Instruction Manual for SecurityKey models including: RK-WS Radio Key, RK-WS, Radio Key

RK-WS/M Installation Instructions

trinitygate.com


File Info : application/pdf, 2 Pages, 591.13KB

PDF preview unavailable. Download the PDF instead.

RK-WS Installation Instructions ?v=1642713363
RADIO KEY® Installation Instructions

SWITCHPLATE INSTALLATION DIAGRAM

Use appropriate

Fastener

Mounting

Plate

¿

¿

¿ ¿

Reader

Housing

¿

3.28

¿

3/4" diameter through hole for cables.

Use supplied screw

¿

Mounting Surface

MULLION INSTALLATION DIAGRAM

3/4" Diameter through hole for cable and buzzer.

Use appropriate #6 Fastener

l

l

1.0"

INSTALLATION STEPS FOR RK-WS, RK65KS:

1. Drill holes as needed per installation

¿

diagram shown to the left.

2. Feed cable through 3/4" hole.

3. Attach the mounting plate to

4.50

the mounting surface with the

appropriate fasteners.

4. Attach the housing to the mounting

plate by inserting the two tabs inside

the top of the housing into the two

¿

slots at the top of the mounting plate.

3.20

¿

¿

5. Secure by installing supplied

screws into the hole at the bottom

of the reader.

6. Connect cable per wiring diagram shown below.

INSTALLATION STEPS FOR RK-WM, RK65K:

1. Drill holes as needed per installation diagram

shown to the left. 2. Feed cable through 3/4" hole.

1.60 ¿

¿

3. Attach reader to any flat surface

¿

with two #6 screws.

4. Snap label insert into front of

reader to cover screws.

LED Label Tabs Insert Here

3.50

l

l

l

1.3"

¿ ¿

l

¿

TYPICAL INSTALLATIONS STANDALONE READERS (RK-65K/RK65KS)

RED BLACK

+
12 POWER VDC SUPPLY

OUTPUT RELAY BLUE

MOV

READER YELLOW

LOCK POWER SUPPLY

STRIKE OR MAG LOCK

BROWN ORANGE

REMOTE OPEN NORMALLY OPEN SWITCH

µ

Note: Use separate power supplies for electric lock and for access control unit.

WIRING CONNECTIONS

RK-65K & RK65KS

RK-WM & RK-WS

WIRE COLOR

STANDALONE WIRING CONNECTIONS

WIEGAND OUTPUT WIRING CONNECTIONS

WIRING CONNECTIONS

RED

5-14 VDC +

5-14 VDC +

5-14 VDC +

BLACK

GROUND ---

GROUND ---

GROUND ---

YELLOW

LATCH RELAY

NOT NEEDED

BUZZER INPUT (1)

BLUE

LATCH RELAY

NOT NEEDED

HOLD

ORANGE

REMOTE OPEN (2)

GREEN LED INPUT (3, 1)

GREEN LED INPUT (1)

BROWN

REMOTE OPEN (2)

RED LED INPUT (3, 1)

RED LED INPUT (1)

GREEN

NOT NEEDED

DATA-0

WIEGAND DATA-0

WHITE

NOT NEEDED

DATA-1

WIEGAND DATA-1

(1) Connect to GROUND to activate (2) Input Programmed for Remote Open (3) Input Programmed for LED/Beeper Control

3321906 8136

PARTS SUPPLIED:
Access Control Unit MOV (RK65K & RK65KS only) Operating Guide (RK65K & RK65KS only) Installation Instructions all Models Log Sheet (RK-65K only) Mounting Plate (RK-WS, RK65KS only) 2, #6 Mounting Screws 1, 4x40 Screw (RK-WS, RK65KS only) 1, Security Screw (RK-WS, RK65KS only) Snap-In Labels (RK65K only)
ACCESSORIES (NOT INCLUDED):
RK600-PS: 9VDC plug-in power supply. It is designed to power the RK-65K and RK-65KS only, and requires 120 VAC input.
RK-BB: Back Box/Spacer (RK-WS & RK65KS) RK-HHP: Hand-Held Programmer (RK65K) SK-SR SecuRelayTM - Smart relay module, DPDT.

SPECIFICATIONS:

POWER REQUIREMENTS 5-14 VDC, 90 mA

OUTPUTS SPST Solid State Relay, 1A max. @60 VAC or DC Normally open or normally closed (field programmable (See Operating Guide). For RK-65K and RK-65KS only.

INPUTS Default is Remote Open (requires contact closure).
For RK-65K and RK-65KS only. Also programmable as Bicolor (Red or Green) LED Control or Buzzer/LED
control for online systems (see Operating Guide).

WIEGAND OUTPUT Any Wiegand Format up to 40 bits
Maximum Distance: 500 ft. - 5 or 6 conductor 20 gauge shielded cable

ENVIRONMENT

Access Control Unit, Key Tags and Cards

Ambient Temperature

-40° to +70°C (-40° to +158°F)

Humidity

0 to 95% (non-condensing)

INSTRUCTION TO THE USER FCC ID: NNHRK100M

This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more or the following measures:
 Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet of a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help. This equipment has been certified to comply with the limits for a class B computing device, pursuant to FCC Rules. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of the manufacturer could void the user's authority to operate this equipment.

3059349

CONFORMSTOUL STD.153
CERTIFIEDTOCSA STD.C22.2NO.12
SECURAKEY Models:
RK-WS/RK-WM RK-65KS/RK65K 5-14VDC,90mA

IP64 RoHS

3321906 8136

20301 Nordhoff Street, Chatsworth, CA 91311 PHONE (818) 882-0020 · FAX (818) 882-7052
TOLL-FREE (800) 891-0020 www.securakey.com mail@securakey.com



References