Instructions for Kaysun models including: KCIA-26 DVR15 Commercial Range, KCIA-26 DVR15, Commercial Range, Range

Folleto zen

[PDF] COMMERCIAL RANGE - Kaysunwww.kaysun.es › uploads › 2024/05

[PDF] COMMERCIAL RANGE - Kaysun

The Kaysun R-32 commercial range includes axial outdoor units, in ... KCI-26 DR15. KCI-35 DR15. KCI-52 DR15. Air flow low / medium / high m³/h. 330 ...


File Info : application/pdf, 14 Pages, 38.35MB

PDF preview unavailable. Download the PDF instead.

Flyer-Zen-2024-EN
ZEN
COCMOMMMEERCRIALCRIAANGLE RANGE
The Kaysun R-32 commercial range includes axial outdoor units, in addition to several types of indoor units. The Kaysun outdoor units are compact, robust machines that require little space for installation. They can be used with

Full DC Inverter
The exclusive Kaysun GENIUS CORE algorithm provides the system with complete stability. Using the Alpha chip, the compressor, PWM module and DC motors in the unit work in an optimum way, adapting to the real demand and preventing losses of energy. The dynamic adjustment of the electrical power guarantees constant equilibrium for the system, meaning the Kaysun
when operating for long periods.

i-Balance Opreation

WiFi
It is possible to control Kaysun units via a tablet or smartphone as an option. The units can be managed remotely and they even have a weekly programmer.

Twins
Within the range it is possible to install TWIN-type units, meaning the installation of two indoor units which provide greater distribution of air while improving climate control, in conjunction with a single outdoor unit.

CASSETTE (600x600)

KID-06 S Standard

R-32

DRAINAGE

REFRIGERANT

PUMP

HERTZ

COMPATIBLE SMART HOME WITH AIRZONE

ON/OFF CONTACT

FRESH AIR SUPPLY

Set Model
Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP SEER SCOP Shielded communication wiring
Outdoor unit Air flow Sound pressure Sound power level Width / Height / Depth Net weight Power supply Power wiring
Indoor unit Air flow low / medium / high Sound pressure Sound power level Width / Height / Depth Net weight Power supply Panel; Model Panel; Width / Height / Depth Panel; Net weight
Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length
Working range Outdoor ambient temperature for cooling min. / max. Outdoor ambient temperature for heating min. / max.

kW kW kW kW W W W W
mm²
m³/h dB(A) dB(A) mm kg V/ph/Hz mm²
m³/h dB(A) dB(A) mm kg V/ph/Hz
mm kg
kg inch m m
°C °C

KCIA-26 DVR15
2.63 0.35 / 3.07
3,07 0.90 / 3.51
800 145 / 1100
1000 300 / 1300
3.29 3.07 6.3 - A++ 4.1 - A+ 4x1 KUE-26 DVR14 2000 54
765 / 555 / 303 24.6
220-240/1/50 (2+T)x2,5
KCI-26 DR15 330 / 520 / 620 25.5 / / 31.5 / 38.5 / / 42 /
55 570 / 245 / 570
16.2 With communication KPA-03B 600x600
620 / 50 / 620 2.7
R-32 0.65 1/4" / 3/8" 25 10
-15 / 50 -15 / 24 Provisional data

FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132

KCIA-35 DVR15
3.52 0.85 / 4.16
3.81 0.47 / 4.34
1015 160 / 1450
1020 125 / 1390
3.47 3.73 6.8 - A++ 4.1 - A+ 4x1 KUE-35 DVR13 2000 54 61 765 / 555 / 303 24.6 220-240/1/50 (2+T)x2,5 KCI-35 DR15 330 / 520 / 620 25.5 / / 31.5 / 38.5 / / 42 / 55 570 / 245 / 570 16.2 With communication KPA-03B 600x600 620 / 50 / 620 2.7
R-32 0.71 1/4" / 3/8" 25 10
-15 / 50 -15 / 24

KCIA-52 DVR15
5.28 2.9 / 5.59
5.57 2.37 / 6.1
1550 720 / 2040
1560 700 / 1950
3.41 3.57 6.5 - A++ 4.1 - A+ 4x1 KUE-52 DVR13 2100 56 62 805 / 555 / 330 32.5 220-240/1/50 (2+T)x2,5 KCI-52 DR15 300 / 540 / 660 25 / / 31.5 / 41 / / 44 / 59 570 / 245 / 570 16.2 With communication KPA-03B 600x600 / /
R-32 1.15 1/4" / 1/2" 30 20
-15 / 50 -15 / 24

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted.

CASSETTE (840x840)

KID-06 S Standard

R-32 REFRIGERANT

HERTZ

COMPATIBLE SMART HOME WITH AIRZONE

ON/OFF CONTACT

FOLLOW ME

FRESH AIR SUPPLY

Set model
Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Heating capacity rated at -7°C Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP COP at -7°C SEER SCOP Shielded communication wiring
Outdoor unit Air flow Sound pressure Sound power level Width / Height / Depth Net weight Power supply Power wiring
Indoor unit Air flow low / medium / high Sound pressure low / medium / high Sound power level Width / Height / Depth Net weight Power supply Power wiring Panel; Model Panel; Width / Height / Depth Panel; Net weight
Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length
Working range Outdoor ambient temperature for cooling min. / max. Outdoor ambient temperature for heating min. / max.

kW kW kW kW kW W W W W
mm²
m³/h dB(A) dB(A) mm kg V/ph/Hz mm²
m³/h dB(A) dB(A) mm kg V/ph/Hz mm²
mm kg
kg inch m m
°C °C

KCISA-71 DVR15
7.03 3.3 / 7.91
7.52 2.79 / 8.50
3.31 2320 780 / 2750 1900 610 / 2300 2.88 4.10 2.65 6.3 - A++ 4.1 - A+ 4x1 KUE-71 DVR14 3500 60 68 890 / 673 / 342 41.9 220-240/1/50 (2+T)x2,5 KCIS-71 DR14 992 / 1118 / 1247 42 / 47.5 / 50
59 830 / 205 / 830
21.6 With communication With communication LCAC KPA4-04B 840x840
950 / 55 / 950 6
R-32 1.9 3/8" / 5/8" 50 25
-15 / 50 -15 / 24

KCISA-90 DVR15
8.79 2.23 / 9.38
9.38 2.7 / 9.73
6.55 2750 190 / 3000 2450 430 / 2550 3.2
4 2.55 6.6 - A++ 4.2 - A+ 4x1 KUE-90 DVR14 3800 62 70 946 / 810 / 410 51 220-240/1/50 (2+T)x2,5 KCIS-90 DR14 1300 / 1530 / 1700 46 / 48 / 50.5 63 830 / 245 / 830 24.6 With communication With communication LCAC KPA4-04B 840x840 950 / 55 / 950
6
R-32 2
3/8" / 5/8" 50 25
-15 / 50 -15 / 24

KCISA-105 DVR14
10.55 2.7 / 11.43
11.14 2.78 / 12.66
7.52 4000 890 / 4150 3000 780 / 4000 2.65 3.68 2.6 6.1 - A++ 4 - A+ 4x1 KUE-105 DVR13 4000
63 70 946 / 810 / 410 66.900 220-240/1/50 (2+T)x4 KCIS-105 DR14 1300 / 1530 / 1700 46 / 49 / 51 64 830 / 245 / 830 27.2 With communication With communication LCAC KPA4-04B 840x840 950 / 55 / 950 6
R-32 2.4 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted.

KID-06 S Standard

Set model
Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Heating capacity rated at -7°C Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP COP at -7°C SEER SCOP Shielded communication wiring
Outdoor unit Air flow Sound pressure Sound power level Width / Height / Depth Net weight Power supply Power wiring
Indoor unit Air flow low / medium / high Sound pressure low / medium / high Sound power level Width / Height / Depth Net weight Power supply Power wiring Panel; Model Panel; Width / Height / Depth Panel; Net weight
Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length
Working range Outdoor ambient temperature for cooling min. / max. Outdoor ambient temperature for heating min. / max.

kW kW kW kW kW W W W W
mm²
m³/h dB(A) dB(A) mm kg V/ph/Hz mm²
m³/h dB(A) dB(A) mm kg V/ph/Hz mm²
mm kg
kg inch m m
°C °C

KCISA-140 DTR15
14.07 3.52 / 15.83
16.12 4.20 / 17.29
9.74 4980 810 / 6350 4580 900 / 5500 3.03 3.5 2.68 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DTR14 5600
64 73 990 / 975 / 375 90.0 380-415/3/50 (4+T)x2,5 KCIS-140 DR14 1600 / 1750 / 1900 48 / 50.5 / 52.5 66 830 / 287 / 830 29.3 With communication With communication LCAC KPA4-04B 840x840 950 / 55 / 950 6
R-32 2.9 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132
KCISA-160 DTR15
15.24 4.10 / 16.12
18.17 4.40 / 19.05
10.53 5700 1000 / 6250 5700 1020 / 6350 2.95 3.22 2.59 6.1 - A++ 4.0 - A+ 4x1 KUE-160 DTR14 5600
65 75 990 / 975 / 375 92.0 380-415/3/50 (4+T)x2,5 KCIS-160 DR14 1650 / 1850 / 2000 49.5 / 52 / 54.5 66 830 / 287 / 830 29.3 With communication With communication LCAC KPA4-04B 840x840 950 / 55 / 950 6
R-32 3
3/8" / 5/8" 75 30
-15 / 50 -15 / 24

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted.

KID-06 S Standard

FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132

Set model

Set

Cooling capacity rated

kW

Cooling capacity min. / max.

kW

Heating capacity rated

kW

Heating capacity min. / max.

kW

Heating capacity rated at -7°C

kW

Cooling input rated

W

Cooling input min. / max.

W

Heating input rated

W

Heating input min. / max.

W

EER

COP

COP at -7°C

SEER

SCOP

Shielded communication wiring

mm²

Outdoor unit

Air flow

m³/h

Sound pressure

dB(A)

Sound power level

dB(A)

Width / Height / Depth

mm

Net weight

kg

Power supply

V/ph/Hz

Power wiring

mm²

Indoor unit Air flow low / medium / high

m³/h

Sound pressure low / medium / high

dB(A)

Sound power level

dB(A)

Width / Height / Depth

mm

Net weight

kg

Power supply

V/ph/Hz

Power wiring

mm²

Refrigerant Type refrigerant

Refrigerant charge

kg

Liquid / Gas pipe diameter

inch

Piping total length

m

Vertical piping max. length

m

Working range Outdoor ambient temperature for cooling min. / max. °C

Outdoor ambient temperature for heating min. / max. °C

KPCA-140 DTR15
14.07 3.52 / 15.24
16.12 4.10 / 17.59
9.91 5000 910 / 6200 4800 950 / 5950 2.83 3.07 2.65 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DTR14 5600
64 73 990 / 975 / 375 90.0 380-415/3/50 (4+T)x2,5 KPC-140 DR14 1600 / 1850 / 2200 46 / 50 / 53 67 1650 / 235 / 675 41.7 With communication With communication
R-32 2.4 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

KPCA-160 DTR15
15.24 4.10 / 16.12
18.17 4.40 / 19.35
10.53 5900 1100 / 6500 5950 1120 / 6350 2.76
3 2.6 6.1 - A++ 4.0 - A+ 4x1 KUE-160 DTR14 5600 65 75 990 / 975 / 375 92.0 380-415/3/50 (4+T)x4 KPC-160 DR14 1650 / 1950 / 48 / 52 / 55 67 1650 / 235 / 675 42.3 With communication With communication
R-32 2.8 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted.

Floor/Ceiling

KID-06 S Standard

R-32

DC INVERTER DC INVERTER

REFRIGERANT COMPRESSOR EXTERNAL FAN

HERTZ

COMPATIBLE SMART HOME WITH AIRZONE

ON/OFF CONTACT

FOLLOW ME

FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132

Set model

Set

Cooling capacity rated

kW

Cooling capacity min. / max.

kW

Heating capacity rated

kW

Heating capacity min. / max.

kW

Heating capacity rated at -7°C

kW

Cooling input rated

W

Cooling input min. / max.

W

Heating input rated

W

Heating input min. / max.

W

EER

COP

COP at -7°C

SEER

SCOP

Shielded communication wiring

mm²

Outdoor unit

Air flow

m³/h

Sound pressure

dB(A)

Sound power level

dB(A)

Width / Height / Depth

mm

Net weight

kg

Power supply

V/ph/Hz

Power wiring

mm²

Indoor unit Air flow low / medium / high

m³/h

Sound pressure low / medium / high

dB(A)

Sound power level

dB(A)

Width / Height / Depth

mm

Net weight

kg

Power supply

V/ph/Hz

Power wiring

mm²

Refrigerant Type refrigerant

Refrigerant charge

kg

Liquid / Gas pipe diameter

inch

Piping total length

m

Vertical piping max. length

m

Working range Outdoor ambient temperature for cooling min. / max. °C

Outdoor ambient temperature for heating min. / max. °C

KPCA-52 DVR14
5.28 2.71 / 5.86
5.57 2.42 / 6.3
3.54 1450 670 / 2027 1500 540 / 1640 3.7 3.75 2.88 6.1 - A++ 4 - A+ 4x1 KUE-52 DVR13 2100 56 65 805 / 555 / 330 32.5 220-240/1/50 (2+T)x1,5 KPC-52 DR14 723 / 839 / 958 37 / 41 / 44 59 1068 / 235 / 675 28 With communication With communication
R-32 1.15 1/4" / 1/2" 30 20
-15 / 50 -15 / 24

KPCA-71 DVR15
7.03 3.22 / 7.95
7.62 2.72 / 8.50
4.87 2300 750 / 2730 1980 650 / 2940 2.95
4 2.72 6.1 - A++ 4.1 - A+ 4x1 KUE-71 DVR14 3500 60 68 890 / 673 / 342 41.9 220-240/1/50 (2+T)x2,5 KPC-71 DR14 853 / 1023 / 1192 43 / 47 / 51 55 1068 / 235 / 675 28 With communication With communication
R-32 1.5 3/8" / 5/8" 50 25
-15 / 50 -15 / 24

KPCA-105 DVR14
10.55 2.73 / 11.78
11.72 2.81 / 12.78
7.61 4000 890 / 4300 3350 780 / 3950 2.6 3.6
2.5 6.1 - A++
4 - A+ 4x1
KUE-105 DVR13 3800 62 70
946 / 810 / 410 52.8
220-240/1/50 (2+T)x4
KPC-105 DR14 1504 / 1728 / 1955
45 / 47.5 / 51 65
1650 / 235 / 675 41.5
With communication With communication
R-32 2
3/8" / 5/8" 50 25
-15 / 50 -15 / 24

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted.

KID-06 S Standard

R-32

DC INVERTER DC INVERTER

REFRIGERANT COMPRESSOR EXTERNAL FAN

HERTZ

COMPATIBLE SMART HOME WITH AIRZONE

ON/OFF CONTACT

FOLLOW ME

FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132

Set model

Set

Cooling capacity rated

kW

Cooling capacity min. / max.

kW

Heating capacity rated

kW

Heating capacity min. / max.

kW

Heating capacity rated at -7°C

kW

Cooling input rated

W

Cooling input min. / max.

W

Heating input rated

W

Heating input min. / max.

W

EER

COP

COP at -7°C

SEER

SCOP

Shielded communication wiring

mm²

Outdoor unit

Air flow

m³/h

Sound pressure

dB(A)

Sound power level

dB(A)

Width / Height / Depth

mm

Net weight

kg

Power supply

V/ph/Hz

Power wiring

mm²

Indoor unit Air flow low / medium / high

m³/h

Sound pressure low / medium / high

dB(A)

Sound power level

dB(A)

Width / Height / Depth

mm

Net weight

kg

Power supply

V/ph/Hz

Power wiring

mm²

Refrigerant Type refrigerant

Refrigerant charge

kg

Liquid / Gas pipe diameter

inch

Piping total length

m

Vertical piping max. length

m

Working range Outdoor ambient temperature for cooling min. / max. °C

Outdoor ambient temperature for heating min. / max. °C

KPCA-105 DTR14
10.55 2.73 / 11.43
11.72 2.78 / 12.78
7.61 3900 900 / 4250 3350 800 / 3950 2.6 3.6 2.5 6.1 - A++ 4 - A+ 4x1 KUE-105 DTR13 4000
63 70 946 / 810 / 410 66.90 380-415/3/50 (4+T)x2,5 KPC-105 DR14 1504 / 1728 / 2100 45 / 48 / 51.5 65 1650 / 235 / 675 41.5 With communication With communication
R-32 2.4 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

KPCA-125 DVR14
12.02 2.93 / 12.31
13.48 3.37 / 14.07
8.41 4200 680 / 4350 3700 750 / 4250 2.85 3.6 2.65 6.1 - A++ 4 - A+ 4x1 KUE-125 DVR13 4000
63 70 946 / 810 / 410 71 220-240/1/50 (2+T)x4 KPC-140 DR14 1600 / 1850 / 2200 46 / 50 / 53 67 1650 / 235 / 675 41.7 With communication With communication
R-32 2.8 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

KPCA-140 DVR15
14.07 3.52 / 15.83
16.12 4.10 / 17.30
9.91 5000 810 / 6350 4750 910 / 6050 2.83 3.07 2.65 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DVR14 5600
64 73 990 / 975 / 375 82.0 220-240/1/50 (4+T)x2,5 KPC-140 DR14 1600 / 1850 / 2200 46 / 50 / 53 67 1650 / 235 / 675 41.7 With communication With communication
R-32 2.4 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted.

Ducts

KCT-04.1 SPSWF Standard

R-32

DRAINAGE

REFRIGERANT

PUMP

HERTZ

COMPATIBLE SMART HOME WITH AIRZONE

ON/OFF CONTACT

FRESH AIR SUPPLY

FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132

Set Model

Set

Cooling capacity rated

kW

Cooling capacity min. / max.

kW

Heating capacity rated

kW

Heating capacity min. / max.

kW

Cooling input rated

W

Cooling input min. / max.

W

Heating input rated

W

Heating input min. / max.

W

EER

COP

SEER SCOP

Shielded communication wiring

mm²

Outdoor unit Air flow

m³/h

Sound pressure Sound power level

dB(A) dB(A)

Width / Height / Depth

mm

Net weight

kg

Power supply

V/ph/Hz

Power wiring

mm²

Indoor unit Air flow low / medium / high

m³/h

Sound pressure low / medium / high

dB(A)

Sound power level

dB(A)

Max. pressure available

Pa

Width / Height / Depth

mm

Net weight

kg

Possibility of vertical installation

Refrigerant Type refrigerant

Refrigerant charge

kg

Liquid / Gas pipe diameter

inch

Piping total length

m

Vertical piping max. length

m

Working range Outdoor ambient temperature for cooling min. / max. °C

Outdoor ambient temperature for heating min. / max. °C

KPDA-26 DVR15
2.63 0,35 / 3,07
3,07 0,90 / 3,51
800 145 / 1100
1000 300 / 1300
3.29 3.07 6.3 - A++ 4.1 - A+ 4x1 KUE-26 DVR14 2000 54 61 765 / 555 / 303 24.6 220-240/1/50 (2+T)x2,5 KPD-26 DR15 300 / 480 / 600 29 / 31 / 34 55 80 700 / 200 / 506 18 No
R-32 0.65 1/4" / 3/8" 25 10
-15 / 50 -15 / 24

KPDA-35 DVR15
3.52 0,52 / 3,99
3,81 0,99 / 4,39
1080 155 / 1373
1038 302 / 1390
3.26 3.67 6.3 - A++ 4.1 - A+ 4x1 KUE-35 DVR13 2000 54 61 765 / 555 / 303 26.6 220-240/1/50 (2+T)x2,5 KPD-35 DR15 300 / 480 / 600 30 / 32 / 34 56 100 700 / 200 / 506 18 No
R-32 0.71 1/4" / 3/8" 25 10
-15 / 50 -15 / 24

KPDA-52 DVR15
5.28 1,31 / 6,15
6,01 1,49 / 6,30
1590 360 / 2130
1615 500 / 1850
3.32 3.72 6.5 - A++ 4.1 - A+ 4x1 KUE-52 DVR13 2100 59 62 805 / 555 / 330 32.5 220-240/1/50 (2+T)x2,5 KPD-52 DR15 600 / 780 / 900 34 / 31 / 36.5 53 160 700 / 245 / 750 24.4 Yes
R-32 1.15 1/4" / 1/2" 30 20
-15 / 50 -15 / 24

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted.

KCT-04.1 SPSWF Standard

R-32

DRAINAGE

REFRIGERANT

PUMP

HERTZ

COMPATIBLE SMART HOME WITH AIRZONE

ON/OFF CONTACT

FRESH AIR SUPPLY

Set Model

Set

Cooling capacity rated

kW

Cooling capacity min. / max.

kW

Heating capacity rated

kW

Heating capacity min. / max.

kW

Cooling input rated

W

Cooling input min. / max.

W

Heating input rated

W

Heating input min. / max.

W

EER

COP SEER

SCOP

Shielded communication wiring

mm²

Outdoor unit Air flow Sound pressure

m³/h dB(A)

Sound power level

dB(A)

Width / Height / Depth

mm

Net weight

kg

Power supply Power wiring

V/ph/Hz mm²

Indoor unit Air flow low / medium / high

m³/h

Sound pressure low / medium / high

dB(A)

Sound power level Max. pressure available

dB(A) Pa

Width / Height / Depth

mm

Net weight

kg

Possibility of vertical installation

Refrigerant Type refrigerant

Refrigerant charge

kg

Liquid / Gas pipe diameter

inch

Piping total length

m

Vertical piping max. length

m

Working range Outdoor ambient temperature for cooling min. / max. °C

Outdoor ambient temperature for heating min. / max. °C

KPDA-71 DVR15
7.03 3,22 / 7,91
7,62 2,78 / 8,56
2280 750 / 2860
2000 640 / 2500
3.08 3.81 6.5 - A++ 4.2 - A+ 4x1 KUE-71 DVR14 3500 60 69 890 / 673 / 342 41.9 220-240/1/50 (2+T)x2,5 KPD-71 DR15 700 / 1000 / 1200 31 / 32.5 / 33.5 56 160 1000 / 245 / 750 31.8 Yes
R-32 1.4 3/8" / 5/8" 50 25
-15 / 50 -15 / 24

KPDA-90 DVR15
8.79 2,22 / 9,50
9,38 2,69 / 9,79
2800 190 / 3400
2400 430 / 2600
3.14 3.91 6.3 - A++ 4.1 - A+ 4x1 KUE-90 DVR14 3800 63 70 946 / 810 / 410 51 220-240/1/50 (2+T)x2,5 KPD-90 DR15 900 / 1200 / 1500 35 / 37 / 39 58 160 1000 / 245 / 750 32.7 Yes
R-32 1.8 3/8" / 5/8" 50 25
-15 / 50 -15 / 24

KPDA-105 DVR15
10.55 2,75 / 11,14
11,73 2,78 / 12,78
3950 900 / 4150
3250 800 / 3950
2.67 3.61 6.2 - A++ 4.1 - A+ 4x1 KUE-105 DVR13 4000 63 70 946 / 810 / 410 66.9 220-240/1/50 (2+T)x4 KPD-105 DR15 1100 / 1300 / 1600 33 / 36 / 38 60 160 1200 / 245 / 750 38.4 Yes
R-32 2.4 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

KPDA-105 DTR15
10.55 2,75 / 11,14
11,73 2,78 / 12,84
4000 890 / 4200
3250 780 / 4000
2.64 3.61 6.1 - A++ 4.1 - A+ 4x1 KUE-105 DTR13 4000 63 70 946 / 810 / 410 80.5 380-415/3/50 (4+T)x2,5 KPD-105 DR15 1100 / 1300 / 1600 34 / 37 / 40 60 160 1200 / 245 / 750 38.4 Yes
R-32 2.4 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted.

KCT-04.1 SPSWF Standard

Set Model

Set

Cooling capacity rated

kW

Cooling capacity min. / max.

kW

Heating capacity rated

kW

Heating capacity min. / max.

kW

Cooling input rated

W

Cooling input min. / max.

W

Heating input rated

W

Heating input min. / max.

W

EER

COP SEER

SCOP

Shielded communication wiring

mm²

Outdoor unit Air flow Sound pressure

m³/h dB(A)

Sound power level

dB(A)

Width / Height / Depth

mm

Net weight

kg

Power supply Power wiring

V/ph/Hz mm²

Indoor unit Air flow low / medium / high

m³/h

Sound pressure low / medium / high

dB(A)

Sound power level Max. pressure available

dB(A) Pa

Width / Height / Depth

mm

Net weight

kg

Possibility of vertical installation

Refrigerant Type refrigerant

Refrigerant charge

kg

Liquid / Gas pipe diameter

inch

Piping total length

m

Vertical piping max. length

m

Working range Outdoor ambient temperature for cooling min. / max. °C

Outdoor ambient temperature for heating min. / max. °C

KPDA-125 DVR15
12.02 2,93 / 12,31
13,48 3,37 / 14,07
4200 680 / 4500
3450 750 / 4100
2.86 3.91 6.1 - A++ 4.0 - A+ 4x1 KUE-125 DVR13 4000 63 73 946 / 810 / 410 71.0 220-240/1/50 (2+T)x4 KPD-125 DR15 1300 / 1700 / 2000 36 / 37.5 / 39 65 160 1200 / 245 / 750 40.4 Yes
R-32 2.8 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

KPDA-140 DTR15
14.07 3,51 / 15,83
16,12 4,10 / 17,59
4800 810 / 6450
4600 950 / 5800
2.93 3.50 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DTR14 5600 64.5 73 990 / 975 / 375 90.0 380-415/3/50 (4+T)x2,5 KPD-140 DR15 1300 / 1700 / 2000 40 / 42 / 44 65 200 1200 / 245 / 750 40.4 Yes
R-32 2.9 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132

KPDA-140 DVR15
14.07 3,51 / 15,83
16,12 4,10 / 17,59
4800 810 / 6450
4600 950 / 5800
2.93 3.50 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DVR14 5600 64.5 73 990 / 975 / 375 82.0 220-240/1/50 (2+T)x4 KPD-140 DR15 1300 / 1700 / 2000 40 / 42 / 44 65 200 1200 / 245 / 750 40.4 Yes
R-32 2.9 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

KPDA-160 DTR15
15.24 4,10 / 17,30
17,59 4,39 / 20,52
5250 1030 / 6650
5150 950 / 6600
2.90 3.42 6.1 - A++ 4.0 - A+ 4x1 KUE-160 DTR14 5600 65 74 990 / 975 / 375 92.0 380-415/3/50 (4+T)x2,5 KPD-160 DR15 1500 / 1900 / 2200 41.5 / 43 / 44.5 66 200 1200 / 300 / 750 47.4 Yes
R-32 3.2 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted.

Floor Standing

R-32

DC INVERTER DC INVERTER SMART HOME

REFRIGERANT COMPRESSOR EXTERNAL FAN

ON/OFF CONTACT

SOUND LEVEL REDUCTION POSSIBILITY

Set Model
Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP SEER SCOP Shielded communication wiring
Outdoor unit Air flow Sound pressure Width / Height / Depth Net weight Power supply Power wiring
Indoor unit Air flow low / medium / high Sound pressure Sound power level Width / Height / Depth Net weight
Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length

kW kW kW kW W W W W
mm²
m³/h dB(A) mm kg V/ph/Hz mm²
m³/h dB(A) dB(A) mm kg
kg inch m m

KPVA-160 DTR14
15,25 4,11 / 16,13
18,18 4,40 / 18,77
6000 1000 / 7200
5600 1020 / 7200
2.54 3.24 5.8 4.0 - A+ 4x1 KUE-160 DTR14 5600 65 980 / 975 / 375 92 380-415/3/50 (4+T)x4 KPV-160 DR14 1600 / 1750 / 1950 40 / / 45.5 / 50.5 / / 53 / 64 600 / 1934 / 455 61.4
R-32 3.2 3/8" / 5/8" 75 30

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted.

Twin Cassette 840x840

KCT-04.1 SPSWF Standard

KCMI 112 Branch pipe

R-32

DRAINAGE

REFRIGERANT

PUMP

HERTZ

COMPATIBLE SMART HOME WITH AIRZONE

ON/OFF CONTACT

AIR INTAKE

FRESH AIR SUPPLY

Set model
Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP SEER SCOP Shielded communication wiring
Outdoor unit Air flow Sound pressure Sound power level Width / Height / Depth Net weight Power supply Power wiring
Indoor unit Air flow low / medium / high Sound pressure low / medium / high Sound power level Width / Height / Depth Net weight
Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length
Working range Outdoor ambient temperature for cooling min. / max. Outdoor ambient temperature for heating min. / max.

kW kW kW kW W W W W
mm²
m³/h dB(A) dB(A) mm kg V/ph/Hz mm²
m³/h dB(A) dB(A) mm kg
kg inch m m
°C °C

KCISA-71 DVR15 TWIN
14.07 3,51 / 15,83
16,12 4,10 / 17,59
4800 810 / 6450
4600 950 / 5800
2.93 3.50 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DVR14 5600 64.5 73 990 / 975 / 375 82.0 220-240/1/50 (4+T)x2,5 2x KCIS-71 DR14 1600 / 1750 / 1900 48 / 50.5 / 52.5 66 830 / 287 / 830 29.3
R-32 2.9 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132

KCISA-71 DTR15 TWIN
14.07 3,51 / 15,83
16,12 4,10 / 17,59
4800 810 / 6450
4600 950 / 5800
2.93 3.50 6.1 - A++ 4.0 - A+ 4x1 KUE-140 DTR14 5600 64.5 73 990 / 975 / 375 90.0 380-415/3/50 (4+T)x2,5 2x KCIS-71 DR14 1600 / 1750 / 1900 48 / 50.5 / 52.5 66 830 / 287 / 830 29.3
R-32 2.9 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

KCISA-90 DTR15 TWIN
15.24 4,10 / 17,30
17,59 4,39 / 20,52
5250 1030 / 6650
5150 950 / 6600
2.90 3.42 6.1 - A++ 4.0 - A+ 4x1 KUE-160 DTR14 5600 65 74 990 / 975 / 375 92.0 380-415/3/50 (4+T)x2,5 2x KCIS-90 DR14 1650 / 1850 / 2000 49.5 / 52 / 54.5 66 830 / 287 / 830 29.3
R-32 3.2 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted.

Twin Floor/Ceiling

KID-06 S Standard

KCMI 112 Branch pipe

R-32

DRAINAGE

REFRIGERANT

PUMP

HERTZ

COMPATIBLE SMART HOME WITH AIRZONE

ON/OFF CONTACT

AIR INTAKE

FRESH AIR SUPPLY

FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132

Set model
Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP COP at -7°C SEER SCOP Shielded communication wiring
Outdoor unit Air flow Sound pressure Sound power level Width / Height / Depth Net weight Power supply Power wiring
Indoor unit Air flow low / medium / high Sound pressure low / medium / high Sound power level Width / Height / Depth Net weight
Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length
Working range Outdoor ambient temperature for cooling min. / max. Outdoor ambient temperature for heating min. / max.

kW kW kW kW W W W W
mm²
m³/h dB(A) dB(A) mm kg V/ph/Hz mm²
m³/h dB(A) dB(A) mm kg
kg inch m m
°C °C

KPCA-52 DTR14 TWIN
2x 5,28 2.71 / 5.86
2x 5,57 2.42 / 6.3
1450 670 / 2027
1500 540 / 1640
3.61 2.6 6.1 - A++ 4 - A+ 4x1 KUE-105 DTR13 4000 63 70 946 / 810 / 410 66.90 380-415/3/50 (4+T)x2,5 2x KPC-52 DR14 723 / 839 / 958 37 / 41 / 44 59 1068 / 235 / 675 28
R-32 2.4 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

KPCA-52 DVR14 TWIN
2x 5,28 2.71 / 5.86
2x 5,57 2.42 / 6.3
1450 670 / 2027
1500 540 / 1640
3.71 2.6 6.1 - A++ 4 - A+ 4x1 KUE-105 DVR13 3800 62 70 946 / 810 / 410 52.8 220-240/1/50 (2+T)x4 2x KPC-52 DR14 723 / 839 / 958 37 / 41 / 44 59 1068 / 235 / 675 28
R-32 2.4 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

KPCA-71 DVR15 TWIN
14.07 3,51 / 15,83
16,12 4,10 / 17,59
4800 810 / 6450
4600 950 / 5800
2.93 3.50
6.1 - A++ 4.0 - A+
4x1 KUE-140 DVR14
5600 64.5 73 990 / 975 / 375 82.0 220-240/1/50 (4+T)x2,5 2x KPC-71 DR14 853 / 1023 / 1192 43 / 47 / 51 55 1068 / 235 / 675 28
R-32 2.9 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

KPCA-71 DTR15 TWIN
14.07 3,51 / 15,83
16,12 4,10 / 17,59
4800 810 / 6450
4600 950 / 5800
2.93 3.50
6.1 - A++ 4.0 - A+
4x1 KUE-140 DTR14
5600 64.5 73 990 / 975 / 375 90.0 380-415/3/50 (4+T)x2,5 2x KPC-71 DR14 853 / 1023 / 1192 43 / 47 / 51 55 1068 / 235 / 675 28
R-32 2.9 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. *In these models it is possible to combine horizontal and vertical units. If you require the vertical, request the reference with the V.

Twin Duct

Set model
Set Cooling capacity rated Cooling capacity min. / max. Heating capacity rated Heating capacity min. / max. Cooling input rated Cooling input min. / max. Heating input rated Heating input min. / max. EER COP SEER SCOP Shielded communication wiring
Outdoor unit Air flow Sound pressure Sound power level Width / Height / Depth Net weight Power supply Power wiring
Indoor unit Air flow low / medium / high Sound pressure low / medium / high Sound power level Max. pressure available Width / Height / Depth Net weight Possibility of vertical installation
Refrigerant Type refrigerant Refrigerant charge Liquid / Gas pipe diameter Piping total length Vertical piping max. length
Working range Outdoor ambient temperature for cooling min. / max. Outdoor ambient temperature for heating min. / max.

kW kW kW kW W W W W
mm²
m³/h dB(A) dB(A) mm kg V/ph/Hz mm²
m³/h dB(A) dB(A) Pa mm kg
kg inch m m
°C °C

KPDA-35 DVR15 TWIN
7.03 3,22 / 7,91
7,62 2,78 / 8,56
2280 750 / 2860
2000 640 / 2500
3.08 3.81 6.5 - A++ 4.2 - A+ 4x1 KUE-71 DVR14 3500 60 69 890 / 673 / 342 41.9 220-240/1/50 (2+T)x2,5 2x KPD-35 DR15 300 / 480 / 600 30 / 32 / 34 56 100 700 / 200 / 506 18 No
R-32 1.4 3/8" / 5/8" 50 25
-15 / 50 -15 / 24

FOR COMPATIBLE CONTROLS AND ACCESSORIES SEE PAGE 132

KPDA-52 DTR15 TWIN
10.55 2.75 / 11.14
11.72 2.78 / 12.78
3950 900 / 4150
3250 800 / 3950
2.6 3.71 6.1 - A++ 4.0 - A+ 4x1 KUE-105 DTR13 4000 63 70 946 / 810 / 410 80.5 380-415/3/50 (4+T)x2,5 2x KPD-52 DR15 600 / 780 / 900 34 / 31 / 36.5 53 160 700 / 245 / 750 24.4 Yes
R-32 2.4 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

KPDA-52 DVR15 TWIN
10.55 2.73 / 11.78
11.72 2.78 / 12.84
4000 890 / 4200
3250 780 / 4000
2.7 3.71 6.1 - A++ 4.0 - A+ 4x1 KUE-105 DVR13 4000 63 70 946 / 810 / 410 66.9 220-240/1/50 (2+T)x4 2x KPD-52 DR15 600 / 780 / 900 34 / 31 / 36.5 53 160 700 / 245 / 750 24.4 Yes
R-32 2.4 3/8" / 5/8" 75 30
-15 / 50 -15 / 24

Data for standard conditions. The actual operation conditions depend on the place in which the equipment has been installed and the use made of it. Sound pressure: Measurement of the sound pressure is taken using a semi-anechoic chamber at a distance of 1 m from the machine. Power wiring: The power wiring is up to 10 m approximately. It must be calculated more precisely for each installation. Supplementary charge: The initial factory charge of the machines is valid for the first 5 m (liquid line). For greater distances, a supplementary charge is required, in accordance with the formula 0.012 kg/m × (L-5) in the liquid line is 1/4". For greater diameters, use 0.024 kg/m × (L-5). Compatible controllers: The units can integrate one of the controllers from the table or the one recommended by Kaysun. For further information regarding compatibility, see the chapter on Controllers. NOTE: Before installing these units, current legislation regarding refrigerant gases must be consulted. *In these models it is possible to combine horizontal and vertical units. If you require the vertical, request the reference with the V.