EK Blinder III C User Manual
Safety
General Instruction
- The products referred to in this manual conform to the European Community Directives and are therefore marked with CE.
- The unit is supplied with hazardous network voltage (230V~). Leave servicing to skilled personnel only.
- Never make any modifications on the unit not described in this instruction manual, otherwise you will risk an electric shock.
- Connection must be made to a power supply system fitted with efficient earthing (Class I appliance according to standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the units from indirect contact and/or shorting to earth by using appropriately sized residual current devices.
- The connection to the main network of electric distribution must be carried out by a qualified electrical installer. Check that the main frequency and voltage correspond to those for which the unit is designed as given on the electrical data label.
- This unit is not for home use, only professional applications.
- Never use the fixture under the following conditions:
- in places subject to vibrations or bumps;
- in places with a temperature of over 40 °C.
- Make certain that no inflammable liquids, water or metal objects enter the fixture.
- Do not dismantle or modify the fixture.
- All work must always be carried out by qualified technical personnel. Contact the nearest sales point for an inspection or contact the manufacturer directly.
- If the unit is to be put out of operation definitively, take it to a local recycling plant for a disposal which is not harmful to the environment.
Warnings and installation precautions
- If this device will be operated in any way different to the one described in this manual, it may suffer damage and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short circuit, burns, electric shock, etc.
- Before starting any maintenance work or cleaning the projector, cut off power from the main supply.
- Always additionally secure the projector with the safety rope. When carrying out any work, always comply scrupulously with all the regulations (particularly regarding safety) currently in force in the country in which the fixture's being used.
- Install the fixture in a well ventilated place.
- Keep any inflammable material at a safe distance from the fixture.
- Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired.
- The lamp (LED) shall be changed if it has become damaged or thermally deformed.
- Never look directly at the light beam. Please note that fast changes in lighting, e.g. flashing light, may trigger epileptic seizures in photosensitive persons or persons with epilepsy.
- Do not touch the product's housing when operating because it may be very hot.
Introduction
FEATURES
- 380W RGBA +90W WW LED
- 2800-10000K Variable color temperature
- Ra≥90, R9≥90
- Fan-free design and quiet operation suitable for studio use
- Selectable PWM frequency for flicker-free video with any camera
- 4 dimming curves with 16-bit control for smooth dimming
- Consistent color temperature throughout the dimming curve
- Built-in macros make for easy programming of stunning effects
- Compact body and light weight
SPECIFICATIONS
- Light Source: 380W RGBA, WW:90W LED
- Color Temperature: variable 2800-10000K, W:3148
- Luminous flux: 6020lm
- CRI≥90
- Beam Angle: 59.3°
- Filed Angle: 100°
- Tilt: 360°
- Strobe: 0-30Hz
- Dimmer: 4 dimming curves
- Mains: 100-240V, 50-60Hz, 122W
- Protocol: DMX512, RDM
- Power connection: PowerCorn in/out, linking up to 21pcs
- DMX connection: DMX in/out, linking up to 32pcs
- DMX Channel: 1CH/5CH/7CH/10ch1/10ch2/12CH/13CH/15CH/28CH
- IP Grade: IP20
- Ambient: 0-40°C
- Physical Dimensions: 415*93.7*231.7mm
- Weight: 3.7kg
Dimension
The following diagram illustrates the dimensions of the EK Blinder III C:
Width: 380 mm
Depth: 93.7 mm
Height: 183.5 mm
Overall Height with mounting bracket: 231.7 mm
Mounting hole diameter: Φ13 mm
Overview
The EK Blinder III C features the following components:
- 1. LCD Display
- 2. Fuse
- 3. Power In
- 4. Power Out
- 5. DMX In
- 6. DMX Out
Basic Functions and Operation
UP | DOWN | MODE | ENTER |
Increase the displayed value, or scroll thru previous menu items | Decrease the displayed value, or scroll thru next menu items | Display main menu, or return to higher menu levels | Confirm displayed values, or activate displayed functions, or enter submenus, or save settings |
Startup initialization: Left and right keys.
Shortcut: When on the main interface, press and hold up and down buttons for 3 seconds to display in reverse.
Battery display: When there is no external power supply, long press and hold the right button for 3 seconds to enter the setting menu parameters.
Photometrics
Beam Angle: 59.3°
The following table shows the illuminance and beam diameter at different distances:
Distance (M) | 3 | 5 | 10 | 15 | 20 |
Illuminance (lux) | 591 | 213 | 53 | 24 | 13 |
Diameter (M) | 3.42 | 5.69 | 11.39 | 17.08 | 22.78 |
Power Connection
The EK Blinder III C can be linked together for power. Up to 21 units can be connected in series.
Diagram showing three units connected in a daisy-chain for power.
DMX Connection
The EK Blinder III C can be controlled via DMX512. Up to 32 units can be linked in series for DMX control.
Diagram showing three units connected in a daisy-chain for DMX signal.
DMX MODE
DMX MODE | 1st Fixture | 2nd Fixture | 3rd Fixture | 4th Fixture |
1 channel | 001 | 002 | 003 | 004 |
3 channels | 001 | 004 | 007 | 010 |
Installation
Notice
- This product is only suitable for indoor use, with a protection level of IP20. The lighting fixtures should be kept clean and avoid use in damp or dusty environments.
- Maintenance should be carried out every three months.
- Qualified professionals are only allowed to install, operate, and maintain lighting fixtures, and ensure strict adherence to the procedures described in this manual.
- The lighting fixtures should be installed in a well ventilated area, at least 50CM away from the wall, and the ventilation holes should be checked for smoothness. Do not look directly at the light source to avoid damage to the eyes.
- The electrical connections must be operated by qualified installation personnel.
- Each lamp should be securely grounded and electrically installed in accordance with relevant standards.
- Do not use power cords with damaged insulation layer, and do not place the power cord on other wires. When the lamp is not in use or clean, please unplug the power cord and do not forcefully plug or drag the power cord directly.
- If the back cover of the lamp is equipped with a safety buckle or connection hole, for safety reasons, please use a safety rope to penetrate the connection hole for auxiliary lifting.
Diagram showing multiple fixtures mounted on a truss structure.
Diagram showing a close-up of a mounting bracket and safety rope attachment point.
Menu
The EK Blinder III C features a comprehensive menu system for controlling various parameters. The following tables detail the menu structure and options:
Blinder2-C Menu
NO. | Main Menu | Menu level 2 | Menu level 3 | Menu level 4 | Default |
1 | DMX Address <001> | Default: 001 | |||
2 | DMX Channel | 1Ch | Virtual Color Wheel | RGBAW=255 | |
3Ch | Color Temperature | Default: 12CH | |||
5Ch | Manual Color Mixer | ||||
7Ch | C3050-Md Yellow | ||||
10Ch1 | C3040-Lt Yellow | ||||
10Ch2 | C3240-Amb Yellow | ||||
12Ch | C2340-VLt Amber | ||||
13Ch | C2040-Lt Amber | ||||
15Ch | C2050-Md Amber | ||||
28Ch | C2060-Dk Amber | ||||
3 | Virtual Color Wheel | HSV | C1050-Lt Red | Dimmer<0-255> | Default: C3050-Md Yellow, Dimmer=255 |
C1080-Md Red | |||||
C1020-NC Pink | |||||
C1030-Md Pink | |||||
C1630-Dk Pink | |||||
C1250-Md Red Amber | |||||
C1060-Dk Red Amber | |||||
C1650-Magenta | |||||
C6170-Dk Magenta | |||||
C6020-Lt Lavender | |||||
C5030-Lt Blue | |||||
C5020-VLt Blue | |||||
C5430-Lt Blue2 | |||||
C5070-Blue | |||||
C5050-Md Blue | |||||
C5060-Dk Blue | |||||
C5690-Indigo | |||||
C5080-VDk Blue | |||||
C5081-VdK Blue2 | |||||
C4370-Yel Green | |||||
C4070-Green | |||||
C4550-Turquoise | |||||
C4560-Aqua | |||||
C4570-Blue Green | |||||
Color Temperature | 3200K | Dimmer<0-255> | Default: 3200K, Dimmer=255 | ||
2800K | |||||
3000K | |||||
3500K | |||||
4000K | |||||
4500K | |||||
5000K | |||||
5600K | |||||
6000K | |||||
6500K | |||||
7000K | |||||
7500K | |||||
8000K | |||||
8500K | |||||
9000K | |||||
9500K | |||||
10000K | |||||
Manual Color Mixer | Red | <0-255> | Default: RGBAW=255 | ||
Green | <0-255> | ||||
Blue | <0-255> | ||||
Amber | <0-255> | ||||
White | <0-255> | ||||
Off | |||||
4 | Auto Show | Color X-Fade Speed | X-Fade Speed 1 | Default: X-Fade Speed 1 | |
X-Fade Speed 2 | |||||
X-Fade Speed 3 | |||||
X-Fade Speed 4 | |||||
Auto 1 | <1-100> | Default: Auto 1;Speed:100 | |||
Auto 2 | <1-100> | ||||
Auto 3 | <1-100> | ||||
Auto 4 | <1-100> | ||||
Auto 5 | <1-100> | ||||
Auto 6 | <1-100> | ||||
5 | Red Shift | On | Default: On | ||
Off | |||||
6 | Master/Slave | Master | Default: Slave | ||
Slave | |||||
7 | Dimmer Curve | S-Curve | Default: Linear | ||
Linear | |||||
Square | |||||
Inverse Square | |||||
8 | Dimmer Mode | Off | Default: Off | ||
Dimmer 1 | |||||
Dimmer 2 | |||||
Dimmer 3 | |||||
9 | White Balance | Manual | Red 1 | <125- | Default: RGBAW=255 |
Green 1 | <125- | ||||
Blue 1 | <125- | ||||
Amber 1 | <125- | ||||
White 1 | <125- | ||||
Red 2 | <125- | ||||
Green 2 | <125- | ||||
Blue 2 | <125- | ||||
Amber 2 | <125- | ||||
White 2 | <125- | ||||
10 | LED Frequency | 600Hz | Default: 1200Hz | ||
1200 Hz | |||||
2000 Hz | |||||
4000 Hz | |||||
6000 Hz | |||||
25KHz | |||||
11 | Flip Display | No | Default: No | ||
Yes | |||||
12 | Back Light | 10S | Default: 2min | ||
30S | |||||
2min | |||||
Always On | |||||
13 | Key Lock | On | Default: On | ||
Off | |||||
14 | Information | Fixture Hours | <65000> | ||
LED Hours | <65000> | ||||
Versions | <Vx.xx> | ||||
UID | ******* | ||||
15 | Temperature | <LED1: 40°C> | |||
<LED2: 40°C> | |||||
16 | Factory Reset | No | |||
Yes |
DMX Chart
The following tables detail the DMX channel assignments and functions for the EK Blinder III C.
Blinder2-C DMX Channel
Function | Value | Percent/Setting | ||
1-CH | Dimmer | 000-255 | 0~100% | |
3CH | Dimmer | 000-255 | 0~100% | |
000-005 | No Function | |||
006-013 | C3050-Md Yellow | |||
014-021 | C3040-Lt Yellow | |||
022-028 | C3240-Amb Yellow | |||
029-035 | C2340-VLt Amber | |||
036-043 | C2040-Lt Amber | |||
044-051 | C2050-Md Amber | |||
052-059 | C2060-Dk Amber | |||
060-067 | C1050-Lt Red | |||
068-075 | C1080-Md Red | |||
076-083 | C1020-NC Pink | |||
084-091 | C1030-Md Pink | |||
092-099 | C1630-Dk Pink | |||
100-107 | C1250-Md Red Amber | |||
108-115 | C1060-Dk Red Amber | |||
116-121 | C1650-Magenta | |||
122-130 | C6170-Dk Magenta | |||
131-138 | C6020-Lt Lavender | |||
139-146 | C5030-Lt Blue | |||
147-154 | C5020-VLt Blue | |||
155-162 | C5430-Lt Blue2 | |||
163-170 | C5070-Blue | |||
171-178 | C5050-Md Blue | |||
179-186 | C5060-Dk Blue | |||
187-194 | C5690-Indigo | |||
195-202 | C5080-VDk Blue | |||
203-210 | C5081-VdK Blue2 | |||
211-218 | C4370-Yel Green | |||
219-226 | C4070-Green | |||
227-234 | C4550-Turquoise | |||
235-242 | C4560-Aqua | |||
243-250 | C4570-Blue Green | |||
251-255 | No Function | |||
2 | Color Macro | |||
3 | Color Temperature | 000-005 | No Function | |
006-019 | 2800K | |||
020-033 | 3000K | |||
034-047 | 3200K | |||
048-061 | 3500K | |||
062-075 | 4000K | |||
076-089 | 4500K | |||
090-103 | 5000K | |||
104-117 | 5600K | |||
118-131 | 6000K | |||
132-145 | 6500K | |||
146-159 | 7000K | |||
160-173 | 7500K | |||
174-187 | 8000K | |||
188-201 | 8500K | |||
202-215 | 9000K | |||
216-229 | 9500K | |||
230-243 | 10000K | |||
244-055 | No Function | |||
5CH | Function | Value | Percent/Setting | |
1 | Red | 000-255 | 0~100% | |
2 | Green | 000-255 | 0~100% | |
3 | Blue | 000-255 | 0~100% | |
4 | Amber | 000-255 | 0~100% | |
5 | White | 000-255 | 0~100% | |
7CH | Function | Value | Percent/Setting | |
1 | Dimmer | 000-255 | 0~100% | |
2 | Red | 000-255 | 0~100% | |
3 | Green | 000-255 | 0~100% | |
4 | Blue | 000-255 | 0~100% | |
5 | Amber | 000-255 | 0~100% | |
6 | White | 000-255 | 0~100% | |
7 | Strobe | 000-010 | NO Function | |
011-255 | Strobe Slow to Fast | |||
10CH1 | Function | Value | Percent/Setting | |
1 | Red1 | 000-255 | 0~100% | |
2 | Green1 | 000-255 | 0~100% | |
3 | Blue 1 | 000-255 | 0~100% | |
4 | Amber1 | 000-255 | 0~100% | |
5 | White 1 | 000-255 | 0~100% | |
6 | Red2 | 000-255 | 0~100% | |
7 | Green2 | 000-255 | 0~100% | |
8 | Blue2 | 000-255 | 0~100% | |
9 | Amber2 | 000-255 | 0~100% | |
10 | White2 | 000-255 | 0~100% | |
10CH2 | Function | Value | Percent/Setting | |
1 | Dimmer | 000-255 | 0~100% | |
2 | Dimmer Fine | 000-255 | 0~100% | |
3 | Red | 000-255 | 0~100% | |
4 | Green | 000-255 | 0~100% | |
5 | Blue | 000-255 | 0~100% | |
6 | Amber | 000-255 | 0~100% | |
7 | White | 000-255 | 0~100% | |
8 | Strobe | 000-010 | No function | |
011-255 | Strobe slow to fast | |||
Color Macro | 000-005 | No Function | ||
006-013 | C3050-Md Yellow | |||
014-021 | C3040-Lt Yellow | |||
022-028 | C3240-Amb Yellow | |||
029-035 | C2340-VLt Amber | |||
036-043 | C2040-Lt Amber | |||
044-051 | C2050-Md Amber | |||
052-059 | C2060-Dk Amber | |||
060-067 | C1050-Lt Red | |||
068-075 | C1080-Md Red | |||
076-083 | C1020-NC Pink | |||
084-091 | C1030-Md Pink | |||
092-099 | C1630-Dk Pink | |||
100-107 | C1250-Md Red Amber | |||
108-115 | C1060-Dk Red Amber | |||
116-121 | C1650-Magenta | |||
122-130 | C6170-Dk Magenta | |||
131-138 | C6020-Lt Lavender | |||
139-146 | C5030-Lt Blue | |||
147-154 | C5020-VLt Blue | |||
155-162 | C5430-Lt Blue2 | |||
163-170 | C5070-Blue | |||
171-178 | C5050-Md Blue | |||
179-186 | C5060-Dk Blue | |||
187-194 | C5690-Indigo | |||
195-202 | C5080-VDk Blue | |||
203-210 | C5081-VdK Blue2 | |||
211-218 | C4370-Yel Green | |||
219-226 | C4070-Green | |||
227-234 | C4550-Turquoise | |||
235-242 | C4560-Aqua | |||
243-250 | C4570-Blue Green | |||
251-255 | No Function | |||
12CH | Function | Value | Percent/Setting | |
1 | Dimmer | 000-255 | 0~100% | |
2 | Red | 000-255 | 0~100% | |
3 | Green | 000-255 | 0~100% | |
4 | Blue | 000-255 | 0~100% | |
5 | Amber | 000-255 | 0~100% | |
6 | White | 000-255 | 0~100% | |
7 | Strobe | 000-010 | No function | |
011-255 | Strobe slow to fast | |||
Color Macro | 000-005 | No Function | ||
006-013 | C3050-Md Yellow | |||
014-021 | C3040-Lt Yellow | |||
022-028 | C3240-Amb Yellow | |||
029-035 | C2340-VLt Amber | |||
036-043 | C2040-Lt Amber | |||
044-051 | C2050-Md Amber | |||
052-059 | C2060-Dk Amber | |||
060-067 | C1050-Lt Red | |||
068-075 | C1080-Md Red | |||
076-083 | C1020-NC Pink | |||
084-091 | C1030-Md Pink | |||
092-099 | C1630-Dk Pink | |||
100-107 | C1250-Md Red Amber | |||
108-115 | C1060-Dk Red Amber | |||
116-121 | C1650-Magenta | |||
122-130 | C6170-Dk Magenta | |||
131-138 | C6020-Lt Lavender | |||
139-146 | C5030-Lt Blue | |||
147-154 | C5020-VLt Blue | |||
155-162 | C5430-Lt Blue2 | |||
163-170 | C5070-Blue | |||
171-178 | C5050-Md Blue | |||
179-186 | C5060-Dk Blue | |||
187-194 | C5690-Indigo | |||
195-202 | C5080-VDk Blue | |||
203-210 | C5081-VdK Blue2 | |||
211-218 | C4370-Yel Green | |||
219-226 | C4070-Green | |||
227-234 | C4550-Turquoise | |||
235-242 | C4560-Aqua | |||
243-250 | C4570-Blue Green | |||
251-255 | No Function | |||
Color Temperature | 000-005 | No Function | ||
006-019 | 2800K | |||
020-033 | 3000K | |||
034-047 | 3200K | |||
048-061 | 3500K | |||
062-075 | 4000K | |||
076-089 | 4500K | |||
090-103 | 5000K | |||
104-117 | 5600K | |||
118-131 | 6000K | |||
132-145 | 6500K | |||
146-159 | 7000K | |||
160-173 | 7500K | |||
174-187 | 8000K | |||
188-201 | 8500K | |||
202-215 | 9000K | |||
216-229 | 9500K | |||
230-243 | 10000K | |||
244-055 | No Function | |||
26 | Auto programs | 000-010 | No Function | |
011-040 | Auto Program 1 | |||
041-080 | Auto Program 2 | |||
081-120 | Auto Program 3 | |||
121-160 | Auto Program 4 | |||
161-200 | Auto Program 5 | |||
201-240 | Auto Program 6 | |||
241-255 | No Function | |||
27 | Auto speed | 000-255 | Auto speed slow to fast | |
000-007 | No function | |||
28 | Control (Hold 3 Seconds) | 008-015 | Dimmer Reset | |
016-023 | Red Shift: ON | |||
024-031 | Red Shift: OFF | |||
032-039 | Dimmer: S-Curve | |||
040-047 | Dimmer: Linear | |||
048-055 | Dimmer: Square | |||
056-063 | Dimmer: Inverse Square | |||
064-071 | Dimmer speed mode off | |||
072-079 | Dimmer speed mode1 | |||
080-087 | Dimmer speed mode2 | |||
088-095 | Dimmer speed mode3 | |||
096-103 | X-Fade Speed: OFF | |||
104-111 | X-Fade Speed: 1 | |||
112-119 | X-Fade Speed: 2 | |||
120-127 | X-Fade Speed: 3 | |||
128-135 | X-Fade Speed: 4 | |||
136-255 | Future Use (No Function) | |||
HSV | Function | Value | Percent/Setting | |
1 | Hue | 000-255 | 0~100% | |
2 | Saturation | 000-255 | 0~100% | |
3 | Value | 000-255 | 0~100% |
Maintenance
MAINTENANCE AND CLEANING THE UNIT
- Make sure the area below the installation place is free from unwanted persons during setup.
- Switch off the unit, unplug the main cable and wait until the unit has cooled down.
- All screws used for installing the device and any of its parts should be tightly fastened and should not be corroded.
- Housings, fixations and installation spots (ceiling, trusses, suspensions) should be totally free from any deformation.
- The main cables must be in impeccable condition and should be replaced immediately even when a small problem is detected.
- It is recommended to clean the front at regular intervals, from impurities caused by dust, smoke, or other particles to ensure that the light is radiated at maximum brightness. For cleaning, disconnect the main plug from the socket. Use a soft, clean cloth moistened with a mild detergent. Then carefully wipe the part dry. For cleaning other housing parts use only a soft, clean cloth. Never use a liquid, it might penetrate the unit and cause damage to it.
TROUBLESHOOTING
Problems | Possible causes | Checks and remedies |
Fixture does not light up | No mains supply Dimmer fader set to 0 All color faders set to 0 |
Check the power supply voltage Increase the value of the dimmer channels Increase the value of the color channels |
General low light intensity | Faulty LED Faulty LED board |
Replace the LED board Replace the LED board |
Fixture does not power up | Dirty lens assembly Misaligned lens assembly |
Clean the fixture regularly Install lens assembly properly |
Fixture does not respond to DMX | No power Loose or damaged power cord Faulty internal power supply |
Check for power on power outlet Check power cord Replace internal power supply |
Wrong DMX addressing Damaged DMX cables Bouncing signals |
Check control panel and unit addressing Check DMX cables Install terminator as suggested |
Contact an authorized service center in case of technical problems or not reported in the table cannot be resolved by the procedure given in the table.
Contact Information
EKINC.
Address: NO.55 Zhongzhun Road, Cuiheng New District, Zhongshan City, Guangdong Province
Phone: 0086 (0760) 88280099
Website: www.eklights.com
File Info : application/pdf, 26 Pages, 2.24MB
DocumentDocumentReferences
Adobe PDF library 15.00Related Documents
![]() |
EK R3 RGBW Beam Wash User Manual - Features, Specs, and Operation Comprehensive user manual for the EK R3 RGBW Beam Wash lighting fixture. Details features, specifications, DMX control, installation, and troubleshooting for professional stage and event lighting. |
![]() |
EK EC 60 User Manual User manual for the EK EC 60 lighting fixture, detailing its features, specifications, installation, operation, and troubleshooting. |
![]() |
EK MC15 1500W IP66 LED Moving Profile Light - Datasheet Technical specifications and features of the EK MC15, a 1500W IP66 rated LED moving profile light with a 4-in-1 Beam, Spot, Wash, and Profile function. Details include photometry, key features, color system, control, power, and physical dimensions. |
![]() |
EK-Quantum Vector² Strix RTX 3080/90 D-RGB GPU Water Block User Guide User guide for the EK-Quantum Vector² Strix RTX 3080/90 D-RGB GPU Water Block, detailing installation, specifications, and warranty information. |