Installation Guide for Honeywell models including: Y6H920RW5031, T6 Smart Thermostat, Y6H920RW5031 T6 Smart Thermostat
The T6 thermostat should not be placed near draughts, in direct sunlight or near ... T6 Smart Thermostat EN Installation Manual 32308180-001 F. Set Up and 6 configuration Wiring Diagrams A) Wiring for basic 230V boiler ... The Honeywell Home trademark is used under license from Honeywell International Inc.
1 and remove the old thermostat 4 Complete 5 installation Prepare Receiver Box 2 for installation Install the 3 Receiver Box T T T T S S A) B) B) Surface wiring C) Replace the cover Connect 2 thermostat wires to the T and T terminals and close cover. Remember to use the same wires that you connected to the Receiver Box when connecting to the ...
File Info : application/pdf, 2 Pages, 2.16MB
DocumentDocumentT6 Smart Thermostat EN Installation Manual Compatible with 24-230V on/off and OpenTherm® appliances such as gas boilers, combi-boilers and heat pump. Also works with zone valve applications but not with electric heating (240V). 1 Turn OFF the power and remove the old thermostat To ensure your safety, always make sure mains power is switched OFF before accessing wiring. Before removing the old thermostat take a picture of the old thermostat's wiring as reference then proceed to installation. Need help? For assistance please visit: getconnected.honeywellhome.com 200 Berkshire Place, Winnersh Triangle Berkshire RG41 5RD Phone: 0300 130 1299 Approvals Hereby, Pittway Sarl declares that the radio equipment type T6H700RW is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://hwllhome.co/DoC Wi-Fi (2.4GHz): Max Power 100mW, 2.42.458GHz ErP: Class V (+3%), (EU) 811/2013 Must be installed by a competent person! Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. 1.2-1.5 m The T6 thermostat should not be placed near draughts, in direct sunlight or near heat sources. It should be at least 1.2 - 1.5 meters from the floor. Maximum cable length between Receiver box and thermostat: 15m for 0.5mm² cable or 20m for 1.0mm² cable. WEEE Directive 2012/19/EC Waste Electrical and Electronic Equipment directive At the end of the product life dispose of the packaging and product in a corresponding recycling centre. Do not dispose of the unit with the usual domestic refuse. Do not burn the product. 2 Prepare Receiver Box for installation Before installation of the Receiver Box Find a suitable location near to the boiler. Loosen the front screw to remove cover or tighten it when the cover is back in place. Needed during installation: Cable with 2 wires from the Receiver Box (R4H810A) to thermostat. Cable with 2 wires from the boiler to Receiver Box. The Receiver Box requires 230V power 3 Install the Receiver Box Please refer to the wiring diagrams over the page A) Wall box or Rear Wiring Hinge open the terminal block flap to access the cables and wall box screw holes. B) Surface wiring Use the cable clamps to secure the surface wiring. Max 6 mm min 0.25mm2 max 1.5mm2 C) Replace the cover Locate the hinges at the top of the cover and wall plate, close the cover and secure with the screw. 4 Install the T6 thermostat Remember to use the same wires that you connected to the Receiver Box when connecting to the thermostat. A) Using a screwdriver open wallplate terminal cover to connect wires 5 Complete installation Turn ON mains power to the Heating Appliance and Receiver Box. T T Optional Coverplate installation B) Connect 2 thermostat wires to the T and T terminals and close cover. T ST S C) Attach the thermostat to the wallplate when finished. After powering up both devices the green LED is on. Push the button to check if the boiler switches on. Button lights green. After power up, SETUP is displayed on the thermostat's screen. 32308180-001 F 6 Set Up and configuration ***SETUP**** SETUP **LANGUAGE** 1) Touch to begin setting up the thermostat. 2) Select your language. SETUP *CLOCK SETUP CONFIGURE W 3) Set the clock format, time and date. 4) Touch to finalise setup. ( to setup using the App is currently unsupported) Wiring Diagrams A) Wiring for basic 230V boiler Receiver Box Thermostat ss Boiler Once setup is completed, if you need to change more settings go to the advanced menu. To access the advanced menu press for 5 seconds. *1234APMM AM PM *** **2 30* ** *AM PM 1 23456 In the advanced menu the following settings can be adjusted: 5 sec Menu Item LANGUAGE OPENTHERM CYCLE RATE MINIMUM ON TIME HEAT RANGE SCHEDULE OPTIONS EXTERNAL SENSOR OPTIMISE CLOCK LOW LOAD CONTROL TEMPERATURE OFFSET RESET FAILSAFE Default English - 6 1 minute Min = 5.0ºC Max = 35.0ºC Daily No sensor Opt. start OFF Opt. stop OFF Format: 24h Time: --:-Date: 01/09/16 ON 0.0ºC OFF Options 0 = English, 1 = Français, 2 = Español 3 = Deutsch, 4 = Nederlands, 5 = Italiano OpenTherm boiler data when available 3, 6, 9 or 12 1, 2, 3, 4 or 5 minutes Min: 5ºC to 21ºC, Max: 21ºC to 35ºC 1 = Daily schedule, 2 = 5+2 days schedule 0 = No sensor, 1 = Room sensor Opt. start: 0 = OFF, 1 = ON, 2 = Delayed start Opt. stop: 0 = OFF, 1 = ON Clock format: 1 = 12h, 2 = 24h Setup time and date 0 = OFF, 1 = ON 1.5 ºC to 1.5ºC Factory, schedule, WiFi and HomeKit reset 0 = OFF, 1 = ON B) Wiring for Combi boiler Receiver Box Lyric T1 T2 Boiler* Thermostat ss C) Wiring for OpenTherm boiler Receiver Box Thermostat ss D) Wiring for two-port zone valve Receiver Box Thermostat ss T1 T2 Boiler* V4043 For other wiring diagrams visit: * See boiler specifications for correct terminals https://hwllhome.co/uk-wiring Pittway Sarl, Z.A. La Pièce 4 1180 Rolle, Switzerland Country of origin : UK © 2020 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International Inc. This product is manufactured by Resideo and its affiliates.