Instruction Manual for SecurityKey models including: RK-WS Radio Key, RK-WS, Radio Key
trinitygate.com
File Info : application/pdf, 2 Pages, 591.13KB
DocumentDocumentRADIO KEY® Installation Instructions SWITCHPLATE INSTALLATION DIAGRAM Use appropriate Fastener Mounting Plate ¿ ¿ ¿ ¿ Reader Housing ¿ 3.28 ¿ 3/4" diameter through hole for cables. Use supplied screw ¿ Mounting Surface MULLION INSTALLATION DIAGRAM 3/4" Diameter through hole for cable and buzzer. Use appropriate #6 Fastener l l 1.0" INSTALLATION STEPS FOR RK-WS, RK65KS: 1. Drill holes as needed per installation ¿ diagram shown to the left. 2. Feed cable through 3/4" hole. 3. Attach the mounting plate to 4.50 the mounting surface with the appropriate fasteners. 4. Attach the housing to the mounting plate by inserting the two tabs inside the top of the housing into the two ¿ slots at the top of the mounting plate. 3.20 ¿ ¿ 5. Secure by installing supplied screws into the hole at the bottom of the reader. 6. Connect cable per wiring diagram shown below. INSTALLATION STEPS FOR RK-WM, RK65K: 1. Drill holes as needed per installation diagram shown to the left. 2. Feed cable through 3/4" hole. 1.60 ¿ ¿ 3. Attach reader to any flat surface ¿ with two #6 screws. 4. Snap label insert into front of reader to cover screws. LED Label Tabs Insert Here 3.50 l l l 1.3" ¿ ¿ l ¿ TYPICAL INSTALLATIONS STANDALONE READERS (RK-65K/RK65KS) RED BLACK + 12 POWER VDC SUPPLY OUTPUT RELAY BLUE MOV READER YELLOW LOCK POWER SUPPLY STRIKE OR MAG LOCK BROWN ORANGE REMOTE OPEN NORMALLY OPEN SWITCH µ Note: Use separate power supplies for electric lock and for access control unit. WIRING CONNECTIONS RK-65K & RK65KS RK-WM & RK-WS WIRE COLOR STANDALONE WIRING CONNECTIONS WIEGAND OUTPUT WIRING CONNECTIONS WIRING CONNECTIONS RED 5-14 VDC + 5-14 VDC + 5-14 VDC + BLACK GROUND --- GROUND --- GROUND --- YELLOW LATCH RELAY NOT NEEDED BUZZER INPUT (1) BLUE LATCH RELAY NOT NEEDED HOLD ORANGE REMOTE OPEN (2) GREEN LED INPUT (3, 1) GREEN LED INPUT (1) BROWN REMOTE OPEN (2) RED LED INPUT (3, 1) RED LED INPUT (1) GREEN NOT NEEDED DATA-0 WIEGAND DATA-0 WHITE NOT NEEDED DATA-1 WIEGAND DATA-1 (1) Connect to GROUND to activate (2) Input Programmed for Remote Open (3) Input Programmed for LED/Beeper Control 3321906 8136 PARTS SUPPLIED: Access Control Unit MOV (RK65K & RK65KS only) Operating Guide (RK65K & RK65KS only) Installation Instructions all Models Log Sheet (RK-65K only) Mounting Plate (RK-WS, RK65KS only) 2, #6 Mounting Screws 1, 4x40 Screw (RK-WS, RK65KS only) 1, Security Screw (RK-WS, RK65KS only) Snap-In Labels (RK65K only) ACCESSORIES (NOT INCLUDED): RK600-PS: 9VDC plug-in power supply. It is designed to power the RK-65K and RK-65KS only, and requires 120 VAC input. RK-BB: Back Box/Spacer (RK-WS & RK65KS) RK-HHP: Hand-Held Programmer (RK65K) SK-SR SecuRelayTM - Smart relay module, DPDT. SPECIFICATIONS: POWER REQUIREMENTS 5-14 VDC, 90 mA OUTPUTS SPST Solid State Relay, 1A max. @60 VAC or DC Normally open or normally closed (field programmable (See Operating Guide). For RK-65K and RK-65KS only. INPUTS Default is Remote Open (requires contact closure). For RK-65K and RK-65KS only. Also programmable as Bicolor (Red or Green) LED Control or Buzzer/LED control for online systems (see Operating Guide). WIEGAND OUTPUT Any Wiegand Format up to 40 bits Maximum Distance: 500 ft. - 5 or 6 conductor 20 gauge shielded cable ENVIRONMENT Access Control Unit, Key Tags and Cards Ambient Temperature -40° to +70°C (-40° to +158°F) Humidity 0 to 95% (non-condensing) INSTRUCTION TO THE USER FCC ID: NNHRK100M This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more or the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet of a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This equipment has been certified to comply with the limits for a class B computing device, pursuant to FCC Rules. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of the manufacturer could void the user's authority to operate this equipment. 3059349 CONFORMSTOUL STD.153 CERTIFIEDTOCSA STD.C22.2NO.12 SECURAKEY Models: RK-WS/RK-WM RK-65KS/RK65K 5-14VDC,90mA IP64 RoHS 3321906 8136 20301 Nordhoff Street, Chatsworth, CA 91311 PHONE (818) 882-0020 · FAX (818) 882-7052 TOLL-FREE (800) 891-0020 www.securakey.com mail@securakey.com