Instructions for Kaysun models including: KCIA-26 DVR15 Commercial Range, KCIA-26 DVR15, Commercial Range, Range
The Kaysun R-32 commercial range includes axial outdoor units, in ... KCI-26 DR15. KCI-35 DR15. KCI-52 DR15. Air flow low / medium / high m³/h. 330 ...
File Info : application/pdf, 14 Pages, 38.35MB
DocumentDocumentZEN COCMOMMMEERCRIALCRIAANGLE RANGE The Kaysun R-32 commercial range includes axial outdoor units, in addition to several types of indoor units. The Kaysun outdoor units are compact, robust machines that require little space for installation. They can be used with Full DC Inverter The exclusive Kaysun GENIUS CORE algorithm provides the system with complete stability. Using the Alpha chip, the compressor, PWM module and DC motors in the unit work in an optimum way, adapting to the real demand and preventing losses of energy. The dynamic adjustment of the electrical power guarantees constant equilibrium for the system, meaning the Kaysun when operating for long periods. i-Balance Opreation WiFi It is possible to control Kaysun units via a tablet or smartphone as an option. The units can be managed remotely and they even have a weekly programmer. Twins Within the range it is possible to install TWIN-type units, meaning the installation of two indoor units which provide greater distribution of air while improving climate control, in conjunction with a single outdoor unit. CASSETTE (600x600) KID-06 S Standard R-32 DRAINAGE REFRIGERANT PUMP HERTZ COMPATIBLE SMART HOME WITH AIRZONE ON/OFF CONTACT FRESH AIR SUPPLY Set Model Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP SEER SCOP Shielded communication wiring Outdoor unit Air flow Sound pressure Sound power level Width / Height / Depth Net weight Power supply Power wiring Indoor unit Air flow low / medium / high Sound pressure Sound power level Width / Height / Depth Net weight Power supply Panel; Model Panel; Width / Height / Depth Panel; Net weight Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length Working range Outdoor ambient temperature for cooling min. / max. Outdoor ambient temperature for heating min. / max. kW kW kW kW W W W W mm² m³/h dB(A) dB(A) mm kg V/ph/Hz mm² m³/h dB(A) dB(A) mm kg V/ph/Hz mm kg kg inch m m °C °C KCIA-26 DVR15 2.63 0.35 / 3.07 3,07 0.90 / 3.51 800 145 / 1100 1000 300 / 1300 3.29 3.07 6.3 - A++ 4.1 - A+ 4x1 KUE-26 DVR14 2000 54 765 / 555 / 303 24.6 220-240/1/50 (2+T)x2,5 KCI-26 DR15 330 / 520 / 620 25.5 / / 31.5 / 38.5 / / 42 / 55 570 / 245 / 570 16.2 With communication KPA-03B 600x600 620 / 50 / 620 2.7 R-32 0.65 1/4" / 3/8" 25 10 -15 / 50 -15 / 24 Provisional data FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132 KCIA-35 DVR15 3.52 0.85 / 4.16 3.81 0.47 / 4.34 1015 160 / 1450 1020 125 / 1390 3.47 3.73 6.8 - A++ 4.1 - A+ 4x1 KUE-35 DVR13 2000 54 61 765 / 555 / 303 24.6 220-240/1/50 (2+T)x2,5 KCI-35 DR15 330 / 520 / 620 25.5 / / 31.5 / 38.5 / / 42 / 55 570 / 245 / 570 16.2 With communication KPA-03B 600x600 620 / 50 / 620 2.7 R-32 0.71 1/4" / 3/8" 25 10 -15 / 50 -15 / 24 KCIA-52 DVR15 5.28 2.9 / 5.59 5.57 2.37 / 6.1 1550 720 / 2040 1560 700 / 1950 3.41 3.57 6.5 - A++ 4.1 - A+ 4x1 KUE-52 DVR13 2100 56 62 805 / 555 / 330 32.5 220-240/1/50 (2+T)x2,5 KCI-52 DR15 300 / 540 / 660 25 / / 31.5 / 41 / / 44 / 59 570 / 245 / 570 16.2 With communication KPA-03B 600x600 / / R-32 1.15 1/4" / 1/2" 30 20 -15 / 50 -15 / 24 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. CASSETTE (840x840) KID-06 S Standard R-32 REFRIGERANT HERTZ COMPATIBLE SMART HOME WITH AIRZONE ON/OFF CONTACT FOLLOW ME FRESH AIR SUPPLY Set model Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Heating capacity rated at -7°C Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP COP at -7°C SEER SCOP Shielded communication wiring Outdoor unit Air flow Sound pressure Sound power level Width / Height / Depth Net weight Power supply Power wiring Indoor unit Air flow low / medium / high Sound pressure low / medium / high Sound power level Width / Height / Depth Net weight Power supply Power wiring Panel; Model Panel; Width / Height / Depth Panel; Net weight Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length Working range Outdoor ambient temperature for cooling min. / max. Outdoor ambient temperature for heating min. / max. kW kW kW kW kW W W W W mm² m³/h dB(A) dB(A) mm kg V/ph/Hz mm² m³/h dB(A) dB(A) mm kg V/ph/Hz mm² mm kg kg inch m m °C °C KCISA-71 DVR15 7.03 3.3 / 7.91 7.52 2.79 / 8.50 3.31 2320 780 / 2750 1900 610 / 2300 2.88 4.10 2.65 6.3 - A++ 4.1 - A+ 4x1 KUE-71 DVR14 3500 60 68 890 / 673 / 342 41.9 220-240/1/50 (2+T)x2,5 KCIS-71 DR14 992 / 1118 / 1247 42 / 47.5 / 50 59 830 / 205 / 830 21.6 With communication With communication LCAC KPA4-04B 840x840 950 / 55 / 950 6 R-32 1.9 3/8" / 5/8" 50 25 -15 / 50 -15 / 24 KCISA-90 DVR15 8.79 2.23 / 9.38 9.38 2.7 / 9.73 6.55 2750 190 / 3000 2450 430 / 2550 3.2 4 2.55 6.6 - A++ 4.2 - A+ 4x1 KUE-90 DVR14 3800 62 70 946 / 810 / 410 51 220-240/1/50 (2+T)x2,5 KCIS-90 DR14 1300 / 1530 / 1700 46 / 48 / 50.5 63 830 / 245 / 830 24.6 With communication With communication LCAC KPA4-04B 840x840 950 / 55 / 950 6 R-32 2 3/8" / 5/8" 50 25 -15 / 50 -15 / 24 KCISA-105 DVR14 10.55 2.7 / 11.43 11.14 2.78 / 12.66 7.52 4000 890 / 4150 3000 780 / 4000 2.65 3.68 2.6 6.1 - A++ 4 - A+ 4x1 KUE-105 DVR13 4000 63 70 946 / 810 / 410 66.900 220-240/1/50 (2+T)x4 KCIS-105 DR14 1300 / 1530 / 1700 46 / 49 / 51 64 830 / 245 / 830 27.2 With communication With communication LCAC KPA4-04B 840x840 950 / 55 / 950 6 R-32 2.4 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. KID-06 S Standard Set model Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Heating capacity rated at -7°C Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP COP at -7°C SEER SCOP Shielded communication wiring Outdoor unit Air flow Sound pressure Sound power level Width / Height / Depth Net weight Power supply Power wiring Indoor unit Air flow low / medium / high Sound pressure low / medium / high Sound power level Width / Height / Depth Net weight Power supply Power wiring Panel; Model Panel; Width / Height / Depth Panel; Net weight Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length Working range Outdoor ambient temperature for cooling min. / max. Outdoor ambient temperature for heating min. / max. kW kW kW kW kW W W W W mm² m³/h dB(A) dB(A) mm kg V/ph/Hz mm² m³/h dB(A) dB(A) mm kg V/ph/Hz mm² mm kg kg inch m m °C °C KCISA-140 DTR15 14.07 3.52 / 15.83 16.12 4.20 / 17.29 9.74 4980 810 / 6350 4580 900 / 5500 3.03 3.5 2.68 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DTR14 5600 64 73 990 / 975 / 375 90.0 380-415/3/50 (4+T)x2,5 KCIS-140 DR14 1600 / 1750 / 1900 48 / 50.5 / 52.5 66 830 / 287 / 830 29.3 With communication With communication LCAC KPA4-04B 840x840 950 / 55 / 950 6 R-32 2.9 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132 KCISA-160 DTR15 15.24 4.10 / 16.12 18.17 4.40 / 19.05 10.53 5700 1000 / 6250 5700 1020 / 6350 2.95 3.22 2.59 6.1 - A++ 4.0 - A+ 4x1 KUE-160 DTR14 5600 65 75 990 / 975 / 375 92.0 380-415/3/50 (4+T)x2,5 KCIS-160 DR14 1650 / 1850 / 2000 49.5 / 52 / 54.5 66 830 / 287 / 830 29.3 With communication With communication LCAC KPA4-04B 840x840 950 / 55 / 950 6 R-32 3 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. KID-06 S Standard FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132 Set model Set Cooling capacity rated kW Cooling capacity min. / max. kW Heating capacity rated kW Heating capacity min. / max. kW Heating capacity rated at -7°C kW Cooling input rated W Cooling input min. / max. W Heating input rated W Heating input min. / max. W EER COP COP at -7°C SEER SCOP Shielded communication wiring mm² Outdoor unit Air flow m³/h Sound pressure dB(A) Sound power level dB(A) Width / Height / Depth mm Net weight kg Power supply V/ph/Hz Power wiring mm² Indoor unit Air flow low / medium / high m³/h Sound pressure low / medium / high dB(A) Sound power level dB(A) Width / Height / Depth mm Net weight kg Power supply V/ph/Hz Power wiring mm² Refrigerant Type refrigerant Refrigerant charge kg Liquid / Gas pipe diameter inch Piping total length m Vertical piping max. length m Working range Outdoor ambient temperature for cooling min. / max. °C Outdoor ambient temperature for heating min. / max. °C KPCA-140 DTR15 14.07 3.52 / 15.24 16.12 4.10 / 17.59 9.91 5000 910 / 6200 4800 950 / 5950 2.83 3.07 2.65 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DTR14 5600 64 73 990 / 975 / 375 90.0 380-415/3/50 (4+T)x2,5 KPC-140 DR14 1600 / 1850 / 2200 46 / 50 / 53 67 1650 / 235 / 675 41.7 With communication With communication R-32 2.4 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 KPCA-160 DTR15 15.24 4.10 / 16.12 18.17 4.40 / 19.35 10.53 5900 1100 / 6500 5950 1120 / 6350 2.76 3 2.6 6.1 - A++ 4.0 - A+ 4x1 KUE-160 DTR14 5600 65 75 990 / 975 / 375 92.0 380-415/3/50 (4+T)x4 KPC-160 DR14 1650 / 1950 / 48 / 52 / 55 67 1650 / 235 / 675 42.3 With communication With communication R-32 2.8 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. Floor/Ceiling KID-06 S Standard R-32 DC INVERTER DC INVERTER REFRIGERANT COMPRESSOR EXTERNAL FAN HERTZ COMPATIBLE SMART HOME WITH AIRZONE ON/OFF CONTACT FOLLOW ME FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132 Set model Set Cooling capacity rated kW Cooling capacity min. / max. kW Heating capacity rated kW Heating capacity min. / max. kW Heating capacity rated at -7°C kW Cooling input rated W Cooling input min. / max. W Heating input rated W Heating input min. / max. W EER COP COP at -7°C SEER SCOP Shielded communication wiring mm² Outdoor unit Air flow m³/h Sound pressure dB(A) Sound power level dB(A) Width / Height / Depth mm Net weight kg Power supply V/ph/Hz Power wiring mm² Indoor unit Air flow low / medium / high m³/h Sound pressure low / medium / high dB(A) Sound power level dB(A) Width / Height / Depth mm Net weight kg Power supply V/ph/Hz Power wiring mm² Refrigerant Type refrigerant Refrigerant charge kg Liquid / Gas pipe diameter inch Piping total length m Vertical piping max. length m Working range Outdoor ambient temperature for cooling min. / max. °C Outdoor ambient temperature for heating min. / max. °C KPCA-52 DVR14 5.28 2.71 / 5.86 5.57 2.42 / 6.3 3.54 1450 670 / 2027 1500 540 / 1640 3.7 3.75 2.88 6.1 - A++ 4 - A+ 4x1 KUE-52 DVR13 2100 56 65 805 / 555 / 330 32.5 220-240/1/50 (2+T)x1,5 KPC-52 DR14 723 / 839 / 958 37 / 41 / 44 59 1068 / 235 / 675 28 With communication With communication R-32 1.15 1/4" / 1/2" 30 20 -15 / 50 -15 / 24 KPCA-71 DVR15 7.03 3.22 / 7.95 7.62 2.72 / 8.50 4.87 2300 750 / 2730 1980 650 / 2940 2.95 4 2.72 6.1 - A++ 4.1 - A+ 4x1 KUE-71 DVR14 3500 60 68 890 / 673 / 342 41.9 220-240/1/50 (2+T)x2,5 KPC-71 DR14 853 / 1023 / 1192 43 / 47 / 51 55 1068 / 235 / 675 28 With communication With communication R-32 1.5 3/8" / 5/8" 50 25 -15 / 50 -15 / 24 KPCA-105 DVR14 10.55 2.73 / 11.78 11.72 2.81 / 12.78 7.61 4000 890 / 4300 3350 780 / 3950 2.6 3.6 2.5 6.1 - A++ 4 - A+ 4x1 KUE-105 DVR13 3800 62 70 946 / 810 / 410 52.8 220-240/1/50 (2+T)x4 KPC-105 DR14 1504 / 1728 / 1955 45 / 47.5 / 51 65 1650 / 235 / 675 41.5 With communication With communication R-32 2 3/8" / 5/8" 50 25 -15 / 50 -15 / 24 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. KID-06 S Standard R-32 DC INVERTER DC INVERTER REFRIGERANT COMPRESSOR EXTERNAL FAN HERTZ COMPATIBLE SMART HOME WITH AIRZONE ON/OFF CONTACT FOLLOW ME FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132 Set model Set Cooling capacity rated kW Cooling capacity min. / max. kW Heating capacity rated kW Heating capacity min. / max. kW Heating capacity rated at -7°C kW Cooling input rated W Cooling input min. / max. W Heating input rated W Heating input min. / max. W EER COP COP at -7°C SEER SCOP Shielded communication wiring mm² Outdoor unit Air flow m³/h Sound pressure dB(A) Sound power level dB(A) Width / Height / Depth mm Net weight kg Power supply V/ph/Hz Power wiring mm² Indoor unit Air flow low / medium / high m³/h Sound pressure low / medium / high dB(A) Sound power level dB(A) Width / Height / Depth mm Net weight kg Power supply V/ph/Hz Power wiring mm² Refrigerant Type refrigerant Refrigerant charge kg Liquid / Gas pipe diameter inch Piping total length m Vertical piping max. length m Working range Outdoor ambient temperature for cooling min. / max. °C Outdoor ambient temperature for heating min. / max. °C KPCA-105 DTR14 10.55 2.73 / 11.43 11.72 2.78 / 12.78 7.61 3900 900 / 4250 3350 800 / 3950 2.6 3.6 2.5 6.1 - A++ 4 - A+ 4x1 KUE-105 DTR13 4000 63 70 946 / 810 / 410 66.90 380-415/3/50 (4+T)x2,5 KPC-105 DR14 1504 / 1728 / 2100 45 / 48 / 51.5 65 1650 / 235 / 675 41.5 With communication With communication R-32 2.4 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 KPCA-125 DVR14 12.02 2.93 / 12.31 13.48 3.37 / 14.07 8.41 4200 680 / 4350 3700 750 / 4250 2.85 3.6 2.65 6.1 - A++ 4 - A+ 4x1 KUE-125 DVR13 4000 63 70 946 / 810 / 410 71 220-240/1/50 (2+T)x4 KPC-140 DR14 1600 / 1850 / 2200 46 / 50 / 53 67 1650 / 235 / 675 41.7 With communication With communication R-32 2.8 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 KPCA-140 DVR15 14.07 3.52 / 15.83 16.12 4.10 / 17.30 9.91 5000 810 / 6350 4750 910 / 6050 2.83 3.07 2.65 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DVR14 5600 64 73 990 / 975 / 375 82.0 220-240/1/50 (4+T)x2,5 KPC-140 DR14 1600 / 1850 / 2200 46 / 50 / 53 67 1650 / 235 / 675 41.7 With communication With communication R-32 2.4 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. Ducts KCT-04.1 SPSWF Standard R-32 DRAINAGE REFRIGERANT PUMP HERTZ COMPATIBLE SMART HOME WITH AIRZONE ON/OFF CONTACT FRESH AIR SUPPLY FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132 Set Model Set Cooling capacity rated kW Cooling capacity min. / max. kW Heating capacity rated kW Heating capacity min. / max. kW Cooling input rated W Cooling input min. / max. W Heating input rated W Heating input min. / max. W EER COP SEER SCOP Shielded communication wiring mm² Outdoor unit Air flow m³/h Sound pressure Sound power level dB(A) dB(A) Width / Height / Depth mm Net weight kg Power supply V/ph/Hz Power wiring mm² Indoor unit Air flow low / medium / high m³/h Sound pressure low / medium / high dB(A) Sound power level dB(A) Max. pressure available Pa Width / Height / Depth mm Net weight kg Possibility of vertical installation Refrigerant Type refrigerant Refrigerant charge kg Liquid / Gas pipe diameter inch Piping total length m Vertical piping max. length m Working range Outdoor ambient temperature for cooling min. / max. °C Outdoor ambient temperature for heating min. / max. °C KPDA-26 DVR15 2.63 0,35 / 3,07 3,07 0,90 / 3,51 800 145 / 1100 1000 300 / 1300 3.29 3.07 6.3 - A++ 4.1 - A+ 4x1 KUE-26 DVR14 2000 54 61 765 / 555 / 303 24.6 220-240/1/50 (2+T)x2,5 KPD-26 DR15 300 / 480 / 600 29 / 31 / 34 55 80 700 / 200 / 506 18 No R-32 0.65 1/4" / 3/8" 25 10 -15 / 50 -15 / 24 KPDA-35 DVR15 3.52 0,52 / 3,99 3,81 0,99 / 4,39 1080 155 / 1373 1038 302 / 1390 3.26 3.67 6.3 - A++ 4.1 - A+ 4x1 KUE-35 DVR13 2000 54 61 765 / 555 / 303 26.6 220-240/1/50 (2+T)x2,5 KPD-35 DR15 300 / 480 / 600 30 / 32 / 34 56 100 700 / 200 / 506 18 No R-32 0.71 1/4" / 3/8" 25 10 -15 / 50 -15 / 24 KPDA-52 DVR15 5.28 1,31 / 6,15 6,01 1,49 / 6,30 1590 360 / 2130 1615 500 / 1850 3.32 3.72 6.5 - A++ 4.1 - A+ 4x1 KUE-52 DVR13 2100 59 62 805 / 555 / 330 32.5 220-240/1/50 (2+T)x2,5 KPD-52 DR15 600 / 780 / 900 34 / 31 / 36.5 53 160 700 / 245 / 750 24.4 Yes R-32 1.15 1/4" / 1/2" 30 20 -15 / 50 -15 / 24 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. KCT-04.1 SPSWF Standard R-32 DRAINAGE REFRIGERANT PUMP HERTZ COMPATIBLE SMART HOME WITH AIRZONE ON/OFF CONTACT FRESH AIR SUPPLY Set Model Set Cooling capacity rated kW Cooling capacity min. / max. kW Heating capacity rated kW Heating capacity min. / max. kW Cooling input rated W Cooling input min. / max. W Heating input rated W Heating input min. / max. W EER COP SEER SCOP Shielded communication wiring mm² Outdoor unit Air flow Sound pressure m³/h dB(A) Sound power level dB(A) Width / Height / Depth mm Net weight kg Power supply Power wiring V/ph/Hz mm² Indoor unit Air flow low / medium / high m³/h Sound pressure low / medium / high dB(A) Sound power level Max. pressure available dB(A) Pa Width / Height / Depth mm Net weight kg Possibility of vertical installation Refrigerant Type refrigerant Refrigerant charge kg Liquid / Gas pipe diameter inch Piping total length m Vertical piping max. length m Working range Outdoor ambient temperature for cooling min. / max. °C Outdoor ambient temperature for heating min. / max. °C KPDA-71 DVR15 7.03 3,22 / 7,91 7,62 2,78 / 8,56 2280 750 / 2860 2000 640 / 2500 3.08 3.81 6.5 - A++ 4.2 - A+ 4x1 KUE-71 DVR14 3500 60 69 890 / 673 / 342 41.9 220-240/1/50 (2+T)x2,5 KPD-71 DR15 700 / 1000 / 1200 31 / 32.5 / 33.5 56 160 1000 / 245 / 750 31.8 Yes R-32 1.4 3/8" / 5/8" 50 25 -15 / 50 -15 / 24 KPDA-90 DVR15 8.79 2,22 / 9,50 9,38 2,69 / 9,79 2800 190 / 3400 2400 430 / 2600 3.14 3.91 6.3 - A++ 4.1 - A+ 4x1 KUE-90 DVR14 3800 63 70 946 / 810 / 410 51 220-240/1/50 (2+T)x2,5 KPD-90 DR15 900 / 1200 / 1500 35 / 37 / 39 58 160 1000 / 245 / 750 32.7 Yes R-32 1.8 3/8" / 5/8" 50 25 -15 / 50 -15 / 24 KPDA-105 DVR15 10.55 2,75 / 11,14 11,73 2,78 / 12,78 3950 900 / 4150 3250 800 / 3950 2.67 3.61 6.2 - A++ 4.1 - A+ 4x1 KUE-105 DVR13 4000 63 70 946 / 810 / 410 66.9 220-240/1/50 (2+T)x4 KPD-105 DR15 1100 / 1300 / 1600 33 / 36 / 38 60 160 1200 / 245 / 750 38.4 Yes R-32 2.4 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 KPDA-105 DTR15 10.55 2,75 / 11,14 11,73 2,78 / 12,84 4000 890 / 4200 3250 780 / 4000 2.64 3.61 6.1 - A++ 4.1 - A+ 4x1 KUE-105 DTR13 4000 63 70 946 / 810 / 410 80.5 380-415/3/50 (4+T)x2,5 KPD-105 DR15 1100 / 1300 / 1600 34 / 37 / 40 60 160 1200 / 245 / 750 38.4 Yes R-32 2.4 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. KCT-04.1 SPSWF Standard Set Model Set Cooling capacity rated kW Cooling capacity min. / max. kW Heating capacity rated kW Heating capacity min. / max. kW Cooling input rated W Cooling input min. / max. W Heating input rated W Heating input min. / max. W EER COP SEER SCOP Shielded communication wiring mm² Outdoor unit Air flow Sound pressure m³/h dB(A) Sound power level dB(A) Width / Height / Depth mm Net weight kg Power supply Power wiring V/ph/Hz mm² Indoor unit Air flow low / medium / high m³/h Sound pressure low / medium / high dB(A) Sound power level Max. pressure available dB(A) Pa Width / Height / Depth mm Net weight kg Possibility of vertical installation Refrigerant Type refrigerant Refrigerant charge kg Liquid / Gas pipe diameter inch Piping total length m Vertical piping max. length m Working range Outdoor ambient temperature for cooling min. / max. °C Outdoor ambient temperature for heating min. / max. °C KPDA-125 DVR15 12.02 2,93 / 12,31 13,48 3,37 / 14,07 4200 680 / 4500 3450 750 / 4100 2.86 3.91 6.1 - A++ 4.0 - A+ 4x1 KUE-125 DVR13 4000 63 73 946 / 810 / 410 71.0 220-240/1/50 (2+T)x4 KPD-125 DR15 1300 / 1700 / 2000 36 / 37.5 / 39 65 160 1200 / 245 / 750 40.4 Yes R-32 2.8 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 KPDA-140 DTR15 14.07 3,51 / 15,83 16,12 4,10 / 17,59 4800 810 / 6450 4600 950 / 5800 2.93 3.50 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DTR14 5600 64.5 73 990 / 975 / 375 90.0 380-415/3/50 (4+T)x2,5 KPD-140 DR15 1300 / 1700 / 2000 40 / 42 / 44 65 200 1200 / 245 / 750 40.4 Yes R-32 2.9 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132 KPDA-140 DVR15 14.07 3,51 / 15,83 16,12 4,10 / 17,59 4800 810 / 6450 4600 950 / 5800 2.93 3.50 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DVR14 5600 64.5 73 990 / 975 / 375 82.0 220-240/1/50 (2+T)x4 KPD-140 DR15 1300 / 1700 / 2000 40 / 42 / 44 65 200 1200 / 245 / 750 40.4 Yes R-32 2.9 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 KPDA-160 DTR15 15.24 4,10 / 17,30 17,59 4,39 / 20,52 5250 1030 / 6650 5150 950 / 6600 2.90 3.42 6.1 - A++ 4.0 - A+ 4x1 KUE-160 DTR14 5600 65 74 990 / 975 / 375 92.0 380-415/3/50 (4+T)x2,5 KPD-160 DR15 1500 / 1900 / 2200 41.5 / 43 / 44.5 66 200 1200 / 300 / 750 47.4 Yes R-32 3.2 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. Floor Standing R-32 DC INVERTER DC INVERTER SMART HOME REFRIGERANT COMPRESSOR EXTERNAL FAN ON/OFF CONTACT SOUND LEVEL REDUCTION POSSIBILITY Set Model Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP SEER SCOP Shielded communication wiring Outdoor unit Air flow Sound pressure Width / Height / Depth Net weight Power supply Power wiring Indoor unit Air flow low / medium / high Sound pressure Sound power level Width / Height / Depth Net weight Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length kW kW kW kW W W W W mm² m³/h dB(A) mm kg V/ph/Hz mm² m³/h dB(A) dB(A) mm kg kg inch m m KPVA-160 DTR14 15,25 4,11 / 16,13 18,18 4,40 / 18,77 6000 1000 / 7200 5600 1020 / 7200 2.54 3.24 5.8 4.0 - A+ 4x1 KUE-160 DTR14 5600 65 980 / 975 / 375 92 380-415/3/50 (4+T)x4 KPV-160 DR14 1600 / 1750 / 1950 40 / / 45.5 / 50.5 / / 53 / 64 600 / 1934 / 455 61.4 R-32 3.2 3/8" / 5/8" 75 30 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. Twin Cassette 840x840 KCT-04.1 SPSWF Standard KCMI 112 Branch pipe R-32 DRAINAGE REFRIGERANT PUMP HERTZ COMPATIBLE SMART HOME WITH AIRZONE ON/OFF CONTACT AIR INTAKE FRESH AIR SUPPLY Set model Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP SEER SCOP Shielded communication wiring Outdoor unit Air flow Sound pressure Sound power level Width / Height / Depth Net weight Power supply Power wiring Indoor unit Air flow low / medium / high Sound pressure low / medium / high Sound power level Width / Height / Depth Net weight Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length Working range Outdoor ambient temperature for cooling min. / max. Outdoor ambient temperature for heating min. / max. kW kW kW kW W W W W mm² m³/h dB(A) dB(A) mm kg V/ph/Hz mm² m³/h dB(A) dB(A) mm kg kg inch m m °C °C KCISA-71 DVR15 TWIN 14.07 3,51 / 15,83 16,12 4,10 / 17,59 4800 810 / 6450 4600 950 / 5800 2.93 3.50 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DVR14 5600 64.5 73 990 / 975 / 375 82.0 220-240/1/50 (4+T)x2,5 2x KCIS-71 DR14 1600 / 1750 / 1900 48 / 50.5 / 52.5 66 830 / 287 / 830 29.3 R-32 2.9 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132 KCISA-71 DTR15 TWIN 14.07 3,51 / 15,83 16,12 4,10 / 17,59 4800 810 / 6450 4600 950 / 5800 2.93 3.50 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DTR14 5600 64.5 73 990 / 975 / 375 90.0 380-415/3/50 (4+T)x2,5 2x KCIS-71 DR14 1600 / 1750 / 1900 48 / 50.5 / 52.5 66 830 / 287 / 830 29.3 R-32 2.9 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 KCISA-90 DTR15 TWIN 15.24 4,10 / 17,30 17,59 4,39 / 20,52 5250 1030 / 6650 5150 950 / 6600 2.90 3.42 6.1 - A++ 4.0 - A+ 4x1 KUE-160 DTR14 5600 65 74 990 / 975 / 375 92.0 380-415/3/50 (4+T)x2,5 2x KCIS-90 DR14 1650 / 1850 / 2000 49.5 / 52 / 54.5 66 830 / 287 / 830 29.3 R-32 3.2 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. Twin Floor/Ceiling KID-06 S Standard KCMI 112 Branch pipe R-32 DRAINAGE REFRIGERANT PUMP HERTZ COMPATIBLE SMART HOME WITH AIRZONE ON/OFF CONTACT AIR INTAKE FRESH AIR SUPPLY FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132 Set model Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP COP at -7°C SEER SCOP Shielded communication wiring Outdoor unit Air flow Sound pressure Sound power level Width / Height / Depth Net weight Power supply Power wiring Indoor unit Air flow low / medium / high Sound pressure low / medium / high Sound power level Width / Height / Depth Net weight Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length Working range Outdoor ambient temperature for cooling min. / max. Outdoor ambient temperature for heating min. / max. kW kW kW kW W W W W mm² m³/h dB(A) dB(A) mm kg V/ph/Hz mm² m³/h dB(A) dB(A) mm kg kg inch m m °C °C KPCA-52 DTR14 TWIN 2x 5,28 2.71 / 5.86 2x 5,57 2.42 / 6.3 1450 670 / 2027 1500 540 / 1640 3.61 2.6 6.1 - A++ 4 - A+ 4x1 KUE-105 DTR13 4000 63 70 946 / 810 / 410 66.90 380-415/3/50 (4+T)x2,5 2x KPC-52 DR14 723 / 839 / 958 37 / 41 / 44 59 1068 / 235 / 675 28 R-32 2.4 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 KPCA-52 DVR14 TWIN 2x 5,28 2.71 / 5.86 2x 5,57 2.42 / 6.3 1450 670 / 2027 1500 540 / 1640 3.71 2.6 6.1 - A++ 4 - A+ 4x1 KUE-105 DVR13 3800 62 70 946 / 810 / 410 52.8 220-240/1/50 (2+T)x4 2x KPC-52 DR14 723 / 839 / 958 37 / 41 / 44 59 1068 / 235 / 675 28 R-32 2.4 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 KPCA-71 DVR15 TWIN 14.07 3,51 / 15,83 16,12 4,10 / 17,59 4800 810 / 6450 4600 950 / 5800 2.93 3.50 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DVR14 5600 64.5 73 990 / 975 / 375 82.0 220-240/1/50 (4+T)x2,5 2x KPC-71 DR14 853 / 1023 / 1192 43 / 47 / 51 55 1068 / 235 / 675 28 R-32 2.9 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 KPCA-71 DTR15 TWIN 14.07 3,51 / 15,83 16,12 4,10 / 17,59 4800 810 / 6450 4600 950 / 5800 2.93 3.50 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DTR14 5600 64.5 73 990 / 975 / 375 90.0 380-415/3/50 (4+T)x2,5 2x KPC-71 DR14 853 / 1023 / 1192 43 / 47 / 51 55 1068 / 235 / 675 28 R-32 2.9 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. *In these models it is possible to combine horizontal and vertical units. If you require the vertical, request the reference with the V. Twin Duct Set model Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP SEER SCOP Shielded communication wiring Outdoor unit Air flow Sound pressure Sound power level Width / Height / Depth Net weight Power supply Power wiring Indoor unit Air flow low / medium / high Sound pressure low / medium / high Sound power level Max. pressure available Width / Height / Depth Net weight Possibility of vertical installation Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length Working range Outdoor ambient temperature for cooling min. / max. Outdoor ambient temperature for heating min. / max. kW kW kW kW W W W W mm² m³/h dB(A) dB(A) mm kg V/ph/Hz mm² m³/h dB(A) dB(A) Pa mm kg kg inch m m °C °C KPDA-35 DVR15 TWIN 7.03 3,22 / 7,91 7,62 2,78 / 8,56 2280 750 / 2860 2000 640 / 2500 3.08 3.81 6.5 - A++ 4.2 - A+ 4x1 KUE-71 DVR14 3500 60 69 890 / 673 / 342 41.9 220-240/1/50 (2+T)x2,5 2x KPD-35 DR15 300 / 480 / 600 30 / 32 / 34 56 100 700 / 200 / 506 18 No R-32 1.4 3/8" / 5/8" 50 25 -15 / 50 -15 / 24 FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132 KPDA-52 DTR15 TWIN 10.55 2.75 / 11.14 11.72 2.78 / 12.78 3950 900 / 4150 3250 800 / 3950 2.6 3.71 6.1 - A++ 4.0 - A+ 4x1 KUE-105 DTR13 4000 63 70 946 / 810 / 410 80.5 380-415/3/50 (4+T)x2,5 2x KPD-52 DR15 600 / 780 / 900 34 / 31 / 36.5 53 160 700 / 245 / 750 24.4 Yes R-32 2.4 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 KPDA-52 DVR15 TWIN 10.55 2.73 / 11.78 11.72 2.78 / 12.84 4000 890 / 4200 3250 780 / 4000 2.7 3.71 6.1 - A++ 4.0 - A+ 4x1 KUE-105 DVR13 4000 63 70 946 / 810 / 410 66.9 220-240/1/50 (2+T)x4 2x KPD-52 DR15 600 / 780 / 900 34 / 31 / 36.5 53 160 700 / 245 / 750 24.4 Yes R-32 2.4 3/8" / 5/8" 75 30 -15 / 50 -15 / 24 Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. *In these models it is possible to combine horizontal and vertical units. If you require the vertical, request the reference with the V. MAIN OFFICE Blasco de Garay, 4-6 08960 Sant Just Desvern (Barcelona) Phone: +34 93 480 33 22 www.frigicoll.es www.kaysun.es