INSTRUCTION MANUAL
WS
High-Temperature Wire Stripper Control Unit

This manual corresponds to the following references:
WS-9UA (100V) WS-1UA (120V) WS-2UA (230V)
Packing List
The following items are included:

High-Temperature Wire Stripper Control Unit ................... 1 unit

Power Cord .................... 1 unit Ref. 0024092 (100V)
0023715 (120V) 0023714 (230V)

Manual ............................ 1 unit Ref. 0030210

Features

Control Unit

USB Connector

To Stand Main Switch
2

Fuse

Equipotential connector Power Socket

Connection with WS140

Control Unit

WSU

WSU

USB Connector

Main Switch

Fuse

Stand Cable* Ref. 0024227

WSST* Stand for WS140 High-Temperature Precision Wire Stripper Tweezers

Equipotential Connector
Power Socket
W140* Blade Cartridges (not included)
WS140* High-Temperature Precision Wire Stripper Tweezers

*not included, sold separately
3

Connection with WS440

Stand cable* Ref. 0024227

WS High-Temperature Wire Stripper Control Unit

Main Switch

Fuse

WSBT* Stand for WS440 High-Temperature Wire Stripper Tweezers

USB Connector
Equipotential connector Power Socket
W440* Cartridges
WS440* High-Temperature Wire Strippers Tweezers

*not included, sold separately
4

Control Process
Work Screen
Selected Material
Next Material

KapPIton®90%
Power 75%

Power Level
Instant Power Previous Material

Work Mode

WS offers two different working modes. Switch the power on choose between Material Mode and Custom Mode by pressing the button.

1. Material Mode

2. Custom Mode

Choose between the different materials by pressing the buttons and to choose between all different material options.

To work on a customized mode, press and then the buttons and to
select the power level.

KapPtI on®90%
Power 75%

Custom 68%
Power 59%

5

Operation

Depending on where the tool is located, the soldering station switches between three different states: Work, Sleep and Hibernation. These states are available for JBCs High-Temperature Wire Strippers Tweezers WS140 and WS440.

1. Work

2. Sleep

3. Hibernation

When the wire stripper is lifted from the stand, the cartridges will heat up according to the selected configuration.

When the wire stripper is in the stand, the power falls after a specified time.

After longer periods of inactivity, the power is cut off and the cartridges cool down to room temperature.

KapPtI on®90%
Power 75%

KapPIton®90%
Sleep
Power 35%

KapPIton®90%
Hibernation
Power 0%

Troubleshooting Station troubleshooting available on the product page at www.jbctools.com
6

Material Mode
WS incorporates predeterminated power levels and it also features a customized work mode. It allows you to work on wire insulations made of thermoplastics and thermostable materials such as Teflon1, Kapton2, silicone, rubber, etc.
Options included:

Thermoplastics

Insulation Material Polyvinyl Chloride Polyethylene Nylon ¹ Kynar ² Tefzel ¹
Teflon ¹
Ethylene Propylene Rubber
Silicone Rubber Kapton ¹

Symbol
PVC PE PA PVDF ETFE FEP PFA PTFE EPM/EPR
SI PI

Power Level
6% 7% 10% 16% 17% 16% 21% 40% 44%
51% 90%

Thermostable

¹ Registred Trade Marks of DuPont ² Registred Trade Marks of Arkema
7

Accessories

Pedal P305 It can be used to activate/deactivate the Wire Stipper. Sleep and hibernation delay has to be set to 0 min.

Lift the wire stripper from the stand, press and hold the pedal to activate them and strip the wire. Once the pedal is relaesed the wire stripper enters in Hibernation. To reverse the pedal functionality flip the switch of the connection box.

Default PIN: 0105.

WS High-Temperature Wire Stripper Control Unit

WSST Stand for WS140 HighTemperature Precision Wire Stripper Tweezers

WS140 High-Temperature Precision Wire Stripper Tweezers

alternativly

Connecting Box

To reverse the pedal functionality

Pedal

WSBT Stand for WS440 HighTemperature Wire Stripper Tweezers

WS440* High-Temperature Wire Strippers Tweezers

NO-normally open (press to work) NC-normally closed (release to work)

Pedal Kit for Control Units Ref. P-305 (not included)

8

Accessories
Flat Screw Driver* To open or fix the wire stripper srews use JBC Flat Screw Driver Ref. 0023511.

Cartridge Extractor Pliers*
To manipulate the cartridges use JBC Cartridge Extractor Pliers Ref. PLR195. More Information at www.jbctools.com

Removing

Inserting and Positioning

Remove cartridges with JBC pliers.

Align cartridges with JBC pliers.

Metal Brush For cleaning the tips if unwanted material is stuck there. Metal Brush Ref. 0022793.

9

Maintenance

Before carrying out maintenance or storage, always allow the equipment to cool and unplug the stand from the station and the tool.

- Clean the station screen with a glass cleaner or a damp cloth.

- Use a damp cloth to clean the casing, the stand and the tool. Alcohol can only be used for cleaning the metal parts.

- Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status.
- Maintain tip surface clean in order to ensure a correct stripped wire.

Clean perodically

- Periodically check all cables.

WSBT Stand for WS440

- Replace a blown fuse as follows (see specification chart) :

WSST Stand for WS140

1. take out the fuse holder and remove the fuse. If necessary use a tool to lever it out.

2. Press the new fuse into the fuse holder and reinsert it in the station.

Fuse Holder

Fuse

Fuse - Replace any defective or damaged pieces. Use original JBC spare parts only. - Repairs should only be performed by a JBC authorized technical service.

Fuse Holder

10

Safety
It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.
Warning - Do not touch the blade or the metal parts around. - Do not allow the blade be close to flammable materials. - Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working
to avoid personal harm. - This appliance can be used by children over the age of eight and also persons with reduced physical,
sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved. - Maintenance must not be carried out by children unless supervised. - Place the tool on the stand when is not in use. - Turn off the power when not in use, changing parts or storing.
Caution - Do not use the Wire Stripper for other applications than wire stripping. - Do not modify or customize the Wire Stripper. - Do not hit the blade against workbench to eliminate stripped insulation debris. This behavior would
damage the blade. - Remove power from the tool by holding the plug, not the wires. - Be careful with the fumes produced when stripping. We recomend to use our fume extractor.
11

Specifications

WS High-Temperature Wire Stripper Control Unit Ref.: WSU-9A 100V 50/60Hz. Input Fuse: T1.6A. 5x20mm Output: 15V Ref.: WSU-1A 120V 50/60Hz. Input Fuse: T1.25A. 5x20mm Output: 15V. Ref.: WSU-2A 230V 50/60Hz. Input Fuse: T0.63A. 5x20mm Output: 15V.

- Temperature Max : - Power: - Ambient operating temp: - Connections: - Control Unit Dimensions / Weight:
(L x W x H)

800 ºC /1472 °F 75W 10 to 50 ºC /50 to 120 ºF USB-B 180 x 94 x 106 mm / 2.2 kg 7.1 x 3.7 x 4.2 in / 4.85 lb

- Total Net Weight:

3.8 kg / 8.4 lb

- Total Package Dimensions / Weight: 368 x 368 x 195 mm / 4.6 kg

(L x W x H)

14.5 x 14.5 x 7.7 in /10.15 lb

Complies with CE standards. ESD safe.

Warranty JBC's 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour. Warranty does not cover product wear or misuse. In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase.