Installation Guide for xpr models including: B100-SA Standalone Biometric Reader, B100-SA, Standalone Biometric Reader, Biometric Reader, Reader

Download

B100-SA - XPR Group


File Info : application/pdf, 12 Pages, 2.19MB

PDF preview unavailable. Download the PDF instead.

B100-SA-v2 EN Rev.-1.01
B100-SA v2

EN
Standalone Biometric Reader

INSTALLER'S MANUAL

www.xprgroup.com

1 Rev. 1.01 - 31.03.2022

CONTENTS

1. INTRODUCTION

3

2. MOUNTING

3

3. SPECIFICATIONS

4

4. APPLICATION DIAGRAM

4

5. RECOMMENDED SWIPING TECHNIQUE

4

6. INDICATION

4

7. WIRING

5

8. ADDING ADMIN FINGER

5

9. PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT

6

Pairing B100-SA v2 with DINRTT

6

Pairing B100-SA v2 with RTT

6

Pairing B100-SA v2 with RU2

6

10. ADMINISTRATOR PROGRAMMING

7

ADD finger relay 1

7

ADD finger relay 2

7

ADD finger relay 1&2

7

DELETE finger

7

DELETE ALL fingers

8

CHANGE ADMIN finger

8

CHANGE INSTALLER finger

8

Administrator programming block diagram

9

11. INSTALLER PROGRAMMING

10

Set relay 1 time

10

Set relay 2 time

10

BUZZER ON/OFF

10

BACKLIGHT ON/OFF

10

Installer programming block diagram

11

www.xprgroup.com

2

1. INTRODUCTION
B100-SA v2 is access control fingerprint reader designed for easy management of the users and configuration. The scanner is made with advanced capacitive sensing technology that provides some advantages over optical solutions like: - making almost impossible to make fake copy of the users fingers - same performance in the different light conditions - good reading of fingers with stains from daily jobs Built in strong scanning and matching algorithm provides excellent tolerance in the way finger is swiped over the sensor reducing to minimum the need to repeat finger swiping at the sensor. The reader can store up to 100 finger templates. One template is reserved for User manager (Administrator), one template is reserved for Reader configuration (Installer) and up to 98 templates are for Users.
RECOMMENDATIONS
Consult with installer about safety level of the installation. There are devices with relays compatible with this reader that can increase the security of the system if needed. One or two enrolled fingers are enough for one user. Ask the installer before he leaves the site to enroll your finger as administrator.
NOTES
The Reader is using physical roughness of the fingerprint to scan the finger. Some of the users may have very flat fingertips, making difficult for the sensor to recognize correctly the fingerprint. In most cases, these are children and older persons. To solve this problem, do the following: 1. Try with different user's fingers to find the "best" finger. 2. Check with the installer other models of the reader with added card reader or keypad for other type of access.
MAINTENANCE
No special or periodic maintenance is required. If cleaning is needed, use soft wet cloth and wipe gently the dirt. Do not use chemicals and materials that can scratch the sensor.
WARNING!
Do not touch the sensor with other objects than finger. Do not pour or splash with water or other liquids. When painting or construction work is ongoing in the area around the reader, protect the reader sensor area from possible damages and paint. If reader is to be dismounted or relocated, call authorized installer for the job. Disposal of this product must be handled according to all national laws and regulations.
2. MOUNTING
Do not install the device and cabling close to a source of strong electro-magnetic fields like radio-transmitting antenna. Do not place the device near or above heating equipments. If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel. Do not let children touch the device without supervision. Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can't be entered. The operating temperature of the product is between 0ºC - + 50ºC. XPRTM cannot guarantee the functionality of the product if measures and advice before are not followed.

www.xprgroup.com

3

3. SPECIFICATIONS
Fingerprint Capacity: Output: Push Button Input: Panel Connection: Door Open Time: Entry Mode: Programming: Admin/Installer Fingers: Backlight ON/OFF: Buzzer ON/OFF: Firmware upgrade: Current Consumption: Power Supply: Indication: IP Factor: Operating Temperature: Operating Humidity: Dimensions(mm):

98 templates 1 x Relay (2 A /24V AC/DC) Yes Cable, 0.5 m Pulse (1 to 30 seconds) or Toggle (ON/OFF) Finger By swiping 1 Administrator and 1 Installer Finger Yes Yes via RS-485 converter and windows application 100 mA max. 9-14 V DC Tricolor Status LED IP54 (internal use only) 0°C to +50°C 5% to 95% RH without condensation 92 x 51 x 25 (metal); 92 x 51 x 27 (ABS)

4. APPLICATION DIAGRAM

Unsecured Area
5. RECOMMENDED SWIPING TECHNIQUE
Follow the below instructions for correct finger swiping. Starting from the first finger joint, place the selected finger on the swipe sensor and move it evenly towards oneself in one steady movement. Result: For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep) For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps)
6. INDICATION

www.xprgroup.com

4

7. WIRING

8. ADDING ADMIN FINGER

1.Push dip switch no.2 in position ON. 2.Reset the Power of the device. 3.Wait for One long + multiple short beeps 4.Put the dip switch in position OFF. (short beeps will stop) 5.Wait for about 15 seconds for the LED to blink in Orange. 6.Swipe the Master finger min.6 times. (Until Ok Beep)

Warning: This procedure also deletes all the users and the installer finger. Warning: This procedure will unpair the connected relay unit (RTT, DINRTT or RU2)

www.xprgroup.com

5

9. PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also can play the role of request-to-exit push button. Follow the instructions bellow to pair (couple) both devices or refer to the Remote Relay's Manual.
Pairing B100-SA v2 with DINRTT
1. Close the Jumper. DINRTT beeps continuously and the red led blinks.
2. Open the Jumper 3. Wait for Beep + OK Beep (short + short + long beep) After the OK beep, the coupling is done.

Pairing B100-SA v2 with RTT

1. Put Dipswitch No.1 to position ON. RTT beeps continuously and the red led blinks.
2. Put Dipswitch No.1 to position OFF.
3. Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.

Pairing DINB100-SA with RU2

1. Put the Jumper to closed position. RU2 beeps continuously and the red led blinks.
2. Put the Jumper to open position.
3. Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.

Warning: Changing the ADMIN finger will also unpair the remote relay unit.

www.xprgroup.com

6

10. ADMINISTRATOR PROGRAMMING
Use point fingers as Administrator and Installer. You can use the other fingers as access fingers. Administrator finger is enrolled at the end of the system installation. Initial enrollment of the Admin finger is described in installer manual.

ADD Finger Relay 1 (Finger that will activate relay 1)

Action Swipe Admin Finger 1 time
Wait 5 seconds (until fast blinking) Swipe User Finger min. 6 times (until short + long beep)

Finger x 1
x 6

Backlight slow blinking
fast blinking

Buzzer Sound short beep
short beep short + long beep

ADD Finger Relay 2 (Finger that will activate relay 2)

Action

Finger

Backlight

Buzzer Sound

Swipe Admin Finger 2 times x 2
Wait 5 seconds (until fast blinking)

slow blinking

short beep short beep

Swipe User Finger min. 6 times

(until short + long beep)

x 6

fast blinking

short + long beep

Relay 2 is available if the reader is used with remote relay unit with 2 relays (DINRTT and RU2). Consult the installer if Relay 2 is available in your system.

ADD Finger Relay 1&2 (Finger that will activate relay 1&2)

Action Swipe Admin Finger 3 times
Wait 5 seconds (until fast blinking) Swipe User Finger min. 6 times (until short + long beep)

Finger x 3
x 6

Backlight slow blinking
fast blinking

Buzzer Sound short beep
short beep short + long beep

Relay 2 is available if the reader is used with remote relay unit with 2 relays (DINRTT and RU2). Consult the installer if Relay 2 is available in your system.

DELETE Finger
Action Swipe Admin Finger 4 times Wait 5 seconds (until fast blinking)
Swipe User Finger

Finger x 4
x1

Backlight slow blinking
fast blinking

Buzzer Sound short beep
short beep short + long beep

www.xprgroup.com

7

DELETE ALL Fingers
Action Swipe Admin Finger 4 times Wait 5 seconds (until fast blinking) Swipe Admin Finger 2 times

Finger x 4
x2

CHANGE ADMIN Finger

Action Swipe Admin Finger 5 times
Wait 5 seconds (until fast blinking) Swipe NEW Admin Finger min.6 times

Finger x 5
x6

CHANGE/Enroll INSTALLER Finger

Action Swipe Admin Finger 6 times
Wait 5 seconds (until fast blinking) Swipe NEW Installer Finger min.6 times

Finger x 6
x6

Backlight slow blinking slow blinking fast blinking
Backlight slow blinking slow blinking fast blinking
Backlight slow blinking slow blinking fast blinking

Administrator Programming block diagram
Swipe the ADMIN Finger 1 to 6 times depending of the desired menu

Buzzer Sound short beep short beep
multiple beeps
Buzzer Sound short beep short beep
short + long beep
Buzzer Sound short beep
short + long beep 3 short beeps

www.xprgroup.com

8

11. INSTALLER PROGRAMMING

Set Relay 1 Time (on board)
Action Swipe Installer Finger 1 time
Wait 5 seconds (until fast blinking) Swipe the INSTALLER Finger and start counting seconds Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in toggle mode

Finger x1
x1 x1

Backlight slow blinking
fast blinking fast blinking

Buzzer Sound short beep short beep
beeps on 1 second
short + long beep

Set Relay 2 Time (remote)

Action

Finger

Backlight

Buzzer Sound

Swipe Installer Finger 2 times x2
Wait 5 seconds (until fast blinking)

Swipe the INSTALLER Finger

and start counting seconds

x1

Swipe the INSTALLER Finger

to stop or wait 30 seconds to

x1

put the relay in toggle mode

slow blinking fast blinking fast blinking

short beep short beep beeps on 1 second
short + long beep

Relay 2 is available if the reader is used with remote relay unit with 2 relays (DINRTT and RU2). Consult the installer if Relay 2 is available in your system.

BUZZER ON/OFF
Action Swipe Installer Finger 3 times Wait 5 seconds (until fast blinking)
Swipe Installer Finger

Finger x3
x1

Backlight slow blinking
fast blinking

Buzzer Sound short beep
short beep short + long beep

BACKLIGHT ON/OFF
Action Swipe Installer Finger 4 times Wait 5 seconds (until fast blinking)
Swipe Installer Finger

Finger x4
x1

Backlight slow blinking
fast blinking

Buzzer Sound short beep
short beep short + long beep

www.xprgroup.com

9

Installer Programming block diagram
Swipe the Installer Finger 1 to 4 times depending of the desired menu

www.xprgroup.com

10

www.xprgroup.com

11

This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.

www.xprgroup.com

12



References