coffee may still be dripping from the brew basket

For safety- do not remove brew basket until drip-out is complete.

Twin Brewer ready to brew. Example shown: Pressing top right brew position

Brewing-see #6 above

RECIPE Location map
Viewing and changing settings for the brew recipes is from the "A" screens with the controls in PROGRAMMING.

Single Side Models CBS-1231 Plus
STOP

DISPLAY STOP

Dual Side Models CBS-1232 Plus
STOP STOP

DISPLAY STOP

The uppermost button positions are permanent and will not display programming step A_0. The table above shows in position A20 that a button position can be made active or inactive. Position A1 does not display this step

BATCH A1
(permanent)
BATCH A2
(enabled by factory)
BATCH A3
(disabled by factory)

BATCH A4
(permanent)
BATCH A5
(enabled by factory)
BATCH A6
(disabled by factory)

The "A" menu is the most accessed menu. It is for programming the batch volumes, brewing parameters, enabling or disabling brew buttons. The "A" menu moves through the six positions(CBS-1252-) or three positions(CBS-1251+) by entering the menu and pressing the left stop button. (only the left side is active for programming the CBS-1252+)

The A menus [A1-3 or A1-6] correspond to batch buttons [3 or 6] on the touch panel
Access the A menus to PROGRAM & make changes to individual menu recipes. Menu settings can be copied Menu positions A1 and A4 [top position] are permanent. Menus A2, A3, A5, A6 can be removed by operator if desired

Batch Program A1

Brew Volume A1.10 3.80L +/-

Batch Enabled A2.00 YES -

Batch Enabled

A6.00

NO+

(Dual model shown)
Batches A1 to A6

STOP

STOP

STOP STOP

STOP

STOP

STOP

STOP

STOP

STOP

A1

A4

A2

A5

From A PRG screen Press button 1 to go into to the A menu access screens. Continue pressing button #1 to enter progamming for A1

From A11 screen Press STOP to scroll to A20. (A1&A4 are permanent)

From A20 screen Press STOP to scroll through the remaining (3 or 6) "A" menus. Make any changes as required

A3

A6

From A60 screen Scroll out to remaining A10-to A70 programming keys. See SAVE & EXIT in previous table

For single and twin Position of batch buttons for CBS-1252+
The CBS-1251+ single position brewer has one row of buttons

Go to fetco.com for the latest versions of all information Page 6 User Guide & Operator instructions P213e0 NOVEMBER 2021

A Program

Menu Features: Batch Parameters

The settings below are shown for the top batch on a single brewer top left button on a twin brewer. See how to access all A menus on the previous page. Below are the brew settings for default A1 & A2 batches

POSITION Program Items Factory set Default Programming Range Increments

Notes

A1.10

Batch Volume

1.5 gal 6.8 liters

0.51 to 2.00 gal 1.93 to 7.57L

0.01G 0.05L

A1.10

Batch Volume CBS-2153 only

2 gallons 9.1 liters

0.51 to 2.66 gal 1.93 to 10.1L

0.01G 0.05L

A1.20

Brew Time

5:00 minutes

2:00 ­ 12:00

0.30

Default total brew time is 6:30 minutes

A1.30
A1.40
A1.50 A1.60 This is a Safety Feature

Prewet Perc.

0%

Prewet Delay
(Pause after prewet completes)
Bypass Percent

0% [1:00 Min]
CBS-1251:10% CBS-1252/3:15%

0.00 ­ 25.0% [0:10 ­ 5:00] 0% ­ 40%

Drip Delay

1:30 mm:ss

0:30 ­ 6:00 Min.

1% 1:00 min
1%

Percentage of total brew volume The time between prewetting and start of brew cycle. This feature appears ONLY if Prewet >0:00 Diverts brewing water from brew process Time that brew basket remains locked during final drip-out Drip delay remains "ON" for 1:30 minutes if STOP is pressed during brew

A2.00

BATCH ENABLED

YES (Active)

Middle and Bottom batches A2,3,5,6

Batch on or off

Batches may be individually enabled, rewritten or deactivated

A2.10

Batch Volume

1.5 gal 6.8 liters

0.51 to 2.00 gal 1.93 to 7.57L

0.01G 0.05L

A2.10

Batch Volume CBS-2153 only

2 gallons 9.1 liters

0.51 to 2.66 gal 1.93 to 10.1L

0.01G 0.05L

A2.20

Brew Time

4.00 minutes

2:00 ­ 12:00

0.30

Default total brew time is 5:30 minutes

A2.30

Prewet Perc.

0%

0.00 ­ 25.0%

1%

Percentage of total brew volume

A2.40

Prewet Delay
(Brew pause after prewet completes)

0% [1:00 Min]

[0:10 ­ 5:00]

1:00 min

The time between prewetting and start of brew cycle. This feature appears ONLY if Prewet >0:00

A2.50

Bypass Percent

CBS-1251:0% CBS-1252&3: 0%

0% ­ 40%

1%

Diverts brewing water from brew process

A2.60

Time that brew basket remains

locked during final drip-out

This is a Drip Delay

1:30 mm:ss

0:30 ­ 6:00 Min.

Drip delay remains "ON" for

Safety

1:30 minutes if STOP is

Feature

pressed during brew

A30

Batch Enabled A30 YES NO +

NO-inactive (defaults to recipe A20 if activated)

Middle and Bottom batches A2,A3

Batch on or off

Batches may be individually enabled, rewritten or deactivated

A90

Batch Copy From Batch

A90

A90 1 (1-6)

Copy

A91

Copy To Batch?

A91

A91.1 (1-6)

PULSE BREW note. FETCO CBS-1200V+ brewers are factory programmed to pulse 2 cycles per minute brew time

Changing the brew time only will increase the pulses but will not change the volume of brew water delivered

.

Go to fetco.com for the latest versions of all information Page 7 User Guide & Operator instructions P213e0 NOVEMBER 2021

B General
POSITION Program Items

B1

Tank Temp.

B2

Brew at Temp.

B4

Show Tank Temperature

B5

Units of Measure TEMPERATURE

B6

Units of Measure VOLUME

B7

Customer Name

Brewer Operation Control Settings, Adjust Brew Flow Rate

Factory set Default Programming Range Increments

Notes

200°F-or-93° C NOTE: Equipment is Fahrenheit by default
"YES"
YES

77° to 97°C 170°F to 207°F
ON/OFF
YES/NO

F°-Fahrenheit

Fahrenheit/Celsius

G-Gallons

Gallons/Liters/Ounces

0.5°C 1.0°F YES/NO
C/F Gal/L/Oz

Chart to correct for high altitude below
SEE NOTE BELOW To display HW tank temperature on screen NOTE: Overwrites user settings (see page 9) NOTE: Overwrites user settings (see page 9)

Off

NO or YES

For name on screen

B8 B9 B10 B11 B12 B13

Customer Name Demo Mode Eco Mode Eco Idle Time Eco Idle Temp Water Filter

(only if above is "ON) DEMO ON/OFF On 1Hr 170°F OFF

Scroll with batch keys
ON/OFF 1-6 hours 158-176°F ON/OFF

A-Z;a-z;0-9
YES/NO 1 hour 1 degree YES/NO

16 characters total
Demonstrates the controls for training. Disables all
components in demo mode If Selected: Lowers hot
water tank temperature after preset time of inactivity
Time of inactivity to go into ECO Mode
Temperature that hot water tank is lowered to
Water filter life is accessed in G-Counters. This is user set and will display indicator
to change water filter

BREW AT TEMPERATURE DEFINITIONS DEFAULT: BREW AT TEMP: "ON"

(FACTORY DEFAULT FOR BREWER) "BREW at TEMP:

Hot water tank not

vv

vv

vv

at brew temp

-Batch will not start if tank temperature

setpoint.

is below set point. -Display will show "HEATING" and hot water tank temperature

Tank temp

HEATING 160°F

The "BREW START" entry buttons will not

STOP is not lit  STOP STOP

illuminate until the hot water tank reaches the

selected temperature.

BREW START

buttons not lit.

Controls allow both sides of dual brewer to and are disabled.

operate if one side has an ongoing brew

started and the second side brew is selected. When hot water

Notifications shown on screen:

tank temperature

TEXT: HEATINGTank above 87°C/189°F-will is at setpoint.

allow brew at low temperature.

Buttons will

Coffee flavor may be affected

illuminate and

TEXT: L. HEATTank above 77°C/170°F-

"READY" will be

will allow brew at low temperature.

displayed

Coffee flavor will be noticeably affected

USER SELECTABLE OPTION: BREW AT TEMP: OFF

(Not recommended) Unit will operate at lower temperature

Allows brewing at any temperature above 77°C/170°F

Below 70°C/170°F The brewer will display "HEATING"

Chart to correct for altitude for boiling point in tank water temperature.

[ft]

[m]

Suggested Boiling Setting[°F] point[°F]

Suggested Boiling Setting[°C] point [°C]

0

0

205 212.0

96

100.0

500 152 205 211.0

96

99.5

1000 305 200 210.1

93

98.9

2000 610 200 208.1

93

97.8

2500 762 200 207.2

93

97.3

3000 914 200 206.2

93

96.8

3500 1067 197 205.3

92

96.3

4000 1219 195 204.3

91

95.7

4500 1372 194 203.4

90

95.2

5000 1524 194 202.4

90

94.7

5500 1676 193 201.5

89

94.2

6000 1829 192 200.6

89

93.6

6500 1981 191 199.6

88

93.1

7000 2134 190 198.7

87

92.6

7500 2286 188 197.8

86

92.1

8000 2438 187 196.9

86

91.6

8500 2591 185 196.0

85

91.1

Go to fetco.com for the latest versions of all information Page 8 User Guide & Operator instructions P213e0 NOVEMBER 2021

C Service Inputs

POSITION Program Items

C1

LLC Probe continuity

C2

Brew Basket Sensor

C4

Tank Temperature

C5 USB Drive

C6 Keyboard Test

Brewer Sensors and Keypad

Factory set Default Programming Range Increments

Direct read

Tank water

850- LOW

resistance in TDS 1600-HIGH

L-YES R-YES

YES or NO

Direct read NO
Calibrate

Hot water tank temperature (not in use)
Checks buttons under membrane
cover

YES/NO

Notes Nominal values
Actual values
Follow directions on the touch screen

D Service Outputs

Test Valves and Heaters; Set screen brightness

POSITION Program Items Factory set Default Programming Range Increments

Notes

D1

Heater SSR Test

Press button 2 to test (button 1 stops test)

Activates heater Default is 10 sec..

Toggle +/OFF or ON

Energizes Heater(s) WARNING!
Service use only.

D2

Fill Valve Test

Press button 2 to test (button 1 stops test)

Activates valve Default is 10 sec.

Toggle +/OFF or ON

Press To Test

D3

LT (left) Brew Valve Test

(Press to test)

Activates valve Default is 10 sec.

Toggle +/OFF or ON

Runs valve to verify flow. NOTE: Have container
under brew basket.

D4

RT (right) Brew Valve Test

(Press to test)

Activates valve Default is 10 sec.

Toggle +/OFF or ON

Runs valve to verify flow. NOTE: Have container
under brew basket.

D5

LT (left) Bypass Valve Test

(Press to test)

Activates valve Default is 10 sec.

Toggle +/OFF or ON

Runs valve to verify flow. NOTE: Have container
under brew basket.

D6

RT (right) Brew Valve Test

(Press to test)

Activates valve Default is 10 sec.

Toggle +/OFF or ON

Runs valve to verify flow. NOTE: Have container
under brew basket.

LT (left)

D7

Brew Basket Lock (Press to test)

Test

Activates Brew Basket Lock

Toggle +/OFF or ON

Press To Test

RT (right)

D8

Brew Basket Lock (Press to test)

Test

Activates Brew Basket Lock

Toggle +/OFF or ON

Press To Test

Single series displays right side only Left Valve display is only for twin side brewer.

Adjust LCD screen

D12 LCD Brightness Brightness=90%

20-100%

5%

brightness only-Not for

LEDs under buttons

Adjust LED button

D13 LED Brightness Brightness=60%

20-100%

5%

brightness only-Not for

the screen display LCD

Go to fetco.com for the latest versions of all information Page 9 User Guide & Operator instructions P213e0 NOVEMBER 2021

E Calibration

Brewer Sensors and Keypad

POSITION Program Items Factory set Default Programming Range Increments

Notes

E1

Ready Temp. Offset

-3°F -2°C

-2° to -9°F -1° to -5° C

1°F Compensates output to measured 1°C temperature

E2

LLC Sensitivity

NORMAL
("NORMAL" for most water)

HIGH (Biased for reverse osmosis water or
very pure water)

NORMAL Liquid level control sensitivity.
High,1300 is for reverse HIGH osmosis water or very pure water.

E3

Slow flow rate from supply

ON

OFF/ON

Toggle +/- Trims fill system for low supply or YES or NO Flojet use

E4

LT Brew Valve flow rate:

0.95G

0.80-1.09G 1.30-1.90Liter

0.01G 0.05L

Adjusts flow rate

E5

RT Brew Valve flow rate:

0.95G

0.80-1.09G 1.30-1.90Liter

0.01G 0.05L

Adjusts flow rate

E6

LT Bypass Valve flow rate:

0.38G

0.31-0.44G 0.80-1.09Liter

0.01G 0.05L

Adjusts flow rate

E7

RT Bypass Valve flow rate:

0.38G

0.31-0.44G 0.80-1.09Liter

0.01G 0.05L

Adjusts flow rate

Use this formula to compensate for minor discrepancies in actual volume versus programmed volume.

See "PROGRAM" E4 & E5 For valve settings and calibration. Factory set brew valve flow rates are in liter/min

Current setting is the flow from E4,E5, E6, E7

Default Brew Valve Flow Rate--CBS-1250 Brewers

See table above for factory set default flow rates

CBS-1250

Gallons/minute

Range

ACTUAL VOLUME PROGRAMMED VOLUME

X

CURRENT SETTING

=

NEW SETTING

Left Brew Valve FR Right Brew Valve FR

0.95

0.80G to 1.09G

0.95

0.80G to 1.09G

Use this formula to determine the correct setting Set FR lower to increase volume; set higher to decrease volume.

F Service Menu

POSITION Program Items

F1

Display Firmware

F2

Display Bootloader

F3

Select Model

F4

Option Bypass

F5

Option BB Lock

F8

Backup to USB

F9

Restore From USB

F10 Restore Defaults

F11 Error Log

F12 Erase Error Log F13 Service Phone # F14 Override Lt BBS F15 Override Rt BBS F16 Override Lt BBL F17 Override Rt BBL

Software & Code View and Settings

Factory set Default Programming Range Increments

2.2.210720 Displays current version

2.0.210317
CBS1251;1252;1253 Will need reboot
Yes

Displays current version

Scroll to brewer model Save & Exit

CBS-1221 CBS-1251, CBS-1252 CBS-1241, CBS-1242 CBS-1251, CBS-1252 CBS-1261, CBS-1262 MBS-1221, MBS-1251 TBS-1221, MBS-1222

NO or YES

Yes

NO or YES

NO

Follow prompts

Saves settings

Applies settings from

USB

NO

NO/YES

Lists up to six codes, in order

1: ; 2: ;3:;4: ;5: ;6:
1=Newest/6=Oldest LAST six errors only

Newest=first Oldest=last

NO +

Toggle +/YES or NO

Enter as needed

NO

NO/YES

Toggle +/YES or NO

NO

NO/YES

Toggle +/YES or NO

NO

NO/YES

Toggle +/YES or NO

NO

NO/YES

Toggle +/YES or NO

Notes [6/2020] [6/2020]
NOTE: Overwrites all user settings
(See below)
Insert blank USB
Insert USB Will need reboot Reset to factory
See Error Codes Chart for references
FACTORY USE ONLY. DO NOT RESET Set phone contact
Disables brew basket sensor
Disables brew basket sensor
Disables brew basket lock
Disables brew basket lock

Go to fetco.com for the latest versions of all information Page 10 User Guide & Operator instructions P213e0 NOVEMBER 2021

F Error Codes

DO NOT CLEAR ERROR CODES UNTIL ERROR IS IDENTIFIED AND CORRECTED Contact factory or specialized personnel for error codes

Code Description

Possible Cause

Corrective Action

001

Software error-error on start up or corrupted software

002

Internal flash corrupted internal data memory malfunction

Improper start-up or shutdown Error found in cyclic redundancy check CRC

Restart , if still fault: reload software
Restart , if still fault: reload software If not corrected :replace board

050 Short-circuit in temperature probe Probe failure.

Replace probe.

051 Open temperature probe.
Initial Fill Error. 100 Initial fill time took longer than
expected after powering up.

Bad probe connection, or probe failure.
Water supply flow rate is too low.

Check all connections. Replace probe if necessary. Watch for short potting during brew cycle. Investigate cause of low flow rate. (Clogged water filter...)

101

Error on refill-. Tank did not refill within expected time. Water flow too slow from main.

Water supply flow rate is too low. (External to brewer.)

Watch for short potting during brew cycle. Investigate cause of low flow rate. (Clogged water filter...)

200 Heating flatline-Tank is boiling

Heater is on, temperature is High elevation correction. Bad heaters or

not rising/dropping

temperature probe or position

201

Heater open, high limit thermostat, or Solid State Relay (SSR) fault

202 Heater Shorted or Stuck SSR
255 Keyboard [HID] error NO BSKT Insert Brew Basket

Check that ohms range of heater are

Failure of heating element, SSR, high limit or low voltage

between 10-80; replace if not. Check for continuity, and if open replace
high limit devices. Check if permanently

closed and replace SSRs,if necessary.

Check that ohms range of heater are

Heater is off and equipment is heating. SSR is stuck "ON"

between 10-80; replace if not. Check if permanently closed SSR may be stuck in
ON mode-replace SSR. Test output on

solid state relay

Usually from longer than 10 se contact. Or faulty reassembly after service

Restart , if still fault: reload software. If mechanical: replace module

Brew basket must be in place

This is a SAFETY FEATURE

Insert brew basket into brewer rails to enable brewer

Go to fetco.com for the latest versions of all information Page 11 User Guide & Operator instructions P213e0 NOVEMBER 2021

G Counters Brewer Usage, Water Filter Usage, and Statistics

ROLE: [LT]=Permanent total for lifetime of machine; [R]=operator resettable; [User]=Input needed from operator

Position Counter Program items Role

Information

Increments

Notes

G1-G4 are for water filter maintenance. All beverage equipment must use filtered water and filter cartridges must be monitored for quality

G4

A, S, B Counter Reset

[User] NO

Toggle +/- ,Y or N Resets all resettable counters to zero

Basic=B

Stored brewer component activity..

G5

A, S, B Choose Counter

Factory set to BASIC Advanced=A

See column 2, Counters, to identify where

Statistical=S

counters are located.

G10-G15 Number of brews and volumes handled. Available in BASIC counter only (G5)

G10 G11

B

Brewer Volume

B

Brewer Volume

[LT] [R]

Dispensed volume

Gallons/Liters

Total of brews and hot water dispensed

G12

B

Lt Brews

G13

B

Lt Brews

[LT] Left side brew total [R] CBS-1252

Count

Total brews-Left side (CBS-1252 only)

G14

B

Rt Brews

G15

B

Rt Brews

[LT] [R]

Right side brew total CBS-1251&CBS-1252

Count

Total brews-Right side CBS-1251&CBS-1252

G20-G55 component use cycles and volumes handled. Available in ADVANCED counter only (G5)

G20

A

Fill Cycles

G21

A

Fill Cycles

[LT] Hot water tank refill [R] cycles

Count

Cycles of hot water tank refill

G22

A

Fill Volume

G23

A

Fill Volume

[LT] Total volume of water [R] for all brews

Gallons/Liters

Quantity of water for brews

G24 G25

A

Lt Brew Cycles

A

Lt Brew Cycles

[LT] Left brew valve [R] operation on/off

Count

Totalized cycles of valve operation (CBS-1252 only)

G26

A

Lt Brew Volume

[LT] Left brew valve flow through volume

Gallons/Liters

G27

A

Lt Brew Volume

[R]

G28 G29

A

Rt Brew Cycles

A

Rt Brew Cycles

[LT] Right brew valve [R] operation on/off

Count

G30 G31

A

Rt Brew Volume

A

Rt Brew Volume

[LT] Right brew valve [R] flow through volume

Gallons/Liters

G32 G33

A

Lt Bypass Cycles

[LT] Left bypass valve

A

Lt Bypass Cycles

[R] operation on/off

Count

G34 G35

A A

Lt Bypass Volume Lt Bypass Volume

[LT] Left bypass valve [R] flow through volume

Gallons/Liters

G36 G37

A A

Rt Bypass Cycles Rt Bypass Cycles

[LT] [R]

Count

Count

G38 G39

A A

Rt Bypass Volume Rt Bypass Volume

[LT] [R]

Right bypass valve flow through volume

Gallons/Liters

G48 G49

A

Lt BBL Cycles

A

Lt BBL Cycles

[LT] Left brew basket lock [R] flow through volume

Count

G50 G51

A

Rt BBL Cycles

A

Rt BBL Cycles

[LT] [R]

Right brew basket lock operation on/off

Count

G52 G53

A

Heater Cycles

A

Heater Cycles

[LT] ON/OFF switching for [R] heating elements

Count

G54 G55

A

Heater On Time

A

Heater On Time

[LT] Total ON time for [R] heating element

Hour

G80-G91 See illustration below for batch button positions Available in STATISTICAL counter only (G5)

G80 G81

S

Batch 10 Cycles

S

Batch 10 Cycles

[LT] Menu button selection [R] and activation count

Count

G82 G83

S

Batch 20 Cycles

S

Batch 20 Cycles

[LT] [R]

Menu button selection and activation count

Count

G84 G85

S

Batch 30 Cycles

S

Batch 30 Cycles

[LT] [R]

Menu button selection and activation count

Count

G86 G87

S

Batch 40 Cycles

S

Batch 40 Cycles

[LT] [R]

Menu button selection and activation count

Count

G88 G89

S

Batch 50 Cycles

S

Batch 50 Cycles

[LT] [R]

Menu button selection and activation count

Count

G90 G91

S

Batch 60 Cycles

S

Batch 60 Cycles

[LT] [R]

Menu button selection and activation count

Count

Totalized volume through left valve (CBS-1252 only)
Totalized cycles of valve operation CBS-1251&CBS-1252 Totalized volume through right valve CBS-1251&CBS-1252 Totalized cycles of valve operation (CBS-1252 only) Totalized volume through left valve (CBS-1252 only) Totalized cycles of valve operation CBS-1251&CBS-1252 Totalized volume through right valve CBS-1251&CBS-1252 Totalized cycles of brew basket lock operation (CBS-1252 only) Totalized cycles of brew basket lock operation CBS-1251&CBS-1252
Totalized cycles of heater switching
Totalized heater ON time in hours
Total brews-left side top button (CBS-1252 only) Total brews-left side middle button (CBS-1252 only) Total brews-left side bottom button (CBS-1252 only) Total brews-right side top button CBS-1251&CBS-1252 Total brews-right side middle button CBS-1251&CBS-1252 Total brews-right side bottom button CBS-1251&CBS-1252

Go to fetco.com for the latest versions of all information Page 12 User Guide & Operator instructions P213e0 NOVEMBER 2021

H Save & Exit

Saving changes and exiting PROGRAMMING

The brewer will save changes only from the "H" menu. DO NOT reboot brewer or toggle ON/OFF-exit as below.

TO EXIT PROGRAMMING & HOW TO SAVE CONTROL SETTING CHANGES

HOW TO SAVE CHANGES AND EXIT-The brewer is in PROGRAMMING mode.

Programming A-H

EXIT

A-H+

H

EXIT

SAVE

EXIT

NO +

H

YES -

H1

NO +

H

YES -

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

1

1

1

1

1

2

2

2

2

2

3

3

3

3

3

From any screenPress STOP button until the EXIT ("H")
screen appears

From the "H" screen Press button 2 to toggle to the EXITYES screen

From EXIT screen Press button 1 to toggle to the SAVE
screen

From SAVE screen Press button 2, to toggle to the SAVE-
YES screen

To SAVE and EXIT Press button 1 to
SAVE your changes and EXIT

NOTE: User Settings will be erased and overwritten to factory default settings by the following five programming changes

1) When setting or changing units of display for the tank temperature (F Fahrenheit or C Celsius). (SETTING B4)

2) When setting or changing units of display for the volume (L liters, G gallons). 3) When setting brewer model The software sets equipment to brewer defaults

(SETTING B5) (SETTING F3)

4) When loading from USB (Reprograms settings) 5) When restoring defaults (Reloads to defaults )

(SETTING F9) (SETTING E10)

Go to fetco.com for the latest versions of all information Page 13 User Guide & Operator instructions P213e0 NOVEMBER 2021

Operator Training
Review the operating procedures with whoever will be using the brewer. Pay particular attention to the following areas: 1. Always pre-heat the dispensers before the first use of each day by filling them halfway with hot water and letting
them stand for at least 5 minutes. 2. Do not remove the brew basket from a coffee brewer until it has stopped dripping. 3. Make sure the dispenser is empty before brewing into it. 4. Show how to attach covers, close, and or secure the dispensers for transporting. 5. Show the location and operation of the water shut off valve as well as the circuit breaker for the brewer. 6. Steam from the tank will form condensation in the vent tubes. This condensation will drip into and then out of the
brew baskets. Up to 1/4 cup/118cc discharging overnight is possible. Place an appropriate container under each brew basket when not in use. 7. We recommend leaving the power to the brewer on overnight. The water tank is well insulated and very little electricity is used to keep the tank hot. Leaving the brewer in the "ON" position will also avoid delays at the beginning of shifts for the brewer to reach operating temperature.
Cleaning & Maintenance
After Each Brew: 1. Dispose of grounds and rinse brew basket. 2. Never strike a brew basket or hit it against a hard surface.
This will damage the brew cone, and may damage the brew basket support rails 3. Rinse dispensers before reuse. Every Day: 1. Wash brew basket with hot sudsy water. 2. Pull CSD from the spray head, it is magnetically attached. Use gloves or a heavy towel. 
Wash off any film and reattach. Use vinegar if limescale filming is present. 3. Clean dispensers with hot suds water and a brush, rinse and air dry. 4. Use only a soft cloth and hot suds on the outside to avoid scratches. Never use abrasives that will scratch surface. Weekly 1. Use a commercial coffee dispenser cleaner such as URNEXTM, TABZTM, DIP-ITTM or Squeak 'n CleanTM. 2. Carefully Follow the instructions supplied with the cleaning product 3. Never use spray cleaners, solvent, solvent based cleaner or petroleum based polish anywhere on dispensers Warning 1. Turn off power before any cleaning procedure, including wiping the exterior for appearance reasons. 2. Dry the exterior, especially the face panel, before turning on power. 3. Do not apply any type of spray cleaner on the face panel of this equipment. 4. Never use solvent or solvent-based cleaner or petroleum based polish anywhere on this equipment. 5. Dry the face of the touch pad before turning on power 6. Do not electrically energize this equipment or attempt operation without all covers in place and all screws fastened. 7. Unplug machine before disassembly or servicing. Safety Notes 1. Professional installation is required. This appliance is manufactured only for commercial use 2. Operational requirements and maintenance for commercial cooking appliances differ from household appliances. 3. Operators must be trained for this equipment and must understand the use, maintenance and hazards. 4. Access to the service area is restricted to persons having safety/hygiene knowledge and practical experience of the
coffee brewer. This appliance must be installed in locations where it can be overseen by adult trained personnel. 5. Do not attempt to move hot beverage equipment once it is filled. Drain equipment before moving. 6. FETCO commercial coffee brewers prepare large amounts of coffee or tea in a single batch using very hot water 7. Commercial coffee brewers provide very hot water from the spray head, brew basket and faucet when it is pulled. 8. Coffee brewers may continue to dispense very hot water from the mechanically operated faucet after the electronic
touchpad is completely disabled by turning off the power switch on the lower back of the unit or unplugging the unit. 9. For safety, the brewer control locks the brew basket for 6.0 minutes after starting the brew. 10. Never attempt to defeat the factory set (default) time that the brew basket is locked for safety from start of brew.
Keep these instructions for training and future reference.
Go to fetco.com for the latest versions of all information Page 14 User Guide & Operator instructions P213e0 NOVEMBER 2021

(For Qualified Service Technicians Only)
General:
1. If not installed correctly by qualified personnel, the brewer will not operate properly, and damage may result. 2. Utilize only qualified beverage equipment service technicians for service and installation. 3. Always have an empty dispenser under spray head of all coffee brewing equipment-including when at idle 4. Damages resulting from improper installation are not covered by the warranty and will void the warranty.
Below are the key points to consider before installation:

Electrical:
1. All CBS_Series brewers require an electrical ground wire. Installation without grounding is dangerous. 2. Note Equipotentiality Terminal, if present, (To identify the terminals which, when connected together, bring the various parts
of equipment or of a system to the same potential, not necessarily being the earth (ground) potential, e.g. for local bonding.) 3. Verify voltages, polarity, circuits, and circuit breaker access before attaching equipment. 4. Brewers in this series wire differently in regard to a neutral wire. Review the wire diagrams. 5. The electrical diagram is located in the User's Guide and online at www.fetco.com. 6. Make sure of the tight grounding of the equipment and use the external ground bolt. 7. The installation must comply with applicable federal, state, and local codes having jurisdiction at your location.
Check with your local inspectors to determine what codes will apply.
See wiring diagrams on pages 29-31 for connections

Plumbing:
1. North America: All installations must comply with applicable federal, state, or local plumbing codes. 2. All Others: The water and waste piping and connections shall comply with the International Plumbing Code,
International Code Council (ICC), or to the Uniform Plumbing Code (IAPMO). 3. Install a backflow prevention device. Most municipalities require a recognized backflow preventer
Usable on all hot beverage and cold beverage equipment is a WATTS® SD-2 or SD-3. WATTS spring loaded double check valve models are accepted by most zoning authorities. The check valve should be as close to the water supply inlet of the beverage equipment as possible 4. All beverage equipment must use a water filter. A finishing carbon filter is preferred 5. Install the filter unit after a water shutoff valve and in a position to facilitate filter replacement. 6. The water line and newly installed filter cartridge must be flushed thoroughly prior to connecting it to the brewer to prevent debris from contaminating the machine 7. Verify that the water line will provide a flow rate of at least 1½ gpm/(5.7lpm) per minute and the water pressure is between 20-75 psig (138-517kPa) before making any connections 8. Only use the supplied factory fitting to attach water supply line to brewer (shipped in brew basket) 9. The suppled fitting is a 3/8" flare/compression fitting for 1/4" supply line. Other adaptors may be substituted. 10. Hand tighten the factory fitting when connecting the stub on the brewer. This will reduce stress on the internal connections and reduce the possibility of leaks developing after the install has been completed

Tank Drain
The water tank must be drained before maintenance procedures, and when the unit is to be relocated or shipped. Drain is for service use only and must not be permanently connected. NOTE: Never plumb a water line to the drain.
1.Disconnect power and water to unit. DANGER: Ensure that all utility connections to the brewer are broken. 2.Move the unit near a sink or obtain a container large enough to hold four gallons of water. Note: The CBS-1251 hot water tank when full holds 6.5 gallons; the CBS-1252 11.1 gallons. 3.Remove the front panel and tank cover and allow the tank to cool to a safe temperature 4.The tank drain line and clamp are located inside-under the hot water tank. Pinch the drain line clamp to close 5.Locate the fill valve against the back wall, using pliers, loosen the hose clamp and move it back over the tube. Note Do not loosen the hose clamp to the bottom of the hot water tank 6.Crimp the tube an inch or two away from the drain plug to prevent water from flowing and pull it off the valve. 7.Pull the tube end out of the brewer and position over sink or bucket. 8.Release the crimped tube and hose clamp and allow the water to flow into the sink or container. 9.Reverse steps 4-8 when service is complete. Ensure pinch clamp is open and hose clamps are in place.

Brewer

Hot Water Tank Capacity

OPEN Leave open for use

CBS-1251 Single

6.5 gal 24.4 liter

PINCH SHUT

CBS-1252 Twin

11.1 gal 42.1 liter

To drain tank & service brewer

AI!

Go to fetco.com for the latest versions of all information Page 15 User Guide & Operator instructions P213e0 NOVEMBER 2021

Installation safety and hygiene directions-For International and CE equipment
1. Access to the service area is restricted to persons having safety/hygiene knowledge and practical experience of the coffee brewer. This appliance must be installed in locations where it can be overseen by trained personnel. 2. For proper operation, this appliance must be installed indoors where the temperature is between 10°C/50°F to 35°C/95°F. Drain and remove all liquid from equipment and lines if exposed to freezing temperatures. 3. All commercial cooking equipment, including this unit, is not intended for use by children or persons with reduced physical, sensory, or mental capabilities. Ensure proper supervision of children and keep them away from the unit. 4. Children should be supervised to ensure that they do not play around hot beverage equipment. 5. This unit must be installed and serviced by qualified personnel only. 6. Installation must conform to all local electrical and plumbing codes. Installation by unqualified personnel will void the unit warranty and may lead to electric shock or burn, as well as damage to unit and/or its surroundings. 7. If the power cord requires repair or replacement-it must be performed by the manufacturer or authorized service personnel with the specified cord only from the manufacturer in order to avoid a hazard. 8. Review the dimensions for the unit and verify that it will fit properly in the space intended for it. Verify that the counter or table will support the total weight of the brewer and dispensers when filled (See: Technical Data). 9. Place the brewer on the counter or stand. When the brewer is in position, level it front to back as well as side-toside by adjusting the legs. 10. Brewers will need a sturdy supported surface for operation. Do not move brewers when filled. 11. Do not tilt appliance more than 10° to insure safe operation. 12. Unit is for protected indoor use only. Do not steam clean or use excessive water on unit. 13. This unit is not "jet-proof" construction. Do not pressure wash or use jet spray to clean this unit. 14. The unit is not waterproof-do not submerge or saturate with water.
Equipment exposed to flood and contaminated must not be used due to electrical and food safety. Do not operate if unit has been submerged or saturated with water.
Labels and warnings for hot beverage equipment For BACK PANEL of equipment (1046.00035.00)
Go to fetco.com for the latest versions of all information Page 16 User Guide & Operator instructions P213e0 NOVEMBER 2021

Complete Brew Basket
Brew basket handle plug for polymeric brew baskets is available in optional colors.

Part Number B015280BN2BK 0.280" diameter hole Part Number Plug Insert color 1023.00195.00 BROWN PLUG, BB HANDLE 1023.00194.00 BLACK PLUG, BB HANDLE 1023.00190.00 RED PLUG, BB HANDLE
1023.00191.00 GREEN PLUG, BB HANDLE
1023.00192.00 ORANGE PLUG, BB HANDLE 1023.00180.00 BLUE PLUG, BB HANDLE

Stainless Steel Brew Basket

Ref#

Part Number

Description

Complete Stainless



B001280B1

Steel Brew basket no clips

(Standard)

Complete Stainless

B002280B1 Steel Brew basket with

clips (Optional)

1

1112.00058.00 BB brew cone WLDMNT

2

1046.00025.00

BREW BASKET WARNING LABEL

3

1082.00040.00

SCREW, 1/4-20 X .5, FL HD, PH., W/NYLN

4

1009.00005.00 WIRE BASKET

5
6
Optional colored handle Optional colored handle Optional colored handle

1102.00064.00 1009.00003.00 1102.00065.00 1102.00066.00 1102.00067.00

HANDLE W/MAGNET ASY, BLACK CLIP, WIRE BASKET, NOTE!: Requires 4 clips
HANDLE W/MAGNET ASY, RED
HANDLE W/MAGNET ASY, GREEN
HANDLE W/MAGNET ASY, ORANGE

Go to fetco.com for the latest versions of all information Page 17 User Guide & Operator instructions P213e0 NOVEMBER 2021

Parts Diagram CBS-1251
Drawing 1101.00572.00 Parts CBS-1251
#6 Part Number1102.00471.00 ELECTRICAL COMPONENT LATTICE
Go to fetco.com for the latest versions of all information Page 18 User Guide & Operator instructions P213e0 NOVEMBER 2021

Ref 1 2 3 4 5 6 6 REF 6-1 6-2 6-3 6-4 6-5 6-6 6-7 6-8 6-9 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 34 34 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65

Qty Part Number

1

1111.00100.00

6

1084.00051.00.

1

1102.00480.00

2

1082.00029.00

2

1082.00058.00

1

1102.00471.00

1

Reference

1

1023.00350.00

1

1052.00023.00

2

1082.00056.00

2

1058.00024.00

4

1057.00043.00

2

1082.00010.00

1

1052.00059.00

2

1082.00020.00

2

1058.00055.00

1

1097.00171.00

1

1023.00390.00

1

1102.00450.00

2

1024.00107.00

1

1024.00108.00

2

1024.00106.00

1

1023.00343.00

2

1023.00342.00

10

1083.00010.00

10

1084.00006.00

1

1024.00098.00

1

1086.00004.00

1

1102.00243.00

2

1065.00009.00

1

1044.00012.00

12

1084.00011.00

1

1025.00058.00

1

1086.00009.00

4

1086.00003.00

1

1112.00529.00

1

1001.00402.00

1

1001.00403.00

12

1082.00017.00

1

1046.00035.00

1

1402.00097.10

1

1046.00003.00

1

1041.00033.00

1

1104.00165.00

1

1104.00166.00

1

1104.00167.00

1

1104.00168.00

1

B015280BN2BK

1

B001280B1BB

1

B002280B1BB

1

1402.00037.10

1

1402.00039.10

1

1402.00121.10

1

1024.00111.00

1

1023.00362.00

1

1013.00131.00

1

1023.00348.00

1

1071.00055.00

1

1084.00048.00

1

1003.00370.00

1

1025.00120.00

2

1024.00051.00

1

1023.00349.00

1

1023.00369.00

1

1057.00076.00

1

1029.00042.00

1

1023.00344.00

1

1102.00219.00

6

1083.00009.00

2

1084.00010.00

1

1003.00259.00

4

1073.00007.00

1

1086.00008.00

1

1086.00031.00

1

1086.00032.00

1

1044.00013.00

1

1052.00027.00

4

1084.00012.00

Description Drawing 1101.00572.00, CBS-1251 WELDMENT BODY, CBS-2251 NUT, HEX LOCKWASHER, #8-32, 18-8 ST. STL FRONT PANEL ASSY, SINGLE, PLUS SERIES SCREW, #6 X 3/8 LG, TRUSS HD PHIL, SHEET MTL SCREW, # 8-32 X 5/8, FLAT HD, PH, 18-8 SS ELECTRICAL COMPONENT LATTICE, NEXT GEN XV+ ELECTRICAL COMPONENT LATTICE, NEXT GEN XV+ ELECTRICAL MOUNTING LATTICE, COMMON EUROSTRIP HE16 TERM. BLOCK, 4 POLE, 63 AMP, 18-8 AWG SCREW, # 8-16 x 1" PAN HD PHIL, THREAD FORMING, FOR PLASTICS, 18-8 SS SWITCH, POWER, DOUBLE POLE, 16A, 125/250 VAC SOLENOID VALVE, 5.5L/min, 180 DEG, 24VDC SCREW, PAN HD. PHIL. MACH., M4x10 ZINC-PLATED POWER SUPPLY, 90-264VAC/24VDC, 2.25A SCREW, #6 X 5/8, TRUSS HD PHIL, SHEET MTL USB CONNECTOR ADHESIVE, RGB LED BAR LENS, LIGHT BAR, BLACK QUICK CONNECT SRAYHEAD ASSEMBLY, BASIC [See Page 24 for expanded drawing] O-RING, 1 3/16" OD X 1 1/16" ID X 1/16" TH, BYPASS SEAL O-RING, 5 11/16"OD X 5 1/2" ID X 3/32" TH, BREW SEAL O-RING, 13/16"OD X 11/16"ID X 1/16" TH, FOR QUICK CONNECT VENT INSERT, QUICK CONNECT QUICK CONNECT CLIP WASHER, #10 SCREW W/NEOPRENE-BONDED SEAL NUT, 8-32 18-8 HEX MACHINE SCREW VENT TUBE, CBS- EXTRACTOR SERIES BUSHING, SNAP, 1" MOUNTING HOLE ADAPTER ASSY, 3/4" BSP x 1/4" NPT x 3/8" TUBE GROUND LUG CONNECTOR, 14-2 AWG, ALUMINUM LABEL GROUND, CE NUT, CLIP ON (J-NUT), #6-32, 22-20 GA., BLK-PH FINISH TUBE, 9/16"OD X 5/16"ID X 25.00"LG CLAMP, 3/4" MAX TUBE OD FLOW CONTROL UNICLAMP, 15.9 HOSE OD CLAMP WELDMENT FRONT COVER, CBS-2250 COVER TOP, CBS-2251 COVER, UPPER BASE, CBS-2251 SCREW, TRUSS HD. PHIL. MACHINE, # 6-32 X 1/2 LG. LABEL, WARNING "TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE" WIRE HARNESS, CBS-1240/50, LOW AMP, UNIVERSAL LABEL, CSD WARNING, 1.5" X 5.0" BLACK EXTRACTOR PLUS LABEL, LASER ENGRAVED TANK ASSEMBLY, CBS-2251, 1 X 4KW/240VAC [See additional pages for expanded drawing] TANK ASSEMBLY, CBS-2251, 1 X 5KW/240VAC TANK ASSEMBLY, CBS-2251, 2 X 2.3KW/240VAC TANK ASSEMBLY, CBS-2251, 2 X 3KW/240VAC BREW BASKET ASSY, 16" X 6", 0.280" DIA HOLE, BROWN PLUG ASSY, 16" X 6", 0.280 DIA HOLE, BLACK ASSY, 16" X 6", 0.280" DIA HOLE, BLACK HARNESS HIGH AMP, CBS-2232/42/51, UL HARNESS HIGH AMP, CBS-2231/41/51, UL WIRE HARNESS ADDITION, HIGH AMP, EMI FILTER, 2-POLE, CE GROMMET, SILICONE, W/ POSITION TABS FITTING VENT, ELBOW, .375" X .375", SELF POSITIONING TUBE, 304SS, .625OD X .065 WALL X 11-1/2" LG. HOT WATER INSERT, MANUAL FAUCET FAUCET, HOT WATER, PSC-BR-8, WITH FLAT AND STEM JAM NUT, 1/2-20 UNF, NICKEL PLATED BRASS HOT WATER INSERT LOCK TUBE, 9/16"OD X 5/16"ID X 13.00"LG GROMMET, SILICONE, BLANK HOT WATER INSERT, NO FAUCET ORIFICE INSERT, QUICK CONNECT, 3/16" HOLE VALVE ASSEMBLY, COMPLETE, NG, DELTROL BYPASS L-TUBE, SILICONE, 2200 SINGLE SERIES PLUG INSERT, QUICK CONNECT ASSEMBLY, BB LOCKER, 24VDC WASHER, #6 SCREW , INTL TOOTH LOCKWASHER NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED BRACKET, BREW BASKET LOCK COVER LEG, FLANGE FOOT, 4" HIGH CONNECTOR, CLAMP, NON-METALLIC CABLE, 3/4" SKINTOP, 3/4" NPT, 0.354" - 0.630" DIA CABLE, BLK LOCKNUT, SKINTOP, 3/4" NPT, BLACK HEX LABEL EQUIPOTENTIALITY, CE EMI FILTER, THREE LINE 30A, 250/440VAC NUT, HEX, #6-32 MACHINE SCREW

Go to fetco.com for the latest versions of all information Page 19 User Guide & Operator instructions P213e0 NOVEMBER 2021

Parts Diagrams CBS-1252 and CBS-1253
Parts lists for CBS-1252 1-1/2 gallon Drawing 1101.00573.00 CBS-1252 2 gallon Drawing 1101.00592.00
#6 Part Number1102.00471.00 ELECTRICAL COMPONENT LATTICE
Go to fetco.com for the latest versions of all information Page 20 User Guide & Operator instructions P213e0 NOVEMBER 2021

REF 1 1 2 3 4 5 6 REF 6-1 6-2 6-3 6-4 6-5 6-6 6-7 6-8 6-9 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35 35 35 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67

QTY 1 1 6 1 2 2 1 1 1 2 2 4 2 1 2 2 1 1 2 4 2 3 2 4 20 20 2 2 1 2 1 12 1 1 4 1 1 1 12 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 3 1 1 1 1 1 1

Part number 1111.00099.00 1111.00114.00 1084.00051.00 1102.00470.00 1082.00029.00 1082.00058.00 Reference 1023.00350.00 1052.00023.00 1082.00056.00 1058.00024.00 1057.00043.00 1082.00010.00 1052.00059.00 1082.00020.00 1058.00055.00 1097.00171.00 1023.00390.00 1102.00450.00 1024.00107.00 1024.00108.00 1024.00106.00 1023.00343.00 1023.00342.00 1083.00010.00 1084.00006.00 1024.00098.00 1086.00004.00 1102.00243.00 1065.00009.00 1044.00012.00 1084.00011.00 1025.00058.00 1086.00009.00 1086.00003.00 1112.00529.00 1001.00352.00 1001.00399.00 1082.00017.00 1046.00035.00 1402.00097.10 1402.00097.11 1046.00003.00 1041.00033.00 1104.00160.00 1104.00161.00 1104.00162.00 1104.00163.00 1104.00164.00 1402.00112.10 1402.00120.10 1022.00032.00 1066.00003.00 B015280BN2BK B001280B1BB B002280B1BB 1024.00111.00 1023.00362.00 1013.00131.00 1023.00348.00 1071.00055.00 1084.00048.00 1003.00370.00 1025.00120.00 1024.00051.00 1023.00349.00 1023.00369.00 1057.00076.00 1023.00344.00 1029.00042.00 1102.00219.00 1003.00259.00 1083.00009.00 1084.00010.00 1073.00007.00 1086.00008.00 1086.00031.00 1086.00032.00 1044.00013.00 1052.00050.00 1084.00012.00

Description

Drawing 1101.00573.00, 1101.00059.00 Parts CBS-1252 and applies to CBS-1253

WELDMENT BODY, CBS-2252 1½ gallon brewer only

WELDMENT BODY, CBS-2252 2 gallon brewer only

NUT, HEX LOCKWASHER, #8-32, 18-8 ST. STL.

FRONT PANEL ASSY, DOUBLE, PLUS SERIES

SCREW, #6 X 3/8 LG, TRUSS HD PHIL, SHEET MTL

SCREW, # 8-32 X 5/8, FLAT HD, PH, 18-8 SS

ELECTRICAL COMPONENT LATTICE, NEXT GEN XV+

ELECTRICAL MOUNTING LATTICE, COMMON

EUROSTRIP HE16 TERM. BLOCK, 4 POLE, 63 AMP, 18-8 AWG

SCREW, # 8-16 x 1" PAN HD PHIL, THREAD FORMING, FOR PLASTICS, 18-8 SS

SWITCH, POWER, DOUBLE POLE, 16A, 125/250 VAC

SOLENOID VALVE, 5.5L/min, 180 DEG, 24VDC

SCREW, PAN HD. PHIL. MACH., M4x10 ZINC-PLATED

POWER SUPPLY, 90-264VAC/24VDC, 2.25A

SCREW, #6 X 5/8, TRUSS HD PHIL, SHEET MTL

USB CONNECTOR

ADHESIVE, RGB LED BAR

LENS, LIGHT BAR, BLACK

QUICK CONNECT SRAYHEAD ASSEMBLY, BASIC [See Page 24 for expanded drawing]

O-RING, 1 3/16" OD X 1 1/16" ID X 1/16" TH, BYPASS SEAL

O-RING, 5 11/16"OD X 5 1/2" ID X 3/32" TH, BREW SEAL

O-RING, 13/16"OD X 11/16"ID X 1/16" TH, FOR QUICK CONNECT

VENT INSERT, QUICK CONNECT

QUICK CONNECT CLIP

WASHER, #10 SCREW W/NEOPRENE-BONDED SEAL

NUT, 8-32 18-8 HEX MACHINE SCREW

VENT TUBE, CBS- EXTRACTOR SERIES

BUSHING, SNAP, 1" MOUNTING HOLE

ADAPTER ASSY, 3/4" BSP x 1/4" NPT x 3/8" TUBE

GROUND LUG CONNECTOR, 14-2 AWG, ALUMINUM

LABEL GROUND, CE

NUT, CLIP ON (J-NUT), #6-32, 22-20 GA., BLK-PH FINISH

TUBE, 9/16"OD X 5/16"ID X 25.00"LG

CLAMP, 3/4" MAX TUBE OD FLOW CONTROL

UNICLAMP, 15.9 HOSE OD CLAMP

WELDMENT FRONT COVER, CBS-2250 1½ gallon brewer and 2 gallon brewer

COVER, UPPER BASE, CBS-1152 EXTRACTOR V+

COVER TOP, CBS-2252

SCREW, TRUSS HD. PHIL. MACHINE, # 6-32 X 1/2 LG.

LABEL, WARNING "TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE"

WIRE HARNESS, CBS-1240/50, LOW AMP, UNIVERSAL

WIRE HARNESS ADDITION, CBS-1252, LOW AMP, UNIVERSAL

LABEL, CSD WARNING, 1.5" X 5.0"

BLACK EXTRACTOR PLUS LABEL, LASER ENGRAVED

TANK ASSEMBLY, CBS-2252, 3 X 3KW/240VAC [See additional pages for expanded drawing]

TANK ASSEMBLY, CBS-2252, 2 X 3KW/240VAC [See additional pages for expanded drawing]

TANK ASSEMBLY, CBS-2252, 3 X 4KW/240VAC [See additional pages for expanded drawing]

TANK ASSEMBLY, CBS-2252, 3 X 5KW/240VAC [See additional pages for expanded drawing]

TANK ASSEMBLY, CBS-2252, 2 X 5KW/240VAC [See additional pages for expanded drawing]

WIRE HARNESS, CBS-1252/61, HIGH AMP, 1 OR 3PH, 3 HEATERS, UL

WIRE HARNESS, 3 HEATER, HIGH AMP, 3L-N-PE, 220/380-240/415, INTL/CE

SLEEVE, Ø.50 x 2.0" LG. x 1.50" SLOT

CABLE TIE, 3-7/8" LG., BLACK

BREW BASKET ASSY BLACK, 16" X 6", 0.280" DIA HOLE, BROWN PLUG

ASSY, 16" X 6", 0.280 DIA HOLE, BLACK

ASSY, 16" X 6", 0.280" DIA HOLE, BLACK

GROMMET, SILICONE, W/ POSITION TABS

FITTING VENT, ELBOW, .375" X .375", SELF POSITIONING

TUBE, 304SS, .625OD X .065 WALL X 11-1/2" LG.

HOT WATER INSERT, MANUAL FAUCET

FAUCET, HOT WATER, PSC-BR-8, WITH FLAT AND STEM

JAM NUT, 1/2-20 UNF, NICKEL PLATED BRASS

HOT WATER INSERT LOCK

TUBE, 9/16"OD X 5/16"ID X 13.00"LG

GROMMET, SILICONE, BLANK

HOT WATER INSERT, NO FAUCET

ORIFICE INSERT, QUICK CONNECT, 3/16" HOLE

VALVE ASSEMBLY, COMPLETE, NG, DELTROL

PLUG INSERT, QUICK CONNECT

BYPASS L-TUBE, SILICONE, 2200 SINGLE SERIES

ASSEMBLY, BB LOCKER, 24VDC

BRACKET, BREW BASKET LOCK COVER

WASHER, #6 SCREW , INTL TOOTH LOCKWASHER

NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED

LEG, FLANGE FOOT, 4" HIGH

CONNECTOR, CLAMP, NON-METALLIC CABLE, 3/4"

SKINTOP, 3/4" NPT, 0.354" - 0.630" DIA CABLE, BLK

LOCKNUT, SKINTOP, 3/4" NPT, BLACK HEX

LABEL EQUIPOTENTIALITY, CE

EMI FILTER, 25A, 250/440VAC, 50/60Hz

NUT, HEX, #6-32 MACHINE SCREW

Go to fetco.com for the latest versions of all information Page 21 User Guide & Operator instructions P213e0 NOVEMBER 2021

CBS-1251 Tank Assembly

CBS-1251 Hot water tank 1104.00165.00 and 1104.00166.00 1 X 4 kW & 1 x 5 kW

REF 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 16 17 18 19 20 21 22

QTY 1 1 1 3 1 1 1 1 2 1 1 2 1 1 1 1 8 8 1 1 1 1 2

TANK ASSY, CBS-1251 Single Heater

Drawing number 1104.000165.00 & 1104.000166.00

Part number

Description

1114.00172.00

WELDMENT, TANK, CBS-2251

1024.00114.00

TANK GASKET - NG HEATER PLATE, TWO ELEMENT

1114.00184.00

WELDMENT TANK HEATER BRACKET, NG-2231, SINGLE

1024.00050.00

GROMMET, SILICONE, 11.4mm ID

1023.00166.00

FITTING, COLD WATER INLET, GROMMET DESIGN

1023.00203.00

FITTING, STRAIGHT, GROMMET, .625"

1003.00140.00

ALUMINUM BRACKET FOR SSR

1052.00033.00

RELAY, SOLID STATE, 50A/480VAC, W/BUILD IN VARISTOR

1081.00042.00

STANDOFF, 1/4" HEX

1107.00010.00

HEATER ASSEMBLY, IMMERSION 4kW/240VAC

1107.00032.00

HEATER ASSEMBLY, IMMERSION, 5kW/240VAC

1024.00053.00

LEVEL AND TEMP PROBE GROMMET

1023.00212.00" FITTING, ELBOW, GROMMET, .500

1112.00019.00

PROBE WELDMENT, WATER LEVEL 2.600" LG

1102.00161.00

PROBE ASSEMBLY, TEMP. AND LLC, 8" LONG

1053.00052.00

THERMOSTAT, SINGLE SHOT, SCREW CONNECTIONS, 240V/25A

1083.00009.00

WASHER, #6 SCREW , INTL TOOTH LOCKWASHER

1084.00010.00

NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED

1044.00004.00

LABEL, DANGER, HIGH VOLTAGE

1024.00051.00

GROMMET, SILICONE, BLANK

1022.00068.00

INSULATION, TANK FRONT, CBS-2151

1022.00069.00

INSULATION, TANK BACK, CBS-2151

1082.00136.00

BRASS SCREW, #8-32 X 1/4", PHILLIPS PAN HEAD

Go to fetco.com for the latest versions of all information Page 22 User Guide & Operator instructions P213e0 NOVEMBER 2021

CBS-1251 Hot water tank 1104.00167.00 and 1104.00168 2 X 2.3 kW & 2 x 3 kW

TANK ASSY, CBS-1251 Two Heater Drawing number 1104.000167.00 & 1104.00168.00

REF QTY Part number

Description

1

1

1114.00172.00

WELDMENT, TANK, CBS-2251

2

1

1024.00114.00

TANK GASKET - NG HEATER PLATE, TWO ELEMENT

3

1

1114.00176.00

WELDMENT TANK HEATER BRACKET, NG-2231

4

3

1024.00050.00

GROMMET, SILICONE, 11.4mm ID

5

1

1023.00166.00

FITTING, COLD WATER INLET, GROMMET DESIGN

6

1

1023.00203.00

FITTING, STRAIGHT, GROMMET, .625"

7

2

1003.00140.00

ALUMINUM BRACKET FOR SSR

8

2

1052.00033.00

RELAY, SOLID STATE, 50A/480VAC, W/BUILD IN VARISTOR

9

4

1081.00042.00

STANDOFF, 1/4" HEX

10 2

1107.00037.00

HEATER ASSEMBLY, IMMERSION 2300W/240VAC

10 2

1107.00005.00

HEATER ASSEMBLY, IMMERSION 3000W/240VAC

11 2

1024.00053.00

LEVEL AND TEMP PROBE GROMMET

12 1

1023.00212.00

FITTING, ELBOW, GROMMET, .500"

13 1

1112.00019.00

PROBE WELDMENT, WATER LEVEL 2.600" LG

14 1

1102.00161.00

PROBE ASSEMBLY, TEMP. AND LLC, 8" LONG

15 2

1053.00052.00

THERMOSTAT, SINGLE SHOT, SCREW CONNECTIONS, 240V/25A

16 10 1083.00009.00

WASHER, #6 SCREW , INTL TOOTH LOCKWASHER

17 10 1084.00010.00

NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED

18 1

1024.00051.00

GROMMET, SILICONE, BLANK

19 1

1044.00004.00

LABEL, DANGER, HIGH VOLTAGE

20 1

1022.00068.00

INSULATION, TANK FRONT, CBS-2151

21 1

1022.00069.00

INSULATION, TANK BACK, CBS-2151

22 4

1082.00136.00

BRASS SCREW, #8-32 X 1/4", PHILLIPS PAN HEAD

Go to fetco.com for the latest versions of all information Page 23 User Guide & Operator instructions P213e0 NOVEMBER 2021

CBS-1252 and CBS1253 Tank Assembly
CBS-1252 Hot water tank 1104.00161.00; 1104.00164.00
2 X 3kW; 2x 5 kW

Ref#
1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 16 17 18 19 20 21 22

Qty
1 3 3 5 1 2 2 2 4 2 2 2 2 1 1 2 16 16 2 1 1 1 4

CBS-1252 Hot Water Tank Part number

Drawing 1104.00161.00 & 1104.00164.00 Description

1114.00164.00 WELDMENT TANK, CBS-2252, LASER

1024.00115.00 TANK GASKET - NG HEATER PLATE, ONE ELEMENT

1114.00181.00 WELDMENT TANK HEATER BRACKET, NG-2232

1024.00050.00 GROMMET, SILICONE, 11.4mm ID

1023.00166.00 FITTING, COLD WATER INLET, GROMMET DESIGN

1023.00203.00 FITTING, STRAIGHT, GROMMET, .625"

1003.00140.00 ALUMINUM BRACKET FOR SSR

1052.00033.00 RELAY, SOLID STATE, 50A/480VAC, W/BUILD IN VARISTOR

1081.00042.00 STANDOFF, 1/4" HEX

1107.00005.00 ASSEMBLY, IMMERSION HEATER, 3000W, 240VAC

1107.00032.00 ASSEMBLY, IMMERSION HEATER, 5000W, 240VAC

1024.00053.00 LEVEL AND TEMP PROBE GROMMET

1023.00212.00 FITTING, ELBOW, GROMMET, .500"

1112.00019.00 PROBE WELDMENT, WATER LEVEL 2.600" LG

1102.00161.00 PROBE ASSEMBLY, TEMP. AND LLC, 8" LONG

1053.00052.00 THERMOSTAT, SINGLE SHOT, SCREW CONNECTIONS, 240V/25A

1083.00009.00 WASHER, #6 SCREW , INTL TOOTH LOCKWASHER

1084.00010.00 NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED

1024.00054.00 GROMMET, SILICONE PLUG

1044.00004.00 LABEL, DANGER, HIGH VOLTAGE

1022.00070.00 INSULATION, TANK FRONT, CBS-2152

1022.00071.00 INSULATION, TANK BACK, CBS-2152

1082.00136.00 BRASS SCREW, #8-32 X 1/4", PHILLIPS PAN HEAD

Go to fetco.com for the latest versions of all information Page 24 User Guide & Operator instructions P213e0 NOVEMBER 2021

CBS-1252 Hot water tank 1104.00160.00; 1104.00162.00; 1104.00163.00
3 X 3kW; 3 X 4 kW & 3 x 5 kW

Ref#
1 2 3 4 5 6 7 8 9 10 11 11 11 12 13 14 15 16 17 18 19 20 21

.

CBS-1252 and CBS-1253 Hot Water Tank Drawing 1104.00160.00; 1104.00162.00; 1104,00163.00

Qty

Part number

Description

1

1114.00164.00 WELDMENT TANK, CBS-2252, LASER

3

1024.00115.00 TANK GASKET - NG HEATER PLATE, ONE ELEMENT

3

1114.00181.00 WELDMENT TANK HEATER BRACKET, NG-2232

2

1024.00053.00 LEVEL AND TEMP PROBE GROMMET

5

1024.00050.00 GROMMET, SILICONE, 11.4mm ID

1

1112.00019.00 PROBE WELDMENT, WATER LEVEL 2.600" LG

1

1102.00161.00 PROBE ASSEMBLY, TEMP. AND LLC, 8" LONG

2

1023.00212.00 FITTING, ELBOW, GROMMET, .500"

2

1023.00203.00 FITTING, STRAIGHT, GROMMET, .625"

1

1023.00166.00 FITTING, COLD WATER INLET, GROMMET DESIGN

1

1107.00005.00 ASSEMBLY, IMMERSION HEATER, 3000W, 240VAC

1

1107.00010.00 ASSEMBLY, IMMERSION HEATER, 4000W, 240VAC

1

1107.00032.00 ASSEMBLY, IMMERSION HEATER, 5000W, 240VAC

3

1053.00052.00 THERMOSTAT, SINGLE SHOT, SCREW CONNECTIONS, 240V/25A,

18

1083.00009.00 WASHER, #6 SCREW , INTL TOOTH LOCKWASHER

18

1084.00010.00 NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED

3

1003.00140.00 ALUMINUM BRACKET FOR SSR

3

1052.00033.00 RELAY, SOLID STATE, 50A/480VAC, W/BUILD IN VARISTOR

6

1081.00042.00 STANDOFF, 1/4" HEX

1

1044.00004.00 LABEL, DANGER, HIGH VOLTAGE

1

1022.00070.00 INSULATION, TANK FRONT, CBS-2152

1

1022.00071.00 INSULATION, TANK BACK, CBS-2152

6

1082.00136.00 BRASS SCREW, #8-32 X 1/4", PHILLIPS PAN HEAD

Go to fetco.com for the latest versions of all information Page 25 User Guide & Operator instructions P213e0 NOVEMBER 2021

Quick connect spray head assembly

CBS-2151; CBS-1252 and CBS-1253 1102.00450.00 QUICK CONNECT SRAYHEAD ASSEMBLY

Ref# Qty

Part number

1

1 1023.00341.00

Description BASE, QUICK CONNECT SPRAY HEAD

2

1 1102.00113.00 SWITCH, REED, ASSEMBLY

3

3 1023.00342.00 QUICK CONNECT CLIP

4

1 1102.00043.00 CASCADE SPRAY DOME, CBS-2050/60'S

5

2 1057.00076.00 VALVE ASSEMBLY, COMPLETE, NG, DELTROL (interchangeable with 1057.00078.00)

5

2 1057.00078.00 VALVE ASSEMBLY, COMPLETE, NG, RPE (interchangeable with 1057.00076.00)

6

2 1024.00107.00 O-RING, 1 3/16" OD X 1 1/16" ID X 1/16" TH, BYPASS SEAL

7

1 1024.00108.00 O-RING, 5 11/16"OD X 5 1/2" ID X 3/32" TH, BREW SEAL

8

1 1023.00369.00 ORIFICE INSERT, QUICK CONNECT, 3/16" HOLE

9

1 1023.00343.00 VENT INSERT, QUICK CONNECT

10

2 1024.00106.00 O-RING, 13/16"OD X 11/16"ID X 1/16" TH, FOR QUICK CONNECT

11

1 1024.00098.00 VENT TUBE, CBS- EXTRACTOR SERIES

12

1 1023.00344.00 PLUG INSERT, QUICK CONNECT

Go to fetco.com for the latest versions of all information Page 26 User Guide & Operator instructions P213e0 NOVEMBER 2021

Wiring Diagrams CBS-1251 PLUS
Wiring diagram 1401.00196.10 SKU: E1251US-1B230-PM110; heaters 2 X 3.0 kW SKU: E1251IN-1B230-PM110; heaters 2 X 3.0 kW
Go to fetco.com for the latest versions of all information Page 27 User Guide & Operator instructions P213e0 NOVEMBER 2021

SSR

CBS-1251 Plus Wiring Diagram 1401.00197.10 SKU E1251IN-1B140-PM110; heaters 1 X 4.0 kW SKU E1251IN-1B150-PM110 ; heaters 1 X 5.0 kW
Go to fetco.com for the latest versions of all information Page 28 User Guide & Operator instructions P213e0 NOVEMBER 2021

SSR

SSR SSR SSR

THREE PHASE POWER L1, L2, & L3
L1 - #1, #31 L2 - #2, #32 L3 - #3, #33

SINGLE PHASE
POWER L1 & L3 L2 - NOT CONNECTED
L1 - #1, #31 L2 - #2, #33 L3 - #3, #32

CBS-1252 V

PlusWiring Diagram 1401.00197.10

SKU E1253US-UB230-PM110 Heaters 2 X 3.0 kW single phase; 3 X 3.0 kW three phase

SKU E1253US-UB250-PM110 Heaters 2 X 5.0 kW single phase; 3 X 5.0 kW three phase

Go to fetco.com for the latest versions of all information Page 29 User Guide & Operator instructions P213e0 NOVEMBER 2021

SSR

SSR

CBS-1252 Plus Wiring Diagram 1401.00199.10 SKU E1252IN-1B230-PM110; heaters 2 X 3.0 kW SKU E1252IN-1B250-PM110, heaters 2 X 5.0 kW
Go to fetco.com for the latest versions of all information Page 30 User Guide & Operator instructions P213e0 NOVEMBER 2021

SSR SSR SSR
CBS-1252 PLUS CE Models SKU E1252IN-3B330-PM110; heaters3 X 3.0 kW 220/380 or 240/415 SKU E1252IN-3B340-PM110; heaters 3 X 4.0 kW 220/380 or 240/415 SKU E1252IN-3B350-PM110; heaters 3 X 5.0 kW 220/380 or 240/415
Go to fetco.com for the latest versions of all information Page 31 User Guide & Operator instructions P213e0 NOVEMBER 2021

End of section notes
N



References

Adobe PDF Library 21.7.131