Installation Guide for Altronix models including: T1SAK34 4 Door Kit with Fused Outputs, T1SAK34, 4 Door Kit with Fused Outputs, Fused Outputs
2022-01-22 — Maximum Supply. Current for Main and. Aux. Outputs on Power. Supply board and ACM4/. ACM8 Access Power. Controller's outputs.
Altronix T2SAK78 8-Door Altronix/Salto Access and Power Integration Kit, Trove2SA2 with AL1024ULXB2, ACM8, VR6, PDS8 | 123 Security Products
Altronix T1SAK34 4-Door Altronix/Salto Access and Power Integration Kit, Trove1SA1 with AL600ULXB, PDS8, VR6, ACM4 | 123 Security Products
File Info : application/pdf, 8 Pages, 1,023.04KB
DocumentDocumentAccess & Power Integration Altronix/SALTO Kits Models Include: T1SAK34 4 Door Kit with Fused Outputs Fully assembled kit includes: - Trove1 enclosure with TSA1 Altronix/SALTO backplane - (1) AL600ULXB - Power Supply/Charger - (1) ACM4 - Fused Access Power Controller - (1) VR6 - Voltage Regulator - (1) PDS8 - Dual Input Power Distribution Module T2SAK78 8 Door Kit with Fused Outputs Fully assembled kit includes: - Trove2 enclosure with TSA2 Altronix/SALTO backplane - (1) AL1024ULXB2 - Power Supply/Charger - (1) ACM8 - Fused Access Power Controller - (1) VR6 - Voltage Regulator - (1) PDS8 - Dual Input Power Distribution Module T2SAK7512 12 Door Kit with Fused Outputs Fully assembled kit includes: - Trove2 enclosure with TSA2 Altronix/SALTO backplane - (1) AL1024ULXB2 - Power Supply/Charger - (1) AL1012ULXB - Power Supply/Charger - (1) ACM8 - Fused Access Power Controller - (1) ACM4 - Fused Access Power Controller - (1) PDS8 - Dual Input Power Distribution Module All components of these Trove kits are UL Listed sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information. Installation Guide All registered trademarks are property of their respective owners. More than just power.TM Rev. TSAKL122121 Installing Company: _________________________ Service Rep. Name: __________________________________________ Address: _________________________________________________________ Phone #: _________________________ Overview: Altronix Trove SALTO kits are pre-assembled and consist of Trove1SA1 or Trove2SA2 enclosure/backplane with factory installed Altronix power supply/charger(s) and sub-assemblies. These kits also accommodate various combinations of SALTO modules for up to twelve (12) doors in a single enclosure. 115VAC 60Hz Input Current (A) Power Supply Board Input Fuse Rating Power Supply Board Battery Fuse Rating Fail-Safe/Fail-Secure or Dry Form "C" Outputs Current Per ACM4/ACM8 Output (A) ACM4/ACM8 Board Input Fuse Rating ACM4/ACM8 Board Output Fuse Rating PDS8 Board Input Fuse Rating PDS8 Board Output Fuse Rating Altronix Model Number T1SAK34 T2SAK78 T2SAK7512 Configuration Chart: Nominal DC Output Voltage Power Supply 1 Output Range (VDC) Power Supply 2 Output Range (VDC) Maximum Supply Current for Main and Aux. Outputs on Power Supply board and ACM4/ ACM8 Access Power Controller's outputs 3.5 5A/ 250V N/A 20.19-26.4 24VDC @ 5.6A 4 2.5 10A/ 32V 3A/ 32V 10A/ 32V 3A/ 32V 4.2 5A/ 250V 15A/ 32V 20.17-26.4 24VDC @ 9.2A 8 2.5 10A/ 2.5A/ 10A/ 250V 250V 32V 3A/ 32V 6.8 5A/ 250V 15A/ 32V 20.17-26.4 10.0313.2 12VDC @ 9.3A 24VDC @ 9.2A 12 2.5 10A/ 2.5A/ 10A/ 250V 250V 32V 3A/ 32V Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane(s) from enclosure. Do not discard hardware. 2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure's upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws. 3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2" from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the Fig. 1 appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. Enclosure 4. Mount SALTO modules to TSA2 backplane, refer to pg. 3, 4, 5. 5. Refer to the ULXB Power Supply/Charger Installation Guide for AL600ULXB, AL1012ULXB, AL1024ULXB2 and corresponding Sub-Assembly Installation Guides for Edge of Enclosure ACM4, ACM8, PDS8, VR6 for further installation instructions. Tamper Switch Hardware: (included) Nylon Spacer | 5/16" Pan Head Screw | Lock Nut To Access Control Panel or UL Listed Reporting Device - 2 - Trove SALTO ULXB Kits Installation Guide T1SAK34: Configuration of SALTO Modules: 1. Fasten spacers onto metal pems configuration (A) of backplane (Fig. 2, pg. 3). 2. Position SALTO modules over corresponding spacers and mount them utilizing pan head screws (provided) (Fig. 2a, pg. 3). 3. Mount backplane to enclosure with hardware. Access Controller Position Chart for the Following Models: SALTO Access Controller CU42E0, CU4200 or CU4EB8 Pem Mounting A Fig. 2 Backplane Fig. 2a PWR1+ Altronix - PDS8 IN1 Fuse PWR1+ Fuse1 Fuse2 Fuse3 Fuse4 Fuse5 Fuse6 Fuse7 Fuse8 IN2 Fuse + INP1 - + INP2 - LG N Altronix AL600ULXB P P COM (-) PWR2+ OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 N 1 2 3 4 5 6 7 8 Common Power Outputs (NEG) N COM (-) PWR2+ Altronix VR6 is mounted under PDS8 Pem Spacer HS4 Module Pan Head Screw AC DC BAT BAT FAIL NC C NO NC C NO AC FAIL +INP- T +RETINTERFACE NO C NC FACP +BAT- + DC - ON OFF - 24V ON - 12V TRIGGER INPUT TRG IN GND IN GND IN GND IN GND 1 2 3 4 LED1 LED2 LED3 LED4 Altronix - ACM4 MAIN NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 -- + -- + POWER CONTROL A A Trove SALTO ULXB Kits Installation Guide - 3 - T2SAK78: Configuration of SALTO Modules: 1. Fasten spacers onto metal pems configuration (A) of backplane (Fig. 3, pg. 4). 2. Position SALTO modules over corresponding spacers and mount them utilizing pan head screws (provided) (Fig. 3a, pg. 4). 3. Mount backplane to enclosure with hardware. Access Controller Position Chart for the Following Models: SALTO Access Controller CU42E0, CU4200 or CU4EB8 Pem Mounting A Fig. 3 Backplane Fig. 3a + DC - BAT FAIL NC C NO NC C NO AC FAIL AC DC - BAT + Altronix AL1024ULXB2 AC DELAY A A Pem Spacer HS4 Module Pan Head Screw L G N ACM8 ACCESS POWER CONTROLLER TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 FACP TRG INTERFACE NO C NC +INP- T + RET- F8 ON ON FACP 1234 1234 Altronix ACM8 MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 A A -+-+ Power Control Altronix - PDS8 PWR1+ Fuse1 IN1 Fuse Fuse2 Fuse3 Fuse4 Fuse5 Fuse6 Fuse7 PWR1+ Fuse8 IN2 Fuse + INP1 - + INP2 - P P COM (-) PWR2+ OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 N 1 2 3 4 5 6 7 8 Common Power Outputs (NEG) N COM(-) PWR2+ Altronix VR6 is mounted under PDS8 - 4 - Trove SALTO ULXB Kits Installation Guide T2SAK7512: Configuration of SALTO Modules: 1. Fasten spacers onto metal pems configuration (A) of backplane (Fig. 4, pg. 5). 2. Position SALTO modules over corresponding spacers and mount them utilizing pan head screws (provided) (Fig. 4a, pg. 5). 3. Mount backplane to enclosure with hardware. Access Controller Position Chart for the Following Models: SALTO Access Controller CU42E0, CU4200 or CU4EB8 Pem Mounting A Fig. 4 Backplane Fig. 4a + DC - BAT FAIL NC C NO NC C NO AC FAIL AC DC - BAT + Altronix AL1024ULXB2 AC DELAY A A Pem Spacer HS4 Module Pan Head Screw L G N - DC + + BAT - AC DC Altronix AL1012ULXB LG N BAT FAIL NC C NO NC C NO AC FAIL INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON FACP 1234 1234 Altronix ACM8 MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 -+-+ Power Control A A A A N Common(-) DM2+ DM1+ Fuse8 LED1 P 8 7 OUT5 OUT6 OUT7 OUT8 Fuse7 IN GND IN GND IN GND IN GND 1 2 LED2 Fuse6 6 Common Power Outputs (NEG) Dual Voltage Power PDS8 Distribution Module 3 4 LED3 NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 5 Fuse5 TRIGGER INPUT OUTPUT 3 4 3 OUT1 OUT2 OUT3 OUT4 Fuse4 LED4 OUTPUT 4 ACM4 ACCESS POWER CONTROLLER Altronix ACM4 MAIN TRG -- + -- + POWER CONTROL NO C NC FACP +INP- T +RETINTERFACE DM1+ IN1 Fuse Fuse1 Fuse2 Fuse3 P IN2 Fuse + INP1 - + INP2 - Altronix - PDS8 Common(-) DM2+ N 1 2 Trove SALTO ULXB Kits Installation Guide - 5 - Notes: - 6 - Trove SALTO ULXB Kits Installation Guide T1SAK34 Enclosure Dimensions (H x W x D): 18" x 14.5" x 4.625" (457mm x 368mm x 118mm) 14.5" (321.3mm) 7.25" (184.2mm) 1.45" (36.8mm) 1.95" (49.5mm) 1.5" (38.1mm) 4.5" (114.3mm) 1.25" (31.8mm) 0.57" (14.5mm) 0.6" (15.2mm) 13.0" (330.2mm) 1.25" (31.8mm) 1.5" (38.1mm) 8.5" (215.9mm) 8.5" (215.9mm) 18.0" (457.2mm) 6.5" (165.1mm) 6.5" (165.1mm) 0.6" (15.2mm) 1.1" (27.9mm) 4.5" (114.3mm) 4.5" (114.3mm) 2.75" (69.9mm) 1.115" (28.3mm) 1.36" (34.5mm) 1.25" (31.8mm) - 7 - Trove SALTO ULXB Kits Installation Guide T2SAK78 and T2SAK7512 Enclosure Dimensions (H x W x D): 27.25" x 21.75" x 6.5" (692.15mm x 552.5mm x 165.1mm) 2.00" (50.8mm) 21.50" (546.1mm) 5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm) 2.00" (50.8mm) 6.25" (158.8mm) 1.25" (31.8mm) 6.25" (158.8mm) 1.25" (31.8mm) 1.5" (38.1mm) 0.5625" (14.3mm) 0.685" (17.4mm) 1.77" (45mm) Knockouts 1.125" (28.3mm) 2.415" (61.3mm) 0.885" (22.5mm) 19.80" (502.9mm) 2.00" (50.8mm) 6.75" (171.5mm) 8.25" (209.5mm) 27" (685.8mm) 8.00" (203.2mm) 1.00" (25.4mm) 0.85" (21.6mm) 1.25" (31.8mm) 2.00" (50.8mm) 2.00" (50.8mm) 5.25" (133.4mm) 7.00" (177.8mm) 5.25" (133.4mm) 1.25" (31.8mm) 2.00" (50.8mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IITrove SALTO ULXB Kits L21U MEMBER - 8 - Trove SALTO ULXB Kits Installation Guide