Instruction Manual for Pegasus models including: PP-6750V Series Dual Frequency Time Attendance Recorder, PP-6750V Series, Dual Frequency Time Attendance Recorder, Time Attendance Recorder, Attendance Recorder, Recorder

PG-2750C 智慧型門禁卡鐘刷卡機

pg

Manual chi tiết

Tài liệu hướng dẫn sử dụng đầu đọc kiểm soát ra vào Pegasus PP-6750V Series


File Info : application/pdf, 44 Pages, 1.53MB

PDF preview unavailable. Download the PDF instead.

pp-6750vusermanual-212
PC On-Line Time Attendance Recorder & Access Controller
Access Control/Time & Attendance / Lift Access Control System/ Security
PP-6750V Series Operational Manual
Ver.21.2
2110 W-04-6750V/E 1

Table of contents

System Introduction

1

General Features

1

Specification

3

LCD instruction

4

Panel Description

6

Bottom View

6

Wiring Connectors and PIN assignment

7

Example of Wiring

9

Controller and Relay Box Wiring Example

11

Macro instruction

13

Brief system programming

15

Change the master PIN

15

Function code instruction

15

F0: Delete all personal map

15

F1:Access by key in user ID through master PIN 15

F2:Set weekday, hour, minute

16

F3:Calendar year, month and date setting

16

F4: Parameters & Modes

16

Group 0.System Initiation

30

Group 1.Input Commands

31

Group 2.Output Commands

31

Group 3.Operation Modes

32

Group 4.Pin Or Master Pin Setting

33

Group 5.Inquiry Mode

33

Group 6.Time Zone Mode/Add Card Mode 33

Group 7.Delete Card Mode

33

Group 8.System Configurations

33

2

Group 9. Factory Configuration

35

F5 : Inquiry mode

17

A. Single card inquiry

17

B. Inquiry with learning mode

17

C. Inquiry card status by block mode

17

F6:Add personal map

18

A. Add card no.

18

B. Add card no. and PIN

18

C-1. Add card with learning mode

19

C-2. Learning mode from group nn

19

D. Add card with block mode

19

F7: Delete personal map

20

A. Delete single card

20

B. Delete card with leaning mode

20

C. Delete card with block mode:

20

D. Delete card with block mode

20

F8: Time zone/holiday/bell programming

21

A. Personalized mode

21

A-1. Time Zone Mode/Add Card Mode

22

A-2. Group with floor setting

23

A-3. Personalized time zone inquiry

23

A-4. Delete time zone

23

B. Free access mode

24

B-1. Auto duty mode

24

B-2. Auto mode

26

C. Holiday mode

27

C-1. Holiday inquiry

27

D. Bell alarm mode

28

3

D-1. Bell alarm inquiry mode

28

F9: Modify events counter for event retrieving 29

F*: Inquiry and display the stored events

29

Simple and easy trouble shooting

36

Appendix

39

4

Packing List
Before getting start, please check the 6750V package contains the
following items:

DESCRIPTION
The system unit

Q'TY
1 unit

1 9 Pin connector (Blue) 1 pc

2 8 Pin connector (White) 1 pc

3 4 Pin connector (White) 1 pc

4 3 Pin connector (White) 1 pc

5 Screw

1 pc

6 Free wheeling diode

1 pc

7

Sealing rubber for waterproof

1 pc

5

System introduction
6750V is an intelligent time recording terminal designed to meet the variant applications in time attendance and access control, lift control & ARM/DISARM security requirements.Each terminal can be operated independently or through PC/Internet adapter PC-T100 to fulfill the multiple terminal system. The recording terminal includes nearly all the necessary functions for time recording and access control.Users can use master PIN to select the desired functions from the abundant functional list (For malfunction, please contact with your local distributors) The system could be started by modifying the factory defaulted templated as by code F4 + 0850 and then save them by 0650 to back up for farther configuration your system by 0950, if you confused your configuration.
General Features
1-A Time recording features: 1High capacity with 8 digits card number / 6 digits staff number and 8
character English name.( Either checking or without checking personal map ) 216 characters x2 rows of LCD disply with 8 digits which have year, month,day,week,time, IP,operation mode,real time mode,unlock time, door monitoring. 379 duty codes, duty name defined by PC. 4Selectable batch or real time on-line mode. 5Key in 8 digits ID for time attendance recording. 6Totally 192 alarm schedules (8 schedules per hour) dry contacts output for periodic bell announce.
There are 6 versions available: (1)K Version: 1,000 card capacity, 500 events. (2)L Version: 2,000 card capacity, 1,000 events. (3)M Version: 30,000 card capacity, 10,000 events. (4)N Version: 11,000 card capacity, 32,000 events. (5)P Version: 11,000 card capacity, 8,000 events. (6)X Version: 32,000 card capacity, 32,000 events. Versions could be getting thru the equipped RS-485 interface.
1-B. Access control features: (Main application)
1

1. System parameters and personal access map can be down loaded by PC or manually programmed through keypad.
2. The personal access map is consisted of card ID, staff number and staff name, PIN and Time Zone Status, expiry date and Anti-passback.Operation modes : (1) card only (2) card + PIN (3)Door PIN only and duress feature (4)Card no +PIN and duress feature(5)Free access (6) Automatic operation mode by time zones
NOTE: The staff name is used under F4=9601, 3400 cards capacity only. 3. Individual personal access map can be added/deleted and checked by
on-lined PC or through manually in single / block range card number or by direct reading card in learning mode. 4. Selectable immediate or batched serial output for event printing 5. With complete door release, status monitoring and intruded alarm periord & error trials.
2

Specification
Dimensions Weight Power supply Transmission rate Operating temperature Operating humidity Keypad Password Serial interface Serial output Card capacity /Events
Card standard
External Reader

137mm(L) x 85mm(W) x 29mm(H)
340g± 5%
DC 12V±10%, 80mA~100mA(not include power requirement for lock & alarm)
Default 9,600 bps N,8,1(2,400bps/4,800bps) (19,200bps/38,400bps<selectable>)
-20 ~ 70
10%~90%
3 x 4 keypad for system programming, pass word entry or duty code selection.
Programmable 4 digits PIN for each person
RS-485/RS-232(Optional)
1. For connection with serial printer. 2. To drive DDR (digital door relay) for safety
control model. 3. Lifts controller. common door codes (1) K Version: 1,000 card capacity, 500 events. (2) L Version: 2,000 card capacity, 1,000 events. (3) M Version: 30,000 card capacity, 10,000 events. (4) N Version: 11,000 card capacity, 32,000 events. (5) P Version: 11,000 card capacity, 8,000 events. (6) X Series: 32,000 card capacity, 32,000 events. Other capacity combination requested by order 125KHz ASK EM / 125KHz FSK HC / 13.56MHz Mifare (ISO 14443A , ISO 14443B, ISO 15693) / 13.56MHz Felica (ISO 18092 UID) / Q type / NFC / Bluetooth  Support customized card. With one or optional two port for external Wiegand (26/34/35/36/37/40 bits definable by command) & ABA input (by order)

Mifare is a registered trademark of NXP B.V. FeliCa is a trademark of Sony Corporation.

3

LCD instruction

Normal Display: After plug-in power, LCD displays as below:

Y Y / M M / D D h hm m XXX. +NNNNN

Y Y/ M M / D D: The calendar year, month and date (Year/ Month/ Day) h h:mmSystem clock, Hour & Minute (hh=00~23;mm=00~59) X X Xweekday Monday to Sunday
NNNNNThe transaction records stored in the buffer.
When display shows "FULL", which means the butter is full. Please download the records by PC or press Master PIN and then press"9",key-in "000000" to erase the events.

Parameter display: key-in 9, LCD displays as below:

First display

Aaa

W t

stt 96

A D R . W A T . D O R . BPS

Parameter value Parameter name

Aaa : Polling address by F4=88aa (00~99) WAT Real time on-line waiting time by F4=890t (0~9), 0 for
baten mode by F4=99nn DOR Door released time by F4=21tt(00~99), S= second, M=minute
BPS Buad Rate 96=9600 48=4800 24=2400 19=19200

Second display N

sWt

t t

N-N

REP. MOT. DPT. T-A

Parameter value Parameter name

REPDoor Monitoring Status time for check repeat reads in unit of second N=t Check repeating card with t minutes N=0 No repeating card check
MOT: Door monitoring time by code F4=230t, S= second DPT : LCD message display time by F4=250t, useful for F T-A :Time zone control ­ Free access mode
4

Y - Enable function N -Disable function *Note: The system could be operated in proper order only when the address code is correctly programmed through 88nn. If the reader address is not correctly programmed, the display of address will show some other ASCII characters as xxx above the ADR.which can't save the event; therefore you should program again. Third display
R.r r r r r W.w w w w w Version P 6957FXXX
R.rrrrr: The read counter of buffer W.wwwww: The write counter of buffer Version:CPU version Note: Accoring to actual version.
5

Panel Description Bottom View
6

Wiring Connectors and PIN assignment
A. J2-9P Blue (For power input and access functions)
Note: Please connect the blue wire to GND if the Door Monitoring function is unnecessary. Please connect the purple wire to GND if the Security Sensor function is unnecessary. B. J1-8P White (For on-line interface & alarm output)
7

Need to set F4 = 9816, when connect with
the external reader that Model No. is included PW26 Note 1. The distance between Main reader and external reader sould be over 30cm to prevent mutual interference. 2. Please put some more no-metal plate between the reader & metal plate to enhance the reading distance.
8

Example of how to wiring
9

R-27-YK10T1/125/250V is line filter to avoid signal interference. If elevator controller doesn't work; please turn off Bypass switch
of non-controlled button. To connect 2 or 3 of 24 floor controllers to achevie 64 floors access
of set up. Please refere appendix for floor controller of relate operation manner.
10

Controller and Relay Box Wiring Example

2750/3750/85/6750V 9 Pin Blue Connector Color Signal Name No1.Red +12V No2.Black GND No3.Brown No4.Orange No5.Yellow No6.Green No7.Blue No8.Purple No9.Gray Serial Printer Output

PG-OUTMOD-8 Relay Box

J5-7 Pin Blue Connector

Color

Signal Name

No1.Red +12V

No2.Black GND

No3.Orange No Connection

No4.Purple Serial Printer Input

No5.Black No Connection

No6.Gray No Connection

No7. Gray No Connection

2750/3750/85/6750V 9 Pin Blue Connector Color Signal Name No1.Red +12V No2.Black GND No3.Brown No4.Orange No5.Yellow No6.Green No7.Blue No8.Purple No9.Gray Serial Printer Output

POM-24 Relay Box

J5-9 Pin Blue Connector

Color

Signal Name

No1.Red +12V

No2.Black GND

No3.Brown No Connection

No4.Orange Serial Printer Input

No5.Yellow No Connection

No6.Gree No Connection

No7. Blue No. Connection

No.8 Purple

No.9 Gray

System Initialize (default password 246890) Please set the F4 = 0016 / F4 = 0018 / F4 = 0019 / F4 = 0 072 to prevent the time zone data occupy memory and further caused the card number can not be enrolled. The system initialization means the system parameters are defaulted by F4=0850(off-line mode) or F4=0750(on-line mode). Then the user could modify some parameters based on it. After each modification to individual requirement, the user may backup them by code F4=0650. Once the
11

parameters are destroyed, the code F4=0950 could be applied to restore it. All the function code under F4 is disabled, except the timer for 21tt, 22..... 1. Door monitoring:Disable the door monitor function ( F4=1100 ) 2. Presonal map compareNot compare ( F4=1500 ) 3. Door release time :close one second(F4=2101) 4. Door open modecard only mode(F4=3200) 5. Anti-pass back mode : Disable (F4=3900) 6. Check repeat card : Disable(F4=8300) 7. Printer output functionDisable ( F4=8600 ) 8. When event buffer fullNot recycle ( F4=8700 ) 9. Computer connect modereal time mode ( F4=8903 )-F4=0750
batch mode ( F4=8900 )-F4=0850 10. Card display formatComparing card number 5th, 6th, 7th digits
( F4=9704 )
Operating instruction The manager could program the controller by pressing 0 and master PIN (default password as 246890.The password could be modified by F4=4609) to enter into the PROGRAM mode.
Summary of fuctions code please refer to ndex on the system introduction. F00 : Delete all personal map F11 : Key in user ID for access by master PIN F22 : Set weekday, hour, minute F33 : Program Calendar year, month and date F44 : Parameter modes & Modes F55 : Inquiry Personal access map F66 : Add personal map F77 : Delete personal map F88 : Time zone/holiday/bell programming & Inquiry F99 : Modify events counter for event retrieving F10*: Display or print out recorded NoteThe programming procedures could be escaped by pressing "#" by key.
12

Macro Instruction(Optional)

For "Access Control"macro instruction

F4=0851

Step

Press[0]master PIN [246890]Press[4] Press[0851]

Parameter mode:

F4=9996 :Baud rate:9600

F4=2500

F4=9803 :Wiegand 26 bits card number. F4=1101

F4=2106 :Door release time: 6 sec.

F4=3402

F4=1501 :Enable comparing card number. F4=9705

F4=8700 :For FIFO mode.

Description For PN/Q/M8/M1 format
:The shortest time of display. :Enable the door monitoring. :Enable door PIN mode. :Compare card number by
6th , 7th , 8th digits.

F4=0852

Step

Press[0]master PIN [246890]Press[4] Press[0852]

Parameter mode:

F4=9996 :Baud rate:9600

F4=2500

F4=9808 :Wiegand 34 bits card number. F4=1101

F4=2106 :Door release time: 6 sec.

F4=3402

F4=1501 :Enable comparing card number. F4=9704

F4=8700 :For FIFO mode.

Description For M0 format
:The shortest time of display. :Enable the door monitoring. :Enable door PIN mode. :Compare card number by
5th , 6th , 7th digits.

For "Lift Control" macro instruction

F4=0853

Step

Press[0]master PIN [246890]Press[4] Press[0853]

Parameter mode:

F4=9996 :Baud rate:9600

F4=2500

F4=9803 :Wiegand 26 bits card number. F4=8610

F4=2108 :Door release time: 8 sec.

F4=1100

F4=1501 :Enable comparing card number. F4=9705

F4=8700 :For FIFO mode.

F4=0854

Step

Press[0]master PIN [246890]Press[4] Press[0854]

Parameter mode:

F4=9996 :Baud rate:9600

F4=2500

F4=9808 :Wiegand 34its card number. F4=8610

F4=2108 :Door release time: 8sec.

F4=1100

F4=1501 :Enable comparing card number. F4=9704

F4=8700 :For FIFO mode.

Description For PN/Q/M8/M1format
:The shortest time of display. :Enable lift control 8 floor. :Disable the door monitoring. :Compare card number by 6th ,7th , 8th digits.
Description For M0 format
:The shortest time of display. :Enable lift control 8 floor. :Disable the door monitoring. :Compare card number by 5th
6th, 7th digits.

13

F4=0855

Step

Press[0]master PIN [246890]Press[4] Press[0855]

Parameter mode:

F4=9996 :Baud rate:9600

F4=2500

F4=9803 :Wiegand 26 bits card number. F4=8623

F4=2108 :Door release time: 8 sec.

F4=1100

F4=1501 :Enable comparing card number. F4=9705

F4=8700 :For FIFO mode.

F4=0856

Step

Press[0]master PIN [246890]Press[4] Press[0856]

Parameter mode:

F4=9996 :Baud rate:9600

F4=2500

F4=9808 :Wiegand 34 bits card number. F4=8623

F4=2108 :Door release time: 8 sec.

F4=1100

F4=1501 :Enable comparing card number. F4=9704

F4=8700 :For FIFO mode.

F4=0857

Step

Press[0]master PIN [246890]Press[4] Press[0857]

Parameter mode:

F4=9996 :Baud rate:9600

F4=2500

F4=9803 :Wiegand 26 bits card number. F4=8633

F4=2108 :Door release time: 8 sec.

F4=1100

F4=1501 :Enable comparing card number. F4=9705

F4=8700 :For FIFO mode.

F4=0858

Step

Press[0]master PIN [246890]Press[4] Press[0858]

Parameter mode:

F4=9996 :Baud rate:9600

F4=2500

F4=9808 :Wiegand 34 bits card number. F4=8633

F4=2108 :Door release time: 8 sec.

F4=1100

F4=1501 :Enable comparing card number. F4=9704

F4=8700 :For FIFO mode.

Description For PN/Q/M8/M1format
:The shortest time of display. :Enable lift control 24 floor. :Disable the door monitoring. :Compare card number by
6th, 7th , 8th digits.
Description For M0 format
:The shortest time of display. :Enable lift control 24 floor. :Disable the door monitoring. :Compare card number by 5th, 6th, 7th digits.
Description For PN/Q/M8/M1format
:The shortest time of display. :Enable lift control 48 floor. :Disable the door monitoring. :Compare card number by 6th, 7th, 8th digits.
Description For M0 format
:The shortest time of display. :Enable lift control 48 floor. :Disable the door monitoring. :Compare card number by 5th, 6th, 7th digits.

14

Brief system programming

Change the master PIN

Ex.Change the master PIN to 654321than F4+4609+654321. The new

master PIN would be changed to 654321

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM--

Enter into programming mode

Press[4]

FUNC-->--------

Parameter mode (F4)

Press[4609] +new master PIN[KKKKKK]

MST.PIN- KKKKKK >

KKKKKK would be the Password

Function code instruction

F0: Delete all personal map

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM--> Enter into programming mode

Press[0]

CLRALL-------- Delete mode(F0)

Press [0000]

END---

INSTRUCTION

Repeat the last step or press [#] to escape from the programming.

F1: Direct keying master PIN Ex. : Administrator puts in 8 codes ID of user with the personal password for a user when someone forgets bring his card The personal password is set up by F4=3300(read a card with password model) + F6(setting personal password). Above setting can be done on the controller or computer.

Step Press[0] + master PIN [246890]
Press[1] Press card number [12345678]
Press personal password [9999]

LCD

Description

PROGRAM--> Enter into

programming mode

ID No.-------- Access mode(F1)

PIN---

Put in the legal card

numbers

Put in the personal

password

15

F2: Weekday, hour, minute setting

Step

LCD

Description

Press[0] + master PIN [246890] Press[2]

PROGRAM--> Enter into programming mode
TIME---------- Time mode (F2)

Press[201536]

Tuesday, 15:36 pm

--
Weekday code(0~6)
0 : Sunday 1 : Monday 2 : Tuesday 3 : Wednesday

   
Minute (0~59) Hour (0~23) Don't cared digit(0~9) 4 : Thursday 5 : Friday 6 : Saturday

F3: Calendar year, month and date setting

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM--> Enter into

programming mode

Press[3]

YEAR---------- Date mode (F3)

Press[091025]

2009/10/25

--  

Date(01-31)

Year 2008

Month(01-12)

After key 0 + (default master PIN) then you could press 4 plus following function codes divided in groups for easy memorize.

F4: Most system parameters programming

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM--> Enter into

programming mode

Press[4]

FUNC---------- Parameter mode (F4)

Press 4 digit function code

FUNC--XXXX

Please refer to the function code

16

F5: Inquiry mode A. Single card inquiry
Step Press[0] + master PIN [246890] Press[5] Press card NO.[1 2 3 4 5 6 7 8]
Repeat the last stepstep or press [#] to escape from the programming.
C1C2C3C4C5C6C7C8 nn k k k k

LCD PROGRAM-->
CARD--------
12345678=10=9999 ZONE0 1 0 0 . 0 0 0 1 C1C2C3C4C5C6C7C8 nnk k k k ZONE Z1 Z2 Z3 Z4 . Z5 Z6 Z7 Z8

Card number

4 digits PIN

Group no.

ZONE:

Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8: 1~8 individual authorized time zone status.

1: Authorized time zone

0: Unauthorized time zone

B. Inquiry with learning mode (F4=5333)

Step

LCD

Press[0] + master PIN [246890] PROGRAM-->

Press[4]

FUNC

Press[5333]

CARD-LEARN->

Present card

CARD-LEARN->

ZONE0 1 0 0 . 0 0 0 1
Repeat the last stepstep or press [#] to escape from the programming.

C. Inquiry card status by block mode (F4=5500)

Ex. Inquiry card no. from 00020376 to 00020576

Step

LCD

Press[0] + master PIN [246890]

PROGRAM-->

Press[4]

FUNC

Press[5500]

CARD-BLOCK->

Press[00020376 1 2 0576]

0 0 0 2 0 3 7 6 =12=9999

ZONE0 1 0 0 . 0 0 0 1

17

B1B2B3B4B5B6B7B8 X X E5E6E7E8

Starting card no.

Last 4 digits of ending
card number Time zone status (F4=1601) 00: Illegal 10: Clear all time zones 19: Authorize all time zones 1n: Authorize individual time zone (1~8)

F6: Add personal map A. Add card no. with group number(Under F4=3200)

Step

LCD

Press[0] + master PIN [246890] PROGRAM-->

Press[6]

ADD CR--------

Description Enter into programming mode Add mode(F6)

Press card NO.[12345678nn] ADD CR

Add card no.12345678,

And group no. nn

(nn=00-99)

Repeat the last step or press [#] to escape from the programming.

B. Add card No. and PIN (Under F4=3300) Ex.Set up card No.=12345678 and PIN=9999, group No. 02

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM-->

Press[6]

ADD CR--------

Enter into programming mode Add mode(F6)

Press [12345678 02 9999]

ADD CR--------

Card number:12345678 Group: 2

Password: 9999

Repeat the last step or press [#] to escape from the programming.

c c c c c c c c nn k k k k

Card no.

4 digits PIN

Group no. nn=01-99

18

C-1. Add card with learning mode: ( F4 = 6333)

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM--> Enter into

Press[4]

*FUNC 

programming mode Add mode(F4)

Press[6333]

*ADD CR>-LEARN-> Learning mode

Present card

*ADD CR>-LEARN-> C1C2C3C4C5C6C7C8

Repeat the last step or press [#] to escape from the programming.

C-2. Learning mode from group nn (nn=00~79)

Step

LCD

Description

Press[8]

DUTY.2d

Enter into programming mode

Press group nn (nn=00~79)

nn will be shown on the right-up corner of the LCD

Setting group no.

Press[0] + master PIN [246890] PROGRAM-->

Enter into

Press[4]

*FUNC 

programming mode Add mode(F4)

Press[6333]

*ADD CR>-LEARN-> Learning mode

Present card

*ADD CR>-LEARN->

C1C2C3C4C5C6C7C8

Repeat the last step or press [#] to escape from the programming.

D. Add card by block mode: (F4 = 66nn)

Ex.Add card no. from 00020376 to 00020576, group no.01

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM--> Enter into

programming mode

Press[4]

*FUNC 

Add mode(F4)

Press[66nn]

ADD CR-BLOCK-> block mode

(nn=group 01~99)

Press [00020376 01 0576]

from 00020376 to 00020576, group no.01

Repeat the last step or press [#] to escape from the programming.

B1B2B3B4B5B6B7B8 nn E5E6E7E8

The starting card no..

The last 4 digits of ending cardNo.

Group no.

19

F7: Delete personal map

A. Delete single card

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM-->

Press[7] Press card No.[12345678]

DELETE-------DELETE--------

Enter into programming mode Delete mode(F7)
Delete card No.12345678

Repeat the last step or press [#] to escape from the programming.

B. Delete card with leaning mode (F4=7333)

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM-->

Enter into

Press[4]

FUNC 

programming mode Parameter mode(F4)

Press[7333]

* DELETE >-LEARN-> learning mode

Present card

* DELETE >-LEARN-> Reading cards

CCCCCCCC

to delete cards

Repeat the last step or press [#] to escape from the programming.

C. Delete time zone from group nn(nn=01~99)(F4=72nn)

Step

LCD

Description

Press [0] + master PIN [246890] *PROGM*-->

Enter into

Press [4]

FUNC

programming mode Parameter mode(F4)

Press [72nn] Press [81828384]

DELETE>-GROUP-> Group [nn] DELETE>--------- Delete time zone 1,2,3,4,

Press [85868788]

DELETE>--------- 5,6,7,8

Press [#]to escape from the programming.

D. Delete card with block mode: (F4 = 77nn)

Ex. Delete card no. from 00020376 to 00020576

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM-->

Enter into

Press[4]

FUNC 

programming mode Parameter mode(F4)

Press [77nn] Press [00020376 nn 0576]

DELETE-BLOCK->

Delete with block mode (nn=group 01~99)
from 00020376 to

00020576

Repeat the last step or press [#] to escape from the programming.

20

C1C2C3C4C5C6C7C8 nn E5E6E7E8

The first card No..

Group no. But don't cared

The last 4 digits of ending card No.

F8: Time zone/holiday/bell programming A. Personalized mode (F4=1601, time zone 01~08) B. Free access mode (F4=3801, time zone 11~18) C. Holiday mode (F4=1801) D. Bell alarm mode (F4=2801)

A. Access time zone setting

Ex. define a time zone from 20:01 till 06:59 next day for Monday,

Tuesday & Friday. Please define by TZ1= 2001-2359 and

TZ2= 0000-0659 for crossing midnight

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM--> Enter into

programming mode

Press [8]

ZONE---------

Time zone mode(F8)

Press [601 2001 2359]

GDAY-

The first time zone is 20:01pm to 23:59pm

Press [1 1111111 1]

ZONE----------

Available for Monday

to Sunday

Press [602 0000 0659]

GDAY-

The second time zone is

morning of next day

00:00am to 06:59am

Press [0 0100110 1]

ZONE----------

Available for Monday to

Sunday

Repeat the last step or press [#] to escape from the

Setting 8 time zones

programming.

the most

-- 0 n
6: Add time zone Time zone (0108)

HHMM hhmm

Starting time

Ending time h h: hour (00~23)

mm: minute (00~59)

21

G-DAY: defined as the following: d1 d2 d3 d4 d5 d6
Mnemonic g w6 w5 w4 w3 w2 meaning gen. Sat Fri Thu Wed Tue

d7 d8 w1 w0 Mon Sun

d9 D Duty code

d1-- general week enable/disable =1: general authorized, d2 ~ d8 are ignored =0 : not general authorized, d2 ~ d8 should be entered one by one

d2 ~ d8--individual weekday enable/disable = 1: legal
= 0: denied d9--Auto mode by time zone
= 1: with key = 0: keypad less

A-1 Time Zone Mode/Add Card Mode

62nn Setting time zone for group (nn=01~95) (Under F=1601)

Note: Please delete all group data for first time setting group. (F4=0072)

Step

LCD

Description

Press [0] + master PIN [246890] *PROGM*-->

Enter into

programming mode

Press [4]

FUNC

Parameter mode(F4)

Press [62nn]

ADD CR>-GROUP-> Group [nn]

Press [81838183]

ADD CR>---------

Legal time zone 1,3

Time Zone: Time Zones 01~08 should be corresponding 81~88.

Ex. Group no. 3 is legal for time zone 01,03,05, you should program

F4=6203 81838581.

Ex. Group no. 3 is legal for time zone 01,03, you should program F4=6203 81838183.

Ex. Group no. 3 is legal for time zone 01, you should program F4=6203 81818181.

22

A-2. Group with floor setting (put in floor number 01~96) (F4=8613/8623/8633)

Step

LCD

Description

Press [0] + master PIN [246890] *PROGM*-->

Enter into

programming mode

Press [4]

FUNC Parameter mode(F4)

Press [62nn]

ADD CR>-GROUP-> Group [nn]

Press [01020363]

ADD CR>---------

Legal 1th,2th,3th and

63th floors

Press [#] to finish.Please repeat the step4 for adding the fifth floor.You should fill out 8

digits for floor and fill with 00.. for blank floor like 05060000 which is legal for 5th and 6th

floors.

A-3. Personalized time zone inquiry (time zone=01~08)

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM--> Enter into

programming mode

Press [8]

ZONE---------- Time zone mode(F8)

Press [5 0 2 0 0 0 0 0 0 0 0]

ZONE---------02=0900=1000=GA1

--5 0 n xxxxxxxx
5: Inquiry time zone content
Time zone no. (0108) Any 8 digits key

A-4. Delete time zone

Step

LCD

Press[0] + master PIN [246890] PROGRAM-->

Press [8] Press[702 0 0 0 0 0 0 0 0]

ZONE----------

Description Enter into programming mode Time zone mode(F8) Delete time zone 2

7 0 n xxxxxxxx

7: Time zone deletion Time zone (0108)

Any key (8 digits)

23

B. Free access mode (Time zone=11~18) (F4=3801)

Ex. Door released period decided by Nth time zone 0900-1800 on Saturday

& Sunday

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM-->

Enter into

programming mode

Press [8]

ZONE----------

Time zone mode(F8)

Press [611 0900 1800]

GDAY----------

Door released under

Press [0 100000001 1]

ZONE----------

normal open mode on

Monday to Sunday

Repeat the last step or press [#] to escape from the programming. Setting 8 time zones

the most

Zone: defined as the following:

6

1n

h h m m

h h m m

time zone 6:Add time zone (11~18)

starting time

Ending time

B-1. Auto duty mode (Time zone=11~18)(F4=3802)

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM-->

Enter into

programming mode

Press [8]

ZONE----------

Time zone mode(F8)

Press [611 0900 1200]

GDAY---------- Time zone 09:00-12:00

Press [1 1111111 1]

ZONE----------

Shift code is 1

for Monday to Sunday

Repeat the last step or press [#] to escape from the

Setting 8 time zones

programming.

the most

Zone: defined as the following:

6

1n

h h m m

h h m m

6: Add time zone

Time zone r(11~18)

Starting time Ending time 24

G-DAY: defined as the following: d1 d2 d3 d4 d5 d6
Mnemonic g w6 w5 w4 w3 w2 meaning gen. Sat Fri Thu Wed Tue

d7 d8 w1 w0 Mon Sun

d9 D Duty code

d1-- general week enable/disable =1: general authorized, d2 ~ d8 are ignored
=0 : not general authorized, d2 ~ d8 should be entered one by one d2 ~ d8--individual weekday enable/disable
= 1: legal = 0: denied d9--Auto duty mode by time zone = 1: enable(1~7), expect 4 = 0: disable

Duty LCD Meaning

code display

1 WORK On duty

2 OFF

Off duty

3 O.ON Over time, on duty

4 SYSTEM Reserved for system

service only

Duty LCD Meaning

code Display

5-- OUT Out 6 BACK Return job

7-- BRK Break 8 DUTY. 2 digits job code define

2d

by user

25

B-2. Auto mode (Time zone no.=11~18)(under F4=3803)

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM--> Enter into

programming mode

Press [8]

ZONE---------- Time zone mode(F8)

Press [611 1900 2359]

GDAY---------- Time zone 09:00~23:59

Press [1 1111111 1]

 ZONE---------- Password is required after

presenting a card for

Monday to Sunday

Repeat the last step or press [#] to escape from the

Setting 8 time zones the

programming.

most

Zone: Defined as the following

6

1n

h h m m

h h m m

6:Add time zone Time zone (11~18)

starting time

Ending time

G-DAY: Defined as the following: d1 d2 d3 d4 d5 d6 d7 d8 d9
Mnemonic g w6 w5 w4 w3 w2 w1 w0 D Meaning gen. Sat Fri Thu Wed Tue Mon Sun Duty code
d1-- general weekdays enable/disable =1: general authorized, d2 ~ d8 are ignored =0 : not general authorized, d2 ~ d8 should be entered one by one

d2 ~ d8-- individual weekday enable/disable = 1: legal = 0: denied

d9--Auto mode by time zone = 1: with key = 0: keypad less
26

C. Programming Holidays ( F4=1801 )

Step

LCD

Press[0] + master PIN [246890] PROGRAM-->

Press [8] Press [101 1001 1010]

ZONE---------ZONE----------

Press [102 1002 1025]

ZONE----------

Press [103 1003 1031]

ZONE----------

Repeat the last step or press [#] to escape from the programming.

Description
Enter into programming mode Time zone mode(F8)
1001: the first holiday of October, date of 10/10 1002: the second holiday of October, date of 10/25 1003: the third holiday of October, date of 10/31 Setting 8 holidays the most

1 0n 1 0 0 3 1 0 3 1

1: Holiday setup

0n: n-th holiday

10: Month (Oct.)

With in some month

10: Oct

31: Date (31th)

n=1~8

03: 3rd holiday of Oct

C-1. Holiday inquiry

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM--> Enter into

programming mode

Press [8]

ZONE----------

Time zone mode(F8)

Press [302 1002 1234]

XX= 1 0 2 5 = XXXX = HOL The second holiday of October, date of 10/25

Repeat the last step or press [#] to escape from the programming.

3 0n 1 0 0 2 x x x x

3: Holiday inquiry

n: n-th holiday

Don't cared digit

In specified month

n=1~8

10: Oct

02: 2 nd holiday of Oct

27

D. Bell alarm setting (F4=2801, after setting this function, the system

disables the door monitoring function automatically.)Each hour can

setup 6 alarms.

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM--> Enter into

programming mode

Press [8]

ZONE---------- Time zone mode(F8)

Press [201 0701 0750]

ZONE---------- Please refer to the following statement

Repeat the last step or press [#] to escape from the programming.

2 0n HH0n HHmm

2: Bell alarm inquiry

0n: n-th alarm schedule

Alarm time

n=1~8

HH: hour

in specified hour

0n: n-th timer in HH

D-1. Bell alarm inquiry mode (F4=2801)

Step

LCD

Description

Press[0] + master PIN [246890] PROGRAM--> Enter into

programming mode

Press [8]

ZONE---------- Time zone mode(F8)

Press [40107010000]

401=0750=0750=BEL Please refer to the following statement

Repeat the last step or press [#] to escape from the programming.

Meaning: 7:50 is the1st alarm time at 7 o'clock

4

0n

070n

0000

4: Bell alarm inquiry

0n: n-th timer The nth bell alarm

n=1~6

in 7 o'clock

Any key

28

Note:Under F4=2801,the bell alarm period is decided by 220t; meanwhile 2801 & 1101 code should mutually trade-off.(If 2801 is set,the 1101should be denied as 1100)

F9: Modify events counter for event retrieving

(Deleting events. Press"000000") Ex.Modify the Read/write counters to 00150

Step

LCD

Press[0]+masterPIN[246890] PROGRAM-->

Press[9]

CNT St-------

Press [100 150]

DON-000150

Modify read or write counter only: Modify write counter only: F9=>200150
Modify read counter only: F9=>100150 When 2 means write counter When 1 means read counter

Description Enter into programming mode Read/write counter mode(F9) Read/write counter is
6 digits INSTRUCTION

Inquiry and display the stored events

Ex.: Modify the read/write counter to 00150

Step

LCD

Press[0] + master PIN [246890] PROGRAM-->

Press[]

DSPLAY=--------

Press [50000150 ]

*DSPLAY=  

CCCCCCCC S [ NNNNNN ]

dd : Date

HH : MM Hour & Minute

cccccccc : 8 digits ID number

S :Access status

E: Error message

D: Correct stored data

NNNNN : Event counter

29

50 n n n nn n n n is the top counter To display all the record lower than the counter nnnn.
52 y y m m d dyy = year. m m = Month. d d = date. To display the record for specific date from existing counter downward.

53 w 0 0 0w = Weekday. 0 0 0 = meaningless digits. To display the record for specific weekday from existing counter downward.
After pressing 0 + (default master PIN),you could press 4 and the following function codes divided in groups for easy memory.

Group 0. 0000
0016 0018 0019 0072 0650 0750
0800 0850 0950

SYSTEM INITIALIZATION (optional) Delete all personal access map (deny all legal persons access status) -take around seconds depending on the card capacity.
Delete all time Zone data
Delete all holiday data
Delete all bell alarm data
Delete all group data Save all the modified function codes as template(could be recalled by 0950) Initialize the system in real time on-line state. (The system will be initialized as: 2101, 2203, 2306, 2501, 1500, 1600, 1100, 3200, 8600, 8700, 1700, 8902, 1900...... ) The user can use this code to initialize the system then adjust the other code to meet the requirement.
Initialize the system all parameters(include Group9) Initialize the system in off-line state ( same as 0750 except 8900) To recall the saved template.(Saved by 0650)

30

Group 1. INPUT
Disable/Enable fire alarm signal to release the door 1234/4321 automatically
Disable/Enable the door monitoring function with 1100/1101 enforce entry and door open too long .

1200/1201 Disable/Enable the security function with enforce

1500

Not compare individual personal map.

1501

Compare individual personal map.

1502

Not compare and add card by reading.

1600/1601 Not compare/ Compare personal time zone map.

1700

Immediately check APB (anti-pass back)

1800/1801 Not compare/ compare holiday.

1900/1901

Not compare/ compare project number. ( for p p p . c c c c c format only)

Group 2. OUTPUT
21tt
22tt 23tt 240n 25tt 2600/2601 2700

tt: Door release time from 01 to 97 in unit of 1 second. 2198: Setting door release time becomes minute unit, press 2198 again, door release time back to second unit. 2199: Output becomes normality, both on or off to switch.
Alarm time. tt= 00 to 98 in unit of 1 second.
tt: Door monitoring time from 01 to 98 in unit of 1 second. 2399: Setting door monitoring time becomes minute unit, press 2399 again, door monitoring time back to second unit.
Trial error alarm, n= error times.
tt:display time from 01 to 97 in unit of 1 second. Disable/ enable expiry date check (validity date programmed by PC only).
Display fix duty name by ROM.

31

2701 2702/04/08 2801 2900
2901
2902

Definable duty name by PC. 2/ 4/ 8 digit duty name. Enable bell alarm mode (Trade-off with 1101). Disable ESD function.(Optioinal)
Enable staff Nr. Display.(Trade-off with 2601,1701-1703) Enable ESD function. (Optioinal)

Group 3. OPERATION MODES

3200

Card only mode

3300

Card + PIN mode

3301

External reader needs to press PIN too(for 3300 mode)

3400

Disable 3401/3402

3401

Enable card No.+ PIN code key only mode by keying. (Press * + card No.+ PIN code)

3402

Enable door PIN mode.(Press 7 + PIN code)

3500/3501 Unlock/Lock the keypad Unlock keypad by : Press 0 for 5 seconds, after hear

beep sound press 0246890 F4=3500 to unlock keypad.

3600

Disable 3601/3602

3601

Enable duress code for card No.+PIN

3602

Enable duress code for door PIN

Note: +1 or -1 of independent pass code, the door will be unlocked

and trigger to Alarm system.

Ex.If the door pin is set up as 1234, the duress code will be 1233 or

1235.

 3700 Delete the project number by direct reading card

 370n

Record the project number by direct reading card for comparing project number (9806/9816 format only)

32

3800

Disable all following 3801, 3802, 3803 modes

3801

Enable free access modes

3802

Enable auto duty (shift) code mode

3803

Enable automatic operation mode

Only one mode among 3801, 3802, 3803 is allowed

3900/ 3901 Disable/ Enable Anti-passback mode

Group 4. DOOR OR MASTER PIN SETTING

460

Set the master PIN for Pongee APP system.

4601~4607 Set the 4 digits door PIN (Under F4=3402)

4609

Set the 6 digits master PIN for system login.

4610~4699 Adding 90 codes 4 digits door PIN (Under F4=3402)

4700

Clear all PINs

4710~4799 Delete the corresponding PIN

Group 5. CARD INQUIRY

5333

Inquiry card status by reading card ( learning mode)

5500

Inquiry card status for block ragne

Group 6. TIME ZONES OR FLOORS SETTING MODE/ADDING

CARD BY LEARING OR BLOCK RANGE

62nn

Setting time zone for group (nn=01~99,)(Under

F=1601)(P.17)

Note:Please delete all group data for first time setting group.

(F4=0072)

6333

Add single card reading learning mode(P.17)

66nn

Add card with block mode(P.17)

Group 7. 72nn 7333 77nn

CARD DELETING Delete time zone from group nn(nn=01~99) (P.17) Delete single card with auto learning mode (P.17) Delete card with block mode(P.17)

33

Group 8. SYSTEM CONFIGURATIONS

8300/830t Not check repeat reading/ Present repeat reading

within t minutes. (t=1~9 minutes)

840X

8400 Non-store the error even

8401 Store the error event

8402 Store the event of exit push button

8403 Store the event of error and exit push button

8599 Send out all personal map (for PC on-line test only) by

test com

86FS

Serial output

F(floor)

S(serial output)

S=0 Disable output

F=0

Without lift output (for access only)

S=1 RS-232 output S=2 RS-485 output

86 FS=10 Support 8 floor

S=3 RS-232/RS-485 output

FS=23 Support 24 floor

FS=33 Support 48 floor ~64 floor

FS=91 Support 96 floor output(without time zone

8700
8701 88aa 890n

function)(optional)
Access records save as FIFO(first-in-first-out) When the data is full, it should be cleared manually or collect by PC. Otherwise reader can not save new recodes Automatically save records base on FIFO. When the data is full, the oldest record will be automatically overwritten.
Set device address as aa for polling. If n=0, the system is off-line (batch mode) If n=3, the system is on-line (real-time mode), if not necessary, we suggest 8900 to shorten the access response time

34

Group 9. FACTORY CONFIGURATION

92nn

nn=00~31the modification factor as the RTC is fast nn=32~63 the modification factor as the RTC is slow Example: as the crystal is faster than 2Hz, then the factor is 21(F4=9221)

9311

Enable Bluetooth function.(Optional)

9600/9601 Disable/ enable name display

970N

Select the card digits as group index for comparing.

Card number

12345678

9700

9701

9702

9703

9704

9705

Need to set F4 = 9705 on the PN/Q/M1/M8 format Need to set F4 = 9704 on the M0 format (Default F4=9704)

9781

Reverse the Wiegand number for decoding (New version firmware)

98pd

To define the card display format

P=Format

d=Card format

P=0 PN format d=3 p p p . c c c c c, 26bit(3P5C)

P=1 PP format d=5 000CCCCC, 35bit, HC

P=2 PN format d=6 000CCCCC, 26bit

P=3 PP format d=8 C1C2C3C4C5C6C7C8, 34 bit

Ex.F4=9803 PN format, p p p . c c c c c, 26bit(3P5C)

9870 / 9870 Mute / Turn on the sound when timing or program

setting by software

Baud rate (factory default 9996=9,600BPS) :

9996

9,600 bps

9948

4,800 bps

35

9924

2,400 bps

Ordered before shipping (due to need to change crystal) :

9919

19,200 bps

9938

38,400 bps

9891

10 digits card number

 : Optional

Simple and easly trouble shooting

Questions concerning the card reader

#Symptom 01: The reader can not read card and get access

A.1--To check whether the proximity card is encoded correctly. Either

correct project number or card type. .

A.2--To check whether the proximity card is legal.

A.3--To check if the personal ID is enrolled in the reader by function

F6 of card adding.

#Symptom 02: The reader can read card but can not get access

A.1--To check if the reader is at 3300 mode (card with code),the reader

lit green LED at left and you do not key-in the PIN within the

keypad waiting time.

A.2--To check if the reader is at 830t mode (unauthorized repeat card

within t minutes), if yes, you should try to get access after t

minutes. If 830t isn't the mode you want, then you may change it

to 8300 code.

#Symptom 03: The reader can get access (LED displayed good or

LCD displayed ---O.K.---, but the door was not

released.

A.1--To check if you correctly wire the electrical lock device with the

correct power supply.

A.2--If the devices are all correctly wired and the wire is well

conducted, then hear if the relay is clicked. If yes, then the relay

contacts may be damaged. If not click, then the relay driver in the

circuit board may be bad or damaged. Please contact with the

distributor for repair or replacement.

 Wrong message on LCD display:

C.ERR ­Illegal card no.

A.ERR ­Anti-pass back error

36

Z. ERR ­Time zone error P. ERR ­ Password error Q. ERR ­Project no. error V. ERR ­Out of validity date RPT.ER­Unable to read card repeatedly during the set time by parameter code 830t
#Symptom 04: The door was released but the duration is very short A.1--If the door released period is not so long as you set by 21tt,then please check if the door monitoring mode (1100/1)is set as 1101 mode and the door monitoring sensor doesn't normal closed as the door is held. In such condition, the door release driver will shut off the relay driver once it found the door is opened because the door sensor is left opened. Therefore, please replace the sensor or set the door monitoring mode as 1100 (not monitoring) before you replace the sensor. A.2--If the door released period is not so long as you set by 21tt, but you have already disabled the door monitoring function by 1100 or although you actuate the door monitoring by code 1101, but the door sensor works normally, then this phoenomena is resulted from the EMI interference from the drivered electrical device usually. If the coil of the door actuator or the external relay doesn't well protected by a reversed polarity free wheeling diode to suppress the interference for DC voltage driver or a surge absorber for AC voltage driver, the voltage transient pulse will let theCPU hold down or run into disorder or automatic reset and therefore shorten the door released time to around one second. #Symptom 05: The counter can't be set by F9 counter setting A.1--At first, if the address 880n is properly set. If the system address isn't properly set (Can be checked by 0 key) or is disturbed, then the reader won't store the event counter.
Questions concerning the card reader and its on-lined controller (Any brand of PC or other dedicate controller)
#Symptom 01: The Personal Computer can not collect the data string from the reader(s) by standard software package.
A.1--At first, for on-lined application, the installer should ultilize the terminal simulation software package such as TELEX,BITCOM etc. to test whether the wiring between the PC (and the Multi-channel controller PCP-832-xx or the RS-422/RS-232C converter or other 3rd partners interfacing devices for networking)
37

and the readers are well connected and the communication parameters are selected correctly. At the same time, each reader should be set the correct parameters, unique reader address for each reader at the same wire cable for address mode by 88nn, 890n or 8900 for batch type or 890t for real time type..., etc. The reader address can definitely not be set the same for any two readers.The installer should be able to judge whether the wiring is correct and solid reliable by viewing the terminal response from each reader. A.2--If the supported PC standard software package for polling mode and through the multi-channel controller PCP-832-xx can set the system time and date, but cannot collect the stored or immediate data, then please check if the Data Terminal Ready (PIN G) is correctly connected with PIN 4 (Non-inverted Data Terminal Ready). At polling mode, if the real time data is ready or the buffer is not empty, then the PIN G should be at low voltage level less than 2.5 VDC. If at above condition but the voltage level is higher than 2.5 VDC at any side, please check if the wiring is correct. #Symptom 02: The Personal Computer can not collect the data string through the linking driver in Clipper A.1--Please check if the parameters of on-line (Such as 88aa and 890t of F4) are well programmed. A.2--Please check if the reader is connected at COMM1. A.3--Please check if EMM386.EXE in file of CONFIG.SYS is remarked and whether FILE/BUFFERS is opened as stipulated as rem device=C:\windows\EMM386 I=e000-efff noems A.4--Check whether the delay time in software is matched with executing time in the reader. Please adjust the delay time.