User Guide for FETCO models including: CBS-1251 Extractor Plus Brewing System, CBS-1251, Extractor Plus Brewing System, Plus Brewing System, Brewing System
2021-11-15 — Rinse dispensers before reuse. Every Day: 1. Wash brew basket with hot sudsy water. 2. Pull CSD from the spray head, it is ...
File Info : application/pdf, 32 Pages, 9.62MB
DocumentDocumentUser's Guide and Operator Instructions CBS-1251; CBS-1252 and CBS-1253 Extractor Plus Brewing System FETCO PLUS® Commercial Beverage Equipment CBS-1251 & CBS-1252 1½ gallon brewer with FETCO 1½ Gallon L4D dispensers (sold separately) CBS-2153 2 gallon Extractor Plus Brewers CONTACT INFORMATION FETCO® FOOD EQUIPMENT TECHNOLOGIES COMPANY 600 ROSE ROAD LAKE ZURICH · IL · 60047-0429 · USA ON THE WEB: fetco.cofee ©2020-2021 FETCO fetco.com PATENTS:https://www.fetco.com/pl,pages,patents,74.html Coffee Brewer: CBS-1250 series PHONE: (800) 338-2699 (US & CANADA) (847) 719-3000 (All Countries) FAX: (847) 719-3001 EMAIL:sales@fetco.com orders@fetco.com (to order parts and equipment) techsupport@fetco.com (all service queries) P213 REV. 000 November 2021 TABLE OF CONTENTS Specifications and Requirements .................................. 2 Electrical Configurations ................................................ 3 Enter Programming ........................................................ 5 Programing Menu Layout............................................... 5 Starting The Brew .......................................................... 6 A Program ...................................................................... 7 B General ....................................................................... 8 C Service Inputs ............................................................. 9 D Service Outputs .......................................................... 9 E Calibration................................................................. 10 F Service Menu ............................................................ 10 F Error Codes .............................................................. 11 G Counters................................................................... 12 H Save & Exit ............................................................... 13 Operator Training ......................................................... 14 Parts Diagram CBS-1251 ............................................ 18 Parts Diagrams CBS-1252 and CBS-1253.................. 20 CBS-1251 Tank Assembly........................................... 22 CBS-1252 and CBS1253 Tank Assembly ................... 24 Quick connect spray head assembly ........................... 26 Wiring Diagrams .......................................................... 27 Specifications and Requirements Water Requirements: CBS-1251; CBS1252 &1253: 20-75 psig, (138-517kPa) 1½gpm/(5.7lpm) Electrical: See electrical configuration chart on page three. CBS-1250 series brewers use a terminal block for electrical connection Water inlet fitting is a 3/8 inch male flare. Tank Temperature, as set by factory: Brewer supplied with inlet valve adaptor for BSP to SAE 200°F (93°C) inside water tank (at sea level) CBS-2151 and CBS-2152 Brew Volume: First Batch 1½ gallons/ 6 liters Second Batch 1 gallon/ 3.8 liters Water supply: (Optimal) 100-150TDS CBS-2153 -2 gallon All beverage equipment must use filtered water. Brew Volume: First Batch 2 gallons/ 7.6 liters Second Batch 1 gallon/ 3.8 liters Total Brew Cycle--Factory Default Settings CBS-2151 1½ gal Factory default setting First batch 1½ gal: 6:30 minutes=[5 minute brew time + 1.30 minute drip delay] + 10% Bypass Second batch-1 gallon: 5:30 minutes=[4 minute brew time + 1.30 minute drip delay] + 0% Bypass CBS-2152 1½ gal Factory default setting: First batch 1½ gal: 6:30 minutes=[5 minute brew time + 1.30 minute drip delay] + 15% Bypass Second batch-1 gallon: 5:30 minutes=[4 minute brew time + 1.30 minute drip delay] + 0% Bypass CBS-2153-2 gallon Factory default setting: First batch 2 gal: 6:30 minutes=[5 minute brew time + 1.30 minute drip delay] + 15% Bypass Second batch-1 gallon: 5:30 minutes=[4 minute brew time + 1.30 minute drip delay] + 0% Bypass Brew-Process parameters are user controllable for: Brew Volume, Brew Time, Prewet Percent, Bypass, Prewet Delay, and Drip Delay Weights and Capacities Model Height CBS-1251 36 7/8 in 1½ gal 940 mm CBS-1252 36 7/8 in 1½ gal 940 mm CBS-1253 39 in 2 gal 99.1 mm CBS-1251 & CBS-1252 Calibrated for 1½ gallons/ 6 liters Width Depth 12 3/4 in 22 1/2 in 320 mm 570 mm 21 7/8 in 22 1/2 in 550 mm 570 mm 21 7/8 in 22 1/2 in 550 mm 570 mm CBS-1253 Calibrated for 2 gallons/ 8 liters Water tank Empty Filled Shipping Shipping capacity Weight Weight Weight Dimensions 6.5 gallon 53 lbs 107 lbs 63 lbs 38" x 18" x 24" 24.4 L 24 kg 48.3kg 28.6 kg 96.5 x 45.7 x 61 cm 11.1 gallon 77 lbs 174 lbs 42.1 L 35.0 kg 78.9 kg 97 lbs 44 kg 38" x 24" x 27" 96.5 x 61 x 68.6 cm 11.1 gallon 82 lbs 180 lbs 97 lbs 40" x 24" x 27" 42.1 L 37.2 kg 81.6 kg 44 kg 102 x 61 x 68.6 cm Filter Paper all models 15" X 5 ½ " standard Or use FETCO # F001 Brewers ship with plastic brew baskets. See page 25 for optional brew baskets Rough-In Drawings 1201.00053.00 (CBS-1251) 1201.00052.00 (CBS-2152) CBS-1251 Front [Numbers in parenthesis are centimeters] CBS-1252 Front CBS-1253 Front Side (all) Back (all) Go to fetco.com for the latest versions of all information Page 2 User Guide & Operator instructions P213e0 NOVEMBER 2021 Electrical Configurations CBS-1251PLUS Single 1½ Gallon-6 Liter Coffee Brewers Domestic and International models Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz Configuration Codes Heater Configuration Voltage Phase Wires KW Amp Draw Brew-Volume/Hour E1251US-1B230-PM110 2 X 3.0 kW 208-240 1 2+G 4.5-6.0 22.2-25.5 15.0 gal/57 liters E1251US-1B230-MM110 2 X 3.0 kW 208-240 1 2+G 4.5-6.0 22.2-25.5 15.0 gal/57 liters E1251IN-1B140-PM110 1 X 4.0 kW 200-240 1 2+G 2.8-4.0 14.4-17.2 10.6 gal/40.3 liters E1251IN-1B150-PM110 1 X 5.0 kW 200-240 1 2+G 3.5-5.0 17.9-21.3 13.3 gal/50.4liters E1251IN-1B230-PM110 2 X 3.0 kW 200-240 1 2+G 4.2-6.0 21.3-25.5 15.0 gal/57 liters CBS-1251PLUS Single 1½ Gallon-6 Liter Coffee Brewers International models Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz Configuration Codes Heater Configuration Voltage Phase Wires KW Amp Draw Brew-Volume/Hour E1251NM-1B230-PM110 E1251KS- 1B230-MM110 E1251C E-1B230-PM110 E1251C E-1B230-PM110 . 2 X 3.0 kW 2 X 3.0 kW 2 X 3.0 kW 2 X 3.0 kW 208-240 220 23 0/ 40 0 230 1 2+G 4.2-6.0 21.3-25.5 15.0 gal/57 liters 1 2+G 5. 2 1 2L /N/P E 5. 6 1 L/N/ PE 5. 6 23.4 13.0 gal/49 liters 12.5 14.9 gal/ 56.4 liters 24.5 14.9 gal/ 56.4 liters CBS-1252PLUS Twin 1½ Gallon-6 Liter Coffee Brewers Field configurable Domestic Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz Configuration Codes E1252US-UB230-PM110 Selectable (1 or 3 phase) Sold as 3 phase Heater Configuration 2 X 3.0 kW 3 X 3.0 kW Voltage 208-240 208-240 Phase Wires 1 2+G 3 3+G KW 4.5-6.0 6.8-9.0 Amp Draw Brew-Volume/Hour 22.2-25.5 15.9 gal/60.4 liters 19.3-22.2 23.9 gal/90.6 liters E1252US-UB250-PM110 2 X 5.0 kW 208-240 1 2+G 7.6-10.0 36.6-42.2 25.3 gal/97 liters Selectable (1 or 3 phase) Sold as 3 phase 3 X 5.0 kW 208-240 3 3+G 11.3-15.0 31.8-36.6 30.0 gal/114 liters . CBS-1252PLUS Twin 1½ Gallon-6 Liter Coffee Brewers Domestic and International models Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz Configuration Codes Heater Configuration Voltage Phase Wires KW Amp Draw Brew-Volume/Hour E1252IN-1B230-PM110 2 X 3.0 kW 200-240 1 2+G 4.2-6.0 21.3-25.5 15.9 gal/60.4 liters E1252IN-1B250-PM110 2 X 5.0 kW 200-240 1 2+G 7.0-10.0 35.2-42.2 26.6gal/100.7liters CBS-1252PLUS Twin 1½ Gallon-6 Liter Coffee Brewers International models Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz Configuration Codes Heater Configuration Voltage Phase Wires KW Amp Draw Brew-Volume/Hour E1252IN-3B330-PM110 3 X 3.0 kW 220/380 240/415 3 4+G 7.6-9.0 12.0-12.9 23.9 gal/90.6 liters E1252IN-3B340-PM110 3 X 4.0 kW 220/380 240/415 3 4+G 10.1-12.0 15.8-17.2 30.0 gal/114 liters E1252IN-3B350-PM110 E1252C E-3B330-PM110 E1252C E-3B350-PM110 3 X 5.0 kW 3 X 3.0 kW 3 X 5.0 kW 220/380 240/415 3 4+G 12.6-15.0 19.6-21.3 30.0 gal/114 liters 23 0/ 40 0 3 3L /N/P E 8. 3 12.5 23 0/ 40 0 3 3L /N/P E 13.8 20.5 22.1gal /83.6 liters 30.0 gal/ 114 lit ers CBS-1252PLUS Twin 1½ Gallon-6 Liter Coffee Brewers Field configurable International Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz Configuration Codes Heater Configuration Voltage Phase Wires KW Amp Draw Brew-Volume/Hour E1252NM-UB250-PM110 2 X 5.0 kW 208-240 1 2+G 7.6-10.0 36.6-42.2 26.6 gal/101 liters Selectable (1 or 3 phase) Sold as 3 phase 3 X 5.0 kW 208-240 3 3+G 11.3-15.0 31.8-36.6 30.0 gal/114 liters . CBS-1253PLUS Twin 2 Gallon-8 Liter Coffee Brewers continued on following page Go to fetco.com for the latest versions of all information Page 3 User Guide & Operator instructions P213e0 NOVEMBER 2021 CBS-1253PLUS Twin 2 Gallon-8 Liter Coffee Brewers Field configurable Domestic Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz Configuration Codes Heater Configuration Voltage Phase Wires KW Amp Draw Brew-Volume/Hour E1253US-UB230-PM110 2 X 3.0 kW 208-240 1 2+G 4.5-6.0 22.2-25.5 15.9 gal/60.4liters Selectable (1 or 3 phase) Sold as 3 phase 3 X 3.0 kW 208-240 3 3+G 6.8-9.0 19.3-22.2 23.9 gal/90.6liters E1253US-UB250-PM110 2 X 5.0 kW 208-240 1 2+G 7.6-10.0 36.6-42.2 25.3 gal/97 liters Selectable (1 or 3 phase) Sold as 3 phase 3 X 5.0 kW 208-240 3 3+G 11.3-15.0 31.8-36.6 30.0 gal/114 liters . CBS-1253PLUS Twin 2 Gallon-8 Liter Coffee Brewers Domestic and International models Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz configuration Codes Heater Configuration Voltage Phase Wires KW Amp Draw Brew-Volume/Hour E1253US-1B230-PM110 2 X 3.0 kW 200-240 1 2+G 4.2-6.0 21.3-25.5 15.9 gal/60.4 liters E1253US-1B250-PM110 2 X 5.0 kW 200-240 1 2+G 7.0-10.0 35.2-42.2 26.6gal/100.7liters E1253IN-1B230-PM110 2 X 3.0 kW 200-240 1 2+G 4.2-6.0 21.3-25.5 15.9 gal/60.4 liters E1253IN-1B250-PM110 2 X 5.0 kW 200-240 1 2+G 7.0-10.0 35.2-42.2 26.6gal/100.7liters CBS-1253PLUS Twin 2 Gallon-8 Liter Coffee Brewers International models Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz Configuration Codes Heater Configuration Voltage Phase Wires KW Amp Draw Brew-Volume/Hour E1253IN-3B330-PM110 3 X 3.0 kW 220/380 240/415 3 4+G 7.6-9.0 12.0-12.9 23.9 gal/90.6 liters E1253IN-3B340-PM110 3 X 4.0 kW 220/380 240/415 3 4+G 10.1-12.0 15.8-17.2 30.0 gal/114 liters E1253IN-3B350-PM110 3 X 5.0 kW 220/380 240/415 3 4+G 12.6-15.0 19.6-21.3 30.0 gal/114 liters E1253NM-1B250-PM110 2 X 5.0 kW 200-240 1 2+G 7.0-10.0 35.2-42.2 26.6gal/100.7liters CBS-1253PLUS Twin 2 Gallon-8 Liter Coffee Brewers Field configurable International Electrical and Output Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz Configuration Codes Heater Configuration Voltage Phase Wires KW Amp Draw Brew-Volume/Hour E1253NM-UB250-PM110 Selectable (1 or 3 phase) Sold as 3 phase 2 X 5.0 kW 3 X 5.0 kW 208-240 208-240 1 2+G 7.6-10.0 36.6-42.2 25.3 gal/97 liters 3 3+G 11.3-15.0 31.8-36.6 30.0 gal/114 liters EXAMPLE: SKU E1253US-UB230-PM110 SKU NUMBER IDENTIFICATION KEY Product Line E E=extractor Level 1 2 12=PLUS Series Family Region ID Phase Voltage Range 53US U US =United States 1 51= IN = single side International 2 52= dual side CE = CE 3 NM = NOM U = 1 or 3 B A = 100-120 B = 200-240 C = 380-415 D = 440-480 53= dual side 2 gallon X=120 or 240 Dual Voltage # Heaters Individual Heater Wattage Brew Basket 2 5 0 P 1 1.5 P=plastic 2 1.7 M=metal 3 2.3 3.0 4.0 5.0 Hot Water Faucet M M=manual A=automatic N=None Bypass Brew Basket Locks 01 1 1=Yes 1=Yes 0=no 0=no Power Cord 0 0=Terminal Block 1= NEMA 5-15P 2=NEMA 5-20P 3=NEMA 6-15P 4=NEMA 6-30P 5= CEE 7/7 Schuko 6=UK1-13P 7= AUSTRALIAN Go to fetco.com for the latest versions of all information Page 4 User Guide & Operator instructions P213e0 NOVEMBER 2021 Enter Programming Screens shown are for twin brewer. Single brewer will not have menu A4-A6. There are seven menu groups-A-G . See the following pages for the batch parameter definitions and all settings for the brewer TO ENTER PROGRAMMING 1-Turn brewer "OFF" from power switch 2-Turn power switch to "ON" ...Screen will initialize and then display digital process notifications 3-After Initialization-Red "STOP" Lamp turns on 4-Quickly press "STOP" button. STOP BUTTON CBS-1252 ver 2.0.210317 STOP STOP Batch Program A STOP STOP When brewer is In PROGRAMMING MODE -the screen will display: On/OFF switch |BATCH PRG| located lower right on back of |A (or B-H) | brewer -Illuminated LED indicates active keypad positions Turn power OFF See the following pages for batch parameter definitions and all settings for the brewer Turn power ON Wait for red LED And quickly press STOP button on front touch pane Note: Only the left side buttons of a two sided brewer are used for programming First screen will display for PROGRAMMING-A Scroll through main menu topics by pressing "STOP" button. Programing Menu Layout A10 to A70 B10-B40 C10-C50 D10-D90 E10-E70 F10-F120 G1-G15 H10-H11 Batch Parameters General Settings Service Inputs Service Outputs Calibration Service Menu Counters Exit and Save | | | | | | | | A11 Brew Volume B1 Tank Temperature C1 LLC Probe D1 Heater SSR E1 Ready Temp. Offset F1 Firmware Ver. G1 Filter Used H1 Save Changes | | | | | | | | A12 Brew Time B2 Brew at Temp C2 Basket Sensor D2 Fill Valve E2 LLC Sensitivity F2 Bootloader Ver. G2 Filter Life H2 EXIT? | | | | | | | A13 Prewet Percent B4 Show Tank Temp C4 Tank Temperature D3 Lt Brew Valve E3 Slow Flow Compensate F3 Select Model G3 Filter Reset | | | | | | | A14 Prewet Delay B5 Units of Temp C5 USB Drive D4 Rt Brew Valve E4 Lt Brew Flow F4 Option Bypass G4 Counter Reset | | | | | | | A15 Bypass Percent B6 Units of Volume C6 Keyboard Test D5 Lt Bypass Valve E5 Rt Brew Flow F5 Option BB Lock G5 Choose Counter | | | | | | A16 Drip Delay B7 Customer Name D6 Rt Bypass Valve E6 Lt Bypass Flow F8 Backup to USB G10 Brewer Volume [T] | | | | | | A20 Batch (2) Enabled B8 Customers Name D7 Lt Basket Lock E7 Rt Bypass Flow F9 Restore from USB G11 Brewer Volume | | | | | A21 Brew Volume B9 Demo Mode D8 Rt BasketLock F10 Restore Defaults G12 LT Brews[T] | | | | | A22 Brew Time B10 Eco Mode D12 LCD Brightness % F11 Error Log G13 LT Brews | | | | | A23 Prewet Percent B11 Eco Idle Time D13 LED Brightness % F12 Erase Error Log G14 Rt Brews [T] | | | | A24 Prewet Delay B12 Eco Idle Temp F13 Service Phone# G15 Rt Brews | | | A25 Bypass Percent B13 Water Filter F14 Override Lt BBS See page 12 | | A26 Drip Delay F15 Override Rt BBS | | A30 Batch (3) Enabled F16 Override Lt BBL | | A90 Copy Batch F17 Override Rt BBL | A91 Copy Batch: From | A92 PASTE: To Top and middle batches are permanent SEE BOX on the following page for all "A" menus Go to fetco.com for the latest versions of all information Page 5 User Guide & Operator instructions P213e0 NOVEMBER 2021 FETCO Ready to Brew STOP STOP Starting The Brew 1. Turn the power switch "ON". (Twin Shown) 2. Prepare a brew basket with the correct size filter and appropriate amount of coffee. 3. Slide the brew basket completely into the rails. 4. Place a clean, empty, and preheated dispenser under the brew basket. 5. Select a batch & hold the corresponding BREW button in for 1 second to start 6. -STOP button will illuminate, -Countdown time will display, -Selected BREW button will flash to indicate brew is in progress. -All other BREW buttons for that brew head will extinguish. Ready STOP Brewing 5:30 STOP 7. When the brew cycle is finished, STOP button will extinguish and the BREW button will continue to flash for the amount of time programmed into the DRIP DELAY setting. This indicates that coffee may still be dripping from the brew basket For safety- do not remove brew basket until drip-out is complete. Twin Brewer ready to brew. Example shown: Pressing top right brew position Brewing-see #6 above RECIPE Location map Viewing and changing settings for the brew recipes is from the "A" screens with the controls in PROGRAMMING. Single Side Models CBS-1231 Plus STOP DISPLAY STOP Dual Side Models CBS-1232 Plus STOP STOP DISPLAY STOP The uppermost button positions are permanent and will not display programming step A_0. The table above shows in position A20 that a button position can be made active or inactive. Position A1 does not display this step BATCH A1 (permanent) BATCH A2 (enabled by factory) BATCH A3 (disabled by factory) BATCH A4 (permanent) BATCH A5 (enabled by factory) BATCH A6 (disabled by factory) The "A" menu is the most accessed menu. It is for programming the batch volumes, brewing parameters, enabling or disabling brew buttons. The "A" menu moves through the six positions(CBS-1252-) or three positions(CBS-1251+) by entering the menu and pressing the left stop button. (only the left side is active for programming the CBS-1252+) The A menus [A1-3 or A1-6] correspond to batch buttons [3 or 6] on the touch panel Access the A menus to PROGRAM & make changes to individual menu recipes. Menu settings can be copied Menu positions A1 and A4 [top position] are permanent. Menus A2, A3, A5, A6 can be removed by operator if desired Batch Program A1 Brew Volume A1.10 3.80L +/- Batch Enabled A2.00 YES - Batch Enabled A6.00 NO+ (Dual model shown) Batches A1 to A6 STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP A1 A4 A2 A5 From A PRG screen Press button 1 to go into to the A menu access screens. Continue pressing button #1 to enter progamming for A1 From A11 screen Press STOP to scroll to A20. (A1&A4 are permanent) From A20 screen Press STOP to scroll through the remaining (3 or 6) "A" menus. Make any changes as required A3 A6 From A60 screen Scroll out to remaining A10-to A70 programming keys. See SAVE & EXIT in previous table For single and twin Position of batch buttons for CBS-1252+ The CBS-1251+ single position brewer has one row of buttons Go to fetco.com for the latest versions of all information Page 6 User Guide & Operator instructions P213e0 NOVEMBER 2021 A Program Menu Features: Batch Parameters The settings below are shown for the top batch on a single brewer top left button on a twin brewer. See how to access all A menus on the previous page. Below are the brew settings for default A1 & A2 batches POSITION Program Items Factory set Default Programming Range Increments Notes A1.10 Batch Volume 1.5 gal 6.8 liters 0.51 to 2.00 gal 1.93 to 7.57L 0.01G 0.05L A1.10 Batch Volume CBS-2153 only 2 gallons 9.1 liters 0.51 to 2.66 gal 1.93 to 10.1L 0.01G 0.05L A1.20 Brew Time 5:00 minutes 2:00 12:00 0.30 Default total brew time is 6:30 minutes A1.30 A1.40 A1.50 A1.60 This is a Safety Feature Prewet Perc. 0% Prewet Delay (Pause after prewet completes) Bypass Percent 0% [1:00 Min] CBS-1251:10% CBS-1252/3:15% 0.00 25.0% [0:10 5:00] 0% 40% Drip Delay 1:30 mm:ss 0:30 6:00 Min. 1% 1:00 min 1% Percentage of total brew volume The time between prewetting and start of brew cycle. This feature appears ONLY if Prewet >0:00 Diverts brewing water from brew process Time that brew basket remains locked during final drip-out Drip delay remains "ON" for 1:30 minutes if STOP is pressed during brew A2.00 BATCH ENABLED YES (Active) Middle and Bottom batches A2,3,5,6 Batch on or off Batches may be individually enabled, rewritten or deactivated A2.10 Batch Volume 1.5 gal 6.8 liters 0.51 to 2.00 gal 1.93 to 7.57L 0.01G 0.05L A2.10 Batch Volume CBS-2153 only 2 gallons 9.1 liters 0.51 to 2.66 gal 1.93 to 10.1L 0.01G 0.05L A2.20 Brew Time 4.00 minutes 2:00 12:00 0.30 Default total brew time is 5:30 minutes A2.30 Prewet Perc. 0% 0.00 25.0% 1% Percentage of total brew volume A2.40 Prewet Delay (Brew pause after prewet completes) 0% [1:00 Min] [0:10 5:00] 1:00 min The time between prewetting and start of brew cycle. This feature appears ONLY if Prewet >0:00 A2.50 Bypass Percent CBS-1251:0% CBS-1252&3: 0% 0% 40% 1% Diverts brewing water from brew process A2.60 Time that brew basket remains locked during final drip-out This is a Drip Delay 1:30 mm:ss 0:30 6:00 Min. Drip delay remains "ON" for Safety 1:30 minutes if STOP is Feature pressed during brew A30 Batch Enabled A30 YES NO + NO-inactive (defaults to recipe A20 if activated) Middle and Bottom batches A2,A3 Batch on or off Batches may be individually enabled, rewritten or deactivated A90 Batch Copy From Batch A90 A90 1 (1-6) Copy A91 Copy To Batch? A91 A91.1 (1-6) PULSE BREW note. FETCO CBS-1200V+ brewers are factory programmed to pulse 2 cycles per minute brew time Changing the brew time only will increase the pulses but will not change the volume of brew water delivered . Go to fetco.com for the latest versions of all information Page 7 User Guide & Operator instructions P213e0 NOVEMBER 2021 B General POSITION Program Items B1 Tank Temp. B2 Brew at Temp. B4 Show Tank Temperature B5 Units of Measure TEMPERATURE B6 Units of Measure VOLUME B7 Customer Name Brewer Operation Control Settings, Adjust Brew Flow Rate Factory set Default Programming Range Increments Notes 200°F-or-93° C NOTE: Equipment is Fahrenheit by default "YES" YES 77° to 97°C 170°F to 207°F ON/OFF YES/NO F°-Fahrenheit Fahrenheit/Celsius G-Gallons Gallons/Liters/Ounces 0.5°C 1.0°F YES/NO C/F Gal/L/Oz Chart to correct for high altitude below SEE NOTE BELOW To display HW tank temperature on screen NOTE: Overwrites user settings (see page 9) NOTE: Overwrites user settings (see page 9) Off NO or YES For name on screen B8 B9 B10 B11 B12 B13 Customer Name Demo Mode Eco Mode Eco Idle Time Eco Idle Temp Water Filter (only if above is "ON) DEMO ON/OFF On 1Hr 170°F OFF Scroll with batch keys ON/OFF 1-6 hours 158-176°F ON/OFF A-Z;a-z;0-9 YES/NO 1 hour 1 degree YES/NO 16 characters total Demonstrates the controls for training. Disables all components in demo mode If Selected: Lowers hot water tank temperature after preset time of inactivity Time of inactivity to go into ECO Mode Temperature that hot water tank is lowered to Water filter life is accessed in G-Counters. This is user set and will display indicator to change water filter BREW AT TEMPERATURE DEFINITIONS DEFAULT: BREW AT TEMP: "ON" (FACTORY DEFAULT FOR BREWER) "BREW at TEMP: Hot water tank not vv vv vv at brew temp -Batch will not start if tank temperature setpoint. is below set point. -Display will show "HEATING" and hot water tank temperature Tank temp HEATING 160°F The "BREW START" entry buttons will not STOP is not lit STOP STOP illuminate until the hot water tank reaches the selected temperature. BREW START buttons not lit. Controls allow both sides of dual brewer to and are disabled. operate if one side has an ongoing brew started and the second side brew is selected. When hot water Notifications shown on screen: tank temperature TEXT: HEATINGTank above 87°C/189°F-will is at setpoint. allow brew at low temperature. Buttons will Coffee flavor may be affected illuminate and TEXT: L. HEATTank above 77°C/170°F- "READY" will be will allow brew at low temperature. displayed Coffee flavor will be noticeably affected USER SELECTABLE OPTION: BREW AT TEMP: OFF (Not recommended) Unit will operate at lower temperature Allows brewing at any temperature above 77°C/170°F Below 70°C/170°F The brewer will display "HEATING" Chart to correct for altitude for boiling point in tank water temperature. [ft] [m] Suggested Boiling Setting[°F] point[°F] Suggested Boiling Setting[°C] point [°C] 0 0 205 212.0 96 100.0 500 152 205 211.0 96 99.5 1000 305 200 210.1 93 98.9 2000 610 200 208.1 93 97.8 2500 762 200 207.2 93 97.3 3000 914 200 206.2 93 96.8 3500 1067 197 205.3 92 96.3 4000 1219 195 204.3 91 95.7 4500 1372 194 203.4 90 95.2 5000 1524 194 202.4 90 94.7 5500 1676 193 201.5 89 94.2 6000 1829 192 200.6 89 93.6 6500 1981 191 199.6 88 93.1 7000 2134 190 198.7 87 92.6 7500 2286 188 197.8 86 92.1 8000 2438 187 196.9 86 91.6 8500 2591 185 196.0 85 91.1 Go to fetco.com for the latest versions of all information Page 8 User Guide & Operator instructions P213e0 NOVEMBER 2021 C Service Inputs POSITION Program Items C1 LLC Probe continuity C2 Brew Basket Sensor C4 Tank Temperature C5 USB Drive C6 Keyboard Test Brewer Sensors and Keypad Factory set Default Programming Range Increments Direct read Tank water 850- LOW resistance in TDS 1600-HIGH L-YES R-YES YES or NO Direct read NO Calibrate Hot water tank temperature (not in use) Checks buttons under membrane cover YES/NO Notes Nominal values Actual values Follow directions on the touch screen D Service Outputs Test Valves and Heaters; Set screen brightness POSITION Program Items Factory set Default Programming Range Increments Notes D1 Heater SSR Test Press button 2 to test (button 1 stops test) Activates heater Default is 10 sec.. Toggle +/OFF or ON Energizes Heater(s) WARNING! Service use only. D2 Fill Valve Test Press button 2 to test (button 1 stops test) Activates valve Default is 10 sec. Toggle +/OFF or ON Press To Test D3 LT (left) Brew Valve Test (Press to test) Activates valve Default is 10 sec. Toggle +/OFF or ON Runs valve to verify flow. NOTE: Have container under brew basket. D4 RT (right) Brew Valve Test (Press to test) Activates valve Default is 10 sec. Toggle +/OFF or ON Runs valve to verify flow. NOTE: Have container under brew basket. D5 LT (left) Bypass Valve Test (Press to test) Activates valve Default is 10 sec. Toggle +/OFF or ON Runs valve to verify flow. NOTE: Have container under brew basket. D6 RT (right) Brew Valve Test (Press to test) Activates valve Default is 10 sec. Toggle +/OFF or ON Runs valve to verify flow. NOTE: Have container under brew basket. LT (left) D7 Brew Basket Lock (Press to test) Test Activates Brew Basket Lock Toggle +/OFF or ON Press To Test RT (right) D8 Brew Basket Lock (Press to test) Test Activates Brew Basket Lock Toggle +/OFF or ON Press To Test Single series displays right side only Left Valve display is only for twin side brewer. Adjust LCD screen D12 LCD Brightness Brightness=90% 20-100% 5% brightness only-Not for LEDs under buttons Adjust LED button D13 LED Brightness Brightness=60% 20-100% 5% brightness only-Not for the screen display LCD Go to fetco.com for the latest versions of all information Page 9 User Guide & Operator instructions P213e0 NOVEMBER 2021 E Calibration Brewer Sensors and Keypad POSITION Program Items Factory set Default Programming Range Increments Notes E1 Ready Temp. Offset -3°F -2°C -2° to -9°F -1° to -5° C 1°F Compensates output to measured 1°C temperature E2 LLC Sensitivity NORMAL ("NORMAL" for most water) HIGH (Biased for reverse osmosis water or very pure water) NORMAL Liquid level control sensitivity. High,1300 is for reverse HIGH osmosis water or very pure water. E3 Slow flow rate from supply ON OFF/ON Toggle +/- Trims fill system for low supply or YES or NO Flojet use E4 LT Brew Valve flow rate: 0.95G 0.80-1.09G 1.30-1.90Liter 0.01G 0.05L Adjusts flow rate E5 RT Brew Valve flow rate: 0.95G 0.80-1.09G 1.30-1.90Liter 0.01G 0.05L Adjusts flow rate E6 LT Bypass Valve flow rate: 0.38G 0.31-0.44G 0.80-1.09Liter 0.01G 0.05L Adjusts flow rate E7 RT Bypass Valve flow rate: 0.38G 0.31-0.44G 0.80-1.09Liter 0.01G 0.05L Adjusts flow rate Use this formula to compensate for minor discrepancies in actual volume versus programmed volume. See "PROGRAM" E4 & E5 For valve settings and calibration. Factory set brew valve flow rates are in liter/min Current setting is the flow from E4,E5, E6, E7 Default Brew Valve Flow Rate--CBS-1250 Brewers See table above for factory set default flow rates CBS-1250 Gallons/minute Range ACTUAL VOLUME PROGRAMMED VOLUME X CURRENT SETTING = NEW SETTING Left Brew Valve FR Right Brew Valve FR 0.95 0.80G to 1.09G 0.95 0.80G to 1.09G Use this formula to determine the correct setting Set FR lower to increase volume; set higher to decrease volume. F Service Menu POSITION Program Items F1 Display Firmware F2 Display Bootloader F3 Select Model F4 Option Bypass F5 Option BB Lock F8 Backup to USB F9 Restore From USB F10 Restore Defaults F11 Error Log F12 Erase Error Log F13 Service Phone # F14 Override Lt BBS F15 Override Rt BBS F16 Override Lt BBL F17 Override Rt BBL Software & Code View and Settings Factory set Default Programming Range Increments 2.2.210720 Displays current version 2.0.210317 CBS1251;1252;1253 Will need reboot Yes Displays current version Scroll to brewer model Save & Exit CBS-1221 CBS-1251, CBS-1252 CBS-1241, CBS-1242 CBS-1251, CBS-1252 CBS-1261, CBS-1262 MBS-1221, MBS-1251 TBS-1221, MBS-1222 NO or YES Yes NO or YES NO Follow prompts Saves settings Applies settings from USB NO NO/YES Lists up to six codes, in order 1: ; 2: ;3:;4: ;5: ;6: 1=Newest/6=Oldest LAST six errors only Newest=first Oldest=last NO + Toggle +/YES or NO Enter as needed NO NO/YES Toggle +/YES or NO NO NO/YES Toggle +/YES or NO NO NO/YES Toggle +/YES or NO NO NO/YES Toggle +/YES or NO Notes [6/2020] [6/2020] NOTE: Overwrites all user settings (See below) Insert blank USB Insert USB Will need reboot Reset to factory See Error Codes Chart for references FACTORY USE ONLY. DO NOT RESET Set phone contact Disables brew basket sensor Disables brew basket sensor Disables brew basket lock Disables brew basket lock Go to fetco.com for the latest versions of all information Page 10 User Guide & Operator instructions P213e0 NOVEMBER 2021 F Error Codes DO NOT CLEAR ERROR CODES UNTIL ERROR IS IDENTIFIED AND CORRECTED Contact factory or specialized personnel for error codes Code Description Possible Cause Corrective Action 001 Software error-error on start up or corrupted software 002 Internal flash corrupted internal data memory malfunction Improper start-up or shutdown Error found in cyclic redundancy check CRC Restart , if still fault: reload software Restart , if still fault: reload software If not corrected :replace board 050 Short-circuit in temperature probe Probe failure. Replace probe. 051 Open temperature probe. Initial Fill Error. 100 Initial fill time took longer than expected after powering up. Bad probe connection, or probe failure. Water supply flow rate is too low. Check all connections. Replace probe if necessary. Watch for short potting during brew cycle. Investigate cause of low flow rate. (Clogged water filter...) 101 Error on refill-. Tank did not refill within expected time. Water flow too slow from main. Water supply flow rate is too low. (External to brewer.) Watch for short potting during brew cycle. Investigate cause of low flow rate. (Clogged water filter...) 200 Heating flatline-Tank is boiling Heater is on, temperature is High elevation correction. Bad heaters or not rising/dropping temperature probe or position 201 Heater open, high limit thermostat, or Solid State Relay (SSR) fault 202 Heater Shorted or Stuck SSR 255 Keyboard [HID] error NO BSKT Insert Brew Basket Check that ohms range of heater are Failure of heating element, SSR, high limit or low voltage between 10-80; replace if not. Check for continuity, and if open replace high limit devices. Check if permanently closed and replace SSRs,if necessary. Check that ohms range of heater are Heater is off and equipment is heating. SSR is stuck "ON" between 10-80; replace if not. Check if permanently closed SSR may be stuck in ON mode-replace SSR. Test output on solid state relay Usually from longer than 10 se contact. Or faulty reassembly after service Restart , if still fault: reload software. If mechanical: replace module Brew basket must be in place This is a SAFETY FEATURE Insert brew basket into brewer rails to enable brewer Go to fetco.com for the latest versions of all information Page 11 User Guide & Operator instructions P213e0 NOVEMBER 2021 G Counters Brewer Usage, Water Filter Usage, and Statistics ROLE: [LT]=Permanent total for lifetime of machine; [R]=operator resettable; [User]=Input needed from operator Position Counter Program items Role Information Increments Notes G1-G4 are for water filter maintenance. All beverage equipment must use filtered water and filter cartridges must be monitored for quality G4 A, S, B Counter Reset [User] NO Toggle +/- ,Y or N Resets all resettable counters to zero Basic=B Stored brewer component activity.. G5 A, S, B Choose Counter Factory set to BASIC Advanced=A See column 2, Counters, to identify where Statistical=S counters are located. G10-G15 Number of brews and volumes handled. Available in BASIC counter only (G5) G10 G11 B Brewer Volume B Brewer Volume [LT] [R] Dispensed volume Gallons/Liters Total of brews and hot water dispensed G12 B Lt Brews G13 B Lt Brews [LT] Left side brew total [R] CBS-1252 Count Total brews-Left side (CBS-1252 only) G14 B Rt Brews G15 B Rt Brews [LT] [R] Right side brew total CBS-1251&CBS-1252 Count Total brews-Right side CBS-1251&CBS-1252 G20-G55 component use cycles and volumes handled. Available in ADVANCED counter only (G5) G20 A Fill Cycles G21 A Fill Cycles [LT] Hot water tank refill [R] cycles Count Cycles of hot water tank refill G22 A Fill Volume G23 A Fill Volume [LT] Total volume of water [R] for all brews Gallons/Liters Quantity of water for brews G24 G25 A Lt Brew Cycles A Lt Brew Cycles [LT] Left brew valve [R] operation on/off Count Totalized cycles of valve operation (CBS-1252 only) G26 A Lt Brew Volume [LT] Left brew valve flow through volume Gallons/Liters G27 A Lt Brew Volume [R] G28 G29 A Rt Brew Cycles A Rt Brew Cycles [LT] Right brew valve [R] operation on/off Count G30 G31 A Rt Brew Volume A Rt Brew Volume [LT] Right brew valve [R] flow through volume Gallons/Liters G32 G33 A Lt Bypass Cycles [LT] Left bypass valve A Lt Bypass Cycles [R] operation on/off Count G34 G35 A A Lt Bypass Volume Lt Bypass Volume [LT] Left bypass valve [R] flow through volume Gallons/Liters G36 G37 A A Rt Bypass Cycles Rt Bypass Cycles [LT] [R] Count Count G38 G39 A A Rt Bypass Volume Rt Bypass Volume [LT] [R] Right bypass valve flow through volume Gallons/Liters G48 G49 A Lt BBL Cycles A Lt BBL Cycles [LT] Left brew basket lock [R] flow through volume Count G50 G51 A Rt BBL Cycles A Rt BBL Cycles [LT] [R] Right brew basket lock operation on/off Count G52 G53 A Heater Cycles A Heater Cycles [LT] ON/OFF switching for [R] heating elements Count G54 G55 A Heater On Time A Heater On Time [LT] Total ON time for [R] heating element Hour G80-G91 See illustration below for batch button positions Available in STATISTICAL counter only (G5) G80 G81 S Batch 10 Cycles S Batch 10 Cycles [LT] Menu button selection [R] and activation count Count G82 G83 S Batch 20 Cycles S Batch 20 Cycles [LT] [R] Menu button selection and activation count Count G84 G85 S Batch 30 Cycles S Batch 30 Cycles [LT] [R] Menu button selection and activation count Count G86 G87 S Batch 40 Cycles S Batch 40 Cycles [LT] [R] Menu button selection and activation count Count G88 G89 S Batch 50 Cycles S Batch 50 Cycles [LT] [R] Menu button selection and activation count Count G90 G91 S Batch 60 Cycles S Batch 60 Cycles [LT] [R] Menu button selection and activation count Count Totalized volume through left valve (CBS-1252 only) Totalized cycles of valve operation CBS-1251&CBS-1252 Totalized volume through right valve CBS-1251&CBS-1252 Totalized cycles of valve operation (CBS-1252 only) Totalized volume through left valve (CBS-1252 only) Totalized cycles of valve operation CBS-1251&CBS-1252 Totalized volume through right valve CBS-1251&CBS-1252 Totalized cycles of brew basket lock operation (CBS-1252 only) Totalized cycles of brew basket lock operation CBS-1251&CBS-1252 Totalized cycles of heater switching Totalized heater ON time in hours Total brews-left side top button (CBS-1252 only) Total brews-left side middle button (CBS-1252 only) Total brews-left side bottom button (CBS-1252 only) Total brews-right side top button CBS-1251&CBS-1252 Total brews-right side middle button CBS-1251&CBS-1252 Total brews-right side bottom button CBS-1251&CBS-1252 Go to fetco.com for the latest versions of all information Page 12 User Guide & Operator instructions P213e0 NOVEMBER 2021 H Save & Exit Saving changes and exiting PROGRAMMING The brewer will save changes only from the "H" menu. DO NOT reboot brewer or toggle ON/OFF-exit as below. TO EXIT PROGRAMMING & HOW TO SAVE CONTROL SETTING CHANGES HOW TO SAVE CHANGES AND EXIT-The brewer is in PROGRAMMING mode. Programming A-H EXIT A-H+ H EXIT SAVE EXIT NO + H YES - H1 NO + H YES - STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 From any screenPress STOP button until the EXIT ("H") screen appears From the "H" screen Press button 2 to toggle to the EXITYES screen From EXIT screen Press button 1 to toggle to the SAVE screen From SAVE screen Press button 2, to toggle to the SAVE- YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT NOTE: User Settings will be erased and overwritten to factory default settings by the following five programming changes 1) When setting or changing units of display for the tank temperature (F Fahrenheit or C Celsius). (SETTING B4) 2) When setting or changing units of display for the volume (L liters, G gallons). 3) When setting brewer model The software sets equipment to brewer defaults (SETTING B5) (SETTING F3) 4) When loading from USB (Reprograms settings) 5) When restoring defaults (Reloads to defaults ) (SETTING F9) (SETTING E10) Go to fetco.com for the latest versions of all information Page 13 User Guide & Operator instructions P213e0 NOVEMBER 2021 Operator Training Review the operating procedures with whoever will be using the brewer. Pay particular attention to the following areas: 1. Always pre-heat the dispensers before the first use of each day by filling them halfway with hot water and letting them stand for at least 5 minutes. 2. Do not remove the brew basket from a coffee brewer until it has stopped dripping. 3. Make sure the dispenser is empty before brewing into it. 4. Show how to attach covers, close, and or secure the dispensers for transporting. 5. Show the location and operation of the water shut off valve as well as the circuit breaker for the brewer. 6. Steam from the tank will form condensation in the vent tubes. This condensation will drip into and then out of the brew baskets. Up to 1/4 cup/118cc discharging overnight is possible. Place an appropriate container under each brew basket when not in use. 7. We recommend leaving the power to the brewer on overnight. The water tank is well insulated and very little electricity is used to keep the tank hot. Leaving the brewer in the "ON" position will also avoid delays at the beginning of shifts for the brewer to reach operating temperature. Cleaning & Maintenance After Each Brew: 1. Dispose of grounds and rinse brew basket. 2. Never strike a brew basket or hit it against a hard surface. This will damage the brew cone, and may damage the brew basket support rails 3. Rinse dispensers before reuse. Every Day: 1. Wash brew basket with hot sudsy water. 2. Pull CSD from the spray head, it is magnetically attached. Use gloves or a heavy towel. Wash off any film and reattach. Use vinegar if limescale filming is present. 3. Clean dispensers with hot suds water and a brush, rinse and air dry. 4. Use only a soft cloth and hot suds on the outside to avoid scratches. Never use abrasives that will scratch surface. Weekly 1. Use a commercial coffee dispenser cleaner such as URNEXTM, TABZTM, DIP-ITTM or Squeak 'n CleanTM. 2. Carefully Follow the instructions supplied with the cleaning product 3. Never use spray cleaners, solvent, solvent based cleaner or petroleum based polish anywhere on dispensers Warning 1. Turn off power before any cleaning procedure, including wiping the exterior for appearance reasons. 2. Dry the exterior, especially the face panel, before turning on power. 3. Do not apply any type of spray cleaner on the face panel of this equipment. 4. Never use solvent or solvent-based cleaner or petroleum based polish anywhere on this equipment. 5. Dry the face of the touch pad before turning on power 6. Do not electrically energize this equipment or attempt operation without all covers in place and all screws fastened. 7. Unplug machine before disassembly or servicing. Safety Notes 1. Professional installation is required. This appliance is manufactured only for commercial use 2. Operational requirements and maintenance for commercial cooking appliances differ from household appliances. 3. Operators must be trained for this equipment and must understand the use, maintenance and hazards. 4. Access to the service area is restricted to persons having safety/hygiene knowledge and practical experience of the coffee brewer. This appliance must be installed in locations where it can be overseen by adult trained personnel. 5. Do not attempt to move hot beverage equipment once it is filled. Drain equipment before moving. 6. FETCO commercial coffee brewers prepare large amounts of coffee or tea in a single batch using very hot water 7. Commercial coffee brewers provide very hot water from the spray head, brew basket and faucet when it is pulled. 8. Coffee brewers may continue to dispense very hot water from the mechanically operated faucet after the electronic touchpad is completely disabled by turning off the power switch on the lower back of the unit or unplugging the unit. 9. For safety, the brewer control locks the brew basket for 6.0 minutes after starting the brew. 10. Never attempt to defeat the factory set (default) time that the brew basket is locked for safety from start of brew. Keep these instructions for training and future reference. Go to fetco.com for the latest versions of all information Page 14 User Guide & Operator instructions P213e0 NOVEMBER 2021 (For Qualified Service Technicians Only) General: 1. If not installed correctly by qualified personnel, the brewer will not operate properly, and damage may result. 2. Utilize only qualified beverage equipment service technicians for service and installation. 3. Always have an empty dispenser under spray head of all coffee brewing equipment-including when at idle 4. Damages resulting from improper installation are not covered by the warranty and will void the warranty. Below are the key points to consider before installation: Electrical: 1. All CBS_Series brewers require an electrical ground wire. Installation without grounding is dangerous. 2. Note Equipotentiality Terminal, if present, (To identify the terminals which, when connected together, bring the various parts of equipment or of a system to the same potential, not necessarily being the earth (ground) potential, e.g. for local bonding.) 3. Verify voltages, polarity, circuits, and circuit breaker access before attaching equipment. 4. Brewers in this series wire differently in regard to a neutral wire. Review the wire diagrams. 5. The electrical diagram is located in the User's Guide and online at www.fetco.com. 6. Make sure of the tight grounding of the equipment and use the external ground bolt. 7. The installation must comply with applicable federal, state, and local codes having jurisdiction at your location. Check with your local inspectors to determine what codes will apply. See wiring diagrams on pages 29-31 for connections Plumbing: 1. North America: All installations must comply with applicable federal, state, or local plumbing codes. 2. All Others: The water and waste piping and connections shall comply with the International Plumbing Code, International Code Council (ICC), or to the Uniform Plumbing Code (IAPMO). 3. Install a backflow prevention device. Most municipalities require a recognized backflow preventer Usable on all hot beverage and cold beverage equipment is a WATTS® SD-2 or SD-3. WATTS spring loaded double check valve models are accepted by most zoning authorities. The check valve should be as close to the water supply inlet of the beverage equipment as possible 4. All beverage equipment must use a water filter. A finishing carbon filter is preferred 5. Install the filter unit after a water shutoff valve and in a position to facilitate filter replacement. 6. The water line and newly installed filter cartridge must be flushed thoroughly prior to connecting it to the brewer to prevent debris from contaminating the machine 7. Verify that the water line will provide a flow rate of at least 1½ gpm/(5.7lpm) per minute and the water pressure is between 20-75 psig (138-517kPa) before making any connections 8. Only use the supplied factory fitting to attach water supply line to brewer (shipped in brew basket) 9. The suppled fitting is a 3/8" flare/compression fitting for 1/4" supply line. Other adaptors may be substituted. 10. Hand tighten the factory fitting when connecting the stub on the brewer. This will reduce stress on the internal connections and reduce the possibility of leaks developing after the install has been completed Tank Drain The water tank must be drained before maintenance procedures, and when the unit is to be relocated or shipped. Drain is for service use only and must not be permanently connected. NOTE: Never plumb a water line to the drain. 1.Disconnect power and water to unit. DANGER: Ensure that all utility connections to the brewer are broken. 2.Move the unit near a sink or obtain a container large enough to hold four gallons of water. Note: The CBS-1251 hot water tank when full holds 6.5 gallons; the CBS-1252 11.1 gallons. 3.Remove the front panel and tank cover and allow the tank to cool to a safe temperature 4.The tank drain line and clamp are located inside-under the hot water tank. Pinch the drain line clamp to close 5.Locate the fill valve against the back wall, using pliers, loosen the hose clamp and move it back over the tube. Note Do not loosen the hose clamp to the bottom of the hot water tank 6.Crimp the tube an inch or two away from the drain plug to prevent water from flowing and pull it off the valve. 7.Pull the tube end out of the brewer and position over sink or bucket. 8.Release the crimped tube and hose clamp and allow the water to flow into the sink or container. 9.Reverse steps 4-8 when service is complete. Ensure pinch clamp is open and hose clamps are in place. Brewer Hot Water Tank Capacity OPEN Leave open for use CBS-1251 Single 6.5 gal 24.4 liter PINCH SHUT CBS-1252 Twin 11.1 gal 42.1 liter To drain tank & service brewer AI! Go to fetco.com for the latest versions of all information Page 15 User Guide & Operator instructions P213e0 NOVEMBER 2021 Installation safety and hygiene directions-For International and CE equipment 1. Access to the service area is restricted to persons having safety/hygiene knowledge and practical experience of the coffee brewer. This appliance must be installed in locations where it can be overseen by trained personnel. 2. For proper operation, this appliance must be installed indoors where the temperature is between 10°C/50°F to 35°C/95°F. Drain and remove all liquid from equipment and lines if exposed to freezing temperatures. 3. All commercial cooking equipment, including this unit, is not intended for use by children or persons with reduced physical, sensory, or mental capabilities. Ensure proper supervision of children and keep them away from the unit. 4. Children should be supervised to ensure that they do not play around hot beverage equipment. 5. This unit must be installed and serviced by qualified personnel only. 6. Installation must conform to all local electrical and plumbing codes. Installation by unqualified personnel will void the unit warranty and may lead to electric shock or burn, as well as damage to unit and/or its surroundings. 7. If the power cord requires repair or replacement-it must be performed by the manufacturer or authorized service personnel with the specified cord only from the manufacturer in order to avoid a hazard. 8. Review the dimensions for the unit and verify that it will fit properly in the space intended for it. Verify that the counter or table will support the total weight of the brewer and dispensers when filled (See: Technical Data). 9. Place the brewer on the counter or stand. When the brewer is in position, level it front to back as well as side-toside by adjusting the legs. 10. Brewers will need a sturdy supported surface for operation. Do not move brewers when filled. 11. Do not tilt appliance more than 10° to insure safe operation. 12. Unit is for protected indoor use only. Do not steam clean or use excessive water on unit. 13. This unit is not "jet-proof" construction. Do not pressure wash or use jet spray to clean this unit. 14. The unit is not waterproof-do not submerge or saturate with water. Equipment exposed to flood and contaminated must not be used due to electrical and food safety. Do not operate if unit has been submerged or saturated with water. Labels and warnings for hot beverage equipment For BACK PANEL of equipment (1046.00035.00) Go to fetco.com for the latest versions of all information Page 16 User Guide & Operator instructions P213e0 NOVEMBER 2021 Complete Brew Basket Brew basket handle plug for polymeric brew baskets is available in optional colors. Part Number B015280BN2BK 0.280" diameter hole Part Number Plug Insert color 1023.00195.00 BROWN PLUG, BB HANDLE 1023.00194.00 BLACK PLUG, BB HANDLE 1023.00190.00 RED PLUG, BB HANDLE 1023.00191.00 GREEN PLUG, BB HANDLE 1023.00192.00 ORANGE PLUG, BB HANDLE 1023.00180.00 BLUE PLUG, BB HANDLE Stainless Steel Brew Basket Ref# Part Number Description Complete Stainless B001280B1 Steel Brew basket no clips (Standard) Complete Stainless B002280B1 Steel Brew basket with clips (Optional) 1 1112.00058.00 BB brew cone WLDMNT 2 1046.00025.00 BREW BASKET WARNING LABEL 3 1082.00040.00 SCREW, 1/4-20 X .5, FL HD, PH., W/NYLN 4 1009.00005.00 WIRE BASKET 5 6 Optional colored handle Optional colored handle Optional colored handle 1102.00064.00 1009.00003.00 1102.00065.00 1102.00066.00 1102.00067.00 HANDLE W/MAGNET ASY, BLACK CLIP, WIRE BASKET, NOTE!: Requires 4 clips HANDLE W/MAGNET ASY, RED HANDLE W/MAGNET ASY, GREEN HANDLE W/MAGNET ASY, ORANGE Go to fetco.com for the latest versions of all information Page 17 User Guide & Operator instructions P213e0 NOVEMBER 2021 Parts Diagram CBS-1251 Drawing 1101.00572.00 Parts CBS-1251 #6 Part Number1102.00471.00 ELECTRICAL COMPONENT LATTICE Go to fetco.com for the latest versions of all information Page 18 User Guide & Operator instructions P213e0 NOVEMBER 2021 Ref 1 2 3 4 5 6 6 REF 6-1 6-2 6-3 6-4 6-5 6-6 6-7 6-8 6-9 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 34 34 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 Qty Part Number 1 1111.00100.00 6 1084.00051.00. 1 1102.00480.00 2 1082.00029.00 2 1082.00058.00 1 1102.00471.00 1 Reference 1 1023.00350.00 1 1052.00023.00 2 1082.00056.00 2 1058.00024.00 4 1057.00043.00 2 1082.00010.00 1 1052.00059.00 2 1082.00020.00 2 1058.00055.00 1 1097.00171.00 1 1023.00390.00 1 1102.00450.00 2 1024.00107.00 1 1024.00108.00 2 1024.00106.00 1 1023.00343.00 2 1023.00342.00 10 1083.00010.00 10 1084.00006.00 1 1024.00098.00 1 1086.00004.00 1 1102.00243.00 2 1065.00009.00 1 1044.00012.00 12 1084.00011.00 1 1025.00058.00 1 1086.00009.00 4 1086.00003.00 1 1112.00529.00 1 1001.00402.00 1 1001.00403.00 12 1082.00017.00 1 1046.00035.00 1 1402.00097.10 1 1046.00003.00 1 1041.00033.00 1 1104.00165.00 1 1104.00166.00 1 1104.00167.00 1 1104.00168.00 1 B015280BN2BK 1 B001280B1BB 1 B002280B1BB 1 1402.00037.10 1 1402.00039.10 1 1402.00121.10 1 1024.00111.00 1 1023.00362.00 1 1013.00131.00 1 1023.00348.00 1 1071.00055.00 1 1084.00048.00 1 1003.00370.00 1 1025.00120.00 2 1024.00051.00 1 1023.00349.00 1 1023.00369.00 1 1057.00076.00 1 1029.00042.00 1 1023.00344.00 1 1102.00219.00 6 1083.00009.00 2 1084.00010.00 1 1003.00259.00 4 1073.00007.00 1 1086.00008.00 1 1086.00031.00 1 1086.00032.00 1 1044.00013.00 1 1052.00027.00 4 1084.00012.00 Description Drawing 1101.00572.00, CBS-1251 WELDMENT BODY, CBS-2251 NUT, HEX LOCKWASHER, #8-32, 18-8 ST. STL FRONT PANEL ASSY, SINGLE, PLUS SERIES SCREW, #6 X 3/8 LG, TRUSS HD PHIL, SHEET MTL SCREW, # 8-32 X 5/8, FLAT HD, PH, 18-8 SS ELECTRICAL COMPONENT LATTICE, NEXT GEN XV+ ELECTRICAL COMPONENT LATTICE, NEXT GEN XV+ ELECTRICAL MOUNTING LATTICE, COMMON EUROSTRIP HE16 TERM. BLOCK, 4 POLE, 63 AMP, 18-8 AWG SCREW, # 8-16 x 1" PAN HD PHIL, THREAD FORMING, FOR PLASTICS, 18-8 SS SWITCH, POWER, DOUBLE POLE, 16A, 125/250 VAC SOLENOID VALVE, 5.5L/min, 180 DEG, 24VDC SCREW, PAN HD. PHIL. MACH., M4x10 ZINC-PLATED POWER SUPPLY, 90-264VAC/24VDC, 2.25A SCREW, #6 X 5/8, TRUSS HD PHIL, SHEET MTL USB CONNECTOR ADHESIVE, RGB LED BAR LENS, LIGHT BAR, BLACK QUICK CONNECT SRAYHEAD ASSEMBLY, BASIC [See Page 24 for expanded drawing] O-RING, 1 3/16" OD X 1 1/16" ID X 1/16" TH, BYPASS SEAL O-RING, 5 11/16"OD X 5 1/2" ID X 3/32" TH, BREW SEAL O-RING, 13/16"OD X 11/16"ID X 1/16" TH, FOR QUICK CONNECT VENT INSERT, QUICK CONNECT QUICK CONNECT CLIP WASHER, #10 SCREW W/NEOPRENE-BONDED SEAL NUT, 8-32 18-8 HEX MACHINE SCREW VENT TUBE, CBS- EXTRACTOR SERIES BUSHING, SNAP, 1" MOUNTING HOLE ADAPTER ASSY, 3/4" BSP x 1/4" NPT x 3/8" TUBE GROUND LUG CONNECTOR, 14-2 AWG, ALUMINUM LABEL GROUND, CE NUT, CLIP ON (J-NUT), #6-32, 22-20 GA., BLK-PH FINISH TUBE, 9/16"OD X 5/16"ID X 25.00"LG CLAMP, 3/4" MAX TUBE OD FLOW CONTROL UNICLAMP, 15.9 HOSE OD CLAMP WELDMENT FRONT COVER, CBS-2250 COVER TOP, CBS-2251 COVER, UPPER BASE, CBS-2251 SCREW, TRUSS HD. PHIL. MACHINE, # 6-32 X 1/2 LG. LABEL, WARNING "TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE" WIRE HARNESS, CBS-1240/50, LOW AMP, UNIVERSAL LABEL, CSD WARNING, 1.5" X 5.0" BLACK EXTRACTOR PLUS LABEL, LASER ENGRAVED TANK ASSEMBLY, CBS-2251, 1 X 4KW/240VAC [See additional pages for expanded drawing] TANK ASSEMBLY, CBS-2251, 1 X 5KW/240VAC TANK ASSEMBLY, CBS-2251, 2 X 2.3KW/240VAC TANK ASSEMBLY, CBS-2251, 2 X 3KW/240VAC BREW BASKET ASSY, 16" X 6", 0.280" DIA HOLE, BROWN PLUG ASSY, 16" X 6", 0.280 DIA HOLE, BLACK ASSY, 16" X 6", 0.280" DIA HOLE, BLACK HARNESS HIGH AMP, CBS-2232/42/51, UL HARNESS HIGH AMP, CBS-2231/41/51, UL WIRE HARNESS ADDITION, HIGH AMP, EMI FILTER, 2-POLE, CE GROMMET, SILICONE, W/ POSITION TABS FITTING VENT, ELBOW, .375" X .375", SELF POSITIONING TUBE, 304SS, .625OD X .065 WALL X 11-1/2" LG. HOT WATER INSERT, MANUAL FAUCET FAUCET, HOT WATER, PSC-BR-8, WITH FLAT AND STEM JAM NUT, 1/2-20 UNF, NICKEL PLATED BRASS HOT WATER INSERT LOCK TUBE, 9/16"OD X 5/16"ID X 13.00"LG GROMMET, SILICONE, BLANK HOT WATER INSERT, NO FAUCET ORIFICE INSERT, QUICK CONNECT, 3/16" HOLE VALVE ASSEMBLY, COMPLETE, NG, DELTROL BYPASS L-TUBE, SILICONE, 2200 SINGLE SERIES PLUG INSERT, QUICK CONNECT ASSEMBLY, BB LOCKER, 24VDC WASHER, #6 SCREW , INTL TOOTH LOCKWASHER NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED BRACKET, BREW BASKET LOCK COVER LEG, FLANGE FOOT, 4" HIGH CONNECTOR, CLAMP, NON-METALLIC CABLE, 3/4" SKINTOP, 3/4" NPT, 0.354" - 0.630" DIA CABLE, BLK LOCKNUT, SKINTOP, 3/4" NPT, BLACK HEX LABEL EQUIPOTENTIALITY, CE EMI FILTER, THREE LINE 30A, 250/440VAC NUT, HEX, #6-32 MACHINE SCREW Go to fetco.com for the latest versions of all information Page 19 User Guide & Operator instructions P213e0 NOVEMBER 2021 Parts Diagrams CBS-1252 and CBS-1253 Parts lists for CBS-1252 1-1/2 gallon Drawing 1101.00573.00 CBS-1252 2 gallon Drawing 1101.00592.00 #6 Part Number1102.00471.00 ELECTRICAL COMPONENT LATTICE Go to fetco.com for the latest versions of all information Page 20 User Guide & Operator instructions P213e0 NOVEMBER 2021 REF 1 1 2 3 4 5 6 REF 6-1 6-2 6-3 6-4 6-5 6-6 6-7 6-8 6-9 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35 35 35 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 QTY 1 1 6 1 2 2 1 1 1 2 2 4 2 1 2 2 1 1 2 4 2 3 2 4 20 20 2 2 1 2 1 12 1 1 4 1 1 1 12 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 3 1 1 1 1 1 1 Part number 1111.00099.00 1111.00114.00 1084.00051.00 1102.00470.00 1082.00029.00 1082.00058.00 Reference 1023.00350.00 1052.00023.00 1082.00056.00 1058.00024.00 1057.00043.00 1082.00010.00 1052.00059.00 1082.00020.00 1058.00055.00 1097.00171.00 1023.00390.00 1102.00450.00 1024.00107.00 1024.00108.00 1024.00106.00 1023.00343.00 1023.00342.00 1083.00010.00 1084.00006.00 1024.00098.00 1086.00004.00 1102.00243.00 1065.00009.00 1044.00012.00 1084.00011.00 1025.00058.00 1086.00009.00 1086.00003.00 1112.00529.00 1001.00352.00 1001.00399.00 1082.00017.00 1046.00035.00 1402.00097.10 1402.00097.11 1046.00003.00 1041.00033.00 1104.00160.00 1104.00161.00 1104.00162.00 1104.00163.00 1104.00164.00 1402.00112.10 1402.00120.10 1022.00032.00 1066.00003.00 B015280BN2BK B001280B1BB B002280B1BB 1024.00111.00 1023.00362.00 1013.00131.00 1023.00348.00 1071.00055.00 1084.00048.00 1003.00370.00 1025.00120.00 1024.00051.00 1023.00349.00 1023.00369.00 1057.00076.00 1023.00344.00 1029.00042.00 1102.00219.00 1003.00259.00 1083.00009.00 1084.00010.00 1073.00007.00 1086.00008.00 1086.00031.00 1086.00032.00 1044.00013.00 1052.00050.00 1084.00012.00 Description Drawing 1101.00573.00, 1101.00059.00 Parts CBS-1252 and applies to CBS-1253 WELDMENT BODY, CBS-2252 1½ gallon brewer only WELDMENT BODY, CBS-2252 2 gallon brewer only NUT, HEX LOCKWASHER, #8-32, 18-8 ST. STL. FRONT PANEL ASSY, DOUBLE, PLUS SERIES SCREW, #6 X 3/8 LG, TRUSS HD PHIL, SHEET MTL SCREW, # 8-32 X 5/8, FLAT HD, PH, 18-8 SS ELECTRICAL COMPONENT LATTICE, NEXT GEN XV+ ELECTRICAL MOUNTING LATTICE, COMMON EUROSTRIP HE16 TERM. BLOCK, 4 POLE, 63 AMP, 18-8 AWG SCREW, # 8-16 x 1" PAN HD PHIL, THREAD FORMING, FOR PLASTICS, 18-8 SS SWITCH, POWER, DOUBLE POLE, 16A, 125/250 VAC SOLENOID VALVE, 5.5L/min, 180 DEG, 24VDC SCREW, PAN HD. PHIL. MACH., M4x10 ZINC-PLATED POWER SUPPLY, 90-264VAC/24VDC, 2.25A SCREW, #6 X 5/8, TRUSS HD PHIL, SHEET MTL USB CONNECTOR ADHESIVE, RGB LED BAR LENS, LIGHT BAR, BLACK QUICK CONNECT SRAYHEAD ASSEMBLY, BASIC [See Page 24 for expanded drawing] O-RING, 1 3/16" OD X 1 1/16" ID X 1/16" TH, BYPASS SEAL O-RING, 5 11/16"OD X 5 1/2" ID X 3/32" TH, BREW SEAL O-RING, 13/16"OD X 11/16"ID X 1/16" TH, FOR QUICK CONNECT VENT INSERT, QUICK CONNECT QUICK CONNECT CLIP WASHER, #10 SCREW W/NEOPRENE-BONDED SEAL NUT, 8-32 18-8 HEX MACHINE SCREW VENT TUBE, CBS- EXTRACTOR SERIES BUSHING, SNAP, 1" MOUNTING HOLE ADAPTER ASSY, 3/4" BSP x 1/4" NPT x 3/8" TUBE GROUND LUG CONNECTOR, 14-2 AWG, ALUMINUM LABEL GROUND, CE NUT, CLIP ON (J-NUT), #6-32, 22-20 GA., BLK-PH FINISH TUBE, 9/16"OD X 5/16"ID X 25.00"LG CLAMP, 3/4" MAX TUBE OD FLOW CONTROL UNICLAMP, 15.9 HOSE OD CLAMP WELDMENT FRONT COVER, CBS-2250 1½ gallon brewer and 2 gallon brewer COVER, UPPER BASE, CBS-1152 EXTRACTOR V+ COVER TOP, CBS-2252 SCREW, TRUSS HD. PHIL. MACHINE, # 6-32 X 1/2 LG. LABEL, WARNING "TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE" WIRE HARNESS, CBS-1240/50, LOW AMP, UNIVERSAL WIRE HARNESS ADDITION, CBS-1252, LOW AMP, UNIVERSAL LABEL, CSD WARNING, 1.5" X 5.0" BLACK EXTRACTOR PLUS LABEL, LASER ENGRAVED TANK ASSEMBLY, CBS-2252, 3 X 3KW/240VAC [See additional pages for expanded drawing] TANK ASSEMBLY, CBS-2252, 2 X 3KW/240VAC [See additional pages for expanded drawing] TANK ASSEMBLY, CBS-2252, 3 X 4KW/240VAC [See additional pages for expanded drawing] TANK ASSEMBLY, CBS-2252, 3 X 5KW/240VAC [See additional pages for expanded drawing] TANK ASSEMBLY, CBS-2252, 2 X 5KW/240VAC [See additional pages for expanded drawing] WIRE HARNESS, CBS-1252/61, HIGH AMP, 1 OR 3PH, 3 HEATERS, UL WIRE HARNESS, 3 HEATER, HIGH AMP, 3L-N-PE, 220/380-240/415, INTL/CE SLEEVE, Ø.50 x 2.0" LG. x 1.50" SLOT CABLE TIE, 3-7/8" LG., BLACK BREW BASKET ASSY BLACK, 16" X 6", 0.280" DIA HOLE, BROWN PLUG ASSY, 16" X 6", 0.280 DIA HOLE, BLACK ASSY, 16" X 6", 0.280" DIA HOLE, BLACK GROMMET, SILICONE, W/ POSITION TABS FITTING VENT, ELBOW, .375" X .375", SELF POSITIONING TUBE, 304SS, .625OD X .065 WALL X 11-1/2" LG. HOT WATER INSERT, MANUAL FAUCET FAUCET, HOT WATER, PSC-BR-8, WITH FLAT AND STEM JAM NUT, 1/2-20 UNF, NICKEL PLATED BRASS HOT WATER INSERT LOCK TUBE, 9/16"OD X 5/16"ID X 13.00"LG GROMMET, SILICONE, BLANK HOT WATER INSERT, NO FAUCET ORIFICE INSERT, QUICK CONNECT, 3/16" HOLE VALVE ASSEMBLY, COMPLETE, NG, DELTROL PLUG INSERT, QUICK CONNECT BYPASS L-TUBE, SILICONE, 2200 SINGLE SERIES ASSEMBLY, BB LOCKER, 24VDC BRACKET, BREW BASKET LOCK COVER WASHER, #6 SCREW , INTL TOOTH LOCKWASHER NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED LEG, FLANGE FOOT, 4" HIGH CONNECTOR, CLAMP, NON-METALLIC CABLE, 3/4" SKINTOP, 3/4" NPT, 0.354" - 0.630" DIA CABLE, BLK LOCKNUT, SKINTOP, 3/4" NPT, BLACK HEX LABEL EQUIPOTENTIALITY, CE EMI FILTER, 25A, 250/440VAC, 50/60Hz NUT, HEX, #6-32 MACHINE SCREW Go to fetco.com for the latest versions of all information Page 21 User Guide & Operator instructions P213e0 NOVEMBER 2021 CBS-1251 Tank Assembly CBS-1251 Hot water tank 1104.00165.00 and 1104.00166.00 1 X 4 kW & 1 x 5 kW REF 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 16 17 18 19 20 21 22 QTY 1 1 1 3 1 1 1 1 2 1 1 2 1 1 1 1 8 8 1 1 1 1 2 TANK ASSY, CBS-1251 Single Heater Drawing number 1104.000165.00 & 1104.000166.00 Part number Description 1114.00172.00 WELDMENT, TANK, CBS-2251 1024.00114.00 TANK GASKET - NG HEATER PLATE, TWO ELEMENT 1114.00184.00 WELDMENT TANK HEATER BRACKET, NG-2231, SINGLE 1024.00050.00 GROMMET, SILICONE, 11.4mm ID 1023.00166.00 FITTING, COLD WATER INLET, GROMMET DESIGN 1023.00203.00 FITTING, STRAIGHT, GROMMET, .625" 1003.00140.00 ALUMINUM BRACKET FOR SSR 1052.00033.00 RELAY, SOLID STATE, 50A/480VAC, W/BUILD IN VARISTOR 1081.00042.00 STANDOFF, 1/4" HEX 1107.00010.00 HEATER ASSEMBLY, IMMERSION 4kW/240VAC 1107.00032.00 HEATER ASSEMBLY, IMMERSION, 5kW/240VAC 1024.00053.00 LEVEL AND TEMP PROBE GROMMET 1023.00212.00" FITTING, ELBOW, GROMMET, .500 1112.00019.00 PROBE WELDMENT, WATER LEVEL 2.600" LG 1102.00161.00 PROBE ASSEMBLY, TEMP. AND LLC, 8" LONG 1053.00052.00 THERMOSTAT, SINGLE SHOT, SCREW CONNECTIONS, 240V/25A 1083.00009.00 WASHER, #6 SCREW , INTL TOOTH LOCKWASHER 1084.00010.00 NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED 1044.00004.00 LABEL, DANGER, HIGH VOLTAGE 1024.00051.00 GROMMET, SILICONE, BLANK 1022.00068.00 INSULATION, TANK FRONT, CBS-2151 1022.00069.00 INSULATION, TANK BACK, CBS-2151 1082.00136.00 BRASS SCREW, #8-32 X 1/4", PHILLIPS PAN HEAD Go to fetco.com for the latest versions of all information Page 22 User Guide & Operator instructions P213e0 NOVEMBER 2021 CBS-1251 Hot water tank 1104.00167.00 and 1104.00168 2 X 2.3 kW & 2 x 3 kW TANK ASSY, CBS-1251 Two Heater Drawing number 1104.000167.00 & 1104.00168.00 REF QTY Part number Description 1 1 1114.00172.00 WELDMENT, TANK, CBS-2251 2 1 1024.00114.00 TANK GASKET - NG HEATER PLATE, TWO ELEMENT 3 1 1114.00176.00 WELDMENT TANK HEATER BRACKET, NG-2231 4 3 1024.00050.00 GROMMET, SILICONE, 11.4mm ID 5 1 1023.00166.00 FITTING, COLD WATER INLET, GROMMET DESIGN 6 1 1023.00203.00 FITTING, STRAIGHT, GROMMET, .625" 7 2 1003.00140.00 ALUMINUM BRACKET FOR SSR 8 2 1052.00033.00 RELAY, SOLID STATE, 50A/480VAC, W/BUILD IN VARISTOR 9 4 1081.00042.00 STANDOFF, 1/4" HEX 10 2 1107.00037.00 HEATER ASSEMBLY, IMMERSION 2300W/240VAC 10 2 1107.00005.00 HEATER ASSEMBLY, IMMERSION 3000W/240VAC 11 2 1024.00053.00 LEVEL AND TEMP PROBE GROMMET 12 1 1023.00212.00 FITTING, ELBOW, GROMMET, .500" 13 1 1112.00019.00 PROBE WELDMENT, WATER LEVEL 2.600" LG 14 1 1102.00161.00 PROBE ASSEMBLY, TEMP. AND LLC, 8" LONG 15 2 1053.00052.00 THERMOSTAT, SINGLE SHOT, SCREW CONNECTIONS, 240V/25A 16 10 1083.00009.00 WASHER, #6 SCREW , INTL TOOTH LOCKWASHER 17 10 1084.00010.00 NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED 18 1 1024.00051.00 GROMMET, SILICONE, BLANK 19 1 1044.00004.00 LABEL, DANGER, HIGH VOLTAGE 20 1 1022.00068.00 INSULATION, TANK FRONT, CBS-2151 21 1 1022.00069.00 INSULATION, TANK BACK, CBS-2151 22 4 1082.00136.00 BRASS SCREW, #8-32 X 1/4", PHILLIPS PAN HEAD Go to fetco.com for the latest versions of all information Page 23 User Guide & Operator instructions P213e0 NOVEMBER 2021 CBS-1252 and CBS1253 Tank Assembly CBS-1252 Hot water tank 1104.00161.00; 1104.00164.00 2 X 3kW; 2x 5 kW Ref# 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 16 17 18 19 20 21 22 Qty 1 3 3 5 1 2 2 2 4 2 2 2 2 1 1 2 16 16 2 1 1 1 4 CBS-1252 Hot Water Tank Part number Drawing 1104.00161.00 & 1104.00164.00 Description 1114.00164.00 WELDMENT TANK, CBS-2252, LASER 1024.00115.00 TANK GASKET - NG HEATER PLATE, ONE ELEMENT 1114.00181.00 WELDMENT TANK HEATER BRACKET, NG-2232 1024.00050.00 GROMMET, SILICONE, 11.4mm ID 1023.00166.00 FITTING, COLD WATER INLET, GROMMET DESIGN 1023.00203.00 FITTING, STRAIGHT, GROMMET, .625" 1003.00140.00 ALUMINUM BRACKET FOR SSR 1052.00033.00 RELAY, SOLID STATE, 50A/480VAC, W/BUILD IN VARISTOR 1081.00042.00 STANDOFF, 1/4" HEX 1107.00005.00 ASSEMBLY, IMMERSION HEATER, 3000W, 240VAC 1107.00032.00 ASSEMBLY, IMMERSION HEATER, 5000W, 240VAC 1024.00053.00 LEVEL AND TEMP PROBE GROMMET 1023.00212.00 FITTING, ELBOW, GROMMET, .500" 1112.00019.00 PROBE WELDMENT, WATER LEVEL 2.600" LG 1102.00161.00 PROBE ASSEMBLY, TEMP. AND LLC, 8" LONG 1053.00052.00 THERMOSTAT, SINGLE SHOT, SCREW CONNECTIONS, 240V/25A 1083.00009.00 WASHER, #6 SCREW , INTL TOOTH LOCKWASHER 1084.00010.00 NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED 1024.00054.00 GROMMET, SILICONE PLUG 1044.00004.00 LABEL, DANGER, HIGH VOLTAGE 1022.00070.00 INSULATION, TANK FRONT, CBS-2152 1022.00071.00 INSULATION, TANK BACK, CBS-2152 1082.00136.00 BRASS SCREW, #8-32 X 1/4", PHILLIPS PAN HEAD Go to fetco.com for the latest versions of all information Page 24 User Guide & Operator instructions P213e0 NOVEMBER 2021 CBS-1252 Hot water tank 1104.00160.00; 1104.00162.00; 1104.00163.00 3 X 3kW; 3 X 4 kW & 3 x 5 kW Ref# 1 2 3 4 5 6 7 8 9 10 11 11 11 12 13 14 15 16 17 18 19 20 21 . CBS-1252 and CBS-1253 Hot Water Tank Drawing 1104.00160.00; 1104.00162.00; 1104,00163.00 Qty Part number Description 1 1114.00164.00 WELDMENT TANK, CBS-2252, LASER 3 1024.00115.00 TANK GASKET - NG HEATER PLATE, ONE ELEMENT 3 1114.00181.00 WELDMENT TANK HEATER BRACKET, NG-2232 2 1024.00053.00 LEVEL AND TEMP PROBE GROMMET 5 1024.00050.00 GROMMET, SILICONE, 11.4mm ID 1 1112.00019.00 PROBE WELDMENT, WATER LEVEL 2.600" LG 1 1102.00161.00 PROBE ASSEMBLY, TEMP. AND LLC, 8" LONG 2 1023.00212.00 FITTING, ELBOW, GROMMET, .500" 2 1023.00203.00 FITTING, STRAIGHT, GROMMET, .625" 1 1023.00166.00 FITTING, COLD WATER INLET, GROMMET DESIGN 1 1107.00005.00 ASSEMBLY, IMMERSION HEATER, 3000W, 240VAC 1 1107.00010.00 ASSEMBLY, IMMERSION HEATER, 4000W, 240VAC 1 1107.00032.00 ASSEMBLY, IMMERSION HEATER, 5000W, 240VAC 3 1053.00052.00 THERMOSTAT, SINGLE SHOT, SCREW CONNECTIONS, 240V/25A, 18 1083.00009.00 WASHER, #6 SCREW , INTL TOOTH LOCKWASHER 18 1084.00010.00 NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED 3 1003.00140.00 ALUMINUM BRACKET FOR SSR 3 1052.00033.00 RELAY, SOLID STATE, 50A/480VAC, W/BUILD IN VARISTOR 6 1081.00042.00 STANDOFF, 1/4" HEX 1 1044.00004.00 LABEL, DANGER, HIGH VOLTAGE 1 1022.00070.00 INSULATION, TANK FRONT, CBS-2152 1 1022.00071.00 INSULATION, TANK BACK, CBS-2152 6 1082.00136.00 BRASS SCREW, #8-32 X 1/4", PHILLIPS PAN HEAD Go to fetco.com for the latest versions of all information Page 25 User Guide & Operator instructions P213e0 NOVEMBER 2021 Quick connect spray head assembly CBS-2151; CBS-1252 and CBS-1253 1102.00450.00 QUICK CONNECT SRAYHEAD ASSEMBLY Ref# Qty Part number 1 1 1023.00341.00 Description BASE, QUICK CONNECT SPRAY HEAD 2 1 1102.00113.00 SWITCH, REED, ASSEMBLY 3 3 1023.00342.00 QUICK CONNECT CLIP 4 1 1102.00043.00 CASCADE SPRAY DOME, CBS-2050/60'S 5 2 1057.00076.00 VALVE ASSEMBLY, COMPLETE, NG, DELTROL (interchangeable with 1057.00078.00) 5 2 1057.00078.00 VALVE ASSEMBLY, COMPLETE, NG, RPE (interchangeable with 1057.00076.00) 6 2 1024.00107.00 O-RING, 1 3/16" OD X 1 1/16" ID X 1/16" TH, BYPASS SEAL 7 1 1024.00108.00 O-RING, 5 11/16"OD X 5 1/2" ID X 3/32" TH, BREW SEAL 8 1 1023.00369.00 ORIFICE INSERT, QUICK CONNECT, 3/16" HOLE 9 1 1023.00343.00 VENT INSERT, QUICK CONNECT 10 2 1024.00106.00 O-RING, 13/16"OD X 11/16"ID X 1/16" TH, FOR QUICK CONNECT 11 1 1024.00098.00 VENT TUBE, CBS- EXTRACTOR SERIES 12 1 1023.00344.00 PLUG INSERT, QUICK CONNECT Go to fetco.com for the latest versions of all information Page 26 User Guide & Operator instructions P213e0 NOVEMBER 2021 Wiring Diagrams CBS-1251 PLUS Wiring diagram 1401.00196.10 SKU: E1251US-1B230-PM110; heaters 2 X 3.0 kW SKU: E1251IN-1B230-PM110; heaters 2 X 3.0 kW Go to fetco.com for the latest versions of all information Page 27 User Guide & Operator instructions P213e0 NOVEMBER 2021 SSR CBS-1251 Plus Wiring Diagram 1401.00197.10 SKU E1251IN-1B140-PM110; heaters 1 X 4.0 kW SKU E1251IN-1B150-PM110 ; heaters 1 X 5.0 kW Go to fetco.com for the latest versions of all information Page 28 User Guide & Operator instructions P213e0 NOVEMBER 2021 SSR SSR SSR SSR THREE PHASE POWER L1, L2, & L3 L1 - #1, #31 L2 - #2, #32 L3 - #3, #33 SINGLE PHASE POWER L1 & L3 L2 - NOT CONNECTED L1 - #1, #31 L2 - #2, #33 L3 - #3, #32 CBS-1252 V PlusWiring Diagram 1401.00197.10 SKU E1253US-UB230-PM110 Heaters 2 X 3.0 kW single phase; 3 X 3.0 kW three phase SKU E1253US-UB250-PM110 Heaters 2 X 5.0 kW single phase; 3 X 5.0 kW three phase Go to fetco.com for the latest versions of all information Page 29 User Guide & Operator instructions P213e0 NOVEMBER 2021 SSR SSR CBS-1252 Plus Wiring Diagram 1401.00199.10 SKU E1252IN-1B230-PM110; heaters 2 X 3.0 kW SKU E1252IN-1B250-PM110, heaters 2 X 5.0 kW Go to fetco.com for the latest versions of all information Page 30 User Guide & Operator instructions P213e0 NOVEMBER 2021 SSR SSR SSR CBS-1252 PLUS CE Models SKU E1252IN-3B330-PM110; heaters3 X 3.0 kW 220/380 or 240/415 SKU E1252IN-3B340-PM110; heaters 3 X 4.0 kW 220/380 or 240/415 SKU E1252IN-3B350-PM110; heaters 3 X 5.0 kW 220/380 or 240/415 Go to fetco.com for the latest versions of all information Page 31 User Guide & Operator instructions P213e0 NOVEMBER 2021 End of section notes N